771 resultados para h-index
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
O efeito de duas concentrações de cafeína (1500 e 2500 mg/ml) sobre o índice mitótico em Drosophila prosaltans foi analisado em células de gânglios cerebrais de larvas. Embora as diferenças detectadas entre células controle e tratadas não sejam significativas, as porcentagens obtidas poderiam ser sugestivas de algum efeito da cafeína ampliando a duração do processo de divisão celular
Resumo:
Evaluating the technical impacts associated with connecting distributed generation to distribution networks is a complex activity requiring a wide range of network operational and security effects to be qualified and quantified. One means of dealing with such complexity is through the use of indices that indicate the benefit or otherwise of connections at a given location and which could be used to shape the nature of the contract between the utility and distributed generator. This paper presents a multiobjective performance index for distribution networks with distributed generation which considers a wide range of technical issues. Distributed generation is extensively located and sized within the IEEE-34 test feeder, wherein the multiobjective performance index is computed for each configuration. The results are presented and discussed.
Resumo:
The nonlinear refractive index, n(2), of films based on the new glass system Sb(2)O(3)-Sb(2)S(3) was measured at 1064 nm with laser pulses of 15 ps, using a single-beam nonlinear image technique in presence of a phase object. The films were prepared from bulk glasses by RF-sputtering. A large value of n(2) = 3 x 10-(15) m(2)/W, which is three orders of magnitude larger than for CS(2), was determined. The result shows the strong potential of antimony-sulfide glass films for integrated nonlinear optics. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The objective of this work is to present an index which may synthesize a set of indicators of mobility for medium size cities urban centers. Three great areas were selected to compose the mobility index: pedestrians, motor vehicles and cycling. The Sampling Mobility Index is given by the sum of the punctuation the indicators selected and can to result in 700 points, the best result to mobility, and 0 points, the worse to mobility. The result obtained is given by the Sampling Mobility Index equal to 390. This result indicates a critical situation in Assis, as far as mobility is concerned. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
We investigate the Heston model with stochastic volatility and exponential tails as a model for the typical price fluctuations of the Brazilian São Paulo Stock Exchange Index (IBOVESPA). Raw prices are first corrected for inflation and a period spanning 15 years characterized by memoryless returns is chosen for the analysis. Model parameters are estimated by observing volatility scaling and correlation properties. We show that the Heston model with at least two time scales for the volatility mean reverting dynamics satisfactorily describes price fluctuations ranging from time scales larger than 20min to 160 days. At time scales shorter than 20 min we observe autocorrelated returns and power law tails incompatible with the Heston model. Despite major regulatory changes, hyperinflation and currency crises experienced by the Brazilian market in the period studied, the general success of the description provided may be regarded as an evidence for a general underlying dynamics of price fluctuations at intermediate mesoeconomic time scales well approximated by the Heston model. We also notice that the connection between the Heston model and Ehrenfest urn models could be exploited for bringing new insights into the microeconomic market mechanics. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The top faces of float glass samples were exposed to vapors resulting from the decomposition of KNO3 at 565 degrees C for up to 32 h. X-ray dispersive spectra (EDS) show that K+ ions migrate into the glass. The K+ concentration profile was obtained and its diffusion coefficient was calculated by the Boltzmann-Matano technique. The mean diffusion coefficient was approximately 10 X 10(-11) cm(2) s(-1). It was observed that the refractive index and the Vickers hardness decrease with the depth (after the removal of successive layers), and their profiles were thus obtained. These profiles enabled the calculation of the diffusion coefficient of K+ through the Boltzmann-Matano technique, with mean results ranging between 6 x 10(-11) and 30 x 10(-11) cm(2) s(-1). (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Glassy films of 0.2[Sb(PO3)(3)]-0,8Sb(2)O(3) with 0.8 mum-thickness were deposited on quartz substrates by electron beam evaporation. A contraction in the film thickness (photoinduced decrease in volume) and photobleaching effect associated with a decrease of up to 25% in the index of refraction has been observed in the films after irradiation near the bandgap (3.89 eV), using the 350.7 nm (3.54 eV) Kr+ ion laser line with 2.5 W/cm(2) for 30 min. A loss of 30% in the phosphorus concentration was measured by wavelength dispersive X-ray microanalysis in the film after laser irradiation with 5.0 W/cm(2) for 1.0 h. These photoinduced changes in the samples are dependent on the power density and intensity profile of the laser beam. Using a Lloyd's mirror setup for continuous wave holography it was possible to record holographic gratings with period from 500 nm up to 20 mum and depth profile of similar to50 nm in the films after laser irradiation with 5.0 W/cm(2) for 1 h. Real-time diffraction efficiency measurements have shown that ultraviolet irradiation induces first a refractive index grating formation, and after this, the photocon traction effect takes place generating an irreversible relief grating. Diffraction efficiency up to 10% was achieved for the recorded gratings. 3D-refraction index measurements and atomic force microscopy images are presented. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Recently, the Tei-index, a noninvasive index that combines systolic and diastolic time intervals, has been proposed to assess global cardiac performance. However, the effects of isoflurane on the Tei-index have not been characterized. This study aimed at studying the effects of 1.0 minimal alveolar concentration isoflurane anesthesia on the pre-ejection period (PEP), left ventricular ejection time (LVET), PEP/LVET ratio, isovolumic relaxation time (IVRT), stroke index (SI), cardiac index (CI), heart rate (HR), and the Tei-index in healthy unpremedicated dogs. We observed significant increases in PEP, PEP/LVET ratio, IVRT, and TEI, whose maximal increases obtained throughout the study were 47%, 48%, 78%, and 56%, respectively. The LVET and HR did not change significantly, whereas the SI and CI decreased during anesthesia (29% and 26%, respectively). In conclusion, isoflurane produced direct effects on the Tei-index. The changes in systolic and diastolic parameters were supportive of this finding and were consistent with an overall impairment of left ventricular function during anesthesia.
Resumo:
The J(1)...J(3) is a recent optical method for linear readout of dynamic phase modulation index in homodyne interferometers. In this work, the J(1)... J(3) method is applied to measure voltage in an optical voltage sensor. Based on the classical J(1)...J(4) method, the J(1)... J(3) technique shows to be more stable to phase drift and simpler for implementation than the original one. The sensor dynamic range is enhanced. The agreement between theoretical and experimental results, based on 1/f noise, is demonstrated.
Resumo:
To investigate the expression of a marker of cell proliferation (PCNA/Cyclin) and its putative relationship with histological grading, mitotic index and estrogen receptor immunoreactivity, we studied twenty-seven cases of invasive breast carcinoma in formalin-fixed, paraffin-embedded tissue sections. The PCNA and estrogen receptor were detected by the PC10 and H222 monoclonal antibodies respectively, using an avidin-biotin-pernxidase method. The median value of PCNA index was 20.9% with a range from 1.4 to 84.2%. We did not find any significant relationship between PCNA index anti the histological grading, mitotic index and estrogen receptor immunoreactivity. We conclude that PCNA detected by the monoclonal antibody PC10 in formalin-fixed material looks at present unrealiable as a proliferation marker in breast carcinoma.