976 resultados para computed tomograph (CT)
Resumo:
Background Pulmonary function tests (PFT), particularly spirometry and lung diffusing capacity for carbon monoxide (DL(CO)), have been considered useful methods for the detection of the progression of interstitial asbestos abnormalities as indicated by high-resolution computed tomography (HRCT). However, it is currently unknown which of these two tests correlates best with anatomical changes over time. Methods In this study, we contrasted longitudinal changes (3-9 years follow-up) in PFTs at rest and during exercise with interstitial abnormalities evaluated by HRCT in 63 ex-workers with mild-to-moderate asbestosis. Results At baseline, patients presented with low-grade asbestosis (Huuskonen classes I-II), and most PFT results were within the limits of normality. In the follow-up, most subjects had normal spirometry, static lung volumes and arterial blood gases. In contrast, frequency of DL(CO) abnormalities almost doubled (P < 0.05). Twenty-three (36.5%) subjects increased the interstitial marks on HRCT. These had significantly larger declines in DL(CO) compared to patients who remained stable (0.88 vs. 0.31 ml/min/mm Hg/year and 3.5 vs. 1.2%/year, respectively; P < 0.05). In contrast, no between-group differences were found for the other functional tests, including spirometry (P > 0.05). Conclusions These data demonstrate that the functional consequences of progression of HRCT abnormalities in mild-to-moderate asbestosis are better reflected by decrements in DL(CO) than by spirometric changes. These results might have important practical implications for medico-legal evaluation of this patient population. Am. J. Ind. Med. 54:185-193, 2011. (c) 2010 Wiley-Liss, Inc.
Resumo:
Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.
Resumo:
Background The development of products and services for health care systems is one of the most important phenomena to have occurred in the field of health care over the last 50 years. It generates significant commercial, medical and social results. Although much has been done to understand how health technologies are adopted and regulated in developed countries, little attention has been paid to the situation in low- and middle-income countries (LMICs). Here we examine the institutional environment in which decisions are made regarding the adoption of expensive medical devices into the Brazilian health care system. Methods We used a case study strategy to address our research question. The empirical work relied on in-depth interviews (N = 16) with representatives of a wide range of actors and stakeholders that participate in the process of diffusion of CT (computerized tomography) scanners in Brazil, including manufacturers, health care organizations, medical specialty societies, health insurance companies, regulatory agencies and the Ministry of Health. Results The adoption of CT scanners is not determined by health policy makers or third-party payers of public and private sectors. Instead, decisions are primarily made by administrators of individual hospitals and clinics, strongly influenced by both physicians and sales representatives of the medical industry who act as change agents. Because this process is not properly regulated by public authorities, health care organizations are free to decide whether, when and how they will adopt a particular technology. Conclusions Our study identifies problems in how health care systems in LMICs adopt new, expensive medical technologies, and suggests that a set of innovative approaches and policy instruments are needed in order to balance the institutional and professional desire to practise a modern and expensive medicine in a context of health inequalities and basic health needs.
Resumo:
PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516
Resumo:
Background: Increasing age and cholesterol levels, male gender, and family history of early coronary heart disease (CHD) are associated with early onset of CHD in familial hypercholesterolemia (FH). Objective: Assess subclinical atherosclerosis by computed tomography coronary angiography (CTCA) and its association with clinical and laboratorial parameters in asymptomatic FH subjects. Methods: 102 FH subjects (36% male, 45 +/- 13 years, LDL-c 280 +/- 54 mg/dL) and 35 controls (40% male, 46 +/- 12 years, LDL-c 103 +/- 18 mg/dL) were submitted to CTCA. Plaques were divided into calcified, mixed and non-calcified; luminal stenosis was characterized as >50% obstruction. Results: FH had a greater atherosclerotic burden represented by higher number of patients with: plaques (48% vs. 14%, p = 0.0005), stenosis (19% vs. 3%, p = 0.015), segments with plaques (2.05 +/- 2.85 vs. 0.43 +/- 1.33, p = 0.0016) and calcium scores (55 perpendicular to 129 vs. 38 perpendicular to 140, p = 0.0028). After multivariate analysis, determinants of plaque presence were increasing age (OR = 2.06, for age change of 10 years, CI95%: 1.38-3.07, p < 0.001) and total cholesterol (OR = 1.86, for cholesterol change by 1 standard deviation, CI95%: 1.09-3.15, p = 0.027). Coronary calcium score was associated with the presence of stenosis (OR = 1.54; CI95%: 1.27-1.86, p < 0.001, for doubling the calcium score). Male gender was directly associated with the presence of non-calcified plaques (OR: 15.45, CI95% 1.72-138.23, p = 0.014) and inversely with calcified plaques (OR = 0.21, CI95%: 0.05-0.84, p = 0.027). Family history of early CHD was associated with the presence of mixed plaques (OR = 4.90, CI95%: 1.32-18.21, p = 0.018). Conclusions: Patients with FH had an increased burden of coronary atherosclerosis by CTCA. The burden of atherosclerosis and individual plaque subtypes differed with the presence of other associated risk factors, with age and cholesterol being most important. A coronary calcium score of zero ruled out obstructive disease in this higher risk population. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.
Resumo:
Objective: To evaluate in chest X-rays and high-resolution computed tomographies of patients with pleural tuberculosis, the incidence of parenchymal and mediastinal lung lesions suggestive of active disease. Methods: Prospective study (2008-2009) evaluating the radiographic and tomographic abnormalities of 88 HIV-negative patients with pleural tuberculosis (unilateral effusion). The images were reviewed by 3 independent specialists, and the observed changes were classified according to previously established criteria: presence or absence of signs suggestive of disease activity, and nonspecific findings. Results: Abnormal changes were observed in chest X-rays of 22 (25%) patients and in the computed tomography of 55 (63%). Images compatible with active pulmonary tuberculosis were detected by radiography in 9 (10%) patients and by tomography in 38 (43%). Only 4 (4.5%) patients had tomography images suggestive of residual disease. Conclusion: The present study demonstrates that pulmonary involvement is quite common in pleural tuberculosis. This finding is mainly observed in high-resolution computed tomography and has important epidemiological implications, since patients with pleural tuberculosis are significant sources of infection and disease dissemination. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
OBJECTIVE: We studied the angiographic findings in patients with small epidural hematomas and cranial fractures crossing over the trajectory of the middle meningeal artery and its branches. Additionally, the Occurrence of traumatic vascular lesions and their clinical relevance and treatment are discussed. METHODS: A consecutive analysis was performed for 24 patients who harbored small epidural hematomas in middle meningeal artery topography associated with cranial fractures. Computed tomographic scans and plain x-ray studies were used to diagnose linear cranial fractures. Patients with large epidural hematomas or associated traumatic lesions were excluded from the study. Selective ipsilateral external carotid angiograms were obtained, and an endovascular procedure was performed if any vascular injury was evidenced. RESULTS: In all patients with cranial fractures crossing over the middle meningeal artery and its branches, some kind of vascular lesion was seen. Two types of findings were noted: active extravasation of the contrast medium (71%) and pseudoaneurysms (29%). Early filling of diploic vessels was found in 8.3% of fractures concomitantly with active extravasation. Embolization was performed in all patients. No additional enlargement of the epidural hematoma was observed, and the postoperative period was uneventful. CONCLUSION: This study shows that pseudoaneurysms and active extravasation of contrast are common findings in this subset of patients. Although the natural history of these lesions is still poorly understood, additional investigation with ipsilateral external carotid angiography may be recommended, considering the potentially catastrophic consequences of late rupture.
Resumo:
BACKGROUND: The development of newer diagnostic technologies has reduced the need for invasive electroencephalographic (EEG) studies in identifying the epileptogenic zone, especially in adult patients with mesial temporal lobe epilepsy and hippocampal sclerosis (MTLE-HS). OBJECTIVE: To evaluate ictal single photon emission computed tomography (SPECT) in the evaluation and treatment of patients with MTLE-HS. METHODS: MTLE patients were randomly assigned to those with (SPECT, n = 124) and without ictal SPECT (non-SPECT, n = 116) in an intent-to-treat protocol. Primary end points were the proportion of patients with invasive EEG studies, and those offered surgery. Secondary end points were the length of hospital stay and the proportion of patients with secondarily generalized seizures (SGS) during video-EEG, postsurgical seizure outcome, and hospital cost. RESULTS: The proportion of patients offered surgery was similar in the SPECT (85%) and non-SPECT groups (81%), as well as the proportion that had invasive EEG studies (27% vs 23%). The mean duration of hospital stay was 1 day longer for the SPECT group (P < 0.001). SGS occurred in 51% of the SPECT and 26% of the non-SPECT group (P < 0.001). The cost of the presurgical evaluation was 35% higher for the SPECT compared with the non-SPECT group (P < 0.001). The proportion of patients seizure-free after surgery was similar in the SPECT (59%) compared with non-SPECT group (54%). CONCLUSION: Ictal-SPECT did not add localizing value beyond what was provided by EEG-video telemetry and structural MRI that altered the surgical decision and outcome for MTLE-HS patients. Ictal-SPECT increased hospital stay was associated with increased costs and a higher chance of SGS during video-EEG monitoring. These findings support the notion that a protocol including ictal SPECT is equivalent to one without SPECT in the presurgical evaluation of adult patients with MTLE-HS.
Resumo:
Homozygous familial hypercholesterolemia (HoFH) is a rare disorder characterized by the early onset of atherosclerosis, often at the ostia of coronary arteries. In this study we document for the first time that aortic and coronary atherosclerosis can be detected using 64 slice multiple detector row computed tomographic coronary angiography (CTCA). We studied five HoFH patients (three females, two males, mean age 19.8 +/- 2.9 years, age range 15-23 years, with a mean low density lipoprotein (LDL) cholesterol 618 +/- 211 mg/dL) using 64 slice CTCA. None of the patients showed evidence of ischemia with standard exercise testing. Calcified and mixed atherosclerotic plaques adjacent to or compromising the coronary artery ostia were found in all study subjects. Coronary plaques causing significant obstruction were found in one patient, who had previously undergone coronary artery bypass surgery and aortic valve replacement. Two other patients were noted to have non-obstructive calcified, mixed and non-calcified coronary artery plaques. Our data suggest that CTCA could be a useful non-invasive method for detection of early aortic and coronary atherosclerosis specifically affecting the coronary ostia in HoFH subjects. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objectives: The aim of this study was to determine the precision of the measurements of 2 craniometric anatomic points-glabella and anterior nasal spine-in order to verify their possibility as potential locations for placing implants aimed at nasal prostheses retention. Methods: Twenty-six dry human skulls were scanned in a high-resolution spiral tomography with 1-mm axial slice thickness and 1-mm interval reconstruction using a bone tissue filter. Images obtained were stored and transferred to an independent workstation containing e-film imaging software. The measurements (in the glabella and anterior nasal fossa) were made independently by 2 observers twice for each measurement. Data were submitted to statistical analysis (parametric t test). Results: The results demonstrated no statistically significant difference between interobserver and intraobserver measurements (P > .05). The standard error was found to be between 0.49 mm and 0.84 mrn for measurements in bone protocol, indicating a high /eve/ of precision. Conclusions: The measurements obtained in anterior nasal spine and glabella were considered precise and reproducible. Mean values of such measurements pointed to the possibility of implant placement in these regions, particularly in the anterior nasal spine.
Resumo:
The calcifying cystic odontogenic tumour (CCOT) is a rare benign cystic neoplasm not infrequently associated with odontoma. This report documents a case of CCOT associated with compound odontoma arising in the anterior maxilla in a 25-year-old woman. Conventional radiographs showed a large calcified mass with poorly visualized radiolucent margins. The extent and condition of the internal structure of the CCOT associated with odontoma was able to be determined based on radiographic findings from cone beam computed tomography. This advanced image technique proved to be extremely useful in the radiographic assessment of this particular neoplasm of the jawbones.
Resumo:
Tumoural and cystic lesions are common findings in the daily practice of dental professionals and maxillofacial radiologists. However, simultaneous lesions are rare and represent a diagnostic challenge to overcome. Among tumoural pathologies, odontomas are the most common odontogenic tumour of the jaws. Cystic transformation or development from the tumoural capsule are well recognized in situations such as ameloblastomas originated from a dentigerous cyst. Otherwise, despite literature reports, dentigerous cysts arising from odontomas are very rare and could lead to misdiagnosis. Here, we report a case of a complex odontoma associated with a dentigerous cyst in the maxillary sinus, focussing on the tomographic features and a differential imaging approach to the diagnosis of these lesions.
Resumo:
Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865
Resumo:
Objective. The aim of this study was to determine the influence of periapical radiographs, cone beam computed tomography (CBCT) sections, and cone beam volumetric data on the determination of periapical bone destruction in endodontically treated distal root canals of premolar canine teeth. Nontreated mesial roots were used as controls. Study design. Enterococcus faecalis strain (ATCC 29212) was inoculated into 30 root canals of 2 mongrel dogs to induce apical periodontitis. After 60 days, the root canals of the distal roots of the 11 mandibular and 4 maxillary premolars were endodontically treated (n = 15). The mesial root canals were used as controls (no treatment). The bone destruction was evaluated after 6 months by 5 evaluators using periapical radiographs and by CBCT (coronal and sagittal sections). After the experimental period, the area of the lesions in periapical radiographs and CBCT sections were measured in mm(2) using the ImageTool software. A single evaluator measured the volumetric data using the OsiriX software. The comparison between the diagnosis methods in treated root canals and controls was performed using parametric and nonparametric criteria. The Pearson correlation coefficient was computed between radiographic values and CBCT volumetric data in treated root canals and controls. Results. The results showed the presence of chronic apical periodontitis in every inoculated tooth. After 6 months, periapical radiographs, coronal CBCT sections, and volumetric data showed lower bone destruction in endodontically treated teeth in comparison with the control group (P < .05). The 5 evaluators found no differences between the apical periodontitis area of treated teeth and controls when CBCT sagittal sections were used (P > .05). No correlation was found between x-ray and CBCT volumetric values in treated root canals. Conclusions. Although selected CBCT sagittal sections showed similar values of bone destruction in endodontically and nontreated root canals, volumetric CBCT data showed that periapical lesions of endodontically treated root canals had half of the volume of periapical lesions in nontreated root canals. No relationship could be found between the periapical values of bone destruction and volumetric data found in CBCT of treated rood canals. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 272-279)