902 resultados para additive Gaussian noise


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Literature mentions propyl gallate (PG) as a non-toxic synthetic antioxidant that can be used as a food additive due to its high tolerance to heat. It is important to understand the thermal properties and to identify the decomposition products of this substance, since it has been reported to be thermally stable at temperatures as high as 300 °C. Simultaneous thermogravimetry-differential thermal analysis (TG-DTA), differential scanning calorimetry-photovisual (DSC-photovisual), coupled thermogravimetry-infrared spectroscopy (TG-FTIR) analyses and spectroscopic techniques were used to study the food additive PG. The TG-DTA curves, which were performed with the aid of DSC-photovisual, provided information concerning the thermal stability and decomposition profiles of the compound. From the TG-FTIR coupled techniques, it was possible to identify n-propanol as a possible volatile compound released during the thermal decomposition of the antioxidant. A complete spectroscopic characterization in the ultraviolet, visible, near and middle infrared regions was performed in order to understand the spectroscopic properties of PG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous factors influencing the surface quality of wood after machining, among them we highlight the machining parameters and the properties of the wood. In the analysis of the influence of these factors on machining and in determining the quality measurement systems are used to obtain surface characteristics, these systems are divided into methods of contact and non-contact. The method for mechanical contact performed with the aid of the surface roughness tester is the most valued in the measurement of roughness of wood, however, aiming at a greater agility in these measurements, there is a need to seek alternatives for evaluation of surface quality, and one of these options is to use the forms of indirect measurements of this quality, as for example, the use of noise emission during the machining process. With this, the aim was to analyze the influence of the moisture content of the wood, at different levels, on surface quality of the species Pinus elliottii, determined by the method of mechanical probing move and relate this roughness with the sound emission issued for each class of humidity, during machining. The planning of experiments and statistical analyses were performed with the help of Taguchi method. The specimens were conditioned in greenhouses climatizadoras automatics for obtaining three classes of humidity. Machining tests of wooden pieces were performed on a machining center specific for this type of material. The roughness values were measured by a roughness verifier and the noise emission values were measured by for a measurer sound pressure level. Statistically significant differences were observed, the significance level of 10 %, on roughness and noise emission between the three levels of moisture. It was observed that with the increase in the moisture content occurred an increase of roughness and a reduction in noise emission. Monitoring of surface quality through noise level is an interesting alternative to the method of mechanical contact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the current study, we examined the influence of schema consistency on contradictory and additive misinformation. Sixty-four participants were shown a series of still photographs of common scenes (e.g., a kitchen), were later exposed to narratives containing misinformation, and were then tested on their memory of the photographic scenes. In addition, participants were asked to reflect on their phenomenological experience of remembering by giving remember/know responses. Participants reported greater false memory for schema-inconsistent items than schema-consistent items. The findings failed to replicate Roediger, Meade, and Bergman (2001). Explanations for the discrepant findings are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acoustic conditions in hospitals have been shown to influence a patient’s physical and psychological health. Noise levels in an Omaha, Nebraska, hospital were measured and compared between various times: before, during, and after renovations of a hospital wing. The renovations included cosmetic changes and the installation of new in-room patient audio-visual systems. Sound pressure levels were logged every 10-seconds over a four-day period in three different locations: at the nurses' station, in the hallway, and in a nearby patient’s room. The resulting data were analyzed in terms of the hourly A-weighted equivalent sound pressure levels (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we address the "skull-stripping" problem in 3D MR images. We propose a new method that employs an efficient and unique histogram analysis. A fundamental component of this analysis is an algorithm for partitioning a histogram based on the position of the maximum deviation from a Gaussian fit. In our experiments we use a comprehensive image database, including both synthetic and real MRI. and compare our method with other two well-known methods, namely BSE and BET. For all datasets we achieved superior results. Our method is also highly independent of parameter tuning and very robust across considerable variations of noise ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A poorly understood phenomenon seen in complex systems is diffusion characterized by Hurst exponent H approximate to 1/2 but with non-Gaussian statistics. Motivated by such empirical findings, we report an exact analytical solution for a non-Markovian random walk model that gives rise to weakly anomalous diffusion with H = 1/2 but with a non-Gaussian propagator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - The purpose of this paper is to present a method to analyze the noise in aircraft cabins through the VHF Aeronautical Communication Channel, aimed at examining an environment that has the possibility of communication problems between the aircraft crew and the professionals responsible for the controls on land. Design/methodology/approach - This analysis includes equipment normally used for identification and comparison of electromagnetic noise, the cabin and the environment that are present in an airport, as well as equipment for frequency analysis and intensity of those signals. The analysis is done in a reverse way, eliminating situations that are not common in the examined environment, until the identification of the situation with the irregularity. Findings - According to the results, the implementation of the Fourier transform for noise analysis in the cabin was efficient. These results demonstrate that through this transformation, the noise sources can be identified in the environments in cases where there is much spectrum pollution. Research limitations/implications - This kind of noise analysis is important, considering the importance of having good accuracy in airport environment analysis. Originality/value - The paper presents the main trends in the future of aviation communications, and describes the new applications that aim to minimize problems with the current VHF channel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optimal levels of noise stimulation have been shown to enhance the detection and transmission of neural signals thereby improving the performance of sensory and motor systems. The first series of experiments in the present study aimed to investigate whether subsensory electrical noise stimulation applied over the triceps surae (TS) in seated subjects decreases torque variability during a force-matching task of isometric plantar flexion and whether the same electrical noise stimulation decreases postural sway during quiet stance. Correlation tests were applied to investigate whether the noise-induced postural sway decrease is linearly predicted by the noise-induced torque variability decrease. A second series of experiments was conducted to investigate whether there are differences in torque variability between conditions in which the subsensory electrical noise is applied only to the TS, only to the tibialis anterior (TA) and to both TS and TA, during the force-matching task with seated subjects. Noise stimulation applied over the TS muscles caused a significant reduction in force variability during the maintained isometric force paradigm and also decreased postural oscillations during quiet stance. Moreover, there was a significant correlation between the reduction in force fluctuation and the decrease in postural sway with the electrical noise stimulation. This last result indicates that changes in plantar flexion force variability in response to a given subsensory random stimulation of the TS may provide an estimate of the variations in postural sway caused by the same subsensory stimulation of the TS. We suggest that the decreases in force variability and postural sway found here are due to stochastic resonance that causes an improved transmission of proprioceptive information. In the second series of experiments, the reduction in force variability found when noise was applied to the TA muscle alone did not reach statistical significance, suggesting that TS proprioception gives a better feedback to reduce force fluctuation in isometric plantar flexion conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate, in a population of crossbred cattle, the obtainment of the non-additive genetic effects for the characteristics weight at 205 and 390 days and scrotal circumference, and to evaluate the consideration of these effects in the prediction of breeding values of sires using different estimation methodologies. In method 1, the data were pre-adjusted for the non-additive effects obtained by least squares means method in a model that considered the direct additive, maternal and non-additive fixed genetic effects, the direct and total maternal heterozygosities, and epistasis. In method 2, the non-additive effects were considered covariates in genetic model. Genetic values for adjusted and non-adjusted data were predicted considering additive direct and maternal effects, and for weight at 205 days, also the permanent environmental effect, as random effects in the model. The breeding values of the categories of sires considered for the weight characteristic at 205 days were organized in files, in order to verify alterations in the magnitude of the predictions and ranking of animals in the two methods of correction data for the non-additives effects. The non-additive effects were not similar in magnitude and direction in the two estimation methods used, nor for the characteristics evaluated. Pearson and Spearman correlations between breeding values were higher than 0.94, and the use of different methods does not imply changes in the selection of animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The beta-adrenergic agonist ractopamine is increasingly used in the swine industry due to higher consumer demand for leaner pork products. Redirecting nutrients to favor leanness rather than fat deposition, ractopamine improves growth and carcass traits of finishing pigs. However, the impact of this agonist on pork quality is not clearly defined. Understanding the biological effects of dietary ractopamine dose, treatment period, lysine levels, and the lysine to metabolizable energy ratio will help pork producers achieve improvements in animal performance, carcass leanness, and economic efficiency in swine production systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, many chaos-based communication systems have been proposed. They can present the many interesting properties of spread spectrum modulations. Besides, they can represent a low-cost increase in security. However, their major drawback is to have a Bit Error Rate (BER) general performance worse than their conventional counterparts. In this paper, we review some innovative techniques that can be used to make chaos-based communication systems attain lower levels of BER in non-ideal environments. In particular, we succinctly describe techniques to counter the effects of finite bandwidth, additive noise and delay in the communication channel. Although much research is necessary for chaos-based communication competing with conventional techniques, the presented results are auspicious. (C) 2011 Elsevier B. V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two steel sheets, one with 5% Ni and another with 10% Ni, were submitted to carburization and quenching, obtaining a microstructure with martensite and retained austenite. These steels were characterized with magnetic Barkhausen noise (MBN). The Barkhausen signal is distinctively different for the carburized and quenched samples. The carburized and quenched samples present higher coercive field than the annealed samples. X-ray diffraction data indicated that the carburized and quenched samples have high density of dislocations, a consequence of the martensitic transformation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To investigate the relationship between multiple cryoprobes was investigated to determine whether they work in an additive or synergistic fashion in an in vivo animal model because 1.47 mm (17-gauge) cryoprobes have been introduced to the armamentarium for renal cryotherapy. METHODS Laparoscopic-guided percutaneous cryoablation was performed in both renal poles of 3 pigs using 3 IceRod cryoprobes. These 12 cryolesions were compared with 12 cryolesions using a single IceRod cryoprobe. Each cycle consisted of two 10-minute freeze cycles separated by a 5-minute thaw. The iceball volume was measured using intraoperative ultrasonography. The kidneys were harvested, and cryolesion surface area was calculated. The lesions were fixed and excised to obtain a volume measurement. Statistical analysis was used to compare the single probe results multiplied by 3 to the multiple probe group for iceball volume, cryolesion surface area, and cryolesion volume. RESULTS The iceball volume for the first freeze cycle for the single cryoprobe multiplied by 3 was 8.55 cm(3) compared with 9.79 cm(3) for the multiple cryoprobe group (P = .44) and 10.01 cm(3) versus 16.58 cm(3) for the second freeze (P = .03). The cryolesion volume for the single cryoprobe multiplied by 3 was 11.29 cm(3) versus 14.75 cm(3) for the multiple cyroprobe group (P = .06). The gross cryolesion surface area for the single cryoprobe multiplied by 3 was 13.14 cm(2) versus 13.89 cm(2) for the multiple probe group (P = .52). CONCLUSION The cryolesion created by 3 simultaneously activated 1.47-mm probes appears to be larger than that of an additive effect. The lesions were significantly larger as measured by ultrasonography and nearly so (P = .06) as measured by the gross cryolesion volume. UROLOGY 79: 484.e1-484.e6, 2012. (c) 2012 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the effects of spin accumulation (inside reservoirs) on electronic transport with tunneling and reflections at the gates of a quantum dot. Within the stub model, the calculations focus on the current-current correlation function for the flux of electrons injected into the quantum dot. The linear response theory used allows us to obtain the noise power in the regime of thermal crossover as a function of parameters that reveal the spin polarization at the reservoirs. The calculation is performed employing diagrammatic integration within the universal groups (ensembles of Dyson) for a nonideal, nonequilibrium chaotic quantum dot. We show that changes in the spin distribution determine significant alterations in noise behavior at values of the tunneling rates close to zero, in the regime of strong reflection at the gates.