916 resultados para The Performance Standard 6 –PS 6-


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of the immunochromatographic assay, SD BIOLINE TB Ag MPT64 RAPID®, was evaluated in Madagascar. Using mouse anti-MPT64 monoclonal antibodies for rapid discrimination between the Mycobacterium tuberculosis complex and nontuberculous mycobacteria, the kit was tested on mycobacteria and other pathogens using conventional methods as the gold standard. The results presented here indicate that this kit has excellent sensitivity (100%) and specificity (100%) compared to standard biochemical detection and can be easily used for the rapid identification of M. tuberculosis complex.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the human-landing catch (HLC) method is the most effective for collecting anthropophilic anophelines, it has been increasingly abandoned, primarily for ethical considerations. The objective of the present study was to develop a new trap for the collection of Anopheles darlingi . The initial trials were conducted using the BG-Sentinel trap as a standard for further trap development based on colour, airflow direction and illumination. The performance of the trap was then compared with those of the CDC, Fay-Prince, counterflow geometry trap (CFG) and HLC. All trials were conducted outdoors between 06:00 pm-08:00 pm. Female specimens of An. darlingi were dissected to determine their parity. A total of 8,334 anophelines were captured, of which 4,945 were identified as An. darlingi . The best trap configuration was an all-white version, with an upward airflow and no required light source. This configuration was subsequently named BG-Malaria (BGM). The BGM captured significantly more anophelines than any of the other traps tested and was similar to HLC with respect to the number and parity of anophelines. The BGM trap can be used as an alternative to HLC for collecting anophelines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: Gas6 is known to be elevated in sepsis, correlating with the severity of infection and organ failure. We aimed to investigate the performance of Gas6 plasma levels at admission to predict the risk of mortality in a cohort of septic patients.Methods: We used prospectively collected data and plasma samples from the 'Sepsis Cohorte Romande'. Gas6 level was measured by ELISA at admission and expressed in percentage relative to its level in a pool of normal plasma.Results: Non-survivors (n = 19) presented higher Gas6 levels than survivors (n = 78; median 287% vs. 158%, IQR 182 and 119 respectively; P = 0.0003). Gas6 correlated positively with different cytokine and was the best mortality predictor, as shown by the ROC curves area (Fig. 1). In patients with septic shock (n = 67), using 249% as a cut-off value, Gas6 measurement had a specificity of 81% and a sensitivity of 68% for predicting mortality. ROC curve area was 0.76. Positive and negative predictive values were 59% and 87%, respectively.Conclusion: Thus, Gas6 plasma level at admission might be a useful tool to predict mortality in patients with septic shock. Nevertheless, independent association of Gas6 level with mortality still needs to be assessed. Although Gas6 hold promise as an early sepsis marker, its precise implication in sepsis remains to be elucidated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to conduct a systematic review and perform a meta-analysis on the diagnostic performances of (18)F-fluorodeoxyglucose positron emission tomography (FDG PET) for giant cell arteritis (GCA), with or without polymyalgia rheumatica (PMR). METHODS: MEDLINE, Embase and the Cochrane Library were searched for articles in English that evaluated FDG PET in GCA or PMR. All complete studies were reviewed and qualitatively analysed. Studies that fulfilled the three following criteria were included in a meta-analysis: (1) FDG PET used as a diagnostic tool for GCA and PMR; (2) American College of Rheumatology and Healey criteria used as the reference standard for the diagnosis of GCA and PMR, respectively; and (3) the use of a control group. RESULTS: We found 14 complete articles. A smooth linear or long segmental pattern of FDG uptake in the aorta and its main branches seems to be a characteristic pattern of GCA. Vessel uptake that was superior to liver uptake was considered an efficient marker for vasculitis. The meta-analysis of six selected studies (101 vasculitis and 182 controls) provided the following results: sensitivity 0.80 [95% confidence interval (CI) 0.63-0.91], specificity 0.89 (95% CI 0.78-0.94), positive predictive value 0.85 (95% CI 0.62-0.95), negative predictive value 0.88 (95% CI 0.72-0.95), positive likelihood ratio 6.73 (95% CI 3.55-12.77), negative likelihood ratio 0.25 (95% CI 0.13-0.46) and accuracy 0.84 (95% CI 0.76-0.90). CONCLUSION: We found overall valuable diagnostic performances for FDG PET against reference criteria. Standardized FDG uptake criteria are needed to optimize these diagnostic performances.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective Evaluating the performance of primary care services for the treatment of tuberculosis according to the assessment referential of health services (structure/process) in Cabedelo, a port city in the state of Paraíba. Method An evaluation quantitative, cross-sectional study, in which were carried out 117 interviews with health professionals using a structured instrument. The analysis was based on the construction of indicators using a standardized value for the reduced variable (z=1). Results The structural indicators showed regular performance for the following variables: professional training, access to record instruments and coordination with other services. The process indicators related to external actions and information about the disease had unsatisfactory performance. The directly observed treatment and the flows of reference/counter-reference had regular performance. Conclusion The focused professional qualification, the fragmentation of practices and the unsystematic home care constitute obstacles for carrying out actions aimed at providing expanded, continuous and resolute care.



Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: Gas6 is known to be elevated in sepsis, correlating with the severity of infection and¦organ failure. We aimed to investigate the performance of Gas6 plasma levels at¦admission to predict the risk of mortality in a cohort of septic patients.¦Methods: We used prospectively collected data and plasma samples from the "Sepsis¦Cohorte Romande". Gas6 level was measured by ELISA at admission and expressed in¦percentage relative to its level in a pool of normal plasma.¦Results: Non-survivors (n=21) presented higher Gas6 levels than survivors (n=73) (median¦258% vs 164%, IQR 194 and 117 respectively) (p=0.0027). Gas6 correlated positively with¦different cytokines and was the best mortality predictor, as shown by the ROC curves area.¦In patients with septic shock (n=66), using 249% as a cut-off value, Gas6 measurement¦had a specificity of 67% and a sensitivity of 81% for predicting mortality. ROC curve area¦was 0.75. Positive and negative predictive values were 57% and 87%, respectively.¦Conclusion: Thus, Gas6 plasma level at admission might be a useful tool to predict¦mortality in patients with septic shock. Although Gas6 hold promise as an early sepsis¦marker, its precise implication in sepsis remains to be elucidated. Our observation should¦be further investigated in larger prospective clinical trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure using a chirobiotic V column is presented which allows separation of the enantiomers of citalopram and its two N-demethylated metabolites, and of the internal standard, alprenolol, in human plasma. Citalopram, demethylcitalopram and didemethylcitalopram, as well as the internal standard, were recovered from plasma by liquid-liquid extraction. The limits of quantification were found to be 5 ng/ml for each enantiomer of citalopram and demethylcitalopram, and 7.5 ng/ml for each enantiomer of didemethylcitalopram. Inter- and intra-day coefficients of variation varied from 2.4% to 8.6% for S- and R-citalopram, from 2.9% to 7.4% for S- and R-demethylcitalopram, and from 5.6% to 12.4% for S- and R- didemethylcitalopram. No interference was observed from endogenous compounds following the extraction of plasma samples from 10 different patients treated with citalopram. This method allows accurate quantification for each enantiomer and is, therefore, well suited for pharmacokinetic and drug interaction investigations. The presented method replaces a previously described highly sensitive and selective high-performance liquid chromatography procedure using an acetylated 3-cyclobond column which, because of manufactural problems, is no longer usable for the separation of the enantiomers of citalopram and its demethylated metabolites.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper studies the effect of providing relative performance feedback information onindividual performance and on individual affective response, when agents are rewardedaccording to their absolute performance. In a laboratory set-up, agents perform a realeffort task and when receiving feedback, they are asked to rate their happiness, arousaland feeling of dominance. Control subjects learn only their absolute performance, whilethe treated subjects additionally learn the average performance in the session.Performance is 17 percent higher when relative performance feedback is provided.Furthermore, although feedback increases the performance independent of the content(i.e., performing above or below the average), the content is determinant for theaffective response. When subjects are treated, the inequality in the happiness and thefeeling of dominance between those subjects performing above and below the averageincreases by 8 and 6 percentage points, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigates the intra-individual stability of the speed of several motor tasks and the intensity of associated movements in 256 children (131 girls, 125 boys) from the Zurich generational study using the Zurich neuromotor assessment battery (ZNA) over a 12-year period from the age of 6 to 18 years. The stability was assessed by correlograms of standard deviation scores calculated from age- and gender-adjusted normative values and compared with standing height and full scale intelligence quotient (IQ). While motor tasks of hand, finger and foot (HFT) and contralateral associated movements (CAM) exhibited a moderate stability (summary measure as correlation coefficients between two measurements made 4 years apart: .61 and .60), other tasks (dynamic balance, static balance and pegboard) were only weakly stable (.46, .47 and .49). IQ and height were more stable than neuromotor components (.72 and .86). We conclude that the moderately stable HFT and CAM may reflect "motor traits", while the stability of the pegboard and balance tasks is weaker because these skills are more experience related and state-dependent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To determine the sensitivity of ultrasonography in screening for foetal malformations in the pregnant women of the Swiss Canton of Vaud. STUDY DESIGN: Retrospective study over a period of five years. METHOD: We focused our study on 512 major or minor clinically relevant malformations detectable by ultrasonography. We analysed the global sensitivity of the screening and compared the performance of the tertiary centre with that of practitioners working in private practice or regional hospitals. RESULTS: Among the 512 malformations, 181 (35%) involved the renal and urinary tract system, 137 (27%) the heart, 71 (14%) the central nervous system, 50 (10%) the digestive system, 42 (8%) the face and 31 (6%) the limbs. Global sensitivity was 54.5%. The lowest detection rate was observed for cardiac anomalies, with only 23% correct diagnoses. The tertiary centre achieved a 75% detection rate in its outpatient clinic and 83% in referred patients. Outside the referral centre, the diagnostic rate attained 47%. CONCLUSIONS: Routine foetal examination by ultrasonography in a low-risk population can detect foetal structural abnormalities. Apart from the diagnosis of cardiac abnormalities, the results in the Canton of Vaud are satisfactory and justify routine screening for malformations in a low-risk population. A prerequisite is continuing improvement in the skills of ultrasonographers through medical education.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The US Highway 6 Bridge over Keg Creek outside of Council Bluffs, Iowa is a demonstration bridge site chosen to put into practice newly-developed Accelerated Bridge Construction (ABC) concepts. One of these new concepts is the use of prefabricated high performance concrete (HPC) bridge elements that are connected, in place, utilizing advanced material closure-pours and quick-to-install connection details. The Keg Creek Bridge is the first bridge in the US to utilize moment-resisting ultra-high performance concrete (UHPC) joints in negative moment regions over piers. Through laboratory and live load field testing, performance of these transverse joints as well as global bridge behavior is quantified and examined. The effectiveness of the structural performance of the bridge is evaluated to provide guidance for future designs of similar bridges throughout the US.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: In an experimental setting, the performance of the LifeBox, a new portable extracorporeal membrane oxygenator (ECMO) system suitable for patient transport, is presented. Standard rectilinear percutaneous cannulae are normally employed for this purpose, but have limited flow and pressure delivery due to their rigid structure. Therefore, we aimed to determine the potential for flow increase by using self-expanding venous cannulae. METHODS: Veno-arterial bypass was established in three pigs (40.6+/-5.1 kg). The venous line of the cardiopulmonary bypass was established by cannulation of the external jugular vein. The arterial side of the circulation was secured by cannulation of the common carotid artery. Two different venous cannulae (SmartCanula 18/36F 430mm and Biomedicus 19F) were examined for their functional integrity when used in conjunction with the centrifugal pump (500-3000 RPM) of the LifeBox system. RESULTS: At 1500, 2000, 2500, and 3000 RPM, the blood flow increased steadily for each cannula, but remained higher in the self-expanding cannula. That is, the 19F rectilinear cannula achieved a blood flow of 0.93+/-0.14, 1.47+/-0.37, 1.9+/-0.68, and 1.5+/-0.9 l/min, respectively, and the 18/36F self-expanding cannula achieved 1.1+/-0.1, 1.9+/-0.33, 2.8+/-0.39 and 3.66+/-0.52 l/min. However, when tested for venous line pressure, the standard venous cannula achieved -29+/-10.7mmHg while the self-expanding cannula achieved -13.6 +/-4.3mmHg at 1500 RMP. As the RPM increased from 2500 to 3000, the venous line pressure accounted for -141.9+/-20 and -98+/-7.3mmHg for the 19F rectilinear cannula and -30.6+/-6.4 and -45+/-11.6mmHg for the self-expanding cannula. CONCLUSION: The self-expanding cannula exhibited superior venous drainage ability when compared to the performance of the standard rectilinear cannula with the use of the LifeBox. The flow rate achieved was approximately 40% greater than the standard drainage device, with a maximal pump flow recorded at 4.3l/min.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Alcohol (ethanol) is consumed on a daily basis by a large fraction of the population, and in many countries, light-to-moderate alcohol consumption is considered as an integral part of the diet. Although the relationship between alcohol intake and obesity is controversial, regular consumption of alcohol, through its effects in suppressing fat oxidation, is regarded as a risk factor for weight gain, increased abdominal obesity and hypertriglyceridemia. Indeed, alcohol taken with a meal leads to an increase in postprandial lipemia-an effect on postprandial metabolism that is opposite to that observed with exercise. Furthermore, although regular exercise training and/or a preprandial exercise session reduce postprandial lipemia independently of alcohol ingestion, the exercise-induced reduction in postprandial lipemia is nonetheless less pronounced when alcohol is also consumed with the meal. Whether or not alcohol influences exercise and sport performance remains contradictory. It is believed that alcohol has deleterious effects on the performance, although it may contribute to reduce pain and anxiety. The alcohol effects on sports performance depend on the type and dosage of alcohol, acute vs chronic administration, the alcohol elimination rate as well as the type of exercise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery