951 resultados para Single system image


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An effective face detection system used for detecting multi pose frontal face in gray images is presented. Image preprocessing approaches are applied to reduce the influence of the complex illumination. Eye-analog pairing and improved multiple related template matching are used to glancing and accurate face detecting, respectively. To shorten the time cost of detecting process, we employ prejudge rules in checking candidate image segments before template matching. Test by our own face database with complicated illumination and background, the system has high calculation speed and illumination independency, and obtains good experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we present a robust face location system based on human vision simulations to automatically locate faces in color static images. Our method is divided into four stages. In the first stage we use a gauss low-pass filter to remove the fine information of images, which is useless in the initial stage of human vision. During the second and the third stages, our technique approximately detects the image regions, which may contain faces. During the fourth stage, the existence of faces in the selected regions is verified. Having combined the advantages of Bottom-Up Feature Based Methods and Appearance-Based Methods, our algorithm performs well in various images, including those with highly complex backgrounds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

622Mbits/s free space laser communication system is developed. IT's communication rate is 622Mbits/s. The whole system include three parts which are signal in and out circuit laser driver and receive circuit and optical antenna The communication principle is introduced The experiment result shows that the transmission of data and image are satisfied with demands of design. It have a definite market value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the development of a real-time stereovision system to track multiple infrared markers attached to a surgical instrument. Multiple stages of pipeline in field-programmable gate array (FPGA) are developed to recognize the targets in both left and right image planes and to give each target a unique label. The pipeline architecture includes a smoothing filter, an adaptive threshold module, a connected component labeling operation, and a centroid extraction process. A parallel distortion correction method is proposed and implemented in a dual-core DSP. A suitable kinematic model is established for the moving targets, and a novel set of parallel and interactive computation mechanisms is proposed to position and track the targets, which are carried out by a cross-computation method in a dual-core DSP. The proposed tracking system can track the 3-D coordinate, velocity, and acceleration of four infrared markers with a delay of 9.18 ms. Furthermore, it is capable of tracking a maximum of 110 infrared markers without frame dropping at a frame rate of 60 f/s. The accuracy of the proposed system can reach the scale of 0.37 mm RMS along the x- and y-directions and 0.45 mm RMS along the depth direction (the depth is from 0.8 to 0.45 m). The performance of the proposed system can meet the requirements of applications such as surgical navigation, which needs high real time and accuracy capability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies the development of a real-time stereovision system to track multiple infrared markers attached to a surgical instrument. Multiple stages of pipeline in field-programmable gate array (FPGA) are developed to recognize the targets in both left and right image planes and to give each target a unique label. The pipeline architecture includes a smoothing filter, an adaptive threshold module, a connected component labeling operation, and a centroid extraction process. A parallel distortion correction method is proposed and implemented in a dual-core DSP. A suitable kinematic model is established for the moving targets, and a novel set of parallel and interactive computation mechanisms is proposed to position and track the targets, which are carried out by a cross-computation method in a dual-core DSP. The proposed tracking system can track the 3-D coordinate, velocity, and acceleration of four infrared markers with a delay of 9.18 ms. Furthermore, it is capable of tracking a maximum of 110 infrared markers without frame dropping at a frame rate of 60 f/s. The accuracy of the proposed system can reach the scale of 0.37 mm RMS along the x- and y-directions and 0.45 mm RMS along the depth direction (the depth is from 0.8 to 0.45 m). The performance of the proposed system can meet the requirements of applications such as surgical navigation, which needs high real time and accuracy capability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The not only lower but also uniform MEMS chip temperatures can he reached by selecting suitable boiling number range that ensures the nucleate boiling heat transfer. In this article, boiling heat transfer experiments in 10 silicon triangular microchannels with the hydraulic diameter of 55.4 mu m were performed using acetone as the working fluid, having the inlet liquid temperatures of 24-40 degrees C, mass fluxes of 96-360 kg/m(2)s, heat fluxes of 140-420 kW/m(2), and exit vapor mass qualities of 0.28-0.70. The above data range correspond to the boiling number from 1.574 x 10(-3) to 3.219 x 10(-3) and ensure the perfect nucleate boiling heat transfer region, providing a very uniform chip temperature distribution in both streamline and transverse directions. The boiling heat transfer coefficients determined by the infrared radiator image system were found to he dependent on the heat Axes only, not dependent on the mass Axes and the vapor mass qualities covering the above data range. The high-speed flow visualization shows that the periodic flow patterns take place inside the microchannel in the time scale of milliseconds, consisting of liquid refilling stage, bubble nucleation, growth and coalescence stage, and transient liquid film evaporation stage in a full cycle. The paired or triplet bubble nucleation sites can occur in the microchannel corners anywhere along the flow direction, accounting for the nucleate boiling heat transfer mode. The periodic boiling process is similar to a series of bubble nucleation, growth, and departure followed by the liquid refilling in a single cavity for the pool boiling situation. The chip temperature difference across the whole two-phase area is found to he small in a couple of degrees, providing a better thermal management scheme for the high heat flux electronic components. Chen's [11 widely accepted correlation for macrochannels and Bao et al.'s [21 correlation obtained in a copper capillary tube with the inside diameter of 1.95 mm using R11 and HCFC123 as working fluids can predict the present experimental data with accepted accuracy. Other correlations fail to predict the correct heat transfer coefficient trends. New heat transfer correlations are also recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A glutamate biosensor based on the electrocatalytic oxidation of reduced nicotinamide adenine dinucleotide (NADH), which was generated by the enzymatic reaction, was developed via employing a single-walled carbon nanotubes/thionine (Th-SWNTs) nanocomposite as a mediator and an enzyme immobilization matrix. The biosensor, which was fabricated by immobilizing glutamate dehydrogenase (GIDH) on the surface of Th-SWNTs, exhibited a rapid response (ca. 5 s), a low detection limit (0.1 mu M), a wide and useful linear range (0.5-400 mu M), high sensitivity (137.3 +/- 15.7) mu A mM(-1) cm(-2), higher biological affinity, as well as good stability and repeatability. In addition, the common interfering species, such as ascorbic acid, uric acid, and 4-acetamidophenol, did not cause any interference due to the use of a low operating potential (190 mV vs. NHE). The biosensor can be used to quantify the concentration of glutamate in the physiological level. The Th-SWNTs system represents a simple and effective approach to the integration of dehydrogenase and electrodes, which can provide analytical access to a large group of enzymes for wide range of bioelectrochemical applications including biosensors and biofuel cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we investigate the mechanism of tunable parametric superfluorescence (PS) based on the second harmonic generation and parametric processes taking place in the same nonlinear crystal (BBO). The tunable spectra of PS has been generated between 480 nm and 530 nm, which is pumped by the second-harmonic from the high-power Ti: sapphire laser system at 1 kHz repetition rate. We present the generation mechanism of PS theoretically and simulate the process of PS ring using the amplification transfer function. The experiment and the theory show that PS will appear when the phase matching angle for second-harmonic generation is close to the optimal pump angle for optical parametric generation, and then the tunable spectra of PS are generated by slightly adjusting the crystal angle. The result provides a theoretical basis for controlling the generation of PS and quantum entanglement states, which is of great significance for the development of quantum imaging, quantum communications and other applieations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A bisfurylfulgide, E, E-3,4-bis[1-(2,5-dimethyl-3-furyl)ethylidene]-3,4-dihydrofuran-2,5-dione, is synthesized by Stobbe condensation reaction. The molecular structure of target compound is confirmed by single crystal X-ray crystallography analysis. It shows that the distances between two possible reaction sites of molecule are 0.3394 and 0.3406 nm respectively, which is favorable to photocyclization. The photochromic properties of this compound in different solvents are investigated, and the result shows that the compound exhibits excellent photochromic behavior. The primary result of applied research on parallel image storage is also presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a novel high-energy, single-mode, all-fiber-based master-oscillator-power-amplifier (MOPA) laser system operating in the C-band with 3.3-ns pulses and a very widely tunable repetition rate, ranging from 30 kHz to 50 MHz. The laser with a maximum pulse energy of 25 mu J and a repetition rate of 30 kHz is obtained at, a wavelength of 1548 nm by using a double-clad, single-mode, Er:Yb co-doped fiber power amplifier.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the design of an interference imaging spectrometer. A static Polarization Imaging Spectrometer (PIS) based on a single Savart polariscope has been developed. It produces the interferogram and target's image in the spatial domain which are recorded by using a two-dimensional (2D) CCD detector. Imaging lens localizes the interference fringes and target's image coincident with the plane of detector, thereby facilitating an extremely compact design. The spectrum of the input light is reconstructed through the Fourier-transform of the interferogram. The total optics is as small as 20 x 6 cm phi in size and the spectral resolution of the prototype system is 97.66 cm(-1) between 25,000 and 10, 000 cm(-1). The polarization interference imaging device has advantages of ultra-compact size, wide field of view, high throughput and without any moving parts. (C) 2002 Published by Elsevier Science B.V.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A thermal model for concentrator solar cells based on energy conservation principles was designed. Under 400X concentration with no cooling aid, the cell temperature would get up to about 1200℃.Metal plates were used as heat sinks for cooling the system, which remarkably reduce the cell temperature. For a fixed concentration ratio, the cell temperature reduced as the heat sink area increased. In order to keep the cell at a constant temperature, the heat sink area needs to increase linearly as a function of the concentration ratio. GaInP/GaAs/Ge triple-junction solar cells were fabricated to verify the model. A cell temperature of 37℃ was measured when using a heat sink at 400X concentratration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A near-infrared single-photon detection system is established by using pigtailed InGaAs/InP avalanche photodiodes. With a 50GHz digital sampling oscilloscope, the function and process of gated-mode (Geiger-mode) single-photon detection are intuitionally demonstrated for the first time. The performance of the detector as a gated-mode single-photon counter at wavelengths of 1310 and 1550nm is investigated. At the operation temperature of 203K,a quantum efficiency of 52% with a dark count probability per gate of 2. 4 * 10~(-3), and a gate pulse repetition rate of 50kHz are obtained at 1550nm. The corresponding parameters are 43% , 8. 5 * 10~(-3), and 200kHz at 238K.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A realistic measurement setup for a system such system measured by a mesoscopie detector,is theoretically as a charged two-state (qubit) or multi-state quantum studied. To properly describe the measurement-induced back-action,a detailed-balance preserved quantum master equation treatment is developed. The established framework is applicable for arbitrary voltages and temperatures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Single crystalline 3C-SiC epitaxial layers are grown on φ50mm Si wafers by a new resistively heated CVD/LPCVD system, using SiH_4, C_2H_4 and H_2 as gas precursors. X-ray diffraction and Raman scattering measurements are used to investigate the crystallinity of the grown films. Electrical properties of the epitaxial 3C-SiC layers with thickness of 1 ~ 3μm are measured by Van der Pauw method. The improved Hall mobility reaches the highest value of 470cm~2/(V·s) at the carrier concentration of 7.7 * 10~(17)cm~(-3).