968 resultados para SPHERICAL ANTENNA
Resumo:
This work introduces a novel idea for wireless energy transfer, proposing for the first time the unit-cell of an indoor localization and RF harvesting system embedded into the floor. The unit-cell is composed by a 5.8 GHz patch antenna surrounded by a 13.56 MHz coil. The coil locates a device and activate the patch which, connected to a power grid, radiates to wirelessly charge the localized device. The HF and RF circuits co-existence and functionality are demonstrated in this paper, the novelty of which is also in the adoption of low cost and most of all ecofriendly materials, such as wood and cork, as substrates for electronics.
Resumo:
In this paper we show the design of passive UHF RFID tag antenna on cork substrate. Due to the cork sensitivity to humidity changes, we can use the developed sensor to sense changes in the relative humidity of the environment, without the need for batteries. The antenna is built using inkjet printing technology, which allows a good accuracy of the design manufacturing. The sensor proved usable for humidity changes detection with a variation of threshold power from 11 to 15 dB between 60 and near 100% humidity levels. Presenting, therefore, reading ranges between 3 to 5 meters. © 2015 EurAAP.
Resumo:
We report the observation of acid-fast Cyclospora cayetanensis oocysts in a sputum sample. The patient, a 60 year-old, HIV negative man, was successfully treated for pulmonary tuberculosis during 1997. On February 1998, he was admitted to our center due to loss of weight, cough with purulent expectoration, dysphonia and a radiological picture of pulmonary fibrosis. Bacilloscopic study of sputum (negative for acid-fast bacilli) stained with Ziehl-Neelsen technique showed large (8-10 µm) spherical, acid-fast Cyclospora cayetanensis oocysts. No other pathogens were isolated on cultures from this sample or from laryngeal biopsy. Serial parasitologic studies showed C. cayetanensis and also eggs of Trichuris trichiura, Ascaris lumbricoides and Hymenolepis nana and of Entamoeba coli cysts. The patient lives in the outskirts of Buenos Aires in a brick-made house with potable water and works as builder of sewers. He travelled in several occasions to the rural area of province of Tucumán which has poor sanitary conditions. C. cayetanensis is an emergent agent of diarrhea and as far as we know this is the first time the parasite is observed in respiratory samples.
Resumo:
RTUWO Advances in Wireless and Optical Communications 2015 (RTUWO 2015). 5-6 Nov Riga, Latvia.
Resumo:
To evaluate the short and mid-term results of prostatic artery embolization in patients with benign prostatic embolization. Retrospective study between March 2009 and June 2011 with 103 patients (mean age 66.8 years, 50-85) that met our inclusion criteria with symptomatic benign prostatic hyperplasia. The clinical outcome was evaluated by the International Prostate Symptom Score (IPSS), quality of life (QoL), International Index of Erectile Function, prostate volume (PV), prostate-specific antigen (PSA), peak urinary flow (Q(max)), and post-void residual volume (PVR) measurements at 3 and 6 months, 1 year, 18 months, and 2 years after PAE and comparison with baseline values was made. Technical and clinical successes, as well as poor clinical outcome definitions, were previously defined. In this review, we evaluate the short and mid-term clinical outcomes and morbidity of patients treated only with non-spherical polyvinyl alcohol. Six months after the procedure, the PV decreased about 23%, IPSS changed to a mean value of 11.95 (almost 50% reduction), the QoL improved slightly more than 2 points, the Q(max) changed to a mean value of 12.63mL/s, the PVR underwent a change of almost half of the baseline value, and the PSA decreased about 2.3ng/mL. In the mid-term follow-up and comparing to the baseline values, we still assisted to a reduction in PV, IPSS, QoL, PVR, and PSA, and an increase in Q(max). Prostatic Artery Embolization is a safe procedure with low morbidity that shows good short- and mid-term clinical outcome in our institution.
Resumo:
A evolução tecnológica atingiu um ritmo que muitas empresas têm dificuldade de acompanhar, existem diversas opções no mercado, para um mesmo objectivo, e tornasse determinante o processo de tomada de decisão sobre qual tecnologia adoptar para determinado objectivo. O alvo de estudo desta dissertação de mestrado, é uma das tecnologias, que últimamente tem ganho especial relevo, quando aplicada ao ambiente industrial, o RFID (Radio Frequency Identification Devices). Na presente dissertação, foi efectuado um levantamento do estado da arte, na área da identificação automática, com especial foco no RFID. Esta revisão bibliográfica teve como principal objectivo perceber quais as tecnologias concorrentes do RFID, e explorar quais as suas principais características tecnológicas e funcionais, bem como as vantagens no uso desta tecnologia de forma a sustentar a implementação de um sistema protótipo de gestão de armazém. O contributo final da dissertação, consiste numa aplicação que tem como principal objectvo simular os fluxos de infomação resultantes dos fluxos fisícos de materiais em ambiente de armazém. Foi também tido em conta no desenvolvimento da aplicação, a demonstração de algumas das mais valias que esta tecnologia pode trazer para a gestão de armazéns. Para implementação da aplicação destaca-se a utilização da arquitectura MVC (Model-view-controlador), em ambiente web, para permitir uma descentalização do software no ambiente indoor do armazém.
Resumo:
OBJECTIVES: To evaluate the short- and medium-term results of prostatic arterial embolisation (PAE) for benign prostatic hyperplasia (BPH). METHODS: This was a prospective non-randomised study including 255 patients diagnosed with BPH and moderate to severe lower urinary tract symptoms after failure of medical treatment for at least 6 months. The patients underwent PAE between March 2009 and April 2012. Technical success is when selective prostatic arterial embolisation is completed in at least one pelvic side. Clinical success was defined as improving symptoms and quality of life. Evaluation was performed before PAE and at 1, 3, 6 and every 6 months thereafter with the International Prostate Symptom Score (IPSS), quality of life (QoL), International Index of Erectile Function (IIEF), uroflowmetry, prostatic specific antigen (PSA) and volume. Non-spherical polyvinyl alcohol particles were used. RESULTS: PAE was technically successful in 250 patients (97.9 %). Mean follow-up, in 238 patients, was 10 months (range 1-36). Cumulative rates of clinical success were 81.9 %, 80.7 %, 77.9 %, 75.2 %, 72.0 %, 72.0 %, 72.0 % and 72.0 % at 1, 3, 6, 12, 18, 24, 30 and 36 months, respectively. There was one major complication. CONCLUSIONS: PAE is a procedure with good results for BPH patients with moderate to severe LUTS after failure of medical therapy. KEY POINTS: • Prostatic artery embolisation offers minimally invasive therapy for benign prostatic hyperplasia. • Prostatic artery embolisation is a challenging procedure because of vascular anatomical variations. • PAE is a promising new technique that has shown good results.
Resumo:
Thesis submitted to the Instituto Superior de Estatística e Gestão de Informação da Universidade Nova de Lisboa in partial fulfillment of the requirements for the Degree of Doctor of Philosophy in Information Management – Geographic Information Systems
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Dissertação para obtenção do Grau de Doutor em Ciência e Engenharia de Materiais
Resumo:
Dissertation to obtain the degree of Doctor of Philosophy in Biomedical Engineering
Resumo:
Breast cancer is the most common type of cancer among women all over the world. An important issue that is not commonly addressed in breast cancer imaging literature is the importance of imaging the underarm region—where up to 80% of breast cancer cells can metastasise to. The first axillary lymph nodes to receive drainage from the primary tumour in the breast are called Sentinel Node. If cancer cells are found in the Sentinel Node, there is an increased risk of metastatic breast cancer which makes this evaluation crucial to decide what follow-up exams and therapy to follow. However, non-invasive detection of cancer cells in the lymph nodes is often inconclusive, leading to the surgical removal of too many nodes which causes adverse side-effects for patients. Microwave Imaging is one of the most promising non-invasive imaging modalities for breast cancer early screening and monitoring. This novel study tests the feasibility of imaging the axilla region by means of the simulation of an Ultra-Wideband Microwave Imaging system. Simulations of such system are completed in several 2D underarm models that mimic the axilla. Initial imaging results are obtained by means of processing the simulated backscattered signals by eliminating artefacts caused by the skin and beamforming the processed signals in order to time-align all the signals recorded at each antenna. In this dissertation several image formation algorithms are implemented and compared by visual inspection of the resulting images and through a range of performance metrics, such as Signal-to-Clutter Ratio and FullWidth Half Maximum calculations. The results in this study showed that Microwave Imaging is a promising technique that might allow to identify the presence and location of metastasised cancer cells in axillary lymph nodes, enabling the non-invasive evaluation of breast cancer staging.
Resumo:
There were two main objectives in this thesis investigation, first, the production, characterisation, in vitro degradation and release studies of double walled microspheres for drug release control. The second one, and the most challenging, was the production of double walled nanospheres, also for drug control delivery. The spheres were produced using two polymers, the Poly(L-lactide)Acid, PLLA, and the Poly(L-lactide-co-glycolic)Acid, PLGA.Afterwards, a model drug, Meloxicam, which is an antiinflammatory drug, was encapsulated into the particles. Micro and nanospheres were produced by the solvent extraction/evaporation method, where perfect spherical particles were obtained. By varying the polymers PLLA/PLGA mass ratio, different core and shell composition, as well as several shell and core thickness were observed. In the particles with a PLLA/PLGA mass ratio 1:1, the shell is composed by PLLA and the core by PLGA. It was also verified that the Meloxicam has a tendency to be distributed in the PLGA layer. Micro and nanoparticles were characterised in morphology, size, polymer cristalinity properties and drug distribution. Particles degradation studies was performed, where the particles in a PVA solution of pH 7,4 where placed in an incubator, during approximately 40 days, at 120rpm, and 37ºC, simulating, as much as possible, the human body environment. From these studies, the conclusion was that particles containing a PLGA shell and a PLLA core degrade more rapidly, due to the fact that PLLA is more hydrophobic than the PLGA. Concerning the drug release controlled results, done also for 40 and 50 days, they showed that the microspheres containing a shell of PLLA release more slowly than when the shell is composed of PLGA. This result was predictable, since the drug is solubilised in the PLGA polymer and so, in that case, the PLLA shell works like a barrier between the drug and the outer medium. Another positive aspect presented by this study is the lower initial burst effect, obtained when using double walled particles, which is one of the advantages of the same. In a second part of this investigation, the production of the nanospheres was the main goal, since it was not yet accomplished by other authors or investigators. After several studies, referring to the speed, time and type of agitation, as well as, the concentration and volume of the first aqueous solution of poly-vinyl-alcohol (PVA) during the process of solvent extraction/evaporation it was possible to obtain double walled nanospheres.(...)
Resumo:
Polymeric particulate-systems are of great relevance due to their possible biomedical applications, among them as carriers for the nano- or microencapsulation of drugs. However, due to their unique specific properties, namely small size range, toxicity issues must be discarded before allowing its use on health-related applications. Several polymers, as poly(methyl methacrylate) (PMMA), have proved to be suitable for the preparation of particulate-systems. However, a major drawback of its use refers to incomplete drug release from particles matrix. Recent strategies to improve PMMA release properties mention the inclusion of other acrylic polymers as Eudragit (EUD) on particles formulation. Though PMMA and EUD are accepted by the FDA as biocompatible, their safety on particle composition lacks sufficient toxicological data. The main objective of this thesis was to evaluate the biological effects of engineered acrylic particulate-systems. Preparation, physicochemical characterization and in vitro toxicity evaluation were assessed on PMMA and PMMA-EUD (50:50) particles. The emulsification-solvent evaporation methodology allowed the preparation of particles with spherical and smooth surfaces within the micrometer range (±500 nm), opposing surface charges and different levels of hydrophobicity. It was observed that particles physicochemical properties (size and charge) were influenced by biological media composition, such as serum concentration, ionic strength or pH. In what concerns to the in vitro toxicological studies, particle cellular uptake was observed on different cell lines (macrophages, osteoblasts and fibroblasts). Cytotoxicity effects were only found after 72 h of cells exposure to the particles, while no oxidative damage was observed neither on osteoblasts nor fibroblasts. Also, no genotoxicity was found in fibroblast using the comet assay to assess DNA damage. This observation should be further confirmed with other validated genotoxicity assays (e.g. Micronucleus Assay). The present study suggests that the evaluated acrylic particles are biocompatible, showing promising biological properties for potential use as carriers in drug-delivery systems.