879 resultados para Residual diagnostics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho tem como objetivo o estudo da execução residual na tutela dos interesses individuais homogêneos e as questões procedimentais que envolvem o instituto no direito processual brasileiro. Foram abordados aspectos relativos aos fundamentos do instituto no direito brasileiro, os requisitos para sua aplicação e o procedimento para a restituição da indenização devida aos indivíduos nos casos em que esta se faz necessária.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present some of the first science data with the new Keck/MOSFIRE instrument to test the effectiveness of different AGN/SF diagnostics at z ~ 1.5. MOSFIRE spectra were obtained in three H-band multi-slit masks in the GOODS-S field, resulting in 2 hr exposures of 36 emission-line galaxies. We compare X-ray data with the traditional emission-line ratio diagnostics and the alternative mass-excitation and color-excitation diagrams, combining new MOSFIRE infrared data with previous HST/WFC3 infrared spectra (from the 3D-HST survey) and multiwavelength photometry. We demonstrate that a high [O III]/Hβ ratio is insufficient as an active galactic nucleus (AGN) indicator at z > 1. For the four X-ray-detected galaxies, the classic diagnostics ([O III]/Hβ versus [N II]/Hα and [S II]/Hα) remain consistent with X-ray AGN/SF classification. The X-ray data also suggest that "composite" galaxies (with intermediate AGN/SF classification) host bona fide AGNs. Nearly ~2/3 of the z ~ 1.5 emission-line galaxies have nuclear activity detected by either X-rays or the classic diagnostics. Compared to the X-ray and line ratio classifications, the mass-excitation method remains effective at z > 1, but we show that the color-excitation method requires a new calibration to successfully identify AGNs at these redshifts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To define a range of normality for the vectorial parameters Ocular Residual Astigmatism (ORA) and topography disparity (TD) and to evaluate their relationship with visual, refractive, anterior and posterior corneal curvature, pachymetric and corneal volume data in normal healthy eyes. Methods: This study comprised a total of 101 consecutive normal healthy eyes of 101 patients ranging in age from 15 to 64 years old. In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system (Pentacam system Oculus Optikgeräte GmbH). Anterior corneal topographic data were imported from the Pentacam system to the iASSORT software (ASSORT Pty. Ltd.), which allowed the calculation of the ocular residual astigmatism (ORA) and topography disparity (TD). Linear regression analysis was used for obtaining a linear expression relating ORA and posterior corneal astigmatism (PCA). Results: Mean magnitude of ORA was 0.79 D (SD: 0.43), with a normality range from 0 to 1.63 D. 90 eyes (89.1%) showed against-the-rule ORA. A weak although statistically significant correlation was found between the magnitudes of posterior corneal astigmatism and ORA (r = 0.34, p < 0.01). Regression analysis showed the presence of a linear relationship between these two variables, although with a very limited predictability (R2: 0.08). Mean magnitude of TD was 0.89 D (SD: 0.50), with a normality range from 0 to 1.87 D. Conclusion: The magnitude of the vector parameters ORA and TD is lower than 1.9 D in the healthy human eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To compare the manifest refractive cylinder (MRC) predictability of myopic astigmatism laser in situ keratomileusis (LASIK) between eyes with low and high ocular residual astigmatism (ORA). Setting: London Vision Clinic, London, United Kingdom. Design: Retrospective case study. Methods: The ORA was considered the vector difference between the MRC and the corneal astigmatism. The index of success (IoS), difference vector ÷ MRC, was analyzed for different groups as follows: stage 1, low ORA (ORA ÷ MRC <1), high ORA (ORA ÷ MRC ≥1); stage 2, low ORA group reduced to match the high ORA group for MRC; stage 3, grouped by ORA magnitude with low ORA (<0.50 diopters [D]), mid ORA (0.50 to 1.24 D), and high ORA (≥1.25 D); stage 4, high ORA group subdivided into low (<0.75 D) and high (≥0.75 D) corneal astigmatism. Results: For stage 1, the mean preoperative MRC and mean IoS were −1.32 D ± 0.65 (SD) (range −0.55 to −3.77 D) and 0.27, respectively, for low ORA and −0.79 ± 0.20 D (range −0.56 to −2.05 D) and 0.37, respectively, for high ORA. For stage 2, the mean IoS increased to 0.32 for low ORA. For stage 3, the mean IoS was 0.28, 0.29, and 0.31 for low ORA, mid ORA, and high ORA, respectively. For stage 4, the mean IoS was 0.20 for high ORA/low corneal astigmatism and 0.35 for high ORA/high corneal astigmatism. Conclusions: The MRC predictability was slightly worse in eyes with high ORA when grouped by the ORA ÷ MRC. Matching for the MRC and grouping by ORA magnitude resulted in similar predictability; however, eyes with high ORA and high corneal astigmatism were less predictable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. We aimed to characterize the distribution of the vector parameters ocular residual astigmatism (ORA) and topography disparity (TD) in a sample of clinical and subclinical keratoconus eyes, and to evaluate their diagnostic value to discriminate between these conditions and healthy corneas. Methods. This study comprised a total of 43 keratoconic eyes (27 patients, 17–73 years) (keratoconus group), 11 subclinical keratoconus eyes (eight patients, 11–54 years) (subclinical keratoconus group) and 101 healthy eyes (101 patients, 15–64 years) (control group). In all cases, a complete corneal analysis was performed using a Scheimpflug photography-based topography system. Anterior corneal topographic data was imported from it to the iASSORT software (ASSORT Pty. Ltd), which allowed the calculation of ORA and TD. Results. Mean magnitude of the ORA was 3.23 ± 2.38, 1.16 ± 0.50 and 0.79 ± 0.43 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Mean magnitude of the TD was 9.04 ± 8.08, 2.69 ± 2.42 and 0.89 ± 0.50 D in the keratoconus, subclinical keratoconus and control groups, respectively (p < 0.001). Good diagnostic performance of ORA (cutoff point: 1.21 D, sensitivity 83.7 %, specificity 87.1 %) and TD (cutoff point: 1.64 D, sensitivity 93.3 %, specificity 92.1 %) was found for the detection of keratoconus. The diagnostic ability of these parameters for the detection of subclinical keratoconus was more limited (ORA: cutoff 1.17 D, sensitivity 60.0 %, specificity 84.2 %; TD: cutoff 1.29 D, sensitivity 80.0 %, specificity 80.2 %). Conclusion. The vector parameters ORA and TD are able to discriminate with good levels of precision between keratoconus and healthy corneas. For the detection of subclinical keratoconus, only TD seems to be valid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper summarizes the results of an experimental research to assess the residual mechanical properties of an ordinary concrete after fire. It was studied the influence of the cooling process, the maximum temperature that the concrete was subjected to and the loading level on the residual mechanical properties of calcareous and granite aggregate concretes. The properties studied were the residual compressive, tensile, splitting and flexural strengths and modulus of elasticity. Four levels of temperature; 20, 300, 500 and 700ºC; two loading levels (0.3f and 0.7fcd) and two cooling processes (cooling in the air and by water jet) were tested. The high temperatures attained and the sudden cooling down process on the concrete showed a negative effect on its residual mechanical properties. This effect was more notorious on the residual compression strength than in the other mechanical properties

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of climate change and the growing demand for water for domestic, industrial, agricultural and recreational activities have been led the use of treated wastewater (reclaimed water) for such applications. The artificial recharge of aquifers with treated wastewater can be an alternative way for restoring underground water volumes that can be used for satisfying some activities, particularly in water shortage areas or where their quality is not suitable for use. After a two-year monitoring period in the Vila Fernando WWTP (Guarda, Portugal), the characteristics of the treated effluent suggest that it could be used for infiltration for aquifer recharge. A multi-criteria analysis based on GIS was developed for site location of infiltration sites. The procedure has involved the combination of six thematic maps and environmental, technical and economic criteria, over an area of 6687.1 ha. About 6.4 ha were selected for suitable sites for infiltration and one of these sites (Quinta de Gonçalo Martins, Guarda) was selected for collecting soil samples. The characterization of the soil indicates that is favorable to the infiltration of treated wastewater for artificial recharge of aquifers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

logitcprplot can be used after logistic regression for graphing a component-plus-residual plot (a.k.a. partial residual plot) for a given predictor, including a lowess, local polynomial, restricted cubic spline, fractional polynomial, penalized spline, regression spline, running line, or adaptive variable span running line smooth

Relevância:

20.00% 20.00%

Publicador:

Resumo:

cprplot2 is a variation of official Stata's cprplot and is used for graphing component-plus-residual plots (a.k.a. partial residual plots). Additional features (compared to cprplot): (1) cprplot2 can handle variables that enter the model repeatedly via different transformations (for example, polynomials). (2) cprplot2 can display component-plus-residual plots using the original units for transformed variables in the model. (3) A wrapper is provided to quickly display several component-plus-residual plots in a single image.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Reprinted from the Physical review, n. s., vol. XVI, no. 4, October, 1920."

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliographical references (p. 24).