999 resultados para Pour Thru method
Resumo:
An ELISA Inhibition Method (EIM) was proposed for the serologic diagnosis of dengue, comparing its results with the Hemagglutination Inhibition (HI) and the IgM capture-ELISA (MAC-ELISA). Advantages and disadvantages of both methods are discussed according to sensitivity, specificity, performance and usefulness. As a conclusion we recommend the complementary inclusion of the EIM and MAC-ELISA substituting the HI for laboratories engaged in the diagnosis and surveillance of dengue.
Resumo:
A rapid and simple technique for the purification of Toxoplasma gondii tachyzoites was developed. Highly purified parasites were obtained from the peritoneal exudates of infected mice by means of two consecutive discontinous sucrose gradients run at low speed (10,000xg, 30 min). Parasites obtained by this method conserved its biological activity. Hybridizations tudies with DNA from healthy mice and from purified tachyzoites preparations demonstrated that Toxoplasma gondii tachyzoites DNA could be obtained with better than 90 per cents purity. Preliminary studies with DNA endonucleases showed the presence in the tachyzoites genome of highly repetitives sequences.
Resumo:
TNF family ligands and receptors fulfill a number of functions, mainly in the immune system. For example, the ligands BAFF and APRIL control growth and survival of mature Β cells at various stages of differentiation. TNF family ligands usually form homotrimers, but heteromers have also been described for lymphotoxin α1β2 and for BAFF and APRIL. Interestingly, twenty BAFF homotrimers can assemble into virus-like particles coined BAFF 60-mer, which are superior to BAFF 3-mer regarding their ability to signal in primary Β cells. A screen was performed in 293T cells, by co-transfecting differently tagged ligands, to identify six novel heteromers. The specificity of these novel heteromers, however, did not correspond to that of orphan receptors in the TNFR family. Little is known about heteromers of BAFF and APRIL, in particular their receptor-binding specificity and their ability to signal. A method to produce and purify heteromers of defined stoechiometry was developed, and the resulting reagents were used to demonstrate that BAFF2APRIL, like BAFF, binds to all BAFF receptors - namely BAFFR, TACI and Β CM A -, while APRIL2BAFF and APRIL only binds to TACI and BCMA. Heteromers could signal via their cognate receptors, sometimes as potently and sometimes less potently than homomers, depending on the receptors. A promising system to measure the activity of single-chain homo- and heteromers in vivo was set up: it measures mature Β cell rescue upon administration of single-chain ligands into BAFF-ko mice. To tackle the question of the physiological importance of BAFF 60-mer, a point mutation that prevents assembly of mouse BAFF into 60-mer while retaining its ability to form trimers was identified. This mutation (E247K) was introduced by homologous recombination into mouse embryonic stem cells that are now being used to generate knock-in mice. Results obtained in this work will help to better understand the role of various BAFF and APRIL forms that are elevated in a several autoimmune diseases. - Les ligands et récepteurs de la famille du TNF joue un rôle prédominant dans le système immunitaire. Par exemple, les ligands BAFF et APRIL contrôlent la croissance et la survie des cellules Β matures à différents stades de différenciation. Ces ligands existent souvent sous forme d'homotrimères (3-mer), bien que des héteromères aient été décrits pour la lymphotoxine α1β2 et pour BAFF et APRIL. Dans le cas de BAFF, vingt trimères peuvent, telle une particule virale, s'assembler en 60-mer qui surpasse le 3-mer pour signaler dans des cellules Β primaires. Un crible effectué dans des cellules 293T, par co-transfection de ligands différemment marqués, a permis d'identifier six nouveaux heteromères dont la spécificité n'a, hélas, pas correspondu à celle d'un récepteur orphelin de la famille du TNFR. Les connaissances sur la spécificité de liaison aux récepteurs et la capacité à signaler des heteromères de BAFF et d'APRIL sont fragmentaires. Une méthode pour produire et purifier des heteromères "simple chaîne" de stoechiométrie déterminée a été mise au point, et les réactifs ainsi obtenus utilisés pour démontrer que BAFF2APRIL, comme BAFF, lie tous les récepteurs de BAFF - c'est-à-dire BAFFR, TACI et BCMA -, alors qu'APRIL2BAFF et APRIL ne lient que TACI et BCMA. Les héteromères peuvent transmettre des signaux, parfois aussi bien et parfois plus faiblement que les homomères, selon les récepteurs. Un système prometteur pour mesurer l'activité des ligands simple chaîne in vivo a été mis au point. Il mesure la réapparition de cellules Β matures dans des souris déficientes pour BAFF après administration des ligands. Pour s'attaquer à la question de l'importance physiologique du 60-mer de BAFF, ime mutation empêchant l'assemblage en 60-mer sans affecter la capacité à former des trimères a été identifiée. Cette mutation (E247K) a été introduite par recombinaison homologue dans des cellules souches embryonnaires de souris qui sont utilisées pour obtenir des souris déficientes en BAFF 60-mer. Les résultats de ces travaux contribueront à mieux cerner le rôle des différentes formes de BAFF et d'APRIL produites en excès dans plusieurs maladies auto-immunes.
Resumo:
RESUME Durant les dernières années, les méthodes électriques ont souvent été utilisées pour l'investigation des structures de subsurface. L'imagerie électrique (Electrical Resistivity Tomography, ERT) est une technique de prospection non-invasive et spatialement intégrée. La méthode ERT a subi des améliorations significatives avec le développement de nouveaux algorithmes d'inversion et le perfectionnement des techniques d'acquisition. La technologie multicanale et les ordinateurs de dernière génération permettent la collecte et le traitement de données en quelques heures. Les domaines d'application sont nombreux et divers: géologie et hydrogéologie, génie civil et géotechnique, archéologie et études environnementales. En particulier, les méthodes électriques sont souvent employées dans l'étude hydrologique de la zone vadose. Le but de ce travail est le développement d'un système de monitorage 3D automatique, non- invasif, fiable, peu coûteux, basé sur une technique multicanale et approprié pour suivre les variations de résistivité électrique dans le sous-sol lors d'événements pluvieux. En raison des limitations techniques et afin d'éviter toute perturbation physique dans la subsurface, ce dispositif de mesure emploie une installation non-conventionnelle, où toutes les électrodes de courant sont placées au bord de la zone d'étude. Le dispositif le plus approprié pour suivre les variations verticales et latérales de la résistivité électrique à partir d'une installation permanente a été choisi à l'aide de modélisations numériques. Les résultats démontrent que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle et plus apte à détecter les variations latérales et verticales de la résistivité électrique, et cela malgré la configuration non-conventionnelle des électrodes. Pour tester l'efficacité du système proposé, des données de terrain ont été collectées sur un site d'étude expérimental. La technique de monitorage utilisée permet de suivre le processus d'infiltration 3D pendant des événements pluvieux. Une bonne corrélation est observée entre les résultats de modélisation numérique et les données de terrain, confirmant par ailleurs que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle. La nouvelle technique de monitorage 3D de résistivité électrique permet de caractériser les zones d'écoulement préférentiel et de caractériser le rôle de la lithologie et de la pédologie de manière quantitative dans les processus hydrologiques responsables d'écoulement de crue. ABSTRACT During the last years, electrical methods were often used for the investigation of subsurface structures. Electrical resistivity tomography (ERT) has been reported to be a useful non-invasive and spatially integrative prospecting technique. The ERT method provides significant improvements, with the developments of new inversion algorithms, and the increasing efficiency of data collection techniques. Multichannel technology and powerful computers allow collecting and processing resistivity data within few hours. Application domains are numerous and varied: geology and hydrogeology, civil engineering and geotechnics, archaeology and environmental studies. In particular, electrical methods are commonly used in hydrological studies of the vadose zone. The aim of this study was to develop a multichannel, automatic, non-invasive, reliable and inexpensive 3D monitoring system designed to follow electrical resistivity variations in soil during rainfall. Because of technical limitations and in order to not disturb the subsurface, the proposed measurement device uses a non-conventional electrode set-up, where all the current electrodes are located near the edges of the survey grid. Using numerical modelling, the most appropriate arrays were selected to detect vertical and lateral variations of the electrical resistivity in the framework of a permanent surveying installation system. The results show that a pole-dipole array has a better resolution than a pole-pole array and can successfully follow vertical and lateral resistivity variations despite the non-conventional electrode configuration used. Field data are then collected at a test site to assess the efficiency of the proposed monitoring technique. The system allows following the 3D infiltration processes during a rainfall event. A good correlation between the results of numerical modelling and field data results can be observed since the field pole-dipole data give a better resolution image than the pole-pole data. The new device and technique makes it possible to better characterize the zones of preferential flow and to quantify the role of lithology and pedology in flood- generating hydrological processes.
Resumo:
Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.
Resumo:
Objectifs: Evaluer la faisabilité et l'évolution de la pratique ambulatoire des procédures endovasculaires pour traitement des artériopathies des membres inférieurs . Matériels et méthodes: 89 patients ont bénéficié d'une procédure endovasculaire ambulatoire (séjour hospitalier de moins de 24 heures) pour traitement d'une artériopathie desmembres inférieurs entre janvier 2005 et décembre 2005. Sont étudiés, le stade de l'artériopathie, la complexité des lésions, le type de procédure, lesco-morbidités, les complications, la reconversion en hospitalisation. Résultats: La majorité des patients présentait une artériopathie de stade de II (95%). Les lésions des artères fémorales superficielles représentaient 45% des procédures etcelles des axes iliaques 41%. La majorité des lésions étaient des sténoses (83%) de TASC a ou B. Cependant, l'évolution au court du temps montre que deslésions de plus en plus complexes étaient traitées en ambulatoire. La taille de l'introducteur était de 6 F dans 82% des cas. Le succès technique était de 98% et letaux des complications de 4,2%. Le taux de reconversion en hospitalisation était de 5,2%. Conclusion: Les procédures endovasculaires pour artériopathies des membres inférieurs de stade II peuvent être faites en ambulatoire y compris pour des lésions complexesavec un taux de complication et un taux de reconversion faibles.
Resumo:
BACKGROUND: Iron deficiency is a common and undertreated problem in inflammatory bowel disease (IBD). AIM: To develop an online tool to support treatment choice at the patient-specific level. METHODS: Using the RAND/UCLA Appropriateness Method (RUAM), a European expert panel assessed the appropriateness of treatment regimens for a variety of clinical scenarios in patients with non-anaemic iron deficiency (NAID) and iron deficiency anaemia (IDA). Treatment options included adjustment of IBD medication only, oral iron supplementation, high-/low-dose intravenous (IV) regimens, IV iron plus erythropoietin-stimulating agent (ESA), and blood transfusion. The panel process consisted of two individual rating rounds (1148 treatment indications; 9-point scale) and three plenary discussion meetings. RESULTS: The panel reached agreement on 71% of treatment indications. 'No treatment' was never considered appropriate, and repeat treatment after previous failure was generally discouraged. For 98% of scenarios, at least one treatment was appropriate. Adjustment of IBD medication was deemed appropriate in all patients with active disease. Use of oral iron was mainly considered an option in NAID and mildly anaemic patients without disease activity. IV regimens were often judged appropriate, with high-dose IV iron being the preferred option in 77% of IDA scenarios. Blood transfusion and IV+ESA were indicated in exceptional cases only. CONCLUSIONS: The RUAM revealed high agreement amongst experts on the management of iron deficiency in patients with IBD. High-dose IV iron was more often considered appropriate than other options. To facilitate dissemination of the recommendations, panel outcomes were embedded in an online tool, accessible via http://ferroscope.com/.