963 resultados para Photon asymmetry
Resumo:
Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.
Resumo:
Joining of components with structural adhesives is currently one of the most widespread techniques for advanced structures (e.g., aerospace or aeronautical). Adhesive bonding does not involve drilling operations and it distributes the load over a larger area than mechanical joints. However, peak stresses tend to develop near the overlap edges because of differential straining of the adherends and load asymmetry. As a result, premature failures can be expected, especially for brittle adhesives. Moreover, bonded joints are very sensitive to the surface treatment of the material, service temperature, humidity and ageing. To surpass these limitations, the combination of adhesive bonding with spot-welding is a choice to be considered, adding a few advantages like superior static strength and stiffness, higher peeling and fatigue strength and easier fabrication, as fixtures during the adhesive curing are not needed. The experimental and numerical study presented here evaluates hybrid spot-welded/bonded single-lap joints in comparison with the purely spot-welded and bonded equivalents. A parametric study on the overlap length (LO) allowed achieving different strength advantages, up to 58% compared to spot-welded joints and 24% over bonded joints. The Finite Element Method (FEM) and Cohesive Zone Models (CZM) for damage growth were also tested in Abaqus® to evaluate this technique for strength prediction, showing accurate estimations for all kinds of joints.
Resumo:
A new inherently chiral calix[4]arene ICC 1 has been disclosed. The dissymmetry of 1 is generated from a chirality plane in the quinol moiety of a 1,3-bridged bicyclic calix[4]arene. ICC 1 has been resolved by enantioselective HPLC, and the chiroptical properties of both isolated antipodes (pS)-1 and (pR)-1 confirm their enantiomeric nature. The absolute configuration of the (pS)-1/(pR)-1 enantiomeric pair was established through time-dependent density functional theory (TDDFT) calculations of electronic circular dichroism (CD) spectra. (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
It has been pointed out recently that current experiments still allow for a two Higgs doublet model where the hbb¯ coupling (kDmb/v) is negative; a sign opposite to that of the Standard Model. Due to the importance of delayed decoupling in the hH+H− coupling, h→γγ improved measurements will have a strong impact on this issue. For the same reason, measurements or even bounds on h→Zγ are potentially interesting. In this article, we revisit this problem, highlighting the crucial importance of h→VV, which can be understood with simple arguments. We show that the impacts on kD<0 models of both h→bb¯ and h→τ+τ− are very sensitive to input values for the gluon fusion production mechanism; in contrast, h→γγ and h→Zγ are not. We also inquire if the search for h→Zγ and its interplay with h→γγ will impact the sign of the hbb¯ coupling. Finally, we study these issues in the context of the flipped two Higgs doublet model.
Resumo:
Since the first in vivo studies of cerebral function with radionuclides by Ingvar and Lassen, nuclear medicine (NM) brain applications have evolved dramatically, with marked improvements in both methods and tracers. Consequently it is now possible to assess not only cerebral blood flow and energy metabolism but also neurotransmission. Planar functional imaging was soon substituted by single-photon emission computed tomography (SPECT) and positron emission tomography (PET); it now has limited application in brain imaging, being reserved for the assessment of brain death.
Resumo:
Brain dopamine transporters imaging by Single Photon Emission Tomography (SPECT) with 123I-FP-CIT has become an important tool in the diagnosis and evaluation of parkinsonian syndromes, since this radiopharmaceutical exhibits high affinity for membrane transporters responsible for cellular reabsorption of dopamine on the striatum. However, Ordered Subset Expectation Maximization (OSEM) is the method recommended in the literature for imaging reconstruction. Filtered Back Projection (FBP) is still used due to its fast processing, even if it presents some disadvantages. The aim of this work is to investigate the influence of reconstruction parameters for FBP in semiquantification of Brain Studies with 123I-FPCIT compared with those obtained with OSEM recommended reconstruction.
Resumo:
Myocardial perfusion imaging (MPI) is used on a daily basis to access coronary blood flow in patients that are suspected or have known Coronary Artery Disease (CAD). A Single Photon Emission Computed Tomography (SPECT) or and Positron Emission Tomography (PET) scan are used to access regional blood flow quantification either at rest or stress, the imaging acquisition is connected to an Electrocardiogram (ECG) and it is able to determine and quantify other myocardial parameters like myocardial wall thickness and wall motion. PET is not used so broadly due to its high procedure cost, the proximity with cyclotron, where are produced the majority of radiopharmaceuticals used in PET, due to their shor thalf-life. This work is intended to carry out a review of the tests relating to radiopharmaceuticals that are used in clinical practice in SPECT or PET for assessment of myocardial perfusion, also focusing very promising radiopharmaceuticals that are under investigation or in clinical trials with great potential for conventional nuclear medicine or PET, proceeding to a comparative analysis of both techniques and respective radiopharmaceuticals used.
Resumo:
The acquisition of a Myocardial Perfusion image (MPI) is of great importance for the diagnosis of the coronary artery disease, since it allows to evaluate which areas of the heart aren’t being properly perfused, in rest and stress situations. This exam is greatly influenced by photon attenuation which creates image artifacts and affects quantification. The acquisition of a Computerized Tomography (CT) image makes it possible to get an atomic images which can be used to perform high-quality attenuation corrections of the radiopharmaceutical distribution, in the MPI image. Studies show that by using hybrid imaging to perform diagnosis of the coronary artery disease, there is an increase on the specificity when evaluating the perfusion of the right coronary artery (RCA). Using an iterative algorithm with a resolution recovery software for the reconstruction, which balances the image quality, the administered activity and the scanning time, we aim to evaluate the influence of attenuation correction on the MPI image and the outcome in perfusion quantification and imaging quality.
Resumo:
Motivated by the dark matter and the baryon asymmetry problems, we analyze a complex singlet extension of the Standard Model with a Z(2) symmetry (which provides a dark matter candidate). After a detailed two-loop calculation of the renormalization group equations for the new scalar sector, we study the radiative stability of the model up to a high energy scale (with the constraint that the 126 GeV Higgs boson found at the LHC is in the spectrum) and find it requires the existence of a new scalar state mixing with the Higgs with a mass larger than 140 GeV. This bound is not very sensitive to the cutoff scale as long as the latter is larger than 10(10) GeV. We then include all experimental and observational constraints/measurements from collider data, from dark matter direct detection experiments, and from the Planck satellite and in addition force stability at least up to the grand unified theory scale, to find that the lower bound is raised to about 170 GeV, while the dark matter particle must be heavier than about 50 GeV.
Resumo:
Photo-interpretation of aerial stereopairs of the Sintra region on the approx. 1/32 000 scale together with field work allowed the production of the present Tectonic Map of the Sintra region. It is now possible to separate structures which resulted from two different tectonic events: one, corresponding to the intrusion of the Late Cretaceous Sintra igneous diapir, and the other the Miocene compressive event, the most important tectonic inversion phase of the Lusitanian Basin. The former are present to the south, southeast and east of the intrusion and within the intrusion itself, affecting the peripheral granites and their contacts with the gabbro-syenite core. These structures comprehend: i) faults and conical fractures striking parallel to the massif boundary, which were intruded by dykes, ii) vertical faults and fractures of two conjugate sets, dextral NNW-SSE and sinistral NNE-SSW. These faults are certainly associated with the E-W striking massif's northwards directed thrust and indicate a N-S oriented horizontal maximum compressive stress. The Miocene compressive event reactivated most of the inherited structures as follows. The NNWSSE faults located on the Sintra southern platform were reactivated as dextral strike slip faults and the E-W thrust along the northern boundary of the massif was also reactivated. This thrust propagated to the east. It also enhanced the asymmetry of the rim-syncline, uplifted the massif and reactivated the NNE-SSW faults as sinistral lateral ramps, which also accommodated vertical throw. The present Tectonic Map of Sintra together with the available geophysical data (MOREIRA, 1984, KULLBERG et al., 1991, SILVA & MIRANDA, 1994) allowed reassessment of the models proposed for the emplacement of the Sintra, Sines and Monchique igneous massifs, which intruded during Late Cretaceous times along the deep dextral NNW-SSE oriented strike slip fault (RIBEIRO et al., 1979; TERRINHA, 1998; TERRINHA & KULLBERG, 1998).
Resumo:
Mestrado em Engenharia Informática
Resumo:
Radio link quality estimation is essential for protocols and mechanisms such as routing, mobility management and localization, particularly for low-power wireless networks such as wireless sensor networks. Commodity Link Quality Estimators (LQEs), e.g. PRR, RNP, ETX, four-bit and RSSI, can only provide a partial characterization of links as they ignore several link properties such as channel quality and stability. In this paper, we propose F-LQE (Fuzzy Link Quality Estimator, a holistic metric that estimates link quality on the basis of four link quality properties—packet delivery, asymmetry, stability, and channel quality—that are expressed and combined using Fuzzy Logic. We demonstrate through an extensive experimental analysis that F-LQE is more reliable than existing estimators (e.g., PRR, WMEWMA, ETX, RNP, and four-bit) as it provides a finer grain link classification. It is also more stable as it has lower coefficient of variation of link estimates. Importantly, we evaluate the impact of F-LQE on the performance of tree routing, specifically the CTP (Collection Tree Protocol). For this purpose, we adapted F-LQE to build a new routing metric for CTP, which we dubbed as F-LQE/RM. Extensive experimental results obtained with state-of-the-art widely used test-beds show that F-LQE/RM improves significantly CTP routing performance over four-bit (the default LQE of CTP) and ETX (another popular LQE). F-LQE/RM improves the end-to-end packet delivery by up to 16%, reduces the number of packet retransmissions by up to 32%, reduces the Hop count by up to 4%, and improves the topology stability by up to 47%.
Resumo:
A Thesis submitted for the co-tutelle degree of Doctor in Physics at Universidade Nova de Lisboa and Université Pierre et Marie Curie
Resumo:
1.Pre-assessment data of the patient A 2-year-old boy, weighing 15 kg was admitted with a history of limited mouth opening(inter-incisor distance of 6 mm), hypoplastic and retrognathic mandible (bird face deformity) and facial asymmetry from left temporomandibular joint ankylosis (TMJA). He was born at term, after an uneventful pregnancy, and there was no report of trauma during caesarean section. No other possible aetiologies were identified. He was scheduled for mandibular osteotomy. Preoperative ENT examination revealed adenotonsillar hypertrophy. 2. Anaesthetic Plan A fiberoptic nasal intubation was performed under deep inhalation anaesthesia with sevoflurane, with the patient breathing spontaneously. Midazolam (0.05 mg.kg-1) and alfentanil (0.03 mg.kg-1) were given and anaesthesia was maintained with O2/air and sevoflurane. No neuromuscular blocking agent was administered since the surgical team needed facial nerve monitoring. 3. Description of incident During surgery an accidental extubation occurred and an attempt was made to reintubate the trachea by direct laryngoscopy. Although the osteotomy was nearly completed, the vocal cords could not be visualized (Cormack-Lehane grade IV laryngoscopic view). 4. Solving the problem Re-intubation was finally accomplished with the flexible fiberscope and the procedure was concluded without any more incidents. Extubation was performed 24 hours postoperatively with the patient fully awake. After surgery mouth opening improved to inter-incisor gap of 15 mm. 5. Lessons learned and take home message Two airways issues present in this case can lead to difficultventilation and intubation: TMJA and adenotonsillar hypertrophy. These difficulties were anticipated and managed accordingly. The accidental extubation brought to our attention the fact that, even after surgical correction, this airway remains challenging. Even with intensive jaw stretchingexercises there is a high incidence of re-ankylosis, especially in younger patients. One should bear that in mind when anaesthetizing patients with TMJA.
Resumo:
RESUMO: A permeabilidade nasal (nasal patency) é um conceito importante na avaliação da função nasal. Pode ser explicado como uma medida do quanto a cavidade nasal está “aberta” e é determinada por fatores dependentes da sua estrutura anatómica que se relacionam com o fluxo e a resistência nasais e a existência de um fenómeno denominado ciclo nasal. Tradicionalmente, a avaliação da permeabilidade nasal baseia-se em indicadores subjetivos, nomeadamente Escalas Visuais Analógicas ou Scores de Sintomas, embora a sensação subjetiva de obstrução nasal seja difícil de quantificar e frequentemente não se correlacione com métodos mais objetivos de avaliação. A Rinometria Acústica (RA) tem adquirido um papel cada vez mais relevante na avaliação das alterações da permeabilidade nasal, pelo seu carácter não-invasivo, rápido, de fácil execução e por ser bem tolerada pelos pacientes. Contudo, não foram ainda publicados valores de referência para a população normal. Com o presente trabalho pretendeu-se determinar áreas transversais (AT) e volumes (Vol) da cavidade nasal em adultos saudáveis através de RA, em condições basais e após a administração de um fármaco descongestionante tópico nasal, relacionando estes parâmetros com variáveis demográficas e antropométricas. MATERIAL E MÉTODOS: O estudo foi realizado em 32 adultos jovens, de ambos os sexos (18 mulheres e 14 homens), com idade igual ou superior a 18 anos, não fumadores, sem patologias crónicas ou infeção recente das vias aéreas superiores. Para a execução do exame de RA foi utilizado o equipamento SRE2000 com Software RhinoScan Interacoustics, Dinamarca). O rinograma foi analisado em condições basais e após descongestionamento até aos 5 cm de distância da narina, obtendo-se os valores médios entre cavidade nasal direita e esquerda das áreas transversais (AT) dos entalhes registados (AT1 e AT2), a sua localização e volumes nasais a diferentes distâncias (Vol.0-2; Vol.2-5 e Vol.0-5). RESULTADOS: Os indivíduos do género masculino apresentaram valores significativamente superiores aos do género feminino em todos os parâmetros estudados. A administração do fármaco descongestionante tópico nasal provocou um aumento generalizado das AT e volumes nasais, traduzindo uma diminuição da congestão da mucosa nasal, mais acentuada posteriormente ao nível dos cornetos. A comparação entre fossas nasais (direita versus esquerda) após descongestionamento, eliminando o efeito do ciclo nasal, revelou simetria significativa. De uma forma geral, os parâmetros rinométricos estudados revelaram correlação positiva significativa com a altura. CONCLUSÃO: O estudo foi pioneiro para a população portuguesa e representa uma contribuição para a obtenção de valores de referência em adultos jovens. Estudos futuros em amostras de maior dimensão e representatividade são necessários para a obtenção de valores de referência com utilidade clínica e em investigação.--------------ABSTRACT: Nasal patency is an important concept in the evaluation of nasal function. It may be explained as a measure of how open the nasal cavity is, and it depends of anatomical aspects, that relate to nasal airflow, resistance and nasal cycle. Nasal patency evaluation is based in subjective indicators like visual analogical scales or symptom scores, but subjective sensation of nasal obstruction is difficult to quantify and usually doesn’t correlate with more objective methods of evaluation. Acoustic rhinometry has gained an increasingly relevant role in assessing changes in nasal patency, because it is noninvasive, fast and easy to perform and well tolerated by patients However, reference values for the normal population have not yet been published. The aim of the present study was to determine nasal cross-sectional areas and volumes in healthy adults by acoustic rhinometry, before and after administration of a topical nasal decongestant drug, correlating these parameters with demographic and anthropometric variables. MATERIAL E METHODS: The study was performed in 32 young adults (18 females and 14 males), aged 18 years old or more, non-smokers, without chronic diseases or recent airway infection. Acoustic rhinometry evaluation was performed using SRE2000 with RhinoScan software (Interacoustics, Denmark). Nasal cavities were assessed up to 5 cm distance from the nostril, before and after administration of the topical nasal decongestant drug, and mean cross-sectional areas of the notches, their location and mean volumes at different distances from nostril were measured. RESULTS: Males presented significant higher values than females for all rhinometric parameters studied. The decongestant drug, significantly increased all the rhinometric parameters evaluated, in particular those corresponding to the more posterior regions. Comparison between nasal cavities after nasal decongestion showed no significant asymmetry. Globally,a positive correlation was found between rhinometric parameters and height . CONCLUSION: This study was pioneer in the Portuguese population and represents a contribution to acoustic rhinometry reference values in young adults . Further studies, on larger and representative samples, are necessary in order to obtain reference values, useful both to clinical and research applications of this technique.