999 resultados para Mass budget (Geophysics)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to develop, validate, and compare 190 artificial intelligence-based models for predicting the body mass of chicks from 2 to 21 days of age subjected to different duration and intensities of thermal challenge. The experiment was conducted inside four climate-controlled wind tunnels using 210 chicks. A database containing 840 datasets (from 2 to 21-day-old chicks) - with the variables dry-bulb air temperature, duration of thermal stress (days), chick age (days), and the daily body mass of chicks - was used for network training, validation, and tests of models based on artificial neural networks (ANNs) and neuro-fuzzy networks (NFNs). The ANNs were most accurate in predicting the body mass of chicks from 2 to 21 days of age after they were subjected to the input variables, and they showed an R² of 0.9993 and a standard error of 4.62 g. The ANNs enable the simulation of different scenarios, which can assist in managerial decision-making, and they can be embedded in the heating control systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Massaräätälöinti on tärkeä osa nykyaikaista tuotestrategiaa. Massaräätälöinti mahdollistaa asiakaskohtaisesti muokattujen tuotteiden valmistuksen massatuotannon tehokkuudella. Massaräätälöinti edellyttää laajamittaista tietojärjestelmien hyväksikäyttöä, niin räätälöityjen tuotteiden mallinnuksessa, tuotteistuksessa kuin ylläpidossakin. Diplomityössä käsittelen taustatekijöitä jotka ovat johtaneet massaräätälöinnin syntyyn ja yleistymiseen. Käsittelyssä ovat myös erilaiset tavat toteuttaa massaräätälöintiä ja tietojärjestelmät jota tukevat massaräätälöintiä. Diplomityön empiirisessä osassa tarkastellaan Nokia Networksin tapaa toteuttaa massaräätälöintiä sekä esitellään tärkeimmät tätä tukevat järjestelmät. Empiirisen osan painopiste on kuitenkin hyvin vahvasti keskittynyt yhteen tuoterakenteiden osaan, joka on aiheuttanut haasteita Nokia Networksin massaräätälöintikonseptille. Tämä tuoterakenteen osa on valjastettu moneen erilaiseen käyttöön, mikä aiheuttaa ongelmia tietojärjestelmissä ja prosesseissa joihin se on vaikuttamassa. Työn tarkoituksena on kartoittaa kaikki ne ongelmat joita tämä tuoterakenteen osa aiheuttaa sulavalle massaräätälöinnin toteuttamiselle, niin yleisesti kuin järjestelmä- ja prosessimielessäkin. Työ on tehty osana laajamittaista projektia. Projektin tarkoituksena on kehittää uusi ja joustavampi ratkaisu tuoterakenteisiin, mandollistaen asiakaskohtaisten räätälöityjen tuotteiden valmistamisen, niin että se sopii Nokia Networksin järjestelmä sekä prosessi ympäristöön.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Manival near Grenoble (French Prealps) is a very active debris-flow torrent equipped with a large sediment trap (25 000 m3) protecting an urbanized alluvial fan from debris-flows. We began monitoring the sediment budget of the catchment controlled by the trap in Spring 2009. Terrestrial laser scanner is used for monitoring topographic changes in a small gully, the main channel, and the sediment trap. In the main channel, 39 cross-sections are surveyed after every event. Three periods of intense geomorphic activity are documented here. The first was induced by a convective storm in August 2009 which triggered a debris-flow that deposited ~1,800 m3 of sediment in the trap. The debris-flow originated in the upper reach of the main channel and our observations showed that sediment outputs were entirely supplied by channel scouring. Hillslope debris-flows were initiated on talus slopes, as revealed by terrestrial LiDAR resurveys; however they were disconnected to the main channel. The second and third periods of geomorphic activity were induced by long duration and low intensity rainfall events in September and October 2009 which generate small flow events with intense bedload transport. These events contribute to recharge the debris-flow channel with sediments by depositing important gravel dunes propagating from headwaters. The total recharge in the torrent subsequent to bedload transport events was estimated at 34% of the sediment erosion induced by the August debris-flow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARY : Peroxisome proliferator-activated receptor ß/δ protects against obesity by reducing dyslipidemia and insulin resistance via effects in various organs, including muscle, adipose tissue and liver. However, nothing is known about the function of PPARß in pancreas, a prime organ in the control of glucose homeostasis. To gain insight into so far hypothetical functions of this PPAR isotype in ß-cell function, we specifically ablated Pparß in the whole epithelial compartment of the pancreas. The mutated mice presented expanded ß-cell mass, possibly, this is due to increased burst of ß-cell proliferation at 2 weeks of age. These PPARß null pancreas mice exhibit hyperinsulinemia-hypoglycaemia starting at 4 weeks of age, due to hyperfunctionality of ß-cell. Gene expression profiling indicated a broad repressive function of PPARß impacting the vesicular and granular compartment, actin cytoskeleton, and metabolism of glucose and fatty acids. Analyses of insulin release from isolated islets revealed accelerated second-phase of glucose-stimulated insulin secretion. Higher levels of PKD and PKCS in mutated animals, in concert with F-actin disassembly, lead to an increased insulin secretion and its associated systemic effects. Enhanced palmitate potentiation of glucose-stimulated insulin secretion in PPARß mutant islets, suggests an important role of this receptor in lipid/glucose metabolism in ß-cell. Taken together, these results provide evidence for PPARß playing a repressive role on ß-cell growth and insulin exocytosis, and shed new light on its metabolic .action. RESUME : Le récepteur nucléaire PPARß (Peroxisome proliferator-activated receptor ß/δ) protège contre l'obésité en réduisant la dyslipidémie et la résistance à l'insuline dans différents organes, comme le muscle, le tissue adipeux et le foie. Cependant, il y a, à ce jour, très peu de connaissance par rapport au rôle de PPARß dans le pancréas, qui est un organe très important dans le contrôle homéostatique du glucose. Afin de comprendre le rôle de cet isotype de PPAR dans le fonctionnement des cellules beta du pancréas, nous avons invalidé le gène Pparß dans tout le compartiment pancréatique de la souris. Ces souris mutantes présentent une augmentation de la masse totale de cellules beta; Cela serait dû à une intense prolifération des cellules beta à 2 semaines après la naissance. Également, ces souris présentent une hyperinsulinémie et une hypoglycémie qui commencent à l'âge de 4 semaines; la raison de ce phénotype serait une hyperactivité des cellules beta. Le profil d'expression génique indique une fonction répressive globale de PPARß en se référant aux compartiments vésiculaire et granulaire, au cytosquelette d'actine, et au métabolisme du glucose et des acides gras. L'analyse de la sécrétion d'insuline par les cellules beta a démontré que la deuxième phase de sécrétion d'insuline après stimulation au glucose est augmentée. Les niveaux élevés de PKD et PKCS dans les îlots pancréatiques de souris mutantes, ainsi qu'une augmentation de la dépolymérisation des filaments d'active génèrent un surplus de sécrétion d'insuline après stimulation au glucose. Les îlots pancréatiques des souris mutantes secrètent plus d'insuline après stimulation au glucose et au palmitate que les îlots de souris contrôles. Ceci suggère un rôle important de PPARß dans le métabolisme des lipides et du glucose des cellules beta. En résumé, ces résultats mettent en évidence un rôle répressif de PPARß dans la croissance des cellules beta et dans l'exocytose d'insuline.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many Spanish destinations are now considering low cost airlines (LCA) important for attracting tourists. However, there is little evidence on the characteristics travelers using low cost airlines and their flight preferences. Typical segmentation of air travelers are business versus leisure travelers and business versus tourist fares. The aim of this paper is to obtain a deeper understanding of the demand of LCA through a segmentation analysis, based on 808 foreign travelers who used Girona airport, that focuses on low cost travelers’ valuations of different flight attributes and trip related characteristics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly sensitive ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method was developed for the quantification of buprenorphine and its major metabolite norbuprenorphine in human plasma. In order to speed up the process and decrease costs, sample preparation was performed by simple protein precipitation with acetonitrile. To the best of our knowledge, this is the first application of this extraction technique for the quantification of buprenorphine in plasma. Matrix effects were strongly reduced and selectivity increased by using an efficient chromatographic separation on a sub-2μm column (Acquity UPLC BEH C18 1.7μm, 2.1×50mm) in 5min with a gradient of ammonium formate 20mM pH 3.05 and acetonitrile as mobile phase at a flow rate of 0.4ml/min. Detection was made using a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The procedure was fully validated according to the latest Food and Drug Administration guidelines and the Société Française des Sciences et Techniques Pharmaceutiques. Very good results were obtained by using a stable isotope-labeled internal standard for each analyte, to compensate for the variability due to the extraction and ionization steps. The method was very sensitive with lower limits of quantification of 0.1ng/ml for buprenorphine and 0.25ng/ml for norbuprenorphine. The upper limit of quantification was 250ng/ml for both drugs. Trueness (98.4-113.7%), repeatability (1.9-7.7%), intermediate precision (2.6-7.9%) and internal standard-normalized matrix effects (94-101%) were in accordance with international recommendations. The procedure was successfully used to quantify plasma samples from patients included in a clinical pharmacogenetic study and can be transferred for routine therapeutic drug monitoring in clinical laboratories without further development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Common variants at only two loci, FTO and MC4R, have been reproducibly associated with body mass index (BMI) in humans. To identify additional loci, we conducted meta-analysis of 15 genome-wide association studies for BMI (n > 32,000) and followed up top signals in 14 additional cohorts (n > 59,000). We strongly confirm FTO and MC4R and identify six additional loci (P < 5 x 10(-8)): TMEM18, KCTD15, GNPDA2, SH2B1, MTCH2 and NEGR1 (where a 45-kb deletion polymorphism is a candidate causal variant). Several of the likely causal genes are highly expressed or known to act in the central nervous system (CNS), emphasizing, as in rare monogenic forms of obesity, the role of the CNS in predisposition to obesity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vaahdonestoaineiden haitallinen vaikutus hapen liukenemisnopeuteen biologisen puhdistamon jätevesissä on yleisesti tunnettua. Aineiden eri vaikutusmekanismien takia on silti vaikea etukäteen arvioida, miten ja kuinka paljon aineensiirto muuttuu. Työn tavoitteena oli saada tietoa vaahdonestoaineiden ja muiden pinta-aktiivisten aineiden vaikutuksesta kuplakokoon, kaasun tilavuusosuuteen ja kaasu-neste aineensiirtoon. Työn teoriaosassa on kuvailtu vaahdon muodostumiseen vaikuttavia tekijöitä sekä eri vaahdonestoaineiden vaikutusmekanismeja sellu- ja paperitehtaan jätevedessä. Edelleen on esitetty useita hapen siirtoa estäviä ja parantavia aineita. Työn kokeellisessa osassa tutkittiin kahdenkymmenenviiden eri pinta-aktiivisen aineen vaikutusta hapen liukenemisnopeuteen yksivaiheisessa kuplakolonnissa. Kokeet tehtiin kahdella pitoisuudella, kahdella eri kaasunjakolaitteella ja kolmella eri kaasun tyhjäputkinopeudella. Aineensiirtokokeiden rinnalla tutkittiin jätevesien laatu- ja fysikaalisiaominaisuuksia, niiden vaikutusta hapen liukenemisnopeuteen sekä testattavien koeaineiden vaikutusta fysikaalisin ominaisuuksiin. Kokeet osoittavat että pinta-aktiivisten aineiden vaikutus hapen aineensiirtoon vaihtelee riippuen kaasunjakolaitteesta ja aineen pitoisuuksista. Testatuista vaahdonestonaineista pienin negatiivinen vaikutus oli aineella AT 35 ja positiivinen vaikutustodettiin olevan vaahdonestoaineiden komponenteilla: P2, S1, F4 ja T9.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assessed the association between several cardiometabolic risk factors (CRFs) (blood pressure, LDL-cholesterol, HDL-cholesterol, triglycerides, uric acid, and glucose) in 390 young adults aged 19-20 years in Seychelles (Indian Ocean, Africa) and body mass index (BMI) measured either at the same time (cross-sectional analysis) or at the age of 12-15 years (longitudinal analysis). BMI tracked markedly between age of 12-15 and age of 19-20. BMI was strongly associated with all considered CRFs in both cross-sectional and longitudinal analyses, with some exceptions. Comparing overweight participants with those having a BMI below the age-specific median, the odds ratios for high blood pressure were 5.4/4.7 (male/female) cross-sectionally and 2.5/3.9 longitudinally (P < 0.05). Significant associations were also found for most other CRFs, with some exceptions. In linear regression analysis including both BMI at age of 12-15 and BMI at age of 19-20, only BMI at age of 19-20 remained significantly associated with most CRFs. We conclude that CRFs are predicted strongly by either current or past BMI levels in adolescents and young adults in this population. The observation that only current BMI remained associated with CRFs when including past and current levels together suggests that weight control at a later age may be effective in reducing CRFs in overweight children irrespective of past weight status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The establishment of legislative rules about explosives in the eighties has reduced the illicit use of military and civilian explosives. However, bomb-makers have rapidly taken advantage of substances easily accessible and intended for licit uses to produce their own explosives. This change in strategy has given rise to an increase of improvised explosive charges, which is moreover assisted by the ease of implementation of the recipes, widely available through open sources. While the nature of the explosive charges has evolved, instrumental methods currently used in routine, although more sensitive than before, have a limited power of discrimination and allow mostly the determination of the chemical nature of the substance. Isotope ratio mass spectrometry (IRMS) has been applied to a wide range of forensic materials. Conclusions drawn from the majority of the studies stress its high power of discrimination. Preliminary studies conducted so far on the isotopic analysis of intact explosives (pre-blast) have shown that samples with the same chemical composition and coming from different sources could be differentiated. The measurement of stable isotope ratios appears therefore as a new and remarkable analytical tool for the discrimination or the identification of a substance with a definite source. However, much research is still needed to assess the validity of the results in order to use them either in an operational prospect or in court. Through the isotopic study of black powders and ammonium nitrates, this research aims at evaluating the contribution of isotope ratio mass spectrometry to the investigation of explosives, both from a pre-blast and from a post-blast approach. More specifically, the goal of the research is to provide additional elements necessary to a valid interpretation of the results, when used in explosives investigation. This work includes a fundamental study on the variability of the isotopic profile of black powder and ammonium nitrate in both space and time. On one hand, the inter-variability between manufacturers and, particularly, the intra-variability within a manufacturer has been studied. On the other hand, the stability of the isotopic profile over time has been evaluated through the aging of these substances exposed to different environmental conditions. The second part of this project considers the applicability of this high-precision technology to traces and residues of explosives, taking account of the characteristics specific to the field, including their sampling, a probable isotopic fractionation during the explosion, and the interferences with the matrix of the site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes a fast gas chromatography/negative-ion chemical ionization tandem mass spectrometric assay (Fast GC/NICI-MS/MS) for analysis of tetrahydrocannabinol (THC), 11-hydroxy-tetrahydrocannabinol (THC-OH) and 11-nor-9-carboxy-tetrahydrocannabinol (THC-COOH) in whole blood. The cannabinoids were extracted from 500 microL of whole blood by a simple liquid-liquid extraction (LLE) and then derivatized by using trifluoroacetic anhydride (TFAA) and hexafluoro-2-propanol (HFIP) as fluorinated agents. Mass spectrometric detection of the analytes was performed in the selected reaction-monitoring mode on a triple quadrupole instrument after negative-ion chemical ionization. The assay was found to be linear in the concentration range of 0.5-20 ng/mL for THC and THC-OH, and of 2.5-100 ng/mL for THC-COOH. Repeatability and intermediate precision were found less than 12% for all concentrations tested. Under standard chromatographic conditions, the run cycle time would have been 15 min. By using fast conditions of separation, the assay analysis time has been reduced to 5 min, without compromising the chromatographic resolution. Finally, a simple approach for estimating the uncertainty measurement is presented.