955 resultados para Load flow, Optimization of power systems
Resumo:
Abstract: The objective of this work was to evaluate 41 microsatellite markers for heterologous amplifications in piracanjuba (Brycon orbignyanus). Some markers were tested for the first time. Loci were optimized for PCR conditions and applied to a sample of 49 individuals. Thirty-one loci resulted in PCR product formation, whereas ten loci yielded intelligible polymorphic patterns in the evaluated sample and can be used for amplifications in this species. From the evaluated markers, four loci (BoM1, BoM13, Bh6, and Bh16) are valid to be applied in the study of piracanjuba.
Resumo:
Diplomityön tarkoituksena oli parantaa Stora Enso Sachsenin siistausprosessissa tuotetun uusiomassan vaaleuden kehitystä ja tutkia siihen vaikuttavia tekijöitä. Työn kirjallisessa osassa käsiteltiin uusiomassan kuidutusta ja vaahdotussiistausprosessia, sekä keräyspaperin ominaisuuksia ja käyttöä paperiteollisuuden raaka-aineena. Kokeellisessa osassa keskityttiin modifioidun natriumsilikaatin annostuksenoptimointiin ja vaikutuksiin laboratorio- ja prosessioloissa, sekä kesäefektin vaikutuksen tutkimiseen kuidutuksessa ja flotaation eri vaiheissa. Natriumsilikaatin laboratoriotutkimuksessa havaittiin, että korkein vaaleus suhteellisesti pienimmällä laboratorioflotaation häviöllä saavutettiin korkeimmalla tutkitulla natriumsilikaatin annostuksella, joka oli 1,1 %. Korkea natriumsilikaattiannostus yhdistettyinä korkeisiin vetyperoksidiannostukseen, 0,5 %, sekä korkeaan kokonaisalkaliteettiin, 0.33 %, johti korkeimpaan massan vaaleuteen ja pienimpiin häviöihin. Laboratoriotutkimuksen pohjalta modifioidulla natriumsilikaatilla suoritettiin koeajoja prosessissa. Noin 1 % natriumsilikaatin annostuksella havaittiin parempi pH:n bufferointikyky, pienempi kalsiumkarbonaatin määrä flotaation primäärivaiheissa, sekä lievästi parempi massan vaaleus verrattuna prosessissa aiemmin käytettyyn standardinatriumsilikaattiin. Kesäefektitutkimuksessa havaittiin, että kesäefektillä on suurin vaikutus esiflotaation primäärivaiheeseen, sillä primäärivaiheessa kuitujen osuus on huomattavasti suurempi kuin sekundäärivaiheissa. Esiflotaation primäärivaiheen uusiomassojen laboratorioflotaatioiden avulla saavutettujen maksimivaaleuksien ero kesän ja talven välillä oli noin 1,5 %ISO. Kesäefektin ei havaittu suuresti vaikuttavan flotaation sekundäärivaiheisiin.
Resumo:
In this thesis, cleaning of ceramic filter media was studied. Mechanisms of fouling and dissolution of iron compounds, as well as methods for cleaning ceramic membranes fouled by iron deposits were studied in the literature part. Cleaning agents and different methods were closer examined in the experimental part of the thesis. Pyrite is found in the geologic strata. It is oxidized to form ferrous ions Fe(II) and ferric ions Fe(III). Fe(III) is further oxidized in the hydrolysis to form ferric hydroxide. Hematite and goethite, for instance, are naturally occurring iron oxidesand hydroxides. In contact with filter media, they can cause severe fouling, which common cleaning techniques competent enough to remove. Mechanisms for the dissolution of iron oxides include the ligand-promoted pathway and the proton-promoted pathway. The dissolution can also be reductive or non-reductive. The most efficient mechanism is the ligand-promoted reductive mechanism that comprises two stages: the induction period and the autocatalytic dissolution.Reducing agents(such as hydroquinone and hydroxylamine hydrochloride), chelating agents (such as EDTA) and organic acids are used for the removal of iron compounds. Oxalic acid is the most effective known cleaning agent for iron deposits. Since formulations are often more effective than organic acids, reducing agents or chelating agents alone, the citrate¿bicarbonate¿dithionite system among others is well studied in the literature. The cleaning is also enhanced with ultrasound and backpulsing.In the experimental part, oxalic acid and nitric acid were studied alone andin combinations. Also citric acid and ascorbic acid among other chemicals were tested. Soaking experiments, experiments with ultrasound and experiments for alternative methods to apply the cleaning solution on the filter samples were carried out. Permeability and ISO Brightness measurements were performed to examine the influence of the cleaning methods on the samples. Inductively coupled plasma optical emission spectroscopy (ICP-OES) analysis of the solutions was carried out to determine the dissolved metals.
Resumo:
The present work aimed at maximizing the number of plantlets obtained by the micropropagation of pineapple (Ananas comosus (L.) Merrill) cv. Pérola. Changes in benzylaminopurine (BAP) concentration, type of medium (liquid or solidified) and the type of explant in the proliferation phase were evaluated. Slips were used as the explant source, which consisted of axillary buds obtained after careful excision of the leaves. A Sterilization was done in the hood with ethanol (70%), for three minutes, followed by calcium hypochlorite (2%), for fifteen minutes, and three washes in sterile water. The explants were introduced in MS medium supplemented with 2mg L-1 BAP and maintained in a growth room at a 16h photoperiod (40 mmol.m-2.s-1), 27 ± 2ºC. After eight weeks, cultures were subcultured for multiplication in MS medium. The following treatments were tested: liquid x solidified medium with different BAP concentrations (0.0, 1.5 or 3.0 mg L-1), and the longitudinal cut, or not, of the shoot bud used as explant. The results showed that liquid medium supplemented with BAP at 1.5 mg L-1, associated with the longitudinal sectioning of the shoot bud used as explant presented the best results, maximizing shoot proliferation. On average, the best treatment would allow for an estimated production of 161,080 plantlets by the micropropagation of the axillary buds of one plant with eight slips and ten buds/slips, within a period of eight months.
Resumo:
The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.
Resumo:
Gas-liquid mass transfer is an important issue in the design and operation of many chemical unit operations. Despite its importance, the evaluation of gas-liquid mass transfer is not straightforward due to the complex nature of the phenomena involved. In this thesis gas-liquid mass transfer was evaluated in three different gas-liquid reactors in a traditional way by measuring the volumetric mass transfer coefficient (kLa). The studied reactors were a bubble column with a T-junction two-phase nozzle for gas dispersion, an industrial scale bubble column reactor for the oxidation of tetrahydroanthrahydroquinone and a concurrent downflow structured bed.The main drawback of this approach is that the obtained correlations give only the average volumetric mass transfer coefficient, which is dependent on average conditions. Moreover, the obtained correlations are valid only for the studied geometry and for the chemical system used in the measurements. In principle, a more fundamental approach is to estimate the interfacial area available for mass transfer from bubble size distributions obtained by solution of population balance equations. This approach has been used in this thesis by developing a population balance model for a bubble column together with phenomenological models for bubble breakage and coalescence. The parameters of the bubble breakage rate and coalescence rate models were estimated by comparing the measured and calculated bubble sizes. The coalescence models always have at least one experimental parameter. This is because the bubble coalescence depends on liquid composition in a way which is difficult to evaluate using known physical properties. The coalescence properties of some model solutions were evaluated by measuring the time that a bubble rests at the free liquid-gas interface before coalescing (the so-calledpersistence time or rest time). The measured persistence times range from 10 msup to 15 s depending on the solution. The coalescence was never found to be instantaneous. The bubble oscillates up and down at the interface at least a coupleof times before coalescence takes place. The measured persistence times were compared to coalescence times obtained by parameter fitting using measured bubble size distributions in a bubble column and a bubble column population balance model. For short persistence times, the persistence and coalescence times are in good agreement. For longer persistence times, however, the persistence times are at least an order of magnitude longer than the corresponding coalescence times from parameter fitting. This discrepancy may be attributed to the uncertainties concerning the estimation of energy dissipation rates, collision rates and mechanisms and contact times of the bubbles.
Resumo:
Recent laboratory studies have suggested that heart rate variability (HRV) may be an appropriate criterion for training load (TL) quantification. The aim of this study was to validate a novel HRV index that may be used to assess TL in field conditions. Eleven well-trained long-distance male runners performed four exercises of different duration and intensity. TL was evaluated using Foster and Banister methods. In addition, HRV measurements were performed 5 minutes before exercise and 5 and 30 minutes after exercise. We calculated HRV index (TLHRV) based on the ratio between HRV decrease during exercise and HRV increase during recovery. HRV decrease during exercise was strongly correlated with exercise intensity (R = -0.70; p < 0.01) but not with exercise duration or training volume. TLHRV index was correlated with Foster (R = 0.61; p = 0.01) and Banister (R = 0.57; p = 0.01) methods. This study confirms that HRV changes during exercise and recovery phase are affected by both intensity and physiological impact of the exercise. Since the TLHRV formula takes into account the disturbance and the return to homeostatic balance induced by exercise, this new method provides an objective and rational TL index. However, some simplification of the protocol measurement could be envisaged for field use.
Resumo:
In this work, we have studied the texturization process of (100) c-Si wafers using a low concentration potassium hydroxide solution in order to obtain good quality textured wafers. The optimization of the etching conditions have led to random but uniform pyramidal structures with good optical properties. Then, symmetric heterojunctions were deposited by Hot-Wire CVD onto these substrates and the Quasi-Steady-State PhotoConductance technique was used to measure passivation quality. Little degradation in the effective lifetime and implicit open circuit voltage of these devices (< 20 mV) was observed in all cases. It is especially remarkable that for big uniform pyramids, the open-circuit voltage is comparable to the values obtained on flat substrates.
Resumo:
Drug combinations can improve angiostatic cancer treatment efficacy and enable the reduction of side effects and drug resistance. Combining drugs is non-trivial due to the high number of possibilities. We applied a feedback system control (FSC) technique with a population-based stochastic search algorithm to navigate through the large parametric space of nine angiostatic drugs at four concentrations to identify optimal low-dose drug combinations. This implied an iterative approach of in vitro testing of endothelial cell viability and algorithm-based analysis. The optimal synergistic drug combination, containing erlotinib, BEZ-235 and RAPTA-C, was reached in a small number of iterations. Final drug combinations showed enhanced endothelial cell specificity and synergistically inhibited proliferation (p < 0.001), but not migration of endothelial cells, and forced enhanced numbers of endothelial cells to undergo apoptosis (p < 0.01). Successful translation of this drug combination was achieved in two preclinical in vivo tumor models. Tumor growth was inhibited synergistically and significantly (p < 0.05 and p < 0.01, respectively) using reduced drug doses as compared to optimal single-drug concentrations. At the applied conditions, single-drug monotherapies had no or negligible activity in these models. We suggest that FSC can be used for rapid identification of effective, reduced dose, multi-drug combinations for the treatment of cancer and other diseases.
Resumo:
S u b s u r face fluid flow plays a significant role in many geologic processes and is increasingly being studied in the scale of sedimentary basins and geologic time perspective. Many economic resources such as petroleum and mineral deposits are products of basin scale fluid flow operating over large periods of time. Such ancient flow systems can be studied through analysis of diagenetic alterations and fluid inclusions to constrain physical and chemical conditions of fluids and rocks during their paleohy d r og e o l ogic evolution. Basin simulation models are useful to complement the paleohy d r og e o l ogic record preserved in the rocks and to derive conceptual models on hydraulic basin evolution and generation of economic resources. Different types of fluid flow regimes may evo l ve during basin evolution. The most important with respect to flow rates and capacity for transport of solutes and thermal energy is gr avitational fluid flow driven by the topographic configuration of a basin. Such flow systems require the basin to be elevated above sea level. Consolidational fluid flow is the principal fluid migration process in basins below sea level, caused by loading of compressible rocks. Flow rates of such systems are several orders of magnitude below topogr a p hy driven flow. Howeve r, consolidation may create significant fluid ove rpressure. Episodic dewatering of ove rpressured compart m e n t s m ay cause sudden fluid release with elevated flow velocities and may cause a transient local thermal and chemical disequilibrium betwe e n fluid and rock. This paper gives an ove rv i ew on subsurface fluid flow processes at basin scale and presents examples related to the Pe n e d è s basin in the central Catalan continental margin including the offshore Barcelona half-graben and the compressive South-Pyrenean basin.
Resumo:
Imaging systems have developed latest years and developing is still continuing following years. Manufacturers of imaging systems give promises for the quality of the performance of imaging systems to advertise their products. Promises for the quality of the performance are often so good that they will not be tested in normal usage. The main target in this research is to evaluate the quality of the performance of two imaging systems: Scanner and CCD color camera. Optical measurement procedures were planned to evaluate the quality of imaging performances. Other target in this research is to evaluate calibration programs for the camera and the scanner. Measuring targets had to choose to evaluate the quality of imaging performances. Manufacturers have given definitions for targets. The third task in this research is to evaluate and consider how good measuring targets are.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.
Resumo:
Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.