867 resultados para Insulation (Heat)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heat recovery devices are important in the optimization of thermal systems, since they can be used to reduce thermal losses to the environment. The use of heat pipes in these types of equipment can provide heat recoveries of higher efficiency, since both fluid flows are external and there are less contamination risks between the hot and cold fluids. The objective of this work is to study a heat recovery unit constructed with heat pipes and mainly, to analyze the influence of the inclination of the heat pipes on the performance of the equipment. For this analysis, a heat recovery unit was constructed which possesses 48 finned heat pipes in triangular geometry, the evaporator and condenser being of the same length. This unit was tested in an air-air system simulating a heat recovery process in which heat was supplied to the hot fluid by electrical resistances. The results have shown that there exists an inclination at which the system has a better performance, but for higher inclinations there is no significant increase of the efficiency of the system. This paper also presents the influence of inclination of heat pipes on effectiveness and NTU parameters which are important in heat exchanger design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this paper is to present a generalized analytical-numerical model of the internal flow in heat pipes. The model formulation is based on two-dimensional formulation of the energy and momentum equations in the vapour and liquid regions and also in the metallic tube. The numerical solution of the model is obtained by using the descretization scheme LOAD and the SIMPLE numerical code. The flow fields, as well as the pressure fields, for different geometries were obtained and discussed. Copyright © 1996 Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The selection and use of hard chairside reline resins must be made with regard to dimensional stability, which will influence the accuracy of fit of the denture base. This study compared the dimensional change of two hard chairside reline resins (Duraliner II and Kooliner) and one heat-curing denture base resin (Lucitone 550). A stainless steel mold with reference dimensions (AB, CD) was used to obtain the samples. The materials were processed according to the manufacturer's recommendations. Measurements of the dimensions were made after processing and after the samples had been stored in distilled water at 37° C for eight different periods of time. The data were recorded and then analyzed with analysis of variance. All materials showed shrinkage immediately after processing (p < 0.05). The only resin that exhibited shrinkage after 60 days of storage in water was Duraliner II; these changes could be clinically significant in regard of tissue fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Four trials of identical experimental design were conducted to determine the effects of temperature, dietary Lys level, and dietary Arg:Lys ratios on performance and carcass yield of male broilers. Birds of a commercial strain were grown from 21 to 42 d of age in wire-floored finishing batteries placed in environmental chambers. The chambers were programmed to provide either a constant thermoneutral temperature (21.1 C), a constant cold temperature (15.5 C), or a cycling hot diurnal temperature (25.5 to 33.3 C). Within each environment there was a factorial arrangement of three Lys levels (1.0, 1.1, and 1.2%) with four Arg:Lys ratios (1.1:1, 1.2:1, 1.3:1, and 1.4:1). Environmental temperature significantly influenced virtually every characteristic examined. Hot cyclic temperatures reduced weight gain, feed intake, and breast meat yield, and increased feed conversion, dressing percentage, leg quarter yield, and abdominal fat content. The cold environment promoted increased feed intake and mortality. Ascites and cardiomyopathy were the leading causes of death under cold exposure and thermoneutral conditions, whereas complications arising from heat exposure were the main cause of death under hot cyclic conditions. Levels of Lys affected leg quarter yield and abdominal fat content over all environments but increased breast meat yield only under cold conditions. Increasing Arg: Lys ratios improved feed conversion and dressing percentage and reduced abdominal fat content; it could not be determined whether these responses were consistent with Arg per se or were due to a nonspecific N response. As increasing Lys levels or Arg:Lys ratios did not improve weight gain, increase breast meat yield, or attenuate adverse effects due to heat or cold exposure, it is concluded that the levels of Lys and Arg suggested for 21 to 42 d by the NRC are adequate for birds of this age under the environmental conditions encountered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigates some factors affecting the inactivation of common bean trypsin inhibitor and phytohemagglutin. Trypsin inhibitor activity was totally stable to heat treatment (30 min, 97C) in the total protein extract, albumin or globulin fraction. Heat treatment of the whole beans easily inactivated the inhibitor. Heat resistance of trypsin inhibitor was intermediate in the bean flour which received the same heat treatment. Independent of sample, the inhibitor was very stable to heat treatment at neutral and acidic pH and labile under strong alkaline conditions. Heating for 30 min in boiling water at pH 12 resulted in complete inactivation of the trypsin inhibitor. Autoclaving (121C) soaked whole beans and flour for 5 min inactivated 55% of the trypsin inhibitor activity in the soaked flour and 75% in the whole beans. After autoclaving 20 min, inactivation of trypsin inhibitor was about 65% in the flour and 80% in the whole beans. The phytohemagglutinin (lectin) activity was totally destroyed in the autoclaved beans after 5 min and in the flour after 15 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of a numerical and experimental study of phase change material (PCM) filled walls and roofs under real operational conditions to achieve passive thermal comfort. The numerical part of the study was based on a one-dimensional model for the phase change problem controlled by pure conduction. Real radiation data was used to determine the external face temperature. The numerical treatment was based upon using finite difference approximations and the ADI scheme. The results obtained were compared with field measurements. The experimental set-up consisted of a small room with movable roof and side wall. The roof was constructed in the traditional way but with the phase change material enclosed. Thermocouples were distributed across the cross section of the roof. Another roof, identical but without the PCM, was also used during comparative tests. The movable wall was also constructed as is done traditionally but with the PCM enclosed. Again, thermocouples were distributed across the wall thickness to enable measurement of the local temperatures. Another wall, identical but without the PCM, was also used during comparative tests. The PCM used in the numerical and experimental tests was composed of a mixture of two commercial grades of glycol in order to obtain the required fusion temperature range. Comparison between the simulation results and the experiments indicated good agreement. Field tests also indicated that the PCM used was adequate and that the concept was effective in maintaining the indoor temperature very close to the established comfort limits. Further economical analysis indicated that the concept could effectively help in reducing the electric energy consumption and improving the energy demand pattern. © 1997 by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work considers a problem of interest in several technological applications such as the thermal control of electronic equipment. It is also important to study the heat transfer performance of these components under off-normal conditions, such as during failure of cooling fans. The effect of natural convection on the flow and heat transfer in a cavity with two flush mounted heat sources on the left vertical wall, simulating electronic components, is studied numerically and experimentally. The influence of the power distribution, spacing between the heat sources and cavity aspect ratio have been investigated. An analysis of the average Nusselt number of the two heat sources was performed to investigate the behavior of the heat transfer coefficients. The results obtained numerically and experimentally, after an error analysis, showed a good agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Because water sorption of autopolymerizing acrylic reline resins is accompanied by volumetric change, it is a physical property of importance. As residual monomer leaches into the oral fluids and causes tissue irritation, low solubility of these resins is desired. Another requirement is a satisfactory bond between the autopolymerizing acrylic resins and the denture base acrylic resin. PURPOSE: This study compared the water sorption, solubility, and the transverse bond strength of 2 autopolymerizing acrylic resins (Duraliner II and Kooliner) and 1 heat-polymerizing acrylic resin (Lucitone 550). MATERIAL AND METHODS: The water sorption and solubility test was performed as per International Standards Organization Specification No. 1567 for denture base polymers. Bond strengths between the autopolymerizing acrylic resins and the heat-polymerizing acrylic resin were determine with a 3-point loading test made on specimens immersed in distilled water at 37 degrees C for 50 hours and for 30 days. Visual inspection determined whether failures were adhesive or cohesive. RESULTS: Duraliner II acrylic resin showed significantly lower water sorption than Kooliner and Lucitone 550 acrylic resins. No difference was noted in the solubility of all materials. Kooliner acrylic resin demonstrated significantly lower transverse bond strength to denture base acrylic resin and failed adhesively. The failures seen with Duraliner II acrylic resin were primarily cohesive in nature. CONCLUSIONS: Autopolymerizing acrylic reline resins met water sorption and solubility requirements. However, Kooliner acrylic resin demonstrated significantly lower bond strength to denture base acrylic resin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of heat-treatment temperature on LiNbO3 thin films prepared by the polymeric precursor method were investigated. The precursor solution was deposited on Si(111) substrates by dip coating. X-ray diffraction and thermal analyses revealed that the crystallization process occurred at a low temperature (420 °C) and led to films with no preferential orientation. High-temperature treatments promoted formation of the LiNb3O8 phase. Scanning electron microscopy, coupled with energy dispersive spectroscopy analyses, showed that the treatment temperature also affected the film microstructure. The surface texture - homogeneous, smooth, and pore-free at low temperature - turned into an `islandlike' microstructure for high-temperature treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the effect of heat and moisture exchange (HME) on the tracheobronchial tree (TBT) using a unidirectional anesthesic circuit with or without CO2 absorber and high or low fresh gas flow (FGF), in dogs. Methods: Thirty-two dogs were randomly allocated to four groups: G1 (n = 8) valvular circuit without CO2 absorber and high FGF (5 L·min-1); G2 (n = 8) as G1 with HME; G3 (n = 8) circuit with CO2 absorber with a low FGF (1 L·min-1); G4 (n = 8) as G3 with HME. Anesthesia was induced and maintained with pentobarbital. Tympanic temperature (TT), inhaled gas temperature (IGT), relative (RH) and absolute humidity (AH) of inhaled gas were measured at 15 (control), 60, 120 and 180 min of controlled ventilation. Dogs were euthanized and biopsies in the areas of TBT were performed by scanning electron microscopy. Results: The G2 and G4 groups showed the highest AH (>20 mgH2O·L-1) and G1 the lowest (< 10 mgH2O·L-1) and G3 was intermediate (<20 mgH2O·L-1) (P < 0.01). There was no difference of TT and IGT among groups. Alterations of the mucociliary system were greatest in G1, least in G2 and G4, and intermediate in G3. Conclusion: In dogs, introduction of HME to a unidirectional anesthetic circuit with/without CO2 absorber and high or low FGF preserved humidity of inspired gases. HME attenuated but did not prevent alterations of the mucociliary system of the TBT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we present two-phase flow nonlinear parameter estimation for HFC's flow through capillary tube-suction line heat exchangers, commonly used as expansion devices in small refrigeration systems. The simplifying assumptions adopted are: steady state, pure refrigerant, one-dimensional flow, negligible axial heat conduction in the fluid, capillary tube and suction line walls. Additionally, it is considered that the refrigerant is free from oil and both phases are assumed to be at the same pressure, that is, surface tension effects are neglected. Metastable flow effects are also disregarded, and the vapor is assumed to be saturated at the local pressure. The so-called homogeneous model, involving three, first order, ordinary differential equations is applied to analyze the two-phase flow region. Comparison is done with experimental measurements of the mass flow rate and temperature distribution along capillary tubes working with refrigerant HFC-134a in different operating conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Little data are available regarding the effect of heat-treatments on the dimensional stability of hard chairside reline resins. Purpose. The objective of this in vitro study was to evaluate whether a heat-treatment improves the dimensional stability of the reline resin Duraliner II and to compare the linear dimensional changes of this material with the heat-polymerized acrylic resin Lucitone 550. Material and methods. The materials were mixed according to the manufacturer's instructions and packed into a stainless steel split mold (50.0 mm diameter and 0.5 mm thickness) with reference points (A, B, C, and D). Duraliner II specimens were polymerized for 12 minutes in water at 37°C and bench cooled to room temperature before being removed from the mold. Twelve specimens were made and divided into 2 groups: group 1 specimens (n=6) were left untreated, and group 2 specimens (n=6) were submitted to a heat-treatment in a water bath at 55°C for 10 minutes and then bench cooled to room temperature. The 6 Lucitone specimens (control group) were polymerized in a water bath for 9 hours at 71°C. The specimens were removed after the mold reached the room temperature. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold (baseline readings) and on the specimens to the nearest 0.001 mm. Measurements were made after processing and after the specimens had been stored in distilled water at 37°C for 8 different periods of time. Data were subjected to analysis of variance with repeated measures, followed by Tukey's multiple comparison test (P<.05). Results. All specimens exhibited shrinkage after processing (control, -0.41%; group 1, -0.26%; and group 2, -0.51%). Group 1 specimens showed greater shrinkage (-1.23%) than the control (-0.23%) and group 2 (-0.81%) specimens after 60 days of storage in water (P<.05). Conclusion. Within the limitations of this study, a significant improvement of the long-term dimensional stability of the Duraliner II reline resin was observed when the specimens were heat-treated. However, the shrinkage remained considerably higher than the denture base resin Lucitone 550. Copyright © 2002 by The Editorial Council of The Journal of Prosthetic Dentistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ross male broiler chicks (n = 480) on new litter were used in a randomized block design with two blocks (environmental rooms) and four treatments having four replicate pens (1.0 × 2.5 m; 15 chicks) each to evaluate dietary electrolyte balance (DEB; P < 0.05). Two rooms were 1) thermoneutral (Weeks 1 through 6, with decreasing maximum from 32 to 25°C and minimum from 28 to 19°C; relative humidity 49 to 58%) and 2) cyclic daily heat stress (Weeks 1 and 2, thermoneutral; Weeks 2 through 6, maximum temperatures 35, 35, 33, and 33°C, respectively; and minimum temperatures 23, 20, 19, and 19°C, respectively; relative humidity 51 to 54%). The DEB treatments (0, 140, 240, or 340 mEq Na + K - Cl/kg) had NaHCO3 plus NH4Cl, or KHCO3, or both added to corn-soybean meal mash basal diets with 0.30% salt (NaCl). In the thermoneutral room, DEB 240 increased 42-d weight gain and 44-d lymphocyte percentage and decreased heterophil percentage and heterophil to lymphocyte ratio compared to the DEB 40 treatment. The DEB 240 diets had 0.35 and 0.35% Na and 0.37% and 0.29% Cl in starter (0.75% K) and grower (0.67% K) diets, respectively. No DEB treatment differences were found in the heat stress room. For combined rooms, 42-d feed intake was higher for DEB 240 than for DEB 40. The 21-d weight gain was higher for DEB 240 than for DEB 40 or 140; and 21-d feed/gain was lower for DEB 40 than for DEB 340. The predicted maximum point of inflection for 21- and 42-d weight gains were DEB 250 and 201, with highest 42-d feed intake at 220.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study compared the effect of two postpolymerization heat treatments on the cytotoxicity of three denture base resins on L929 cells using 3H-thymidine incorporation and MTT assays. Materials and Methods: Sample disks of Lucitone 550, QC 20, and Acron MC resins were fabricated under aseptic conditions and stored in distilled water at 37°C for 48 hours. Specimens were then divided into three groups: (1) heat treated in microwave oven for 3 minutes at 500 W; (2) heat treated in water bath at 55°C for 60 minutes; and (3) no heat treatment. Eluates were prepared by placing three disks into a sterile glass vial with 9 mL of Eagle's medium and incubating at 37°C for 24 hours. The cytotoxic effect from the eluates was evaluated using the 3H-thymidine incorporation and MTT assays, which reflect DNA synthesis levels and cell metabolism, respectively. Results: The components leached from the resins were cytotoxic to L929 cells when 3H- thymidine incorporation assay was employed. In contrast, eluates from all resins revealed noncytotoxic effects as measured by MTT assay. For both MTT assay and 3H-thymidine incorporation, the heat treatments did not decrease the cytotoxicity of the materials tested. Conclusion: Resins were graded by 3H-thymidine incorporation assay as slightly cytotoxic and by MTT assay as noncytotoxic. Cytotoxicity of the denture base materials was not influenced by microwave or water bath heat treatment.