952 resultados para Imaging, three-dimensional
Resumo:
PURPOSE: To prospectively evaluate the accuracy and reliability of "freehand" posttraumatic orbital wall reconstruction with AO (Arbeitsgemeinschaft Osteosynthese) titanium mesh plates by using computer-aided volumetric measurement of the bony orbits. METHODS: Bony orbital volume was measured in 12 patients from coronal CT scan slices using OsiriX Medical Image software. After defining the volumetric limits of the orbit, the segmentation of the bony orbital region of interest of each single slice was performed. At the end of the segmentation process, all regions of interest were grouped and the volume was computed. The same procedure was performed on both orbits, and thereafter the volume of the contralateral uninjured orbit was used as a control for comparison. RESULTS: In all patients, the volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 1.85 cm3 (7%). CONCLUSIONS: This preliminary study has demonstrated that posttraumatic orbital wall reconstruction using "freehand" bending and placement of AO titanium mesh plates results in a high success rate in re-establishing preoperative bony volume, which closely approximates that of the contralateral uninjured orbit.
Resumo:
OBJECT: In 1999 we reported that 94% of unruptured middle cerebral artery (MCA) aneurysms managed prospectively between 1993 and 1997, according to a protocol favoring endovascular coiling, were best treated by surgical clipping. The goal of the current study was to delineate the most appropriate treatment option for unruptured MCA aneurysms today, considering the technical advances in imaging and in endovascular treatment. METHODS: 35 consecutive patients harboring 40 unruptured MCA aneurysms were treated between 1997 and December 2000. Patients with unruptured cerebral aneurysms are managed prospectively according to the same protocol as reported previously [1]: the primary treatment recommendation is endovascular packing with Guglielmi detachable coils (GDCs). Surgical clipping is recommended after failed attempt at coil placement or in the presence of angioanatomical features that contraindicate that type of endovascular therapy. RESULTS: One unruptured MCA aneurysm was treated by endovascular embolization, 37 unruptured MCA aneurysms were clipped, whereas 2 unruptured MCA aneurysms were trapped with simultaneous extracranial-intracranial revascularization. Postoperative angiography revealed complete exclusion of all aneurysms. Preservation of vascular permeability was demonstrated in all clip-reconstructed aneurysms, despite arterial branches frequently originating from the aneurysmal base. Cerebral revascularization of the distal MCA was successful in the 2 patients with giant aneurysms. None of the patients presented permanent disabling complications from the treatment of the unruptured MCA aneurysm. CONCLUSION: Despite major technical advances in imaging and in endovascular treatment of cerebral aneurysms, surgical clipping still is the most efficient treatment for unruptured MCA aneurysms at the beginning of the new millennium.
Resumo:
BACKGROUND: Accurate assessment of glenoid inclination is of interest for a variety of conditions and procedures. The purpose of this study was to develop an accurate and reproducible measurement for glenoid inclination on standardized anterior-posterior (AP) radiographs and on computed tomography (CT) images. MATERIALS AND METHODS: Three consistently identifiable angles were defined: Angle α by line AB connecting the superior and inferior glenoid tubercle (glenoid fossa) and the line identifying the scapular spine; angle β by line AB and the floor of the supraspinatus fossa; angle γ by line AB and the lateral margin of the scapula. Experimental study: these 3 angles were measured in function of the scapular position to test their resistance to rotation. Conventional AP radiographs and CT scans were acquired in extension/flexion and internal/external rotation in a range up to ±40°. Clinical study: the inter-rater reliability of all angles was assessed on AP radiographs and CT scans of 60 patients (30 with proximal humeral fractures, 30 with osteoarthritis) by 2 independent observers. RESULTS: The experimental study showed that angle α and β have a resistance to rotation of up to ±20°. The deviation from neutral position was not more than ±10°. The results for the inter-rater reliability analyzed by Bland-Altman plots for the angle β fracture group were (mean ± standard deviation) -0.1 ± 4.2 for radiographs and -0.3 ± 3.3 for CT scans; and for the osteoarthritis group were -1.2 ± 3.8 for radiographs and -3.0 ± 3.6 for CT scans. CONCLUSION: Angle β is the most reproducible measurement for glenoid inclination on conventional AP radiographs, providing a resistance to positional variability of the scapula and a good inter-rater reliability.
Resumo:
In order to compare coronary magnetic resonance angiography (MRA) data obtained with different scanning methodologies, adequate visualization and presentation of the coronary MRA data need to be ensured. Furthermore, an objective quantitative comparison between images acquired with different scanning methods is desirable. To address this need, a software tool ("Soap-Bubble") that facilitates visualization and quantitative comparison of 3D volume targeted coronary MRA data was developed. In the present implementation, the user interactively specifies a curved subvolume (enclosed in the 3D coronary MRA data set) that closely encompasses the coronary arterial segments. With a 3D Delaunay triangulation and a parallel projection, this enables the simultaneous display of multiple coronary segments in one 2D representation. For objective quantitative analysis, frequently explored quantitative parameters such as signal-to-noise ratio (SNR); contrast-to-noise ratio (CNR); and vessel length, sharpness, and diameter can be assessed. The present tool supports visualization and objective, quantitative comparisons of coronary MRA data obtained with different scanning methods. The first results obtained in healthy adults and in patients with coronary artery disease are presented.
Resumo:
PURPOSE: Signal detection on 3D medical images depends on many factors, such as foveal and peripheral vision, the type of signal, and background complexity, and the speed at which the frames are displayed. In this paper, the authors focus on the speed with which radiologists and naïve observers search through medical images. Prior to the study, the authors asked the radiologists to estimate the speed at which they scrolled through CT sets. They gave a subjective estimate of 5 frames per second (fps). The aim of this paper is to measure and analyze the speed with which humans scroll through image stacks, showing a method to visually display the behavior of observers as the search is made as well as measuring the accuracy of the decisions. This information will be useful in the development of model observers, mathematical algorithms that can be used to evaluate diagnostic imaging systems. METHODS: The authors performed a series of 3D 4-alternative forced-choice lung nodule detection tasks on volumetric stacks of chest CT images iteratively reconstructed in lung algorithm. The strategy used by three radiologists and three naïve observers was assessed using an eye-tracker in order to establish where their gaze was fixed during the experiment and to verify that when a decision was made, a correct answer was not due only to chance. In a first set of experiments, the observers were restricted to read the images at three fixed speeds of image scrolling and were allowed to see each alternative once. In the second set of experiments, the subjects were allowed to scroll through the image stacks at will with no time or gaze limits. In both static-speed and free-scrolling conditions, the four image stacks were displayed simultaneously. All trials were shown at two different image contrasts. RESULTS: The authors were able to determine a histogram of scrolling speeds in frames per second. The scrolling speed of the naïve observers and the radiologists at the moment the signal was detected was measured at 25-30 fps. For the task chosen, the performance of the observers was not affected by the contrast or experience of the observer. However, the naïve observers exhibited a different pattern of scrolling than the radiologists, which included a tendency toward higher number of direction changes and number of slices viewed. CONCLUSIONS: The authors have determined a distribution of speeds for volumetric detection tasks. The speed at detection was higher than that subjectively estimated by the radiologists before the experiment. The speed information that was measured will be useful in the development of 3D model observers, especially anthropomorphic model observers which try to mimic human behavior.
Resumo:
BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.
Resumo:
In a classic model of mammalian brain formation, precursors of principal glutamatergic neurons migrate radially along radial glia fibers whereas GABAergic interneuron precursors migrate tangentially. These migration modes have significant implications for brain function. Here we used clonal lineage tracing of active radial glia-like neural stem cells in the adult mouse dentate gyrus and made the surprising discovery that proliferating neuronal precursors of glutamatergic granule neurons exhibit significant tangential migration along blood vessels, followed by limited radial migration. Genetic birthdating and morphological and molecular analyses pinpointed the neuroblast stage as the main developmental window when tangential migration occurs. We also developed a partial "whole-mount" dentate gyrus preparation and observed a dense plexus of capillaries, with which only neuroblasts, among the entire population of progenitors, are directly associated. Together, these results provide insight into neuronal migration in the adult mammalian nervous system.
Resumo:
The authors thoroughly report the development, the technical aspects and the performance of the first navigated liver resections, by laparotomy and laparoscopy, in Brazil, done at the National Cancer Institute, Ministry of Health, using a surgical navigator.
Resumo:
This paper provides an overview of work done in recent years by our research group to fuse multimodal images of the trunk of patients with Adolescent Idiopathic Scoliosis (AIS) treated at Sainte-Justine University Hospital Center (CHU). We first describe our surface acquisition system and introduce a set of clinical measurements (indices) based on the trunk's external shape, to quantify its degree of asymmetry. We then describe our 3D reconstruction system of the spine and rib cage from biplanar radiographs and present our methodology for multimodal fusion of MRI, X-ray and external surface images of the trunk We finally present a physical model of the human trunk including bone and soft tissue for the simulation of the surgical outcome on the external trunk shape in AIS.
Resumo:
STUDY DESIGN: Concurrent validity between postural indices obtained from digital photographs (two-dimensional [2D]), surface topography imaging (three-dimensional [3D]), and radiographs. OBJECTIVE: To assess the validity of a quantitative clinical postural assessment tool of the trunk based on photographs (2D) as compared to a surface topography system (3D) as well as indices calculated from radiographs. SUMMARY OF BACKGROUND DATA: To monitor progression of scoliosis or change in posture over time in young persons with idiopathic scoliosis (IS), noninvasive and nonionizing methods are recommended. In a clinical setting, posture can be quite easily assessed by calculating key postural indices from photographs. METHODS: Quantitative postural indices of 70 subjects aged 10 to 20 years old with IS (Cobb angle, 15 degrees -60 degrees) were measured from photographs and from 3D trunk surface images taken in the standing position. Shoulder, scapula, trunk list, pelvis, scoliosis, and waist angles indices were calculated with specially designed software. Frontal and sagittal Cobb angles and trunk list were also calculated on radiographs. The Pearson correlation coefficients (r) was used to estimate concurrent validity of the 2D clinical postural tool of the trunk with indices extracted from the 3D system and with those obtained from radiographs. RESULTS: The correlation between 2D and 3D indices was good to excellent for shoulder, pelvis, trunk list, and thoracic scoliosis (0.81>r<0.97; P<0.01) but fair to moderate for thoracic kyphosis, lumbar lordosis, and thoracolumbar or lumbar scoliosis (0.30>r<0.56; P<0.05). The correlation between 2D and radiograph spinal indices was fair to good (-0.33 to -0.80 with Cobb angles and 0.76 for trunk list; P<0.05). CONCLUSION: This tool will facilitate clinical practice by monitoring trunk posture among persons with IS. Further, it may contribute to a reduction in the use of radiographs to monitor scoliosis progression.
Resumo:
The purpose of this study was to investigate the effects of cigarette smoke on the development of the embryo mandible (Meckel's) cartilage in rat fetuses. When inhaled by female Wistar rats between the 9th and the 12th day of pregnancy, cigarette smoke (5 cigarettes a day) caused intrauterine growth retardation, providing smaller fetuses and placentas. In fetuses from the experimental group, the histopathologic examination revealed a poorly developed Meckel' s cartilage with smaller chondroblasts showing a scanty cytoplasm with spherical and paler central nuclei, as well as more abundant cartilage matrix. Morphometric analysis revealed that Meckel's cartilage lacunae were smaller in the fetuses from the experimental group, although not showing any remarkable alteration in shape. The results suggested that inhalation of cigarette smoke by pregnant rats during the organogenic period induced growth retardation and delayed cellular differentiation in rat fetal Meckel's cartilage.
Resumo:
This article introduces a new method for 3-dimensional dental cast analysis, by using a mechanical 3-dimensional digitizer, MicroScribe 3DX (Immersion, San Jose, Calif), and TIGARO software (not yet released, but available from the author at hayasaki@dent.kyushu-u.ac.jp). By digitizing points on the model, multiple measurements can be made, including tooth dimensions; arch length, width, and perimeter; curve of Spee; overjet and overbite; and anteroposterior discrepancy. The bias of the system can be evaluated by comparing the distance between 2 points as determined by the new system and as measured with digital calipers. Fifteen pairs of models were measured digitally and manually, and the bias was evaluated by comparing the variances of both methods and checking for the type of error obtained by each method. No systematic errors were found. The results showed that the method is accurate, and it can be applied to both clinical practice and research. Copyright © 2005 by the American Association of Orthodontists.
Resumo:
The aim of this prospective study was to evalute the midpalatal suture in children submitted to rapid palatal expansion, at the end of the retention stage, with CT scans. The sample was comprised of 17 children aged between 5 years 2 months and 10 years 5 months. The tomographic images showed that the midpalatal suture was completely ossified from the anterior nasal spine area to the posterior nasal spine area at the end of the retention phase, that is, 8 to 9 months post-expansion.
Resumo:
Introduction: Impacted knife injuries in the maxillofacial region are rare and infrequently reported. In cases of injury involving orbit or eye, these reports are even rarer. Discussion: Damage to the orbital contents may result in a rupture of the globe, extraocular muscle injury, lacrimal gland damage, and others. Orbital foreign bodies are not only difficult to detect, and clinical features vary according to its size, characteristics, shape, penetrating method, and site. In this report, a case of abducens nerve palsy after orbitoethmoidal knife injury is presented. © 2010 Springer-Verlag.