981 resultados para FORMING SYSTEM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Late Miocene Malbusca outcrop is located in the southeastern coast of Santa Maria Island (Azores, NE Atlantic), interspersed in volcanic formations. At ~20 meters above present sea level, a prominent discontinuous layer of rhodoliths seizes with an extension of ~250 meters. This paper presents the first taxonomic record of fossil rhodolith forming coralline algae for the Miocene of the Azores. The preserved taxonomic features used were the following: (1) arrangement of basal filaments, (2) epithallial cells (when observable), (3) presence of cell fusions, (4) conceptacle type, (5) number of cells layers which conceptacle chamber floors are situated below the surrounding thallus surface and (6) for the sporangial pores, the orientation of the filaments around the conceptacle pores. Based on these characters, six taxa were identified encompassing three Corallinaceae (Lithophyllum prototypum, Lithophyllum sp., Spongites sp., Hydrolithon sp.) and one Hapalidaceae (Phymatolithon calcareum and cf. Phymatolithon sp.). An unidentified coaxial thallus was also present, the coaxial construction ascribing the specimens to the genus Mesophyllum or Neogoniolithon. Taxonomic accounts for the identified taxa are described, illustrated and an identification key is provided. The report of L prototypum represents the first Miocene record and the preservation of the specimens is very good. Miocene coralline algae seem very consistent among deposits but some species are relevant for particular areas, like in the Azores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis submitted in the fulfilment of the requirements for the Degree of Master in Electronic and Telecomunications Engineering

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On this work we suggest a teaching solution that can be implemented in Azores, an archipelago of nine islands of Portugal, based in already known system of e-learning, with a twist based on the flipped method. Structured in a cooperative way, the organization of the system allows to isolated groups of people to have access to a certain level of teaching, if they cannot have the possibility to have physical presence in school due to problems emerging from territory discontinuity. Our suggestion can be elaborate in a model that can be adapted to any level of education, and can be adapted also in cases that a cut of budget exists. We suggest the name of fb-learning: Flipped Broadcast Learning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Desde o início que os sistemas periciais não foram vistos apenas como sistemas que poderiam substituir os peritos. Os peritos por sua vez, independentemente da área em que operam, eram tidos como indivíduos que atingiram a excelência através da experiência, estudo e total dedicação, por vezes durante anos. Hoje, mais do que assumir o papel de um perito na excelência de uma área de actuação, os sistemas periciais sobressaem pela disponibilidade contínua, acessos facilitados, custos reduzidos, estabilidade de funcionamento e coerência de raciocínio. Empurrados pelos avanços actuais das redes em termos de velocidade e propagação global, estes sistemas são hoje disponibilizados de forma mais simples e acessível. Este trabalho é realizado com o propósito de evoluir o actual sistema para uma versão mais apelativa, funcional e fiável. Um dos objectivos passa pela evolução do actual modo de funcionamento, utilização local e apenas um utilizador, para um modo de funcionamento que permita uma disponibilização num ambiente de acesso global, acessível a qualquer hora e em qualquer local.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os serviços baseados em localização vieram dar um novo alento à criatividade dos programadores de aplicações móveis. A vulgarização de dispositivos com capacidades de localização integradas deu origem ao desenvolvimento de aplicações que gerem e apresentam informação baseada na posição do utilizador. Desde então, o mercado móvel tem assistido ao aparecimento de novas categorias de aplicações que tiram proveito desta capacidade. Entre elas, destaca-se a monitorização remota de dispositivos, que tem vindo a assumir uma importância crescente, tanto no sector particular como no sector empresarial. Esta dissertação começa por apresentar o estado da arte sobre os diferentes sistemas de posicionamento, categorizados pela sua eficácia em ambientes internos ou externos, assim como diferentes protocolos de comunicação em tempo quase-real. É também feita uma análise ao estado actual do mercado móvel. Actualmente o mercado possui diferentes plataformas móveis com características únicas que as fazem rivalizar entre si, com vista a expandirem a sua quota de mercado. É por isso elaborado um breve estudo sobre os sistemas operativos móveis mais relevantes da actualidade. É igualmente feita uma abordagem mais profunda à arquitectura da plataforma móvel da Apple - o iOS – que serviu de base ao desenvolvimento de uma solução optimizada para localização e monitorização de dispositivos móveis. A monitorização implica uma utilização intensiva de recursos energéticos e de largura de banda que os dispositivos móveis da actualidade não estão aptos a suportar. Dado o grande consumo energético do GPS face à precária autonomia destes dispositivos, é apresentado um estudo em que se expõem soluções que permitem gerir de forma optimizada a utilização do GPS. O elevado custo dos planos de dados facultados pelas operadoras móveis é também considerado, pelo que são exploradas soluções que visam minimizar a utilização de largura de banda. Deste trabalho, nasce a aplicação EyeGotcha, que para além de permitir localizar outros utilizadores de dispositivos móveis de forma optimizada, permite também monitorizar as suas acções baseando-se num conjunto de regras pré-definidas. Estas acções são reportadas às entidades monitoras, de modo automatizado e sob a forma de alertas. Visionando-se a comercialização da aplicação, é portanto apresentado um modelo de negócio que permite obter receitas capazes de cobrirem os custos de manutenção de serviços, aos quais o funcionamento da aplicação móvel está subjugado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O desenvolvimento de sistemas de localização pedestre com recurso a técnicas de dead reckoning tem mostrado ser uma área em expansão no mundo académico e não só. Existem algumas soluções criadas, no entanto, nem todas as soluções serão facilmente implementadas no mercado, quer seja pelo hardware caro, ou pelo sistema em si, que é desenvolvido tendo em conta um cenário em particular. INPERLYS é um sistema que visa apresentar uma solução de localização pedestre, independentemente do cenário, utilizando recursos que poderão ser facilmente usados. Trata-se de um sistema que utiliza uma técnica de dead reckonig para dar a localização do utilizador. Em cenários outdoor, um receptor GPS fornece a posição do utilizador, fornecendo uma posição absoluta ao sistema. Quando não é possível utilizar o GPS, recorre-se a um sensor MEMS e a uma bússola para se obter posições relativas à última posição válida do GPS. Para interligar todos os sensores foi utilizado o protocolo de comunicações sem fios ZigBee™. A escolha recaiu neste protocolo devido a factores como os seus baixos consumos e o seu baixo custo. Assim o sistema torna-se de uso fácil e confortável para o utilizador, ao contrário de sistemas similares desenvolvidos, que utilizam cabos para interligarem os diferentes componentes do sistema. O sensor MEMS do tipo acelerómetro tem a função de ler a aceleração horizontal, ao nível do pé. Esta aceleração será usada por um algoritmo de reconhecimento do padrão das acelerações para se detectar os passos dados. Após a detecção do passo, a aceleração máxima registada nesse passo é fornecida ao coordenador, para se obter o deslocamento efectuado. Foram efectuados alguns testes para se perceber a eficiência do INPERLYS. Os testes decorreram num percurso plano, efectuados a uma velocidade normal e com passadas normais. Verificou-se que, neste momento, o desempenho do sistema poderá ser melhorado, quer seja a nível de gestão das comunicações, quer a nível do reconhecimento do padrão da aceleração horizontal, essencial para se detectar os passos. No entanto o sistema é capaz de fornecer a posição através do GPS, quando é possível a sua utilização, e é capaz de fornecer a orientação do movimento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comunication in Internationa Conference with Peer Review First International Congress on Cardiovasular Technologies - CARDIOTECHNIX, Vilamoura, Portugal, 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a FIA system for the determination of total choline content in several types of milk is described. The samples were submitted to hydrochloric acid digestion before injection into the system and passed through an enzymatic reactor containing choline oxidase immobilised on glass beads. This enzymatic reaction releases hydrogen peroxide which then reacts with a solution of iodide. The decrease in the concentration of iodide ion is quantified using an iodide ion selective tubular electrode based on a homogeneous crystalline membrane. Validation of the results obtained with this system was performed by comparison with results from a method described in the literature and applied to the determination of total choline in milks. The relative deviation was always < 5%. The repeatability of the method developed was assessed by calculation of the relative standard deviation (RSD) for 12 consecutive injections of one sample. The RSD obtained was < 0.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The premise of this paper is that a model for communicating the national value system must start from a strategy aimed at the identification, the cultivation and communication of values that give consistency to the value system. The analysis concentrates on the elements of such strategies and on the implications of applying a value communication program on the identity architecture of the community. The paper will also discuss the role of the national value system in the context of the emerging global culture, where the individual has the power to create his/her own hybrid cultural model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agências financiadoras: FCT - PEstOE/FIS/UI0618/2011; PTDC/FIS/098254/2008 ERC-PATCHYCOLLOIDS e MIUR-PRIN

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the basis of its electrochemical behaviour a new flow-injection analysis (FIA) method with amperometric detection has been developed for quantification of the herbicide bentazone (BTZ) in estuarine waters. Standard solutions and samples (200 µL) were injected into a water carrier stream and both pH and ionic strength were automatically adjusted inside the manifold. Optimization of critical FIA conditions indicated that the best analytical results were obtained at an oxidation potential of 1.10 V, pH 4.5, and an overall flow-rate of 2.4 mL min–1. Analysis of real samples was performed by means of calibration curves over the concentration range 2.5x10–6 to 5.0x10–5 mol L–1, and results were compared with those obtained by use of an independent method (HPLC). The accuracy of the amperometric determinations was ascertained; errors relative to the comparison method were below 4% and sampling rates were approximately 100 samples h–1. The repeatability of the proposed method was calculated by assessing the relative standard deviation (%) of ten consecutive determinations of one sample; the value obtained was 2.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented describes the development and evaluation of two flow-injection analysis (FIA) systems for the automated determination of carbaryl in spiked natural waters and commercial formulations. Samples are injected directly into the system where they are subjected to alkaline hydrolysis thus forming 1-naphthol. This product is readily oxidised at a glassy carbon electrode. The electrochemical behaviour of 1-naphthol allows the development of an FIA system with an amperometric detector in which 1-naphthol determination, and thus measurement of carbaryl concentration, can be performed. Linear response over the range 1.0×10–7 to 1.0×10–5 mol L–1, with a sampling rate of 80 samples h–1, was recorded. The detection limit was 1.0×10–8 mol L–1. Another FIA manifold was constructed but this used a colorimetric detector. The methodology was based on the coupling of 1-naphthol with phenylhydrazine hydrochloride to produce a red complex which has maximum absorbance at 495 nm. The response was linear from 1.0×10–5 to 1.5×10–3 mol L–1 with a detection limit of 1.0×10–6 mol L–1. Sample-throughput was about 60 samples h–1. Validation of the results provided by the two FIA methodologies was performed by comparing them with results from a standard HPLC–UV technique. The relative deviation was <5%. Recovery trials were also carried out and the values obtained ranged from 97.0 to 102.0% for both methods. The repeatability (RSD, %) of 12 consecutive injections of one sample was 0.8% and 1.6% for the amperometric and colorimetric systems, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of this research is to exploit the possibility of using an ex situ solvent extraction technique for the remediation of soils contaminated with semi-volatile petroleum hydrocarbons. The composition of the organic phase was chosen in order to form a single phase mixture with an aqueous phase and simultaneously not being disturbed (forming stable emulsions) by the soil particles hauling the contaminants. It should also permit a regeneration of the organic solvent phase. As first, we studied the miscibility domain of the chosen ternary systems constituted by ethyl acetate–acetone–water. This system proved to satisfy the previous requirements allowing for the formation of a single liquid phase mixture within a large spectrum of compositions, and also allowing for an intimate contact with the soil. Contaminants in the diesel range within different functional groups were selected: xylene, naphthalene and hexadecane. The analytical control was done by gas chromatography with FID detector. The kinetics of the extractions proved to be fast, leading to equilibrium after 10 min. The effect of the solid–liquid ratio on the extraction efficiency was studied. Lower S/L ratios (1:8, w/v) proved to be more efficient, reaching recoveries in the order of 95%. The option of extraction in multiple contacts did not improve the recovery in relation to a single contact. The solvent can be regenerated by distillation with a loss around 10%. The contaminants are not evaporated and they remain in the non-volatile phase. The global results show that the ex situ solvent extraction is technically a feasible option for the remediation of semi-volatile aromatic, polyaromatic and linear hydrocarbons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical behaviour of the pesticide metam (MT) at a glassy carbon working electrode (GCE) and at a hanging mercury drop electrode (HMDE) was investigated. Different voltammetric techniques, including cyclic voltammetry (CV) and square wave voltammetry (SWV), were used. An anodic peak (independent of pH) at +1.46 V vs AgCl/Ag was observed in MTaqueous solution using the GCE. SWV calibration curves were plotted under optimized conditions (pH 2.5 and frequency 50 Hz), which showed a linear response for 17–29 mg L−1. Electrochemical reduction was also explored, using the HMDE. A well defined cathodic peak was recorded at −0.72 V vs AgCl/ Ag, dependent on pH. After optimizing the operating conditions (pH 10.1, frequency 150 Hz, potential deposition −0.20 V for 10 s), calibration curves was measured in the concentration range 2.5×10−1 to 1.0 mg L−1 using SWV. The electrochemical behaviour of this compound facilitated the development of a flow injection analysis (FIA) system with amperometric detection for the quantification of MT in commercial formulations and spiked water samples. An assessment of the optimal FIA conditions indicated that the best analytical results were obtained at a potential of +1.30 V, an injection volume of 207 μL and an overall flow rate of 2.4 ml min−1. Real samples were analysed via calibration curves over the concentration range 1.3×10−2 to 1.3 mg L−1. Recoveries from the real samples (spiked waters and commercial formulations) were between 97.4 and 105.5%. The precision of the proposed method was evaluated by assessing the relative standard deviation (RSD %) of ten consecutive determinations of one sample (1.0 mg L−1), and the value obtained was 1.5%.