878 resultados para FIRE RETARDANCY
Resumo:
Calcium ions are an important second messenger in living cells. Indeed calcium signals in the form of waves have been the subject of much recent experimental interest. It is now well established that these waves are composed of elementary stochastic release events (calcium puffs or sparks) from spatially localised calcium stores. The aim of this paper is to analyse how the stochastic nature of individual receptors within these stores combines to create stochastic behaviour on long timescales that may ultimately lead to waves of activity in a spatially extended cell model. Techniques from asymptotic analysis and stochastic phase-plane analysis are used to show that a large cluster of receptor channels leads to a release probability with a sigmoidal dependence on calcium density. This release probability is incorporated into a computationally inexpensive model of calcium release based upon a stochastic generalization of the Fire-Diffuse-Fire (FDF) threshold model. Numerical simulations of the model in one and two dimensions (with stores arranged on both regular and disordered lattices) illustrate that stochastic calcium release leads to the spontaneous production of calcium sparks that may merge to form saltatory waves. Illustrations of spreading circular waves, spirals and more irregular waves are presented. Furthermore, receptor noise is shown to generate a form of array enhanced coherence resonance whereby all calcium stores release periodically and simultaneously.
Resumo:
The study of forest re activity, in its several aspects, is essencial to understand the phenomenon and to prevent environmental public catastrophes. In this context the analysis of monthly number of res along several years is one aspect to have into account in order to better comprehend this tematic. The goal of this work is to analyze the monthly number of forest res in the neighboring districts of Aveiro and Coimbra, Portugal, through dynamic factor models for bivariate count series. We use a bayesian approach, through MCMC methods, to estimate the model parameters as well as to estimate the common latent factor to both series.
Resumo:
In this paper we establish, from extensive numerical experiments, that the two dimensional stochastic fire-diffuse-fire model belongs to the directed percolation universality class. This model is an idealized model of intracellular calcium release that retains the both the discrete nature of calcium stores and the stochastic nature of release. It is formed from an array of noisy threshold elements that are coupled only by a diffusing signal. The model supports spontaneous release events that can merge to form spreading circular and spiral waves of activity. The critical level of noise required for the system to exhibit a non-equilibrium phase-transition between propagating and non-propagating waves is obtained by an examination of the \textit{local slope} $\delta(t)$ of the survival probability, $\Pi(t) \propto \exp(- \delta(t))$, for a wave to propagate for a time $t$.
Resumo:
Abstract not available
Resumo:
INTRODUCTION AND AIMS: Research highlights the need to better understand the impact of alcohol-related harm on families and communities. Scottish policy initiatives to reduce alcohol consumption and alcohol-related harm include the planned introduction of a minimum unit price for alcohol. We aimed to explore existing and proposed changes in alcohol policy, from the standpoint of heavy drinkers, through accounts of their involvement and repercussions for family and friends. DESIGN AND METHODS: Interviews were conducted with 20 heavy drinkers, recruited from hospital alcohol treatment centres in Scotland's two largest cities. Participants were part of a larger longitudinal mixed methods study. Interviews explored experiences of alcohol-related harm and the impact, or potential impact, of alcohol policy changes on drinking patterns, risk-taking, consumption and wellbeing. Data coded for 'family and friends' were thematically analysed using a constant comparison method. RESULTS: Family and friends were portrayed as important for aiding moderation and abstinence, but more often for sustaining continued heavy drinking. Heavy drinkers with complex needs and those living in deprived communities suggested that increased alcohol prices could exacerbate the detrimental effect on their health and social circumstances, and that of their family, should their consumption remain excessive. DISCUSSION AND CONCLUSIONS: Population level policy initiatives to reduce alcohol consumption, such as minimum unit pricing, will impact on the families and social networks of heavy drinkers in addition to the drinker. The most vulnerable may be affected disproportionately. Alcohol policy changes and evaluations need to consider consequences for drinkers, families and communities. [O'May F, Whittaker A, Black H, Gill J. The families and friends of heavy drinkers: Caught in the cross-fire of policy change?
Resumo:
Effects of fire on biogeochemical cycling in terrestrial ecosystem are widely acknowledged, while few studies have focused on the bacterial community under the disturbance of long-term frequent prescribed fire. In this study, three treatments (burning every two years (B2), burning every four years (B4) and no burning (B0)) were applied for 38 years in an Australian wet sclerophyll forest. Results showed that bacterial alpha diversity (i.e. bacterial OTU) in the top soil (0-10 cm) was significantly higher in the B2 treatment compared with the B0 and B4 treatments. Non-metric multidimensional analysis (NMDS) of bacterial community showed clear separation of the soil bacterial community structure among different fire frequency regimes and between the depths. Different frequency fire did not have a substantial effect on bacterial composition at phylum level or bacterial 16S rRNA gene abundance. Soil pH and C:N ratio were the major drivers for bacterial community structure in the most frequent fire treatment (B2), while other factors (EC, DOC, DON, MBC, NH 4 +, TC and TN) were significant in the less frequent burning and no burning treatments (B4 and B0). This study suggested that burning had a dramatic impact on bacterial diversity but not abundance with more frequent fire.
Resumo:
An experimental and numerical study of turbulent fire suppression is presented. For this work, a novel and canonical facility has been developed, featuring a buoyant, turbulent, methane or propane-fueled diffusion flame suppressed via either nitrogen dilution of the oxidizer or application of a fine water mist. Flames are stabilized on a slot burner surrounded by a co-flowing oxidizer, which allows controlled delivery of either suppressant to achieve a range of conditions from complete combustion through partial and total flame quenching. A minimal supply of pure oxygen is optionally applied along the burner to provide a strengthened flame base that resists liftoff extinction and permits the study of substantially weakened turbulent flames. The carefully designed facility features well-characterized inlet and boundary conditions that are especially amenable to numerical simulation. Non-intrusive diagnostics provide detailed measurements of suppression behavior, yielding insight into the governing suppression processes, and aiding the development and validation of advanced suppression models. Diagnostics include oxidizer composition analysis to determine suppression potential, flame imaging to quantify visible flame structure, luminous and radiative emissions measurements to assess sooting propensity and heat losses, and species-based calorimetry to evaluate global heat release and combustion efficiency. The studied flames experience notable suppression effects, including transition in color from bright yellow to dim blue, expansion in flame height and structural intermittency, and reduction in radiative heat emissions. Still, measurements indicate that the combustion efficiency remains close to unity, and only near the extinction limit do the flames experience an abrupt transition from nearly complete combustion to total extinguishment. Measurements are compared with large eddy simulation results obtained using the Fire Dynamics Simulator, an open-source computational fluid dynamics software package. Comparisons of experimental and simulated results are used to evaluate the performance of available models in predicting fire suppression. Simulations in the present configuration highlight the issue of spurious reignition that is permitted by the classical eddy-dissipation concept for modeling turbulent combustion. To address this issue, simple treatments to prevent spurious reignition are developed and implemented. Simulations incorporating these treatments are shown to produce excellent agreement with the experimentally measured data, including the global combustion efficiency.
Resumo:
This work characterizes levels of eighteen polycyclic aromatic hydrocarbons (PAHs) in the breathing air zone of firefighters during their regular work shift at eight Portuguese fire stations, and the firefighters' total internal dose by six urinary monohydroxyl metabolites (OH-PAHs). Total PAHs (ΣPAHs) concentrations varied widely (46.4-428ng/m(3)), mainly due to site specificity (urban/rural) and characteristics (age and layout) of buildings. Airborne PAHs with 2-3 rings were the most abundant (63.9-95.7% ΣPAHs). Similarly, urinary 1-hydroxynaphthalene and 1-hydroxyacenaphthene were the predominant metabolites (66-96% ΣOH-PAHs). Naphthalene contributed the most to carcinogenic ΣPAHs (39.4-78.1%) in majority of firehouses; benzo[a]pyrene, the marker of carcinogenic PAHs, accounted with 1.5-10%. Statistically positive significant correlations (r≥0.733, p≤0.025) were observed between ΣPAHs and urinary ΣOH-PAHs for firefighters of four fire stations suggesting that, at these sites, indoor air was their major exposure source of PAHs. Firefighter's personal exposure to PAHs at Portuguese fire stations were well below the existent occupational exposure limits. Also, the quantified concentrations of post-shift urinary 1-hydroxypyrene in all firefighters were clearly lower than the benchmark level (0.5μmol/mol) recommended by the American Conference of Governmental Industrial Hygienists.
Resumo:
The discovery of the Red Imported Fire ants (Solenopsis invicta) in Brisbane on 22 February 2001 sent shock waves through urban and rural communities alike. This article is an attempt to address the often repeated question ‘What will become of Australia's unique fauna if they spread along Australia's eastern seaboard?
Resumo:
O fogo é um processo frequente nas paisagens do norte de Portugal. Estudos anteriores mostraram que os bosques de azinheira (Quercus rotundifolia) persistem após a passagem do fogo e ajudam a diminuir a sua intensidade e taxa de propagação. Os principais objetivos deste estudo foram compreender e modelar o efeito dos bosques de azinheira no comportamento do fogo ao nível da paisagem da bacia superior do rio Sabor, localizado no nordeste de Portugal. O impacto dos bosques de azinheira no comportamento do fogo foi testado em termos de área e configuração de acordo com cenários que simulam a possível distribuição destas unidades de vegetação na paisagem, considerando uma percentagem de ocupação da azinheira de 2.2% (Low), 18.1% (Moderate), 26.0% (High), e 39.8% (Rivers). Estes cenários tiveram como principal objetivo testar 1) o papel dos bosques de azinheira no comportamento do fogo e 2) de que forma a configuração das manchas de azinheira podem ajudar a diminuir a intensidade da linha de fogo e área ardida. Na modelação do comportamento do fogo foi usado o modelo FlamMap para simular a intensidade de linha do fogo e taxa de propagação do fogo com base em modelos de combustível associados a cada ocupação e uso do solo presente na área de estudo, e também com base em fatores topográficos (altitude, declive e orientação da encosta) e climáticos (humidade e velocidade do vento). Foram ainda usados dois modelos de combustível para a ocupação de azinheira (áreas interiores e de bordadura), desenvolvidos com base em dados reais obtidos na região. Usou-se o software FRAGSATS para a análise dos padrões espaciais das classes de intensidade de linha do fogo, usando-se as métricas Class Area (CA), Number of Patches (NP) e Large Patches Index (LPI). Os resultados obtidos indicaram que a intensidade da linha de fogo e a taxa de propagação do fogo variou entre cenários e entre modelos de combustível para o azinhal. A intensidade média da linha de fogo e a taxa média de propagação do fogo decresceu à medida que a percentagem de área de bosques de azinheira aumentou na paisagem. Também foi observado que as métricas CA, NP e LPI variaram entre cenários e modelos de combustível para o azinhal, decrescendo quando a percentagem de área de bosques de azinheira aumentou. Este estudo permitiu concluir que a variação da percentagem de ocupação e configuração espacial dos bosques de azinheira influenciam o comportamento do fogo, reduzindo, em termos médios, a intensidade da linha de fogo e a taxa de propagação, sugerindo que os bosques de azinhal podem ser usados como medidas silvícolas preventivas para diminuir o risco de incêndio nesta região.
Resumo:
"Report no. USCG/NTSB-MAR-75-6."
Resumo:
Wood is considered an ideal solution for floors and roofs building construction, due the mechanical and thermal properties, associated with acoustic conditions. These constructions have good sound absorption, heat insulation and relevant architectonic characteristics. They are used in many civil applications: concert and conference halls, auditoriums, ceilings, walls… However, the high vulnerability of wooden elements submitted to fire conditions requires the evaluation of its structural behaviour with accuracy. The main objective of this work is to present a numerical model to assess the fire resistance of wooden cellular slabs with different perforations. Also the thermal behaviour of the wooden slabs will be compared considering different material insulation, with different sizes, inside the cavities. A transient thermal analysis with nonlinear material behaviour will be solved using ANSYS© program. This study allows to verify the fire resistance, the temperature evolution and the char-layer, throughout a wooden cellular slab with perforations and considering the insulation effect inside the cavities.
Resumo:
The thermal loading of an open car park building structure is going to be analysed, based on different fire scenarios that depend on the type of vehicle (different heat release rate). The compartment is going to be fixed and the thermal effect on beams is going to be analysed, depending on the vehicle position. The result of simple calculation method will be used to determine several temperature-time curves. The simple calculation method (Hasemi method) is also to be compared with the calculations of the Elefir-EN calculation program to analyse the thermal effect of the localized fire on beams.
Resumo:
The most common method of achieve the required fire resistance is by the use of passive fire protection systems, being intumescent coatings the fire protection material frequently used. These are usually considered thin film coatings as they are applied with a dry film thickness (DFT) between 0.3-3 [mm]. The required DFT is obtained by experimental fire resistance tests performed to assess the contribution of this reactive fire protection material to the steel member fire resistance. This tests are done after dry coating and a short time period of atmospheric conditioning, at constant temperature and humidity. As the coatings formulation is mainly made from polymeric basis compounds, it is expected that the environmental factors, such temperature, humidity and UV radiation (UVA and UVB) significantly affect the intumescent coating fire protection performance and its durability. This work presents a research study about the effects of aging on the fire protection performance of intumescent coatings. A commercial water based coating is submitted to an accelerated aging cycle, using a QUV Accelerated Weathering Tester. This tests aim to simulate 10 years of the coating natural aging. The coating durability is tested comparing the fire protection of small steel samples submitted to a radiant heat flux exposure from a cone calorimeter. In total, 28 tests were performed on intumescent coating protected steel specimens, of which 14 specimens were tested before the hydrothermal aging test and other 14 after accelerated aging. The experimental tests results of the steel temperature evolution shows that increasing the intumescent dry coating film thickness, the fire resistance time increases. After the accelerated aging cycles, the coating lose their ability to expand, resulting in an increase of the steel temperature of approximately 200 [ºC], compared to the samples without aging.
Resumo:
Partially encased columns have significant fire resistant. However, it is not possible to assess the fire resistance of such members simply by considering the temperature of the steel. The presence of concrete increases the mass and thermal inertia of the member and the variation of temperature within the cross section, in both the steel and concrete components. The annex G of EN1994-1-2 allows to calculate the load carrying capacity of partially encased columns, for a specific fire rating time, considering the balanced summation method. New formulas will be used to calculate the plastic resistance to axial compression and the effective flexural stiffness. These two parameters are used to calculate the buckling resistance. The finite element method is used to compare the results of the elastic critical load for different fire ratings of 30 and 60 minutes. The buckling resistance is also calculated by the finite element method, using an incremental and iterative procedure. This buckling resistance is also compared with the simple calculation method, evaluating the design buckling curve that best fits the results.