940 resultados para Explanatory power
Resumo:
In this paper an investigation is reported on Siemens-power-metal-oxide-semiconductor (SIPMOS) transistors of both p and n channel types, for their suitability for cryogenic applications. The drain characteristics, temperature dependence of Rds(on) and switching behaviour have been studied in the temperature range 4.2 – 300 K in BSS91 and BSS92 MOSFETs. The experiments reveal that these types of power transistors are well suited for operations down to ≈ 30 K. However, below 30 K the operating characteristics make them unsuitable for application. This arises because of carrier freeze-out in the n− region on the substrate, which forms a drain.
Resumo:
An extensive electricity transmission network facilitates electricity trading between Finland, Sweden, Norway and Denmark. Currently most of the area's power generation is traded at NordPool, where the trading volumes have steadily increased since the early 1990's, when the exchange was founded. The Nordic electricity is expected to follow the current trend and further integrate with the other European electricity markets. Hydro power is the source for roughly a half of the supply in the Nordic electricity market and most of the hydro is generated in Norway. The dominating role of hydro power distinguishes the Nordic electricity market from most of the other market places. Production of hydro power varies mainly due to hydro reservoirs and demand for electricity. Hydro reservoirs are affected by water inflows that differ each year. The hydro reservoirs explain remarkably the behaviour of the Nordic electricity markets. Therefore among others, Kauppi and Liski (2008) have developed a model that analyzes the behaviour of the markets using hydro reservoirs as explanatory factors. Their model includes, for example, welfare loss due to socially suboptimal hydro reservoir usage, socially optimal electricity price, hydro reservoir storage and thermal reservoir storage; that are referred as outcomes. However, the model does not explain the real market condition but rather an ideal situation. In the model the market is controlled by one agent, i.e. one agent controls all the power generation reserves; it is referred to as a socially optimal strategy. Article by Kauppi and Liski (2008) includes an assumption where an individual agent has a certain fraction of market power, e.g. 20 % or 30 %. In order to maintain the focus of this thesis, this part of their paper is omitted. The goal of this thesis is two-fold. Firstly we expand the results from the socially optimal strategy for years 2006-08, as the earlier study finishes in 2005. The second objective is to improve on the methods from the previous study. This thesis results several outcomes (SPOT-price and welfare loss, etc.) due to socially optimal actions. Welfare loss is interesting as it describes the inefficiency of the market. SPOT-price is an important output for the market participants as it often has an effect on end users' electricity bills. Another function is to modify and try to improve the model by means of using more accurate input data, e.g. by considering pollution trade rights effect on input data. After modifications to the model, new welfare losses are calculated and compared with the same results before the modifications. The hydro reservoir has the higher explanatory significance in the model followed by thermal power. In Nordic markets, thermal power reserves are mostly nuclear power and other thermal sources (coal, natural gas, oil, peat). It can be argued that hydro and thermal reservoirs determine electricity supply. Roughly speaking, the model takes into account electricity demand and supply, and several parameters related to them (water inflow, oil price, etc.), yielding finally the socially optimal outcomes. The author of this thesis is not aware of any similar model being tested before. There have been some other studies that are close to the Kauppi and Liski (2008) model, but those have a somewhat different focus. For example, a specific feature in the model is the focus on long-run capacity usage that differs from the previous studies on short-run market power. The closest study to the model is from California's wholesale electricity markets that, however, uses different methodology. Work is constructed as follows.
Resumo:
A generalized two‐dimensional flow‐radiation coupled model to extract power from a gasdynamic laser is proposed. The model is used for the study of power extraction from a 9.4‐μm CO2 downstream‐mixing gasdynamic laser, where a cold CO2+H2 stream is mixed with a vibrationally excited N2 stream at the nozzle exits. This model is developed by coupling radiation with the two‐dimensional, unsteady, laminar and viscous flow modeling needed for such systems. The analysis showed that the steady‐state value of 9.4‐μm intensity as high as 5×107 W/m2 can be obtained from the system studied. The role of H2 relaxant in the power extraction process has also been investigated.
Resumo:
The study analyzes the effort to build political legitimacy in the Republic of Turkey by ex-ploring a group of influential texts produced by Kemalist writers. The study explores how the Kemalist regime reproduced certain long-lasting enlightenment meta-narrative in its effort to build political legitimacy. Central in this process was a hegemonic representation of history, namely the interpretation of the Anatolian Resistance Struggle of 1919 1922 as a Turkish Revolution executing the enlightenment in the Turkish nation-state. The method employed in the study is contextualizing narratological analysis. The Kemalist texts are analyzed with a repertoire of concepts originally developed in the theory of narra-tive. By bringing these concepts together with epistemological foundations of historical sciences, the study creates a theoretical frame inside of which it is possible to highlight how initially very controversial historical representations in the end manage to construct long-lasting, emotionally and intellectually convincing bases of national identity for the secular middle classes in Turkey. The two most important explanatory concepts in this sense are di-egesis and implied reader. The diegesis refers to the ability of narrative representation to create an inherently credible story-world that works as the basis of national community. The implied reader refers to the process where a certain hegemonic narrative creates a formula of identification and a position through which any individual real-world reader of a story can step inside the narrative story-world and identify oneself as one of us of the national narra-tive. The study demonstrates that the Kemalist enlightenment meta-narrative created a group of narrative accruals which enabled generations of secular middle classes to internalize Kemalist ideology. In this sense, the narrative in question has not only worked as a tool utilized by the so-called Kemalist state-elite to justify its leadership, but has been internalized by various groups in Turkey, working as their genuine world-view. It is shown in the study that secular-ism must be seen as the core ingredient of these groups national identity. The study proposes that the enlightenment narrative reproduced in the Kemalist ideology had its origin in a simi-lar totalizing cultural narrative created in and for Europe. Currently this enlightenment project is challenged in Turkey by those who are in an attempt to give religion a greater role in Turkish society. The study argues that the enduring practice of legitimizing political power through the enlightenment meta-narrative has not only become a major factor contributing to social polarization in Turkey, but has also, in contradiction to the very real potentials for crit-ical approaches inherent in the Enlightenment tradition, crucially restricted the development of critical and rational modes of thinking in the Republic of Turkey.
Resumo:
This paper proposes a method of designing fixed parameter decentralized power system stabilizers (PSS) for interconnected multi-machine power systems. Conventional design technique using a single machine infinite bus approximation involves the frequency response estimation called the GEP(s) between the AVR input and the resultant electrical torque. This requires the knowledge of equivalent external reactance and infinite bus voltage or their estimated values at each machine. Other design techniques using P-Vr characteristics or residues are based on complete system information. In the proposed method, information available at the high voltage bus of the step-up transformer is used to set up a modified Heffron-Phillip's model. With this model it is possible to decide the structure of the PSS compensator and tune its parameters at each machine in the multi-machine environment, using only those signals that are available at the generating station. The efficacy of the proposed design technique has been evaluated on three of the most widely used test systems. The simulation results have shown that the performance of the proposed stabilizer is comparable to that which could be obtained by conventional design but without the need for the estimation and computation of external system parameters.
Resumo:
This paper is concerned with the influence of different levels of complexity in modelling various constituent subsystems on the dynamic stability of power systems compensated by static var systems (SVS) operating on pure voltage control. The system components investigated include thyristor controlled reactor (TCR) transients, SVS delays, network transients, the synchronous generator and automatic voltage regulator (AVR). An overall model is proposed which adequately describes the system performance for small signal perturbations. The SVS performance is validated through detailed nonlinear simulation on a physical simulator.
Resumo:
Torsional interactions can occur due to the speed input Power System Stabilizer (PSS) that are primarily used to damp low frequency oscillations. The solution to this problem can be either in the form of providing a torsional filter or developing an alternate signal for the PSS. This paper deals with the formulation of a linearized state space model of the system and study of the interactions using eigenvalue analysis. The effects of the parameters of PSS and control signals on the damping of torsional modes are investigated.
Resumo:
This study aims at understanding the need for decentralized power generation systems and to explore the potential, feasibility and environmental implications of biomass gasifier-based electricity generation systems for village electrification. Electricity needs of villages are in the range of 5–20 kW depending on the size of the village. Decentralized power generation systems are desirable for low load village situations as the cost of power transmission lines is reduced and transmission and distribution losses are minimised. A biomass gasifier-based electricity generation system is one of the feasible options; the technology is readily available and has already been field tested. To meet the lighting and stationary power needs of 500,000 villages in India the land required is only 16 Mha compared to over 100 Mha of degraded land available for tree planting. In fact all the 95 Mt of woody biomass required for gasification could be obtained through biomass conservation programmes such as biogas and improved cook stoves. Thus dedication of land for energy plantations may not be required. A shift to a biomass gasifier-based power generation system leads to local benefits such as village self reliance, local employment and skill generation and promotion of in situ plant diversity plus global benefits like no net CO2 emission (as sustainable biomass harvests are possible) and a reduction in CO2 emissions (when used to substitute thermal power and diesel in irrigation pump sets).
Resumo:
This paper presents a physical explanation of the phenomenon of low frequency oscillations experienced in power systems. A brief account of the present practice of providing fixed gain power system stabilizers (PSS) is followed by a summary of some of the recent design proposals for adaptive PSS. A novel PSS based on the effort of cancelling the negative damping torque produced by the automatic voltage regulator (AVR) is presented along with some recent studies on a multimachine system using a frequency identification technique.
Resumo:
Former President of Finland Urho Kekkonen was not only a powerful politician but also a well-known sportsman and keep-fit enthusiast. The president’s sports hobbies were covered and celebrated in the media and thus became an integral part of his public persona. This paper looks at Kekkonen’s athletic and able-bodied image and its significance for his power from the perspective of gender. In his exercise activities, Kekkonen was able to display his bodily prowess and demonstrate his version of masculinity, which emphasized both physical and mental strength. The union of mind and muscle in turn buttressed his political ascendancy. Kekkonen’s athletic body served as a cornerstone of his dominance over his country and, simultaneously, as a shield protecting Finland from both internal and external threats. Furthermore, Kekkonen’s sports performances were essential elements in the myth that was created around the president during his term and which was carefully conserved after his fall from power. Drawing upon scholarship on men and masculinities, this paper reassesses the still-effective mythical image of Kekkonen as an invincible superman. The article reveals the performative nature of his athletic activities and shows that in part, his pre-eminence in them was nothing more than theatre enacted by him and his entourage. Thus, Kekkonen’s superior and super-masculine image was actually surprisingly vulnerable and dependent on the success of the performance. The president’s ageing, in particular, demonstrates the fragility of his displays of prowess, strength and masculinity, and shows how fragile the entanglement of body and power can be.
Resumo:
High power converters are used in variable speed induction motor drive applications. Riding through a short term power supply glitch is becoming an important requirement in these power converters. The power converter uses a large number of control circuit boards for its operation. The control power supply need to ensure that any glitch in the grid side does not affect any of these control circuit boards. A power supply failure of these control cards results in shut down of the entire system. The paper discusses the ride through system developed to overcome voltage sags and short duration outages at the power supply terminals of the control cards in these converters. A 240VA non-isolated, bi-directional buck-boost converter has been designed to be used along with a stack of ultracapacitors to achieve the same. A micro-controller based digital control platform made use of to achieve the control objective. The design of the ultracapacitor stack and the bidirectional converter is described the performance of the experimental set-up is evaluated.
Resumo:
Clustered VLIW architectures solve the scalability problem associated with flat VLIW architectures by partitioning the register file and connecting only a subset of the functional units to a register file. However, inter-cluster communication in clustered architectures leads to increased leakage in functional components and a high number of register accesses. In this paper, we propose compiler scheduling algorithms targeting two previously ignored power-hungry components in clustered VLIW architectures, viz., instruction decoder and register file. We consider a split decoder design and propose a new energy-aware instruction scheduling algorithm that provides 14.5% and 17.3% benefit in the decoder power consumption on an average over a purely hardware based scheme in the context of 2-clustered and 4-clustered VLIW machines. In the case of register files, we propose two new scheduling algorithms that exploit limited register snooping capability to reduce extra register file accesses. The proposed algorithms reduce register file power consumption on an average by 6.85% and 11.90% (10.39% and 17.78%), respectively, along with performance improvement of 4.81% and 5.34% (9.39% and 11.16%) over a traditional greedy algorithm for 2-clustered (4-clustered) VLIW machine. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Large external memory bandwidth requirement leads to increased system power dissipation and cost in video coding application. Majority of the external memory traffic in video encoder is due to reference data accesses. We describe a lossy reference frame compression technique that can be used in video coding with minimal impact on quality while significantly reducing power and bandwidth requirement. The low cost transformless compression technique uses lossy reference for motion estimation to reduce memory traffic, and lossless reference for motion compensation (MC) to avoid drift. Thus, it is compatible with all existing video standards. We calculate the quantization error bound and show that by storing quantization error separately, bandwidth overhead due to MC can be reduced significantly. The technique meets key requirements specific to the video encode application. 24-39% reduction in peak bandwidth and 23-31% reduction in total average power consumption are observed for IBBP sequences.