928 resultados para Energy dispersive X ray analysis
Resumo:
Suramin is a highly charged polysulfonated napthylurea that interferes in a number of physiologically relevant processes such as myotoxicity, blood coagulation and several kinds of cancers. This synthetic compound was complexed with a myotoxic Lys49 PLA(2) from Bothrops asper venom and crystallized by the hanging-drop vapor diffusion method at 18 degreesC. The crystals belong to the orthorhombic space group P2(1)2(1)2(1), with unit cell parameters a=49.05, b=63.84 and c=85.67 Angstrom, Diffraction data was collected to 1.78 Angstrom. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Synchrotron X-ray powder diffraction (XRPD) data were collected for the silver(I)-aspartame complex [Ag(C14H17N2O5)]center dot 1/2 H2O. The complex was obtained from a stoichiometric mixture of aspartame (3-amino-N-(alpha-carboxyphenethyl)-succinamic acid N-methyl ester, C14H18N2O5), Na2CO3, and AgNO3. Indexing using Crysfire and Chekcell proposed an orthorhombic unit cell with space group P222(1). The lattice parameters are a = 12.4750(1) angstrom, b = 21.60614(14) angstrom, and c = 4.88888(9) angstrom. (C) 2006 International Centre for Diffraction Data.
Resumo:
X-ray powder diffraction data collected for the complex silver(I) cyclamate [Ag(C6H12NO3S)] are reported. This material was obtained from a stoichiometric mixture of sodium cyclamate and AgNO3. The analysis of the data using the Le Bail method showed that the complex has monoclinic symmetry (space group C2/c). The unit cell parameters are a=31.85852(16) angstrom, b=6.25257(6) angstrom c = 8.46165(7) angstrom, and beta=95.7651(5)degrees. (C) 2007 International Centre for Diffraction Data.
Resumo:
Results of differential scanning calometry (DSC), x-ray diffraction (XRD), and F-19 nuclear magnetic resonance (NMR) of InF3-based glasses, treated at different temperatures, ranging from glass transition temperature (T-g) to crystallization temperature (T-c), are reported. The main features of the experimental results are as follows. DSC analysis emphasizes several steps in the crystallization process. Heat treatment at temperatures above T-g enhances the nucleation of the first growing phases but has little influence on the following ones. XRD results show that several crystalline phases are formed, with solid state transitions when heated above 680 K, the F-19 NMR results show that the spin-lattice relaxation, for the glass samples heat treated above 638 K, is described by two time constants. For samples treated below this temperature a single time constant T-1 was observed. Measurements of the F-19 spin-lattice relaxation time (T-1), as a function of temperature,made possible the identification of the mobile fluoride ions. The activation energy, for the ionic motion, in samples treated at crystallization temperature was found to be 0.18 +/- 0.01 eV. (C) 1998 American Institute of Physics.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this work, initial crystallographic studies of human haemoglobin (Hb) crystallized in isoionic and oxygen-free PEG solution are presented. Under these conditions, functional measurements of the O-2-linked binding of water molecules and release of protons have evidenced that Hb assumes an unforeseen new allosteric conformation. The determination of the high-resolution structure of the crystal of human deoxy-Hb fully stripped of anions may provide a structural explanation for the role of anions in the allosteric properties of Hb and, particularly, for the influence of chloride on the Bohr effect, the mechanism by which Hb oxygen affinity is regulated by pH. X-ray diffraction data were collected to 1.87 Angstrom resolution using a synchrotron-radiation source. Crystals belong to the space group P2(1)2(1)2 and preliminary analysis revealed the presence of one tetramer in the asymmetric unit. The structure is currently being refined using maximum-likelihood protocols.
Resumo:
The unique carbohydrate-binding property of lectins makes them invaluable tools in biomedical research. Here, we report the purification, partial primary structure, carbohydrate affinity characterization, crystallization, and preliminary X-ray diffraction analysis of a lactose-specific lectin from Cymbosema roseum seeds (CRLII). Isolation and purification of CRLII was performed by a single step using a Sepharose-4B-lactose affinity chromatography column. The carbohydrate affinity characterization was carried using assays for hemagglutination activity and inhibition. CRLII showed hemagglutinating activity toward rabbit erythrocytes. O-glycoproteins from mucine mucopolysaccharides showed the most potent inhibition capacity at a minimum concentration of 1.2 A mu g mL(-1). Protein sequencing by mass spectrometry was obtained by the digestion of CRLII with trypsin, Glu-C, and AspN. CRLII partial protein sequence exhibits 46% similarity with the ConA-like alpha chain precursor. Suitable protein crystals were obtained with the hanging-drop vapor-diffusion method with 8% ethylene glycol, 0.1 M Tris-HCl pH 8.5, and 11% PEG 8,000. The monoclinic crystals belong to space group P2(1) with unit cell parameters a = 49.4, b = 89.6, and c = 100.8 A....
Resumo:
Hemoglobin remains, despite the enormous amount of research involving this molecule, as a prototype for allosteric models and new conformations. Functional studies carried out on Hemoglobin-I from the South-American Catfish Liposarcus anisitsi [1] suggest the existence of conformational states beyond those already described for human hemoglobin, which could be confirmed crystallographically. The present work represents the initial steps towards that goal.
Resumo:
X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe the development of a low cost micro-CT X-ray scanner that is being developed for nondestructive testing. This tomograph operates using a microfocus X-ray source and contains a silicon photodiode as detectors. The performance of the system, by its spatial resolution, has been estimated through its Modulation Transfer Function - MTF and the obtained value at 10% of MTF is 661 μm. It was built as a general purpose nondestructive testing device. © 2009 American Institute of Physics.
Resumo:
The reaction of 2,6-diformylpyridine-bis(benzoylhydrazone) [dfpbbh] and 2,6-diformylpyridine-bis(4-phenylsemicarbazone) [dfpbpsc] with lanthanides salts yielded the new chelates complexes [Eu(dfpbpsc-H +) 2]NO 3 (1), [Dy(fbhmp) 2][Dy(dfpbbh-2H +) 2]·2EtOH·2H 2O (fbhmp = 2-formylbenzoylhydrazone-6-methoxide-pyridine; Ph = phenyl; Py = pyridine; Et = ethyl) and [Er 2(dfpbbh-2H +) 2(μ-NO 3)(H 2O) 2(OH)]·H 2O. X-ray diffraction analysis was employed for the structural characterization of the three chelate complexes. In the case of complex 1, optical, synthetic and computational methods were also exploited for ground state structure determinations and triplet energy level of the ligand and HOMO-LUMO calculations, as well as for a detailed study of its luminescence properties. © 2010 Elsevier Ltd. All rights reserved.
Resumo:
The present paper is a comprehensive study concerning Fe K-edge X-ray absorption spectroscopy (XAS) measurements, which were performed to characterize the local structure of (1 - x)Pb(Fe2/3W1/3)O 3-xPbTiO3 samples as a function of temperature and PbTiO3 content. Results obtained by the fits of extended X-ray absorption fine structure consist with rhombohedral symmetry for Pb(Fe 2/3W1/3)O3 composition at temperatures lower than room temperature. This result is in apparent disagreement with X-ray and neutron diffraction characterization which have been reported. This apparent disagreement is related to the fact that XAS probes the short-range order, whereas X-ray diffraction provides structural information about the average structure. Moreover, as the PbTiO3 content increases, a disorder has been detected at local structure of the FeO6 octahedron. Analysis of X-ray absorption near edge structure spectra did not show modifications in intensity nor energy of transitions. © 2013 American Institute of Physics.
Resumo:
The X-ray Fluorescence (XRF) analysis is a technique for the qualitative and quantitative determination of chemical constituents in a sample. This method is based on detection of the characteristic radiation intensities emitted by the elements of the sample, when properly excited. A variant of this technique is the Total Reflection X-ray Fluorescence (TXRF) that utilizes electromagnetic radiation as excitation source. In total reflection of X-ray, the angle of refraction of the incident beam tends to zero and the refracted beam is tangent to the sample support interface. Thus, there is a minimum angle of incidence at which no refracted beam exists and all incident radiation undergoes total reflection. In this study, we evaluated the influence of the energy variation of the beam of incident x-rays, using the MCNPX code (Monte Carlo NParticle) based on Monte Carlo method. © 2013 AIP Publishing LLC.
Resumo:
ABSTRACT: The present work uses multivariate statistical analysis as a form of establishing the main sources of error in the Quantitative Phase Analysis (QPA) using the Rietveld method. The quantitative determination of crystalline phases using x ray powder diffraction is a complex measurement process whose results are influenced by several factors. Ternary mixtures of Al2O3, MgO and NiO were prepared under controlled conditions and the diffractions were obtained using the Bragg-Brentano geometric arrangement. It was possible to establish four sources of critical variations: the experimental absorption and the scale factor of NiO, which is the phase with the greatest linear absorption coefficient of the ternary mixture; the instrumental characteristics represented by mechanical errors of the goniometer and sample displacement; the other two phases (Al2O3 and MgO); and the temperature and relative humidity of the air in the laboratory. The error sources excessively impair the QPA with the Rietveld method. Therefore it becomes necessary to control them during the measurement procedure.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)