973 resultados para Distribution transformer modeling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

[1] Comprehensive measurements are presented of the piezometric head in an unconfined aquifer during steady, simple harmonic oscillations driven by a hydrostatic clear water reservoir through a vertical interface. The results are analyzed and used to test existing hydrostatic and nonhydrostatic, small-amplitude theories along with capillary fringe effects. As expected, the amplitude of the water table wave decays exponentially. However, the decay rates and phase lags indicate the influence of both vertical flow and capillary effects. The capillary effects are reconciled with observations of water table oscillations in a sand column with the same sand. The effects of vertical flows and the corresponding nonhydrostatic pressure are reasonably well described by small-amplitude theory for water table waves in finite depth aquifers. That includes the oscillation amplitudes being greater at the bottom than at the top and the phase lead of the bottom compared with the top. The main problems with respect to interpreting the measurements through existing theory relate to the complicated boundary condition at the interface between the driving head reservoir and the aquifer. That is, the small-amplitude, finite depth expansion solution, which matches a hydrostatic boundary condition between the bottom and the mean driving head level, is unrealistic with respect to the pressure variation above this level. Hence it cannot describe the finer details of the multiple mode behavior close to the driving head boundary. The mean water table height initially increases with distance from the forcing boundary but then decreases again, and its asymptotic value is considerably smaller than that previously predicted for finite depth aquifers without capillary effects. Just as the mean water table over-height is smaller than predicted by capillarity-free shallow aquifer models, so is the amplitude of the second harmonic. In fact, there is no indication of extra second harmonics ( in addition to that contained in the driving head) being generated at the interface or in the interior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Variation in the concentration of virus in different parts of the plant has implications for virus-indexing programs. To allow more reliable detection of Sugarcane mosaic virus (SCMV), the distribution of the virus in sugarcane plants after artificial inoculation was studied using a reverse transcription polymerase chain reaction (RT-PCR) assay. Leaves of susceptible and moderately resistant sugarcane were mechanically inoculated with SCMV 6 weeks after planting. Weekly for 8 weeks after inoculation, plants were examined for mosaic symptoms and samples of leaves, roots and tillers were tested by RT-PCR to detect virus. SCMV moved from the point of inoculation to younger leaves, roots and tillers and eventually to leaves that emerged prior to inoculation. The pattern of SCMV distribution in moderately resistant and susceptible cultivars was not substantially different. However, the virus moved more slowly in the moderately resistant than in the susceptible cultivar. Young leaves proved to be the most suitable tissue for testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drying kinetics of low molecular weight sugars such as fructose, glucose, sucrose and organic acid such as citric acid and high molecular weight carbohydrate such as maltodextrin (DE 6) were determined experimentally using single drop drying experiments as well as predicted numerically by solving the mass and heat transfer equations. The predicted moisture and temperature histories agreed with the experimental ones within 6% average relative (absolute) error and average difference of +/- 1degreesC, respectively. The stickiness histories of these drops were determined experimentally and predicted numerically based on the glass transition temperature (T-g) of surface layer. The model predicted the experimental observations with good accuracy. A nonsticky regime for these materials during spray drying is proposed by simulating a drop, initially 120 mum in diameter, in a spray drying environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bituminous coal was pyrolyzed in a nitrogen stream in an entrained flow reactor at various temperatures from 700 to 1475 degreesC. Char samples were collected at different positions along the reactor. Each collected sample was oxidized nonisothermally in a TGA for reactivity determination. The reactivity of the coal char was found to decrease rapidly with residence time until 0.5 s, after which it decreased only slightly. On the bases of the reactivity data at various temperatures, a new approach was utilized to obtaining the true activation energy distribution function for thermal annealing without the assumption of any distribution function form or a constant preexponential factor. It appears that the true activation energy distribution function consists of two separate parts corresponding to different temperature ranges, suggesting different mechanisms in different temperature ranges. Partially burnt coal chars were also collected along the reactor when the coal was oxidized in air at various temperatures from 700 to 1475 degreesC. The collected samples were analyzed for the residual carbon content and the specific reaction rate was estimated. The characteristic time of thermal deactivation was compared with that of oxidation under realistic conditions. The characteristic times were found to be close to each other, indicating the importance of thermal deactivation during combustion of the coal studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bakeriella lata sp. nov. (Brazil, Rondônia), Bakeriella aurata sp. nov. (Brazil, Amazonas) and Bakeriella sulcaticeps sp. nov. (Brazil, Amazonas) are described and illustrated. New geographic records and variation data for B. cristata Evans, 1964, B. floridana Evans, 1964, B. flavicornis Kieffer, 1910, B. incompleta Azevedo, 1994, B. mira Evans, 1997, B. montivaga (Kieffer, 1910), B. olmeca Evans, 1964 and B. subcarinata Evans, 1965 are provided. The male of B. incompleta is described for the first time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variabilidade natural dos solos torna complexo o conhecimento de suas propriedades na elaboração de projetos geotécnicos, sendo a determinação da resistência ao cisalhamento não drenada um parâmetro importante nas análises de estabilidade de solos moles. Os ensaios de laboratório de cone e palheta, não convencionais, os ensaios de campo de palheta e piezocone e os ensaios de compressão simples e triaxial não adensado e não drenado foram utilizados para mensurar a resistência não drenada de uma camada de argila marinha mole localizada na planície costeira central brasileira. Os ensaios de laboratório foram realizados em amostras indeformadas coletadas com amostradores de pistão estacionário em vertical próxima à realização dos ensaios de campo. O sítio foi investigado preliminarmente por sondagens de simples reconhecimento, sendo apresentado o perfil estratigráfico por meio de modelagem computacional. Foram também realizados ensaios para caracterização física (análise granulométrica, teor de umidade, limites de liquidez e plasticidade, densidade real dos grãos) e mineralógica (difração de raios X), e ensaios de adensamento para obtenção do histórico de tensões e classificação de qualidade das amostras indeformadas. Os valores de resistência não drenada obtidos pelos ensaios de laboratório foram comparados ao perfil contínuo de resistência determinado empiricamente pelo ensaio de piezocone, com fator de cone Nkt calibrado pelo ensaio de palheta de campo, apresentando boa concordância, com a variabilidade natural do solo influenciando de forma preponderante a qualidade das amostras na variação entre os resultados. Os valores de resistência obtidos pelos ensaios de laboratório de cone e palheta foram comparados entre si, apresentando boa compatibilidade. Ambos, quando comparados ao ensaio de palheta de campo, não apresentaram boa concordância. Os resultados de resistência obtidos pelos ensaios de compressão simples e triaxial apresentaram boa compatibilidade com os resultados do ensaio de laboratório de cone, o que não ocorreu com os resultados do ensaio de laboratório de palheta. Na comparação entre a resistência normalizada pela tensão de sobreadensamento obtida pelos diversos métodos e algumas correlações empíricas da literatura internacional, foi observado para as amostras de solo com índice de plasticidade superior a 60% boa concordância com as correlações de Mesri (1975) e Jamiolkowski et al (1985). Os ensaios não convencionais apresentaram boa confiabilidade, que aliado a simplicidade e agilidade de execução, justificam a difusão destes na prática da investigação geotécnica brasileira como método alternativo para complementar e dar suporte às estimativas de resistência não drenada de solos moles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(vinylidene fluoride-trifluoethylene) electrospun membranes were obtained from a blend of dimethylformamide (DMF) and methylethylketone (MEK) solvents. The inclusion of the MEK to the solvent system promotes a faster solvent evaporation allowing complete polymer crystallization during the jet travelling between the tip and the grounded collector. Several processing parameters were systematically changed to study their influence on fiber dimensions. Applied voltage and inner needle diameter do not have large influence on the electrospun fiber average diameter but in the fiber diameter distribution. On the other hand, the increase of the distance between the needle tip to collector results in fibers with larger average diameter. Independently on the processing conditions, all mats are produced in the electroactive phase of the polymer. Further, MC-3T3-E1cell adhesion was not inhibited by the fiber mats preparation, indicating their potential use for biomedical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poly(hydroxybutyrate) (PHB) obtained from sugar cane was dissolved in a blend of chloroform and dimethylformamide (DMF) and electrospun at 40 ºC. By adding DMF to the solution, the electrospinning process for the PHB polymer becomes more stable, allowing complete polymer crystallization during the jet travelling between the tip and the grounded collector. The influence of processing parameters on fiber size and distribution was systematically studied. It was observed that an increase of tip inner diameter promotes a decrease of the fiber average size and a broader distribution. On the other hand, an increase of the electric field and flow rate produces an increase of fiber diameter until a maximum of ~2.0 m, but for electric fields higher than 1.5 kV.cm-1, a decrease of the fiber diameter was observed. Polymer crystalline phase seems to be independent of the processing conditions and a crystallinity degree of 53 % was found. Moreover, thermal degradation of the as-spun membrane occurs in single step degradation with activation energy of 91 kJ/mol. Furthermore, MC-3T3-E1 cell adhesion was not inhibited by the fiber mats preparation, indicating their potential use for biomedical applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work it is demonstrated that the capacitance between two cylinders increases with the rotation angle and it has a fundamental influence on the composite dielectric constant. The dielectric constant is lower for nematic materials than for isotropic ones and this can be attributed to the effect of the filler alignment in the capacitance. The effect of aspect ratio in the conductivity is also studied in this work. Finally, based on previous work and by comparing to results from the literature it is found that the electrical conductivity in this type of composites is due to hopping between nearest fillers resulting in a weak disorder regime that is similar to the single junction expression.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymers have become the reference material for high reliability and performance applications. In this work, a multi-scale approach is proposed to investigate the mechanical properties of polymeric based material under strain. To achieve a better understanding of phenomena occurring at the smaller scales, a coupling of a Finite Element Method (FEM) and Molecular Dynamics (MD) modeling in an iterative procedure was employed, enabling the prediction of the macroscopic constitutive response. As the mechanical response can be related to the local microstructure, which in turn depends on the nano-scale structure, the previous described multi-scale method computes the stress-strain relationship at every analysis point of the macro-structure by detailed modeling of the underlying micro- and meso-scale deformation phenomena. The proposed multi-scale approach can enable prediction of properties at the macroscale while taking into consideration phenomena that occur at the mesoscale, thus offering an increased potential accuracy compared to traditional methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fungal diseases are important factors limiting common bean yield. White mold is one of the main diseases caused by soil pathogens. The objective of this study was to quantify the distribution of a fungicide solution sprayed into the canopy of bean plants by spectrophotometry, using a boom sprayer with and without air assistance. The experiment was arranged in a 2 x 2 x 2 factorial (two types of nozzles, two application rates, and air assistance on and off) randomized block design with four replications. Air assistance influenced the deposition of solution on the bean plant and yield increased significantly with the increased rate of application and air assistance in the boom sprayer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the necessity of developing jatropha cultivation equipment, this work adjusted different mathematical models to experimental data obtained from the drying of jatropha seeds submitted to different drying conditions and selected the best model to describe the drying process. The experiment was carried out at the Federal Institute of Goiás - Rio Verde Campus. Seeds with initial moisture content of approximately 0.50 (kg water/kg dry matter) were dried in a forced air-ventilated oven, at temperatures of 45, 60, 75, 90 and 105°C to moisture content of 0.10 ± 0.005 (kg water/kg dry matter). The experimental data were adjusted to 11 mathematical models to represent the drying process of agricultural products. The models were compared using the coefficient of determination, chi-square test, relative mean error, estimated mean error and residual distribution. It was found that the increase in the air temperature caused a reduction in the drying time of seeds. The models Midilli and Two Terms were suitable to represent the drying process of Jatropha seeds and between them the use of the Midili model is recommended due to its greater simplicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus Carinatum is a deformity of the chest wall, characterized by an anterior protrusion of the sternum, often corrected surgically due to cosmetic motivation. This work presents an alternative approach to the current open surgery option, proposing a novel technique based on a personalized orthosis. Two different processes for the orthosis’ personalization are presented. One based on a 3D laser scan of the patient chest, followed by the reconstruction of the thoracic wall mesh using a radial basis function, and a second one, based on a computer tomography scan followed by a neighbouring cells algorithm. The axial position where the orthosis is to be located is automatically calculated using a Ray-Triangle intersection method, whose outcome is input to a pseudo Kochenek interpolating spline method to define the orthosis curvature. Results show that no significant differences exist between the patient chest physiognomy and the curvature angle and size of the orthosis, allowing a better cosmetic outcome and less initial discomfort

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pectus excavatum is the most common deformity of the thorax. Pre-operative diagnosis usually includes Computed Tomography (CT) to successfully employ a thoracic prosthesis for anterior chest wall remodeling. Aiming at the elimination of radiation exposure, this paper presents a novel methodology for the replacement of CT by a 3D laser scanner (radiation-free) for prosthesis modeling. The complete elimination of CT is based on an accurate determination of ribs position and prosthesis placement region through skin surface points. The developed solution resorts to a normalized and combined outcome of an artificial neural network (ANN) set. Each ANN model was trained with data vectors from 165 male patients and using soft tissue thicknesses (STT) comprising information from the skin and rib cage (automatically determined by image processing algorithms). Tests revealed that ribs position for prosthesis placement and modeling can be estimated with an average error of 5.0 ± 3.6 mm. One also showed that the ANN performance can be improved by introducing a manually determined initial STT value in the ANN normalization procedure (average error of 2.82 ± 0.76 mm). Such error range is well below current prosthesis manual modeling (approximately 11 mm), which can provide a valuable and radiation-free procedure for prosthesis personalization.