1000 resultados para Construção da Nação


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the construction of an eletrical current source and of a probe to be used in the measurement of eletrical conductivity through a four-point probe method. These pieces of equipments can be obtained at the low price of US$ 50.00 and are adequate for eletrical conductivity measurements in the semiconductor range, that is from 10-1 to 10-6 S cm-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present experiment describes the preparation, characterization of n-butyl(pyridil)cobaloxime complex and its electrochemical property. The infrared and uv-visible absorption spectra were used to characterize the complex obtained. The infrared spectrum of the compound showed characteristics bands that indicated the formation of the Co-C chemical bond formation. The electronic absorption spectrum in acetonitrile showed transition bands attributed to p-p*, metal-to-ligand charge transfer, d-d transitions and charge transfer Co-C. The electrochemical property was investigated by the pulse differential voltammetry technique. Two oxidation processes: Co(I)/Co(II) at -423 mV and Co(II)/Co(III) at 752 mV were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we show how to build a piece of equipment for depositing thin films by the dip-coating process, using inexpensive components easily found on the market. This equipment allows us to control the dipping and pulling velocity at which the substrate is put in the film precursor solution, two very important parameters for obtain thin films. This article discusses the construction of the mechanical and electric parts of the equipment, a simple method to interface it to a computer and the development of the software to control the dip-coating parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple low-cost flow cell was developed, built and optimized in order to observe dynamic interfacial tension of continuous flow systems. Distinct materials can be used in one of the cell walls in order to observe the intermolecular forces between the flowing liquid and the chemical constitution of the walls. The fluorescence depolarization was evaluated using Rhodamine B as fluorescent probe seeded in ethylene glycol. The effects of the positioning angles on the data acquired across the cell are reported. The reproducibility of the data was evaluated with a spectrometer assembled in-house and the relative standard deviation was below 3%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A CPC (Compound Parabolic Concentrator) reactor was projected and constructed aiming to promote the degradation of the organic matter present in considerable volumes of aqueous effluents, under the action of solar radiation. The essays were done using a model effluent which consists of a mixture of fragments of a sodium salt of lignosulphonic acid possessing a mean molecular weigth of 52,000 Daltons, and a real effluent, from a chip board industry. The volume of effluent in each test was about 50 L. The tests involved heterogeneous (TiO2 P25 Degussa and formulations made from the association of TiO2 with a photosensitiser), and homogeneous (thermal and photochemical Fenton reactions) catalysis of the effluents. The results demonstrate the viability of application of this kind of reactor even when the load of organic pollutants is high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour of Nafion® polymeric membranes containing acid-base dyes, bromothymol blue (BB) and methyl violet (MV), were studied aiming at constructing an optical sensor for pH measurement. BB revealed to be inadequate for developing sensing phases due to the electrostatic repulsion between negative groups of their molecules and the negative charge of the sulfonate group of the Nafion®, which causes leaching of the dye from the membrane. On the other hand, MV showed to be suitable due to the presence of positive groups in its structure. The membrane prepared from a methanolic solution whose Nafion®/dye molar ratio was 20 presented the best analytical properties, changing its color from green to violet in the pH range from 0.6 to 3.0. The membrane can be prepared with good reproducibility, presenting durability of ca. 6 months and response time of 22 s, making possible its use for pH determination in flow analysis systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we present a new parametrization in molecular mechanics for studying iron complexes. This force field was implemented in the FORCES 2000 program, developed in our group for studying in coordination compounds of interest in bioinorganic chemistry. Mononuclear and dinuclear iron complexes were studied using this program with good success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new passive sampling system for monitoring NO2 in air has been developed to measure gas concentrations in indoor and outdoor air. The sampler is inexpensive, and easy to construct and operate. Nitrogen dioxide forms a derivative after reaction with a filter coated with triethanolamine and ethyleneglycol. The nitrogen dioxide derivative is extracted from the filter, and the concentration is determined by colorimetry. To test the sampler for measuring ambient level nitrogen dioxide, measurements were carried out inside homes and in a range of workplace environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biosensors were developed by immobilization of gilo (Solanum gilo) enzymatic extract on chitosan biopolymers using three different procedures: glutaraldehyde, carbodiimide/glutaraldehyde and epichlorohydrin/glutaraldehyde. The best biosensor performance was obtained after the immobilization of peroxidase on chitosan with epichlorohydrin/glutaraldehyde. Linear analytical curves for hydroquinone concentrations from 2.5x10-4 to 4.5x10-3 mol L-1 with a detection limit of 2.0x10-6 mol L-1 and recovery of hydroquinone ranging from 95.1 to 105% were obtained. The relative standard deviation was < 1.0 % for a solution of 3.0x10-4 mol L-1 hydroquinone and 2.0x10-3 mol L-1 hydrogen peroxide in 0.1 mol L-1 phosphate buffer solution at pH 7.0 (n=8). The lifetime of this biosensor was 6 months (at least 300 determinations).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objectivo deste estudo foi comparar os indicadores de sintomatologia psicológica, competências de resolução de problemas e de construção pessoal, quando avaliados no início e no final do primeiro ano da Universidade. Analisámos também os preditores quer de sintomatologia psicológica, quer de competências de resolução de problemas avaliadas no final do ano lectivo. Vinte e oito estudantes do primeiro ano da Universidade do Minho, preencheram uma medida de sintomatologia psicológica (SCL-90-R), uma medida de competências de resolução de problemas (IRP) e a grelha de repertório para análise da sua construção pessoal. Os resultados indicam uma diminuição significativa na sintomatologia e um aumento significativo da auto-estima, no segundo período de avaliação. Verificámos que a sintomatologia e as competências manifestadas no início do ano são, respectivamente, os melhores preditores de sintomatologia e competências no final do ano. Os resultados são discutidos sublinhando as implicações para a promoção da adaptação dos estudantes universitários.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discussion among teachers, students, and technicians about the destination of residues from chemistry laboratories led to a research project whose results were incorporated into a course in its daily practices. The treatment of the residues from argentimetric practices allowed us to establish cognitive relations of technological basis and of those related to the rising of the level of awareness about environmental aspects and social responsibility of chemistry professionals. The techniques and the results, from the economic point of view, namely that of value aggregation (metallic silver) and the conversion of the residue into input (potassium chromate solution) are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and low-cost flow cell with 30 cm optical path for spectrophotometric measurements is described. It presents desirable characteristics such as low attenuation of the radiation beam and internal volume (75 µL) comparable to that of a 1-cm conventional cell (80 µL). Despite the increase in optical path, the effect on sample dispersion was also similar to that attained in the commercial cell. The performance of the cell was assessed by the determination of phosphate based on the molybdenum blue method, yielding a linear response range between 0.05 and 0.8 mg L-1 phosphorus (r=0.999). The increase in sensitivity (30.4-fold) in comparison with that obtained with a conventional 1-cm flow cell agreed with that estimated by the Lambert-Beer law.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assembly of a photochemical reactor with six fluorescent lamps, used for photopolymerizations is described. This chamber presents a mobile support, allowing the placement of samples at different heights and a safety lock that interrupts the radiation, if it is opened during operation. The mirrored internal walls avoid the dispersion and non-uniform distribution of light. There is no high heating because the own character of the used lamps. All parts could be purchased in commerce with less than U$ 150,00. This reactor was successfully used for monolithic stationary phase photopolymerization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a projection spectrograph for use in optical spectroscopy classrooms demonstrations. The apparatus is based on an overhead projector and permits the visualization of several phenomena such as, light dispersion by diffraction gratings, diffraction order, optical fluorescence, continuous and discrete optical emission spectra, and light absorption by liquids and solids. A historical survey about the optical spectroscopy development is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vacuum pumps are very useful in physical, chemical and biological experiments. In this communication it is described the design of a compact and low cost water recirculating system employing a water-jet aspirator pump as the vacuum source. The system requires only a water pump, water-jet aspirator pump, commercial PVC water tubes and a drain connection.