979 resultados para COMET ASSAY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In this report, we propose the application of the p-iodophenol-enhanced luminol chemiluminescent technique to the determination of peroxidase (myeloperoxidase and/or platelet peroxidase) activity in blasts of minimally differentiated acute myeloblastic leukemia (AML-M0) and acute megakaryoblastic leukemia (AML-M7).Methods: the frozen blast cells from 29 patients were thawed and submitted to the optimized protocol.Results: All cases of AML-M7 and AML-M0 exhibited integrated light emission greater than 73 (10(2) mV x s), which was the arbitrary cutoff point set for the discrimination between AML and acute lymphoblastic leukemia (ALL) (mean + 3 x s.d. of ALL samples, n = 10). In addition, five out of seven cases of AML-M0 showed results above the Cutoff point.Conclusion: This highly sensitive enhanced chemiluminescent technique may be applied to discriminate between ALL and AML-M7 or AML-M1 cases, and most AML-M0 cases. It is very simple, cheap and easy to perform compared to other procedures used to measure MPO activity in AML-leukemias including AML-M7 and AML-M0.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microbiological assay applying the cylinder-plate method is described for determination of the activity of cefoxitin sodium in injectables. Using a strain of Staphylococcus epidermidis ATCC 12226 as the test organism, cefoxitin sodium was measured in concentrations ranging from 50.0 to 200.0 mu g/mL. The validation showed that the method was linear (r = 0.9998), precise (RSD 0.81%), and accurate. It was concluded that the microbiological assay is satisfactory for quantitation of cefoxitin sodium in injectables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of leukocyte alkaline phosphatasd (LAP) is used as an aid to diagnose many diseases in the laboratory. For example, it can be used to distinguish chronic myeloid leukemia (CML) from other myeloproliferative disorders (particularly myelofibrosis and polycythemia) and leukemoid reactions (LR). Traditionally, this test is performed with the use of subjective cytochemical assays that assign a score to the level of LAP. Here we present a nonsubjective, quantitative, sensitive, and inexpensive chemiluminescent technique that determines LAP based on the commercial reagent Immulite (R) (AMPPD). To validate this methodology, intact leukocytes obtained from 32 healthy subjects, nine CML patients, and nine LR patients were submitted to the optimized protocol. By measuring the light emission elicited by four concentrations of neutrophils, we were able to estimate the activity of LAP per cell (the slope of the curve obtained by linear regression). A high linear correlation was found between the chemiluminescent result (slope) and the cytochemical score. The slope for healthy individuals ranged between 0.61 and 8.49 (10(-5) mV.s/cell), with a median of 2.04 (10(-5) mV.s/cell). These results were statistically different from those of CML patients (range = 0.07-1.75, median = 0.79) and LR patients (range = 3.84-47.24, median 9.58; P < 0.05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a previous study, we showed that purified commercial esterase activity can be detected in a chemiluminescent assay based on the hydrolysis of 2-methyl-1-propenylbenzoate (MPB) to 2-methyl-1-propenol, which is subsequently oxidized by the horseradish peroxidase (HRP)-H2O2 system. The purpose of this study was to verify the applicability of this assay to human serum. The existence of an esterase activity capable of hydrolysing MPB is indicated by the fact that the MPB-scruin-HRP-H2O2 System consumes oxygen and emits light. Both signals were abolished by prior serum heat inactivation and were preserved when serum was stored at less than or equal to4 degreesC. Addition of aliesterase inhibitors, such as fluoride ion and trichlorfon or the cholinesterase inhibitor eserine, totally prevents light emission. The butyrylcholinesterase-specific substrate benzoylcholine causes a delay in both O-2 uptake and light emission, while the specific acetylcholinesterase substrate, acetyl-beta -methylcholine, had practically no effect. Purified butyrylcholinesterase, but not acetylcholinesterase, triggered light emission. The finding that butyryleholinesterase is responsible for the hydrolysis of MPB in serum should serve as the basis for the development of a specific chemiluminescent assay for this enzyme. Copyright (C) 2001 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, sensitive, and specific biodiffusion assay for the! antibacterial ceftazidime was developed using a strain of Staphylococcus epidermidis (ATCC 12228) as the test organism. Ceftazidime was measured in powder for injection at concentrations ranging from 100 to 400 mu g/mL. The calibration graph for ceftazidime was linear (r(2) = 1), and the method validation showed that it was precise (relative standard deviation = 0.415) and accurate. The results obtained by biodiffusion assay were statistically calculated by linear parallel model and by means of regression analysis and were verified using analysis of variance. It was concluded that the microbiological assay is satisfactory for in vitro quantification of the antibacterial activity of ceftazidime in pharmaceuticals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, sensitive and specific agar diffusion bioassay for the antibacterial gatifloxacin was developed using a strain of Bacillus subtilis ATCC 9372 as the test organism. Gatifloxacin could be measured in tablets and raw material at concentration ranging 4-16 mu g ml(-1). The calibration graph for gatifloxacin was linear from 4.0 to 16.0 mu g ml(-1). A prospective validation of the method demonstrated that the method was linear (r(2) = 0.9993), precise (R.S.D. = 1.14%) and accurate. The results confirmed its precision and did not differ significantly from others methods described in the literature. The validated method yielded good results in terms of the range, linearity, precision, accuracy, specificity and recovery. We concluded that the microbiological assay is satisfactory for in vitro quantification of the antibacterial activity of gatifloxacin. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validation of a microbiological assay, applying cylinder plate method for determination of the activity of lomefloxacin in coated tablets is described. Using a strain of Bacillus subtilis ATCC 9372 as the test organism, lomefloxacin was measured in concentrations ranging from 2.0 to 8.0 mu g/mL. The method validation showed that it is linear (r = 0.9999), precise (relative standard deviation 1.15%), and accurate (it measured the added quantities). The excipients did not interfere in the determination. It was concluded that the microbiological assay is satisfactory for quantitation of lomefloxacin in tablets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the current study was to develop and subsequently validate a simple, sensitive and precise reversed-phase LC method for the determination of ciprofloxacin hydrochloride in ophthalmic solution form. The chromatographic separation of ciprofloxacin hydrochloride was achieved on a Symmetry Waters C(18) column using UV detection at 275 nm. The optimized mobile phase consisted of 2.5% acetic acid solution: methanol:acetonitrile (70:15:15, v/v/v). The proposed method provided linear responses within the concentration range 1.0-6.0 mu g mL(-1) for ciprofloxacin hydrochloride. Correlation coefficient (r) for the ciprofloxacin hydrochloride was 0.9994. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 5% in all instances. No interference from any components of pharmaceutical dosage forms was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cryptococcus neoformans causes meningitis and disseminated infection in healthy individuals, but more commonly in hosts with defective immune responses. Cell-mediated immunity is an important component of the immune response to a great variety of infections, including yeast infections. We aimed to evaluate a specific lymphocyte transformation assay to Cryptococcus neoformans in order to identify immunodeficiency associated to neurocryptococcosis (NCC) as primary cause of the mycosis.Methods: Healthy volunteers, poultry growers, and HIV-seronegative patients with neurocryptococcosis were tested for cellular immune response. Cryptococcal meningitis was diagnosed by India ink staining of cerebrospinal fluid and cryptococcal antigen test (Immunomycol-Inc, SP, Brazil). Isolated peripheral blood mononuclear cells were stimulated with C. neoformans antigen, C. albicans antigen, and pokeweed mitogen. The amount of H-3-thymidine incorporated was assessed, and the results were expressed as stimulation index (SI) and log SI, sensitivity, specificity, and cut-off value (receiver operating characteristics curve). We applied unpaired Student t tests to compare data and considered significant differences for p<0.05.Results: The lymphotoxin alpha showed a low capacity with all the stimuli for classifying patients as responders and non-responders. Lymphotoxin alpha stimulated by heated-killed antigen from patients with neurocryptococcosis was not affected by TCD4+ cell count, and the intensity of response did not correlate with the clinical evolution of neurocryptococcosis.Conclusion: Response to lymphocyte transformation assay should be analyzed based on a normal range and using more than one stimulator. The use of a cut-off value to classify patients with neurocryptococcosis is inadequate. Statistical analysis should be based on the log transformation of SI. A more purified antigen for evaluating specific response to C. neoformans is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The present study aimed to evaluate the efficacy of the hyaluronic acid (HA) binding assay in the selection of motile spermatozoa with normal morphology at high magnification (8400x).Methods: A total of 16592 prepared spermatozoa were selected and classified into two groups: Group I, spermatozoa which presented their head attached to an HA substance (HA-bound sperm), and Group II, those spermatozoa that did not attach to the HA substance (HA-unbound sperm). HA-bound and HA-unbound spermatozoa were evaluated according to the following sperm forms: 1-Normal morphology: normal nucleus (smooth, symmetric and oval configuration, length: 4.75+/-2.8 mu m and width: 3.28+/-0.20 mu m, no extrusion or invagination and no vacuoles occupied more than 4% of the nuclear area) as well as acrosome, post-acrosomal lamina, neck, tail, besides not presenting a cytoplasmic droplet or cytoplasm around the head; 2-Abnormalities of nuclear form (a-Large/small; b-Wide/narrow; c-Regional disorder); 3-Abnormalities of nuclear chromatin content (a-Vacuoles: occupy >4% to 50% of the nuclear area and b-Large vacuoles: occupy >50% of the nuclear area) using a high magnification (8400x) microscopy system.Results: No significant differences were obtained with respect to sperm morphological forms and the groups HA-bound and HA-unbound. 1-Normal morphology: HA-bound 2.7% and HA-unbound 2.5% (P = 0.56). 2-Abnormalities of nuclear form: a-Large/small: HA-bound 1.6% vs. HA-unbound 1.6% (P = 0.63); b-Wide/narrow: HA-bound 3.1% vs. HA-unbound 2.7% (P = 0.13); c-Regional disorders: HA-bound 4.7% vs. HA-unbound 4.4% (P = 0.34). 3. Abnormalities of nuclear chromatin content: a-Vacuoles >4% to 50%: HA-bound 72.2% vs. HA-unbound 72.5% (P = 0.74); b-Large vacuoles: HA-bound 15.7% vs. HA-unbound 16.3% (P = 0.36).Conclusions: The findings suggest that HA binding assay has limited efficacy in selecting motile spermatozoa with normal morphology at high magnification.