910 resultados para Bond length alternation (BLA)
Resumo:
Absorbance detection in capillary electrophoresis (CE), offers an excellent mass sensitivity, but poor concentration detection limits owing to very small injection volumes (normally I to 10 nL). This aspect can be a limiting factor in the applicability of CE/UV to detect species at trace levels, particularly pesticide residues. In the present work, the optical path length of an on-column detection cell was increased through a proper connection of the column (75 mu m i.d.) to a capillary detection cell of 180 mu m optical path length in order to improve detectability. It is shown that the cell with an extended optical path length results in a significant gain in terms of signal to noise ratio. The effect of the increase in the optical path length has been evaluated for six pesticides, namely, carbendazim, thiabendazole, imazalil, procymidone triadimefon, and prochloraz. The resulting optical enhancement of the detection cell provided detection limits of ca. 0.3 mu g/mL for the studied compounds, thus enabling the residue analysis by CE/UV.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
An interferometric technique was used to determine the temperature coefficient of the optical path length (dS/dT) as a function of the temperature in several optical glasses. The temperature range was between 25degreesC and 180degreesC. The studied samples included undoped and doped oxide glasses, such as low silica calcium aluminosilicate, phosphates, borates and also chalcogenides. The oxide glasses had dS/dT between 10 X 10(-6) K-1 and 20x10(-6) K-1, while for the chalcogenides, these were around 70 x 10(-6)K(-1). The results showed that dS/dTs increased with the temperature in all samples. For samples doped with Nd the dS/dT values were found to be independent of concentration. on the other hand, for the phosphate glass doped with Cr, dS/dT increased about 5% when compared with the Nd doped one. In conclusion, the used interferometric method, which is a considerably simpler and a lower cost technique, and is a useful tool to measure dS/dT in semi-transparent glasses as a function of the composition and temperature. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: Alterations in the size of the [CAG](n) repeats of the AR gene have been described in several types tumors. The purpose of this study was to evaluate if there is an association between the AR [CAG](n) repeat alleles and the relative risk for head and neck cancer and to analyse microsatellite instability (MSI) and loss of heterozygosity (LOH) in these tumors.Design: Matched samples of blood and head and neck tumors were evaluated using two methodologies, silver-stained gels to perform the analyses of MSI and LOH, and automated analysis to confirm these results and for genotyping of the AR [CAG](n), repeat length. Sixty-nine individuals without cancer were used as a control group for both procedures. The Log-rank test was used to compare overall survival and disease-free survival curves. The Cox proportional hazards regression models were performed to determine the [CAG], repeats as an independent prognostic factor.Results: Patients with alleles <= 20 in the male group showed a correlation with lower disease-free survival (P = 0.0325) and with recurrence or metastasis (RR 2.52, CI 95%). in the female group, the allele 2 (longer allele) showed a significant lower mean of [CAG](n), repeat when compared to the control group. Microsatellite instability was detected in nine cases in both procedures. In six out of these nine cases, we observed a reduction of the AR [CAG](n) repeat length. LOH was detected in one out of 17 women informative for oral cancer in both procedures.Conclusion: These results suggest that short [CAG](n) repeat length (: 20) polymorphism is associated with poor prognosis in a subset of male patients with head and neck cancer and that AR gene microsatellite instability is uncommon in these tumors. (C) 2007 Elsevier Ltd. All rights reserved.
Resumo:
Speciation of Taenia in human stool is important because of their different clinical and epidemiological features. DNA analysis has recently become possible which overcomes the problems of differentiating human taeniid cestodes morphologically. In the present study, we evaluated PCR coupled to restriction fragment length polymorphism to differentiate Taenia solium from Taenia saginata eggs present in fecal samples from naturally infected patients. A different Dral-RFLP pattern: a two-band pattern (421 and 100 bp) for T saginata and a three-band pattern (234, 188, and 99 bp) for T solium was observed allowing the two species to be separated.. The lower detection limit of the PCR-RFLP using a non-infected fecal sample prepared with a given number of T saginata eggs was 34 eggs in 2 g stool sediment. The 521 bp mtDNA fragment was detected in 8 out of 12 Taenia sp. carriers (66.6%). of these, three showed a T solium pattern and five a T saginata pattern. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Bond failures at the acrylic teeth and denture base resin interface are still a common clinical problem in prosthodontics. The effect of methyl methacrylate (MMA) monomer on the bond strength of three types of denture base resins (Acron MC, Lucitone 550 and QC-20) to two types of acrylic teeth (Biotone and Trilux) was evaluated. Twenty specimens were produced for each denture base resin/acrylic tooth combination and were randomly divided into control (acrylic teeth received no surface treatment) and experimental groups (MMA was applied to the surface of the acrylic teeth for 180 s) and were submitted to shear tests (1 mm/mm). Data (MPa) were analyzed using three-way ANOVA/Student's test (alpha = 0.05). MMA increased the bond strength of Lucitone denture base resins and decreased the bond strength of QC-20. No difference was detected for the bond strength of Acron MC base resin after treatment with MMA. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.