930 resultados para Anterior Uveitis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Moderator Opening The early focus of contact lens wear and ocular health was on oxygen delivery. However, as we learn more about how the eye works, and investigate how the contact lens interacts with the cornea, the role of the tear film has risen in prominence. A healthy tear film is critical for normal ocular homeostasis, and abnormalities of the tear film are the primary cause of dry eye. In order to improve patient eye health and comfort during lens wear, we need to further elucidate the relationship among contact lenses, contact lens solutions, the tear film, and the corneal epithelium, and find ways to maintain homeostasis of the ocular surface. In this section, we review the latest data and opinions on this complex relationship between contact lenses and lens care solutions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eye care practitioners (ECPs) would tend to agree that wearing contact lenses increases the risk for infection, but millions of patients are still fitted with lenses every year because ECPs feel that the risk is manageable and that their patients' eye health can be protected. The Fusarium and Acanthamoeba keratitis outbreaks of years past were a wake-up call to manufacturers, ECPs, and regulatory agencies that risk cannot be managed without diligence, and that the complex relationship between contact lens materials, contact lens solutions, and compliance needs to be better understood in order to optimize the efficacy of contact lens care and improve care guidelines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ever since sodium fluorescein (‘fluorescein’ [FL]) was first used to investigate the ocular surface over a century ago, the term ‘staining’ has been taken to mean the presence of ocular surface fluorescence [1]. This term has not been necessarily taken to infer any particular mechanism of causation, and indeed, can be attributed to a variety of possible aetiologies [2]. In recent times, there has been considerable interest in a form of ocular surface fluorescence seen in association with the use of certain combinations of soft contact lenses and multipurpose solutions. The first clinical account of this phenomenon was reported by Jones et al. [3], which was followed by a more formal investigation by the same author in 2002 [4]. Jones et al described this appearance as a ‘classic solution-based toxicity reaction’. Subsequently, this appearance has come to be known as ‘solution-induced corneal staining’ or more recently by the acronym ‘SICS’ [5]. The term SICS is potentially problematic in that from a cell biology point of view, there is an inference that ‘staining’ means the entry of a dye into corneal epithelial cells. Morgan and Maldonado-Codina [2] noted there was no foundation of solid scientific literature underpinning our understanding of the true basic causative mechanisms of this phenomenon; since that time, further work has been published in this field [6] and [7] but questions still remain about the precise aetiology of this phenomenon...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This book is one in a series of seven atlases covering the ophthalmic sub-specialties: cornea, retina, glaucoma, oculoplastics, neuro-ophthalmology, uveitis and paediatrics. The author of Cornea and editor of the series is Christopher Rapuano, Attending Surgeon and Director of the Cornea Service at Wills Eye Hospital in Philadelphia, Pennsylvania, USA. In the introduction to the book, Rapuano states ‘The goal of this series is to provide an up-to-date clinical overview of the major areas of ophthalmology for students, residents and practitioners in all the healthcare professions’...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the changes occurring in the axial length, choroidal thickness and anterior biometrics of the eye during a 10 minute near task performed in downward gaze. Methods: Twenty young adult subjects (10 emmetropes and 10 myopes) participated in this study. To measure ocular biometrics in downward gaze, an optical biometer was inclined on a custom built, height and tilt adjustable table. Baseline measures were collected after each subject performed a distance primary gaze control task for 10 mins, to provide wash-out period for prior visual tasks before each of three different accommodation/gaze conditions. These other three conditions included a near task (2.5 D) in primary gaze, and a near (2.5 D) and a far (0 D) accommodative task in downward gaze (25°), all for 10 mins duration. Immediately after, and then 5 and 10 mins from the commencement of each trial, measurements of ocular biometrics (e.g. anterior biometrics, axial length, choroidal thickness and retinal thickness) were obtained. Results: Axial length increased with accommodation and was significantly greater for downward gaze with accommodation (mean change ± SD 23 ± 13 µm at 10 mins) compared to primary gaze with accommodation (mean change 8 ± 15 µm at 10 mins) (p < 0.05). A small amount of choroidal thinning was also found during accommodation that was statistically significant in downward gaze (13 ± 14 µm at 10 mins, p < 0.05). Accommodation in downward gaze also caused greater changes in anterior chamber depth and lens thickness compared to accommodation in primary gaze. Conclusion: Axial length, choroidal thickness and anterior eye biometrics change significantly during accommodation in downward gaze as a function of time. These changes appear to be due to the combined influence of biomechanical factors (i.e. extraocular muscle forces, ciliary muscle contraction) associated with near tasks in downward gaze.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose The presence of a lymphocytic infiltration in autonomic ganglia and an increased prevalence of autoantibodies and iritis in diabetic patients with autonomic neuropathy suggests a role for autoimmune mechanisms in the development of diabetic and perhaps somatic neuropathy. Corneal Langerhans cells are antigenpresenting cells which can be identified in corneal immunologic conditions using in-vivo confocal microscopy. The aim of this study was to assess the presence and density of Langerhans cells (LCs) in Bowman’s layer of the cornea in diabetic patients with varying degrees of neuropathy compared to healthy control subjects. Method 128 diabetic patients aged 58±1 years with differing severity of neuropathy (NDS – 4.7±0.28) and 26 control subjects aged 53±3 years were examined with in-vivo corneal confocal microscopy to quantify the density of “Langerhans cells” (LCs). Results LCs were observed more often in diabetic patients (73.8%) compared to control subjects (46.1%), P = 0.001. The LC density (number/mm2) was also significantly increased in diabetic patients (17.73±1.45) compared to control subjects (6.94±1.58, P = 0.001). There was a significant correlation between the density of LCs with age (r = 0.162, P = 0.047) and severity of neuropathy assessed by NDS (r =−0.202, P = 0.02). Conclusions In vivo corneal confocal microscopy enables quantification of Langerhans cells in Bowman’s layer of the cornea. There is a relationship between density of LCs and the degree of nerve damage. Corneal confocal microscopy could be a valuable tool to establish the role of immune mediated corneal nerve damage and provide insights into the pathogenesis of diabetic neuropathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Contrary to what many practitioners believe, current generation contact lenses are easy to fit, are well tolerated, provide superior vision, are physiologically compatible with the anterior ocular structures, cause few serious complications and are cost effective. These factors will be explored with examples of advancements that have occurred in contact lens practice over the past two decades. Consideration will also be given to the role of optometrists, the contact lens industry and educational institutions in promoting contact lenses as an alternative form of vision correction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To assess confocal microscopy repeatability (ConfoScan3, Nidek, Italy) when assessing the morphology of the limbus, midperipheral and central cornea. Method The central, mid-peripheral and limbal cornea (temporal and nasal) of the right eye of 8 subjects were examined with a ConfoScan3 in two different visits, at least six months apart. Bland-Altman repeatability was measured for 29 parameters: basal cell density and size, anterior and posterior keratocyte densities (AKD/PKD), endothelial cell density, polymegethism, pleomorphism, mean area and sides of endothelial cells - in the five different corneal areas examined. Results As a percentage of the mean absolute values, repeatability of 0–10% was classified as “excellent”, between 10–30% as “acceptable” and over 30% as “poor”. Repeatability was excellent for 14% of parameters and acceptable for 52% of parameters. The number of endothelial cell sides in the central cornea demonstrated the best repeatability (2.0%) whilst mid-temporal PKD showed the poorest repeatability (53.7%). Conclusions Confocal microscopy is at least an adequately repeatablemethodof evaluating the various corneal layers at different locations. Our dataset supports the ongoing use of the technique in research and clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Has the 1998 prediction of a well-known contact lens researcher – that rigid contact lenses will be obsolete by the year 2010 – come to fruition? This Eulogy to RGPs will demonstrate why it has. A recent survey of international contact lens prescribing trends shows that rigid lenses constituted less than 5% of all contact lenses prescribed in 16 out of 27 nations surveyed. This compares with rigid lenses representing 100% of all lenses prescribed 1965 and about 40% in 1990). With the wide range of sophisticated soft lens materials available today, including super-permeable silicone hydrogels, and designs capable of correcting astigmatism and presbyopia, there is now no need to fit cosmetic patients with rigid lenses, with the associated intractable problems of rigid lens-induced ptosis, 3 and 9 o’clock, staining, lens binding, corneal warpage and adaptation discomfort. Orthokeratology is largely a fringe application of marginal efficacy, and the notion that rigid lenses arrest myopia progression is flawed. That last bastion of rigid lens practice – fitting patients with severely distorted corneas as in keratoconus – is about to crumble in view of a number of demonstrations by independent research groups of the efficacy of custom-designed wavefront-corrected soft contact lenses for the correction of keratoconus. It is concluded that rigid contact lenses now have no place in modern contact lens practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxygen has been the “holy grail” of contact lens wear for over 100 years, but it is just one piece of a complex jigsaw puzzle. Clearly, high oxygen transmissibility (Dk/t) silicone hydrogel lenses meet the oxygen needs of the cornea. The Dk/t of these lenses is over 75 Dk units, which is far above that of the “best” hydrogel lenses (30 Dk units). Clinical trials have failed to reveal any hypoxic problemswith silicone hydrogel lenses. Thus, conditions such as epithelial microcysts, limbal redness, hypoxic staining, stromal neovascularisation, oedema and endothelial polymegethism do not occur with these lenses. My view is that – looking at the “big picture” – we are far better off now that we have silicone hydrogel lenses.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New technologies for examination of the anterior eye in contact lens practice don’t appear to have taken a huge leap in the past decade however there a several novel adaptations of existing technology worthy of note. In other areas of health we have self-diagnosis via smartphone or other gadgets adapted as medical devices. In practice and research in vitro and in vivo new adaptive technologies have expanded our capabilities in assessing the anterior eye, in particular corneal and conjunctival confocal microscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was undertaken to investigate any relationship between sensory features and neck pain in female office workers using quantitative sensory measures to better understand neck pain in this group. Office workers who used a visual display monitor for more than four hours per day with varying levels of neck pain and disability were eligible for inclusion. There were 85 participants categorized according to their scores on the neck disability index (NDI): 33 with no pain (NDI < 8); 38 with mild levels of pain and disability (NDI 9–29); 14 with moderate levels of pain (NDI ⩾ 30). A fourth group of women without neck pain (n = 22) who did not work formed the control group. Measures included: thermal pain thresholds over the posterior cervical spine; pressure pain thresholds over the posterior neck, trapezius, levator scapulae and tibialis anterior muscles, and the median nerve trunk; sensitivity to vibrotactile stimulus over areas of the hand innervated by the median, ulnar and radial nerves; sympathetic vasoconstrictor response. All tests were conducted bilaterally. ANCOVA models were used to determine group differences between the means for each sensory measure. Office workers with greater self-reported neck pain demonstrated hyperalgesia to thermal stimuli over the neck, hyperalgesia to pressure stimulation over several sites tested; hypoaesthesia to vibration stimulation but no changes in the sympathetic vasoconstrictor response. There is evidence of multiple peripheral nerve dysfunction with widespread sensitivity most likely due to altered central nociceptive processing initiated and sustained by nociceptive input from the periphery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study determined differences between computer workers with varying levels of neck pain in terms of work stressors, employee strain, electromyography (EMG) amplitude and heart rate response to various tasks. Participants included 85 workers (33, no pain; 38, mild pain; 14, moderate pain) and 22 non-working controls. Work stressors evaluated were job demands, decision authority, and social support. Heart rate was recorded during three tasks: copy-typing, typing with superimposed stress and a colour word task. Measures included electromyography signals from the sternocleidomastoid (SCM), anterior scalene (AS), cervical extensor (CE) and upper trapezius (UT) muscles bilaterally. Results showed no difference between groups in work stressors or employee strain measures. Workers with and without pain had higher measured levels of EMG amplitude in SCM, AS and CE muscles during the tasks than controls (all P < 0.02). In workers with neck pain, the UT had difficulty in switching off on completion of tasks compared with controls and workers without pain. There was an increase in heart rate, perceived tension and pain and decrease in accuracy for all groups during the stressful tasks with symptomatic workers producing more typing errors than controls and workers without pain. These findings suggest an altered muscle recruitment pattern in the neck flexor and extensor muscles. Whether this is a consequence or source of the musculoskeletal disorder cannot be determined from this study. It is possible that workers currently without symptoms may be at risk of developing a musculoskeletal disorder.