962 resultados para 3D Computer Graphics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This book was produced in the scope of a research project entitled “Navigating with ‘Magalhães’: Study on the Impact of Digital Media in Schoolchildren”. This study was conducted between May 2010 and May 2013 at the Communication and Society Research Centre, University of Minho, Portugal and it was funded by the Portuguese Foundation for Science and Technology (PTDC/CCI-COM/101381/2008).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

(Excerto) In times past, learning to read, write and do arithmetic was to get on course to earn the “writ of emancipation” in society. These skills are still essential today, but are not enough to live in society. Reading and critically understanding the world we live in, with all its complexity, difficulties and challenges, require not only other skills (learning to search for and validate information, reading with new codes and grammar, etc) but, to a certain extent, also metaskills, matrixes and mechanisms that are transversal to the different and new literacies, are necessary. They are needed not just to interpret but equally to communicate and participate in the little worlds that make up our everyday activities as well as, in a broader sense, in the world of the polis, which today is a global world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This book was produced in the scope of a research project entitled “Navigating with ‘Magalhães’: Study on the Impact of Digital Media in Schoolchildren”. This study was conducted between May 2010 and May 2013 at the Communication and Society Research Centre, University of Minho, Portugal and it was funded by the Portuguese Foundation for Science and Technology (PTDC/CCI-COM/101381/2008). As we shall explain in more detail later in this book, the main objective of that research project was to analyse the impact of the Portuguese government programme named ´e-escolinha´ launched in 2008 within the Technological Plan for Education. This Plan responds to the principles of the Lisbon Strategy signed in 2000 and rereleased in the Spring European Council of 2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de estágio de mestrado em Arqueologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de estágio de mestrado em Média Interativos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: O ecocardiograma tridimensional em tempo real (ECO 3D) e a tomografia computadorizada ultra-rápida (CT) são dois novos métodos de análise da fração de ejeção e dos volumes do VE. OBJETIVO: Comparar as medidas da FEVE e dos volumes do VE aferidos pelo ECO 3D e pela CT ultra-rápida. MÉTODOS: Foram estudados pelo ECO 3D e pela CT ultra-rápida de 64 cortes, 39 pacientes consecutivos (27 homens, média etária de 57±12 anos). Foram analisados: FEVE e volumes do VE. Análise estatística: coeficiente de correlação (r: Pearson), teste de Bland & Altman, teste de regressão linear, 95 % IC, p<0,05. RESULTADOS: Medidas do ECO 3D: a FEVE variou de 56,1 a 78,6 (65,5±5,58)%; volume diastólico final variou de 49,6 a 178,2 (87±27,8)ml; volume sistólico final variou de 11,4 a 78 (33,1±13,6)ml. Medidas da CT: a FEVE variou de 53 a 86 (67,8±7,78)%; volume diastólico final variou de 51 a 186 (106,5±30,3) ml; volume sistólico final variou de 7 a 72 (35,5±13,4)ml. As correlações entre ECO 3D e CT foram: FEVE (r: 0,7888, p<0,0001, 95% IC 0,6301 a 0,8843); volume diastólico final (r: 0,7695, p<0,0001, 95% IC 0,5995 a 0,8730); volume sistólico final (r: 0,8119, p<0,0001, 95% IC 0,6673 a 0,8975). CONCLUSÃO: Nesta série, foi observada boa correlação entre as medidas da FEVE e entre os volumes ventriculares aferidos pelo ECO3D e pela CT ultra-rápida de 64 cortes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is a study of a state of the art implementation of a new computer integrated testing (CIT) facility within a company that designs and manufactures transport refrigeration systems. The aim was to use state of the art hardware, software and planning procedures in the design and implementation of three CIT systems. Typical CIT system components include data acquisition (DAQ) equipment, application and analysis software, communication devices, computer-based instrumentation and computer technology. It is shown that the introduction of computer technology into the area of testing can have a major effect on such issues as efficiency, flexibility, data accuracy, test quality, data integrity and much more. Findings reaffirm how the overall area of computer integration continues to benefit any organisation, but with more recent advances in computer technology, communication methods and software capabilities, less expensive more sophisticated test solutions are now possible. This allows more organisations to benefit from the many advantages associated with CIT. Examples of computer integration test set-ups and the benefits associated with computer integration have been discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A terapia de ressincronização cardíaca consiste em tratamento promissor para pacientes com insuficiência cardíaca grave, porém cerca de 30% dos pacientes não apresentam melhora clínica com este tratamento. Por outro lado, aproximadamente 10% dos pacientes submetidos a essa terapia podem apresentar hiper resposta, e a ecocardiografia tridimensional pode oferecer uma opção interessante para a seleção e avaliação de tratamento desses pacientes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: A ecocardiografia consiste em método muito útil para seleção e avaliação de resposta à terapia de ressincronização cardíaca (TRC). O eco 3D já tem seu papel estabelecido na avaliação dos volumes ventriculares e fração de ejeção ventricular esquerda (FEVE) com excelente correlação de resultados quando comparado à RNM. OBJETIVO: Comparar a avaliação dos volumes ventriculares (VDVE, VSVE), FEVE e massa do VE antes e após a TRC pela ecocardiografia bi (Eco 2D) e tridimensional (Eco 3D). MÉTODOS: Foram avaliados 24 pacientes com IC CFIII ou IV (NYHA), ritmo sinusal QRS > 150 ms, em vigência de terapêutica otimizada para IC submetidos a TRC. Foram realizados eletrocardiograma (ECG), avaliação clínica, Eco 2D e 3D antes, três e seis meses após a TRC. A comparação entre as técnicas foi realizada utilizando-se a correlação de Pearson (r). RESULTADOS: No momento basal, a correlação entre os métodos foi de 0,96 para avaliação do VDVE, 0,95 para avaliação do VSVE, 0,87 para FEVE, e 0,72 para massa do VE. Após três meses da TRC, a correlação entre os métodos para análise do VDVE foi de 0,96, 0,95 para VSVE, 0,95 para FEVE, e 0,77 para massa do VE. Após seis meses da TRC, a correlação entre o Eco 2D e 3D para análise do VDVE foi de 0,98, 0,91 para VSVE, 0,96 para FEVE, e 0,85 para massa do VE. CONCLUSÃO: Neste estudo foi observada redução dos VDVE,VSVE, além de melhora da FEVE após a TRC. Houve excelente correlação entre o Eco 2D e o 3D para avaliação dos volumes ventriculares e FEVE, e boa correlação entre os métodos para avaliação da massa ventricular esquerda antes e após a TRC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: Remodelamento ventricular esquerdo (RVE) após IAM caracteriza fator de mau prognóstico. Há pouca informação na literatura sobre o RVE analisado com ecocardiografia tridimensional (ECO 3D) OBJETIVO: Analisar com ECO 3D as modificações geométricas e volumétricas do ventrículo esquerdo (VE) seis meses após IAM em pacientes submetidos a tratamento primário percutâneo. MÉTODOS: Estudo prospectivo com ECO 3D de 21 indivíduos (16 homens, 56 ± 12 anos), acometidos por IAM com elevação do segmento ST. Foi feita a análise morfofuncional (VE) com ECO 3D (volumes, FEVE, índice de esfericidade 3D) até sete dias e seis meses após o IAM. RVE foi considerado para aumento > 15% do volume diastólico final do VE (VDFVE) após seis meses do IAM, comparado ao VDFVE até sete dias do evento. RESULTADOS: Oito (38%) pacientes apresentaram RVE. Medidas ecocardiográficas (n = 21 pacientes): I- até sete dias do IAM: 1- VDFVE: 92,3 ± 22,3 mL; 2- FEVE: 0,51 ± 0,01; 3- índice de esfericidade: 0,38 ± 0,05; II- após seis meses: 1- VDFVE: 107,3 ± 26,8 mL; 2- FEVE: 0,59 ± 0,01; 3- índice de esfericidade: 0,31 ± 0,05. Coeficiente de correlação (r) entre índice de esfericidade até sete dias do IAM e VDFVE aos seis meses (n = 8) após o IAM: r: 0,74, p = 0,0007; (r) entre índice de esfericidade após seis meses do IAM e VDFVE aos seis meses do IAM: r: 0,85, p < 0,0001. CONCLUSÃO: Nesta série, foi observado RVE em 38% dos pacientes seis meses após IAM. O índice de esfericidade tridimensional foi associado à ocorrência de RVE.