977 resultados para solid-phase microextraction (SPME)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study investigated the levels of plasticizer endocrine disruptors (diethyl phthalate, dibutyl phthalate, and bisphenol A) in drinking water at Paraíba do Sul River region and release of these compounds from bottled water. An analytical method employing solid phase extraction and GC/MS was optimized and validated. The results showed that the method is selective, linear (r² > 0.99), precise (RSD <12%), accurate (recoveries between 62 and 105%), sensitive and robust. Applying the method, the presence of all studied pollutants in drinking water was observed for the three sampled plasticizers. These plasticizers were not found in mineral bottled water, before or after storage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes selective molecularly imprinted solid-phase extraction of ttMA from urine samples followed by derivatization and analysis by gas chromatography/mass spectrometry (GC/MS). The analytical calibration curve ranged from 0.3 to 7.0 mg L-1 (r = 0.999) and the limit of quantitation (LOQ) was 0.3 mg L-1. The method was applied for the determination of ttMA in urine samples from smokers and concentrations detected ranged from < LOQ to 1.64 mg L-1. Thus, the proposed method proved adequate for the determination of urinary ttMA in the biomonitoring of occupational exposure to low levels of benzene.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simultaneous solid phase extraction procedure for enrichment of Cu(II), Cd(II) and Mn(II) has been developed. The method is based on adsorption of Cu(II), Cd(II) and Mn(II) ions on polyethylene glycol-silica gel pre-conditioned with acetate buffer (pH 5.5). The adsorbed metal ions are eluted with nitric acid (1 mol L -1) and determined by flame atomic absorption spectrometry. The calibration graph was linear in the range of 2-140 ng mL-1 for Cu(II), 1-40 ng mL-1 for Cd(II) and 4-100 ng mL-1 for Mn(II). The limits of detection were 0.66, 0.33 and 1.20 ng mL-1 for Cu(II), Cd(II) and Mn(II), respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analytical methods were developed and validated to determine residues of veterinary drugs in buffalo milk and meat, using the QuEChERS method and gas chromatography-mass spectrometry. Both milk and meat, at 2 g of sample, 4 mL of acetonitrile, 0.8 g of MgSO4 and 0.2 g of NaCl, were used in the liquid-liquid partition, whereas 50 mg of C18, 50 mg of PSA and 150 mg of MgSO4 were employed in the dispersive solid-phase extraction (d-SPE). The methods showed sensitivity, precision and accuracy. The quantitation limits were in agreement with the maximum residue limit established by the Codex Alimentarius, FAO and WHO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This is an overview of LC-MS techniques applied for macrolide determination in food, including sample preparation and method validation, as well as the policies adopted by international agencies regarding their presence in food. Techniques for the analysis of macrolides in food normally include solid phase or liquid-liquid extraction followed by HPLC. UHPLC presents advantages in running time, detectability and solvent consumption. Triple-quadrupoles are the most common analyzers in instruments used for the determination of contaminants in food, but time-of-flight and ion-trap spectrometers have been successfully applied for analyses focusing on the investigation of structural formula or the presence of degradation products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new solid phase extraction (SPE) method has been developed for the selective separation and preconcentration of Cu (II) ions in food and water samples prior to its flame atomic absorption spectrometry determination. The method is based on the adsorption of the Cu(II) - 2-{[4-Amino-3-(4-methylphenyl-5-oxo-4,5-dihydro-1H-1,2,4-triazol-1-yl]acetyl}-N-phenyl hydrazinecarbothioamide complex on Amberlite XAD-8 resin. The metal complex retained on the resin was eluted with 7.5 mL of 2.0 mol L-1 HCl in acetone. The optimum conditions for the SPE of Cu(II) ions were investigated, and the method was subsequently applied to sea water, stream water, rice, tea, and tobacco samples for the determination of Cu(II) levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chemical imprinting technology has been widely used as a valuable tool in selective recognition of a given target analyte (molecule or metal ion), yielding a notable advance in the development of new analytical protocols. Since their discovery, molecularly imprinted polymers (MIPs) have been extensively studied with excellent reviews published. However, studies involving ion imprinted polymers (IIPs), in which metal ions are recognized in the presence of closely related inorganic ions, remain scarce. Thus, this review involved a survey of different synthetic approaches for preparing ion imprinted adsorbents and their application for the development of solid phase extraction methods, metal ion sensors (electrodes and optodes) and selective membranes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we describe the synthesis of an ion imprinted polymer (IIP) by homogeneous polymerization and its use in solid-phase to extract and preconcentrate zinc ions. Under optimal conditions (pH 5.0, preconcentration flow rate of 12.0 mL min-1, and eluted with 1.0 mol L-1 HNO3) this procedure allows the determination of zinc with an enrichment factor of 10.2, and with limits of detection and quantification of 1.5 and 5.0 µg L-1, respectively. The accuracy of our results was confirmed by analysis of tap water and certified reference materials: NIST 1570a (Spinach leaves) and NIST 1515 (Apple leaves).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method was developed for the analysis of 31 pharmaceutical compounds in Lisbon's drinking water system, using solid-phase extraction (SPE) and ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS). The method was validated through estimation of the linearity range, method detection and quantification limits, matrix effects, precision and accuracy. The method detection and quantification limit ranges were 0.009-10 and 0.03-33 ng/L, respectively. Analytes were quantified in water samples collected from the EPAL (Empresa Portuguesa das Águas Livres S.A.) supply system. Carbamazepine, atenolol, sulfadiazine, sulfamethazine, sulfapyridine, sulfamethoxazole, acetaminophen, caffeine and erythromycin were quantified in the analysed samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Extraction/concentration is a crucial step for the analysis of organic compounds at trace level concentrations and dispersed in complex matrices. Solid-phase extraction (SPE) is one of the techniques used for this purpose. In this work, a low cost apparatus for SPE was developed that uses nitrogen under positive pressure and ensures the maintenance of the sample flow, while also allows the simultaneous extraction of different samples without cross-contamination and sample contact with plastic materials. For the system set up, easily accessible materials were used such as hypodermic needles, stainless steel tubes, rubber stoppers, and 3-way valves from serum delivery apparatus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure was developed for determination of 5 sedatives and 14 β-blockers in swine kidney and subsequent analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Three different procedures for extraction were tested, evaluated through recovery studies. The procedure using acetonitrile for extraction and cleanup with freezing at low temperature and dispersive solid phase extraction using 500 mg celite® 545 before the concentration step presented the better results. The dried samples were redissolved with methanol and analyzed using a LC-MS/MS system with electrospray ionization (ESI) operating in positive MRM mode. The recovery values for this procedure were in the 75-88% range. The robustness of the method was tested against small variations. The method was used to analyze carazolol, azaperone and azaperol in collaborative assay, obtaining results close to designed value.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

C18 chemically bonded sorbents have been the main materials used in solid phase extraction (SPE). However, due their high hydrophobicity some hydrophobic solutes are strongly retained leading to the consumption of larger quantities of organic solvent for efficient recoveries. This work presents a sorbent with lower hydrophobicity but similar selectivity to the C18 sorbent, prepared by thermal immobilization of poly(dimethylsiloxane-co-alkylmethylsiloxane) (PDAS) on silica. PDAS has organic chains with methyl groups alternating with octadecyl or hexadecyl groups in its monomeric unities. For the Si(PDAS) sorbent presented, the polymeric layer was physically adsorbed on the silica surface with 12% carbon load. Although the coating of silica with the polymeric layer was incomplete, the PDAS provided better protection for the silica surface groups, promoting mostly hydrophobic interactions between analytes and the sorbent. Sorption isotherm studies revealed that the retention of hydrophobic solutes on Si(PDAS) was less intense than on conventional sorbents, confirming the lower hydrophobicity of the lab-made sorbent. Additional advantages of Si(PDAS) include simplicity and low cost of preparation, making this material a potential sorbent for the analysis of highly hydrophobic solutes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, cantilever-enhanced photoacoustic spectroscopy (CEPAS) was applied in different drug detection schemes. The study was divided into two different applications: trace detection of vaporized drugs and drug precursors in the gas-phase, and detection of cocaine abuse in hair. The main focus, however, was the study of hair samples. In the gas-phase, methyl benzoate, a hydrolysis product of cocaine hydrochloride, and benzyl methyl ketone (BMK), a precursor of amphetamine and methamphetamine were investigated. In the solid-phase, hair samples from cocaine overdose patients were measured and compared to a drug-free reference group. As hair consists mostly of long fibrous proteins generally called keratin, proteins from fingernails and saliva were also studied for comparison. Different measurement setups were applied in this study. Gas measurements were carried out using quantum cascade lasers (QLC) as a source in the photoacoustic detection. Also, an external cavity (EC) design was used for a broader tuning range. Detection limits of 3.4 particles per billion (ppb) for methyl benzoate and 26 ppb for BMK in 0.9 s were achieved with the EC-QCL PAS setup. The achieved detection limits are sufficient for realistic drug detection applications. The measurements from drug overdose patients were carried out using Fourier transform infrared (FTIR) PAS. The drug-containing hair samples and drug-free samples were both measured with the FTIR-PAS setup, and the measured spectra were analyzed statistically with principal component analysis (PCA). The two groups were separated by their spectra with PCA and proper spectral pre-processing. To improve the method, ECQCL measurements of the hair samples, and studies using photoacoustic microsampling techniques, were performed. High quality, high-resolution spectra with a broad tuning range were recorded from a single hair fiber. This broad tuning range of an EC-QCL has not previously been used in the photoacoustic spectroscopy of solids. However, no drug detection studies were performed with the EC-QCL solid-phase setup.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thoroughbred fillies were divided into three groups according to age: group 1, 7 fillies aged 1 to 2 years (G1) starting the training program; group 2, 9 fillies aged 2 to 3 years (G2) in a full training program; group 3, 8 older fillies 3 to 4 years of age (G3) training and racing. Blood samples were collected weekly from July to December. Cortisol was quantified using a solid phase DPC kit. The intra- and interassay coefficients of variation were 12.5% and 15.65% and sensitivity was 1.9 ± 0.2 nmol/l. The semester average of cortisol levels varied between groups: G1 = 148.8 ± 6.7, G2 = 125.7 ± 5.8, G3 = 101.1 ± 5.4 nmol/l, with G3 differing statistically from the other groups. The lower cortisol levels observed in the older fillies lead us to propose that the stress stimulus, when maintained over a long period of time, may become chronic and result in a reduction of hypophyseal corticotropin-releasing hormone receptors. The secretion of endogenous opioids may also lead to low serum cortisol levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Eight Panthera onca (Po), 13 Felis concolor (Fc), 7 Felis yagouaroundi (Fy), 7 Felis tigrina (Ft) and 5 Felis pardalis (Fp) specimens from São Paulo State zoos were used. All animals were restrained with darts containing 10 mg/kg ketamine and 1 mg/kg xylazine. Venous blood samples were collected as soon as possible (within 15-20 min) and serum was frozen until the time for cortisol quantification. Cortisol was determined using a solid phase radioimmunoassay with an intra-assay coefficient of 8.51%. Data were analyzed statistically by the Kruskal-Wallis test, followed by Dunn's multiple comparisons test, and the one-sample t-test, with the level of significance set at P<0.05. Data are reported as means ± SEM. Cortisol levels differed among the captive felines: Po = 166 ± 33a, Fc = 670 ± 118b, Fy = 480 ± 83b, Ft = 237 ± 42ab, Fp = 97 ± 12a nmol/l (values followed by different superscript letters were significantly different (P<0.001)). Since most of the veterinary procedures on these species involve chemical restraint, these results show the necessity of preventive measures in order to minimize the effect of restraint stress on more susceptible species