845 resultados para objective-based coordination


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this is study is to point inter-institutional partnerships in Information Science formed through co-authorship network. More specifically, we calculate indicators of centrality degree, betweenness centrality and closeness centrality, and analyze the relationships between the grades attributed by CAPES - Coordination for the Improvement of Higher Education Personnel - to the institutions and the indicators on the network, checking whether there is proximity and similarity between network indicators and CAPES's grades. Our corpus consisted of all articles published in the four journals in the field of Information Science in Brazil, with regular publications, based in SciVerse Scopus, for the 2010- 2012 period. We retrieved 237 articles, 58 co-authored, with 117 participant institutions. We conducted the analysis of relations between institutions with greater grades by CAPES and the network through centrality indicators. It was concluded that these network indicators and CAPES concepts are articulated, harmonizing these two categories of indicators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective. To determine the effects of different aging methods on the degradation and flexural strength of yttria-stabilized tetragonal zirconia (Y-TZP)Methods. Sixty disc-shaped specimens (0, 12 mm; thickness, 1.6 mm) of zirconia (Vita InCeram 2000 YZ Cubes, VITA Zahnfabrik) were prepared (ISO 6872) and randomly divided into five groups, according to the aging procedures (n=10): (C) control; (M) mechanical cycling (15,000,000 cycles/3.8 Hz/200N); (T) thermal cycling (6,000 cycles/5-55 degrees C/30 s); (TM) thermomechanical cycling (1,200,000 cycles/3.8 Hz/200N with temperature range from 5 C to 55 C for 60s each); (AUT) 12h in autoclave at 134 degrees C/2 bars; and (STO) storage in distilled water (37 degrees C/400 days). After the aging procedures, the monoclinic phase percentages were evaluated by X-ray diffraction (XRD), and topographic surface analysis was performed by 3D profilometry. The specimens were then subjected to biaxial flexure testing (1 mm/min, load 100 kgf, in water). The biaxial flexural strength data (MPa) were analyzed by 1-way ANOVA and Tukey's test (alpha = 0.05). The data for monoclinic phase percentage and profilometry (Ra) were analyzed by Kruskal-Wallis and Dunn's tests.Results. ANOVA revealed that flexural strength was affected by the aging procedures (p = 0.002). The M (781.6 MPa) and TM (771.3 MPa) groups presented lower values of flexural strength than did C (955 MPa), AUT (955.8 MPa), T (960.8 MPa) and STO (910.4 MPa). The monoclinic phase percentage was significantly higher only for STO (12.22%) and AUT (29.97%) when compared with that of the control group (Kruskal-Wallis test, p = 0.004). In addition, the surface roughnesses were similar among the groups (p = 0.165).Signcance. Water storage for 400 days and autoclave aging procedures induced higher phase transformation from tetragonal to monoclinic; however, they did not affect the flexural strength of Y-TZP ceramic, which decreased only after mechanical and thermomechanical cycling. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Criteria for metabolic syndrome (MS) differ particularly regarding the definition of central obesity and consequently, there could be differences in the assessment of cardiovascular risk. We estimated the prevalence of metabolic syndrome, compared the agreement of the World Health Organization (WHO) criteria with the standard and a modified National Cholesterol Education Program (NCEP) criterion and investigated whether additional factors were associated with the diagnosis of the syndrome in a Japanese descendant population.Methods: In this cross-sectional, population-based survey, 1166 Japanese-Brazilians (533 men, 633 women) aged 57.4 +/- 12.4 years with mean body mass index (BMI) and waist of 25.2 +/- 4.0 kg/m(2) and 84.5 +/- 10.6 cm, respectively, were included. McNemar and kappa statistics were used to assess the concordance between WHO criteria with the standard and a modified NCEP criteria (waist of 90 and 80 cm, for men and women, respectively). in logistic regression analysis, a number of metabolic variables and albumin-to-creatinine ratio were included to test independent associations with metabolic syndrome defined by the modified NCEP criteria.Results: According to WHO, 55.4% (95% Cl 52.5-58.2%) of the subjects had MS and to NCEP 47.4% (95% Cl 44.6-50.0%). WHO criterion detected 48.3% of central obese subjects while NCEP only 14.0%. Kappa statistics showed a good strength of agreement (k = 0.67, p < 0.01) between WHO and NCEP standard definitions of MS. Using the modified NCEP criterion for Asians, more subjects with metabolic syndrome were identified (58%) and agreement with WHO was improved (k = 0.72, p < 0.001). However, similar Framingham risk scores were attributed to the subsets of subjects classified by any of the three criteria. Areas under the receiver operating characteristic curves, obtained for the modified waist values to diagnose metabolic syndrome according to WHO, were > 0.80 and corresponded, respectively, to sensitivity and specificity of 63 and 83% for men and 77 and 72% for women. In final logistic regression model, age, male sex, BMI and homeostasis model assessment-insulin resistance but not with albumin-to-creatinine ratio (ACR) were independently associated with the syndrome.Conclusions: High prevalence of MS, independent of the criterion considered, was found in this Japanese-Brazilian population. The replacement of waist cutoff by those proposed by WHO for Asians lead to this diagnosis in a higher number of subjects with elevated cardiovascular risk. Our data did not support that ACR should be included in the classical definition of MS in Japanese descendants as previously suggested by WHO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To investigate the effects of elastic tubing training compared with conventional resistance training on the improvement of functional exercise capacity, muscle strength, fat-free mass, and systemic inflammation in patients with chronic obstructive pulmonary disease.Design: A prospective, randomized, eight-week clinical trial.Setting: The study was conducted in a university-based, outpatient, physical therapy clinic.Subjects: A total of 49 patients with moderate chronic obstructive pulmonary disease.Interventions: Participants were randomly assigned to perform elastic tubing training or conventional resistance training three times per week for eight weeks.Main measures: The primary outcome measure was functional exercise capacity. The secondary outcome measures were peripheral muscle strength, health-related quality of life assessed by the Chronic Respiratory Disease Questionnaire (CRDQ), fat-free mass, and cytokine profile.Results: After eight weeks, the mean distance covered during six minutes increased by 73 meters (69) in the elastic tubing group and by 42 meters (+/- 59) in the conventional group (p < 0.05). The muscle strength and quality of life improved in both groups (P < 0.05), with no significant differences between the groups. There was a trend toward an improved fat-free mass in both groups (P = 0.05). After the first and last sessions, there was an increase in interleukin 1 (IL-1) and interleukin 10 (IL-10) in both groups, while tumour necrosis factor alpha (TNF-) was stimulated only in the conventional training group.Conclusion: Elastic tubing training had a greater effect on functional exercise capacity than conventional resistance training. Both interventions were equally effective in improving muscle strength and quality of life.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Several cements are used as biomaterials. Biopolymers such as chitosan and collagen exhibit excellent biocompatibility and can be used in the remodeling of bone tissue. The cement must have high mechanical strength and compatibility with original tissue. In this context, the objective of this study was to extract, characterize and cross-link collagen from bovine tendon, forlater associate it with chitosan and calcium phosphate to obtain cements for bone regeneration. Glutaraldehyde was used as cross-linker in 0.1, 0.5, 1.0 and 10% concentration. Infrared analysis confirmed the presence of functional groups characteristic of collagen, whereas the capacity of water absorption decreased with the increasing of cross-linking degree. Denaturation temperatures of collagen samples were obtained by Differential Scanning Calorimetry and Scanning Electron Microscopy showed the fiber structure characteristics of collagen, which were more organized for high degree of cross-linking samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MTA is composed of various metal oxides, calcium oxide and bismuth. It has good biological properties and is indicated in cases of endodontic complications. Several commercial formulations are available and further studies are necessary to evaluate these materials. Objective: To evaluate pH and calcium releasing of MTA Fillapex® compared with gray and white MTA. Material and methods: Gray and white MTA (Angelus) and MTA Fillapex® (Angelus) were manipulated and placed into polyethylene tubes and immersed in distilled water. The pH of these solutions was measured at 24 hours, 7 days and 14 days. Simultaneously, at these same aforementioned periods, these materials' calcium releasing was quantified, through atomic absorption spectrophotometry. The results were submitted to ANOVA, with level of significance at 5%. Results: Concerning to pH, the materials present similar behaviors among each other at 24 hours (p > 0.05). At 7 and 14 days, MTA Fillapex® provided significantly lower pH values than the other materials (p < 0.05). Regarding to calcium releasing, at 24 hours and 7 days, MTA Fillapex® provided lower releasing than the other materials (p < 0.05). After 14 days, differences were found between MTA Fillapex® and gray MTA (p < 0.05). Conclusion: All materials showed alkaline pH and calcium releasing, with significantly lower values for MTA Fillapex® sealer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Alkalinization potential is a fundamental property of endodontic epoxy-based cements containing calcium hydroxide. Studies have shown discrepant pH results for same materials at different evaluation periods. A possible reason accounting for these differences may be the assessment procedures. Objective: To evaluate the pH value of an epoxy-based cement (Sealer 26) in different periods of analysis, using two assessment methods. Material and methods: Sealer 26 was manipulated and immediately placed into polyethylene tubes (n=10, each group) and immersed in distilled water. In G1, the tubes were kept in the same water during all experiment; and in G2, the tubes were removed and placed into another flask with an equal amount of water after the pH evaluation. The pH of these solutions was measured at 24 hours, 7, 14 and 28 days. Analysis were made within the same group according to the experimental periods and between groups in each experimental period. Data were submitted to ANOVA (α = 5%) and t test, respectively. Results: For G1 and G2, all periods showed different pH values (p < 0.05), except between 14 and 28 days (p > 0.05) and between 7 and 14 days (p > 0.05), respectively. In each period, no significant differences were observed between the groups. Conclusion: The method to obtain the pH values in different experimental periods no interfered in the final results. However, difference was observed when the results were analyzed at same group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the influence of the addition of 2% chlorhexidine digluconate (CHX) associated with 5% calcium chloride (CaCl2 ) on antimicrobial activity, setting time, pH and calcium release of gray mineral trioxide aggregate (GMTA). Materials and Methods: GMTA powder was mixed with water, 2% CHX alone or 2% CHX combined with 5% CaCl2 . Antimicrobial activity was determined against Enterococcus faecalis (ATCC 29212) strains by agar diffusion test. Data obtained were submitted to kruskal wallis tests. Analysis of the setting time was evaluated by American society for testing and materials C266-03 requirements. The pH and calcium release analysis were evaluated, in 24 h, 7, 14 and 28 days using pH meter equipment and atomic absorption spectrophotometer, respectively. Data obtained were analyzed by ANOVA, in 5% significance level. Results: Significant differences were seen (P < 0.01) among the zones of bacterial growth inhibition produced by 5% CaCl2 + 2% CHX combination against E. faecalis when compared with water (P < 0.05). Regarding the setting time, that combination had the shortest setting time (P < 0.05). All associations were alkaline and released calcium. No statistical difference was observed between the experimental groups at the different periods of analysis (P > 0.05). Conclusion: Combination of 5% CaCl2 + 2% CHX reduced the setting time and enhanced the antimicrobial activity of GMTA without changing the pH and calcium release.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study aimed to analyze and compare the role of a water-based exercise program versus a combination of water and callisthenic exercises on postural control, functional independence, and freezing of gait (FOG) in patients with mild to moderate Parkinson disease.Methods: Twenty-five community-dwelling participants with idiopathic Parkinson disease were recruited. Of these, 9 participants took part in a water-based program of physical exercises and the other 16 participants took part in a combined program that consisted of callisthenic exercises plus an aquatic exercise session. Both programs were 16 weeks in duration. The clinical evaluation assessed the festination by means of the FOG score test; postural control was verified by means of the balance test of the short physical performance battery, and the Spanish validated version of the Unified Parkinson's Disease Rating Scale part 2 was used to assess functional independence. Participants were evaluated before and after 16 weeks of both proposed programs.Results: The results showed improvement in FOG for both groups, although a significant main effect was observed only in the patients who performed the callisthenic exercise plus an aquatic exercise program. Postural control did not show significant improvements after both proposed physical exercise programs as soon as functional autonomy. Our preliminary results suggest that training sessions with the combination of water plus callisthenic exercises may be a useful physical rehabilitation strategy for individuals with mild to moderate Parkinson disease who have FOG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this letter, a semiautomatic method for road extraction in object space is proposed that combines a stereoscopic pair of low-resolution aerial images with a digital terrain model (DTM) structured as a triangulated irregular network (TIN). First, we formulate an objective function in the object space to allow the modeling of roads in 3-D. In this model, the TIN-based DTM allows the search for the optimal polyline to be restricted along a narrow band that is overlaid upon it. Finally, the optimal polyline for each road is obtained by optimizing the objective function using the dynamic programming optimization algorithm. A few seed points need to be supplied by an operator. To evaluate the performance of the proposed method, a set of experiments was designed using two stereoscopic pairs of low-resolution aerial images and a TIN-based DTM with an average resolution of 1 m. The experimental results showed that the proposed method worked properly, even when faced with anomalies along roads, such as obstructions caused by shadows and trees.