844 resultados para metrological reliability


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The metrological principles of neutron activation analysis are discussed. It has been demonstrated that this method can provide elemental amount of substance with values fully traceable to the SI. The method has been used by several laboratories worldwide in a number of CCQM key comparisons - interlaboratory comparison tests at the highest metrological level - supplying results equivalent to values from other methods for elemental or isotopic analysis in complex samples without the need to perform chemical destruction and dissolution of these samples. The CCOM accepted therefore in April 2007 the claim that neutron activation analysis should have the similar status as the methods originally listed by the CCOM as `primary methods of measurement`. Analytical characteristics and scope of application are given.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is evidence that cognitions (beliefs) and mood contribute to physical disability and work status in people with chronic pain. However, most of the current evidence comes from North America and Europe. This study examined the contribution of demographic, pain and psychosocial factors to disability and work status in chronic pain patients in two matched samples from quite different countries (Australia and Brazil). Data were collected from 311 chronic pain patients in each country. The results suggest that although demographic and pain variables (especially pain levels) contribute disability, self-efficacy beliefs made a significant contribution to disability in both samples. Age and educational level also contributed to unemployment in both samples. But there were some differences, with self-efficacy and physical disability contributing to work status only in the Brazilian sample. In contrast, depression was the only psychological risk factor for unemployment in the Australian sample. Catastrophising and pain acceptance did not contribute to disability or unemployment in either sample. These findings confirm key aspects of biopsychosocial models of pain in two culturally and linguistically different chronic pain samples from different countries. They suggest that different chronic pain populations may share more similarities than differences. (C) 2008 European Federation of Chapters of the International Association for the Study of Pain. Published

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to validate the Piper Fatigue Scale-Revised (PFS-R) for use in Brazilian culture. Translation of the PFS-R into Portuguese and validity and reliability tests were performed. Convenience samples in Brazil we as follows: 584 cancer patients (mean age 57 +/- 13 years; 51.3% female); 184 caregivers (mean age 50 +/- 12.7 years; 65.8% female); and 189 undergraduate nursing students (mean age 21.6 +/- 2.8 years; 96.2% female); Instruments used were as follows: Brazilian PFS, Beck Depression Inventory (BDI), and Karnofsky Performance Scale (KPS). The 22 items of the Brazilian PFS loaded well (factor loading > 0.35) on three dimensions identified by factor analysis (behavioral, affective, and sensorial-psychological). These dimensions explained 65% of the variance. Internal consistency reliability was very good (Cronbach`s alpha ranged from 0.841 to 0.943 for the total scale and its dimensions). Cancer patients and their caregivers completed the Brazilian PFS twice for test-retest reliability and results showed good stability (Pearson`s r a parts per thousand yenaEuro parts per thousand 0,60, p < 0,001). Correlations among the Brazilian PFS and other scales were significant, in hypothesized directions, and mostly moderate contributing to divergent (Brazilian PFS x KPS) and convergent validity (Brazilian PFS x BDI). Mild, moderate, and severe fatigue in patients were reported by 73 (12.5%), 167 (28.6%), and 83 (14.2%), respectively. Surprisingly, students had the highest mean total fatigue scores; no significant differences were observed between patients and caregivers showing poor discriminant validity. While the Brazilian PFS is a reliable and valid instrument to measure fatigue in Brazilian cancer patients, further work is needed to evaluate the discriminant validity of the scale in Brazil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. To compare the measurements of women`s pelvic floor musculature strength (PFMS) during pregnancy and postpartum period. Background. Pregnancy and childbirth can have an influence on the muscles and pelvic floor and can cause morbidities of women`s genito-urinary tract. Design. A prospective cohort study. Methods. There were included 226 primigravidae women, attended by community health services in the city of Itapecerica da Serra, Sao Paulo, Brazil. The participants were followed in four stages: (1) within 12 weeks of pregnancy; (2) between 36-40 weeks of pregnancy; (3) within 48 hours after childbirth; (4) 42-60 days after childbirth. Data were collected from February 2007-August 2008. The pelvic floor musculature strength was evaluated by perineometry and digital vaginal palpation in stages 1, 2 and 4. The final sample included 110 women who completed all four stages of the study. Results. The pelvic floor musculature strength of the women did not change significantly during pregnancy or after delivery (anova: p = 0 center dot 78). In all three examined stages, a low-intensity pelvic floor musculature strength was prevalent (in mmHg: stage 1 = 15 center dot 9; stage 2 = 15 center dot 2, stage 4 = 14 center dot 7), with scores from 0-3 on the Oxford scale. The pelvic floor musculature strength did not differ in relation to maternal age, skin colour, conjugal status, dyspareunia, stool characteristics, type of delivery, or conditions of the perineum. An interaction between maternal nutritional state and newborn`s weight may affect the pelvic floor musculature strength (manova: p = 0 center dot 04). Conclusion. Pregnancy and childbirth did not reduce significantly pelvic floor musculature strength. The perineometry and digital vaginal palpation used to assess the pelvic floor musculature strength were well accepted by the women. Relevance to clinical practice. In clinical practice, digital vaginal palpation is effective for supporting the diagnosis of urinary, intestinal and sexual dysfunctions. Perineometry use is particularly important together with the performance of perineal exercises with biofeedback in the treatment these disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Postural assessment through photography is a simple method that allows the acquisition of quantitative values to define the alignment of body segments. The purpose of this study was to quantitatively assess the postural alignment of several body segments in standing through anterior, posterior, and lateral views. Methods: In this cross-sectional study, 122 subjects were initially evaluated. Seven subjects were excluded from the study after cluster analysis. The final sample had 115 subjects, 75% women with a mean age of 26 + 7 years. Photographs were taken from anterior, posterior, and lateral views after placement of markers on specific anatomical points. Photographs were analyzed using free Postural Analysis Software/Software of Postural Analysis (PAS/SAPO). Quantitative values for postural analysis variables were ascertained for head, upper and lower limbs, and trunk, along with the frequency of inclinations to the left and to the right. Results: Regarding the head, 88% of the sample presented some inclination, 67% of which was to the right. There was a predominance of right inclination of the shoulder and pelvis in 68% and 43% of study subjects, respectively. Lower limbs presented mean alignment of 178 in the anterior view, and the trunk showed predominant right inclination in 66% of participants. Conclusion: Small asymmetries were observed in anterior and posterior views. This study suggests that there is no symmetry in postural alignment and that small asymmetries represent the normative standard for posture in standing. (J Manipulative Physiol Ther 2011;34:371-380)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Study Aim: Evaluation of sport skills test can be very useful tool for coach practice. The aim of the present paper was: (a) to evaluate the reliability and accuracy of the Specific Physical Fitness Tests (SPFT) (b) to review the results of karate athletes who represent different weight categories, and who are at different stages of schooling; (c) to establish grading criteria of physical fitness preparation. Material/Methods: The reseach was conducted among 219 Kyokushin karate players, whose profiles were presented as (chi) over bar +/- SD and their main characteristics were the following: age 26.8 +/- 4.67 (19-39) years, body mass 75.2 +/- 8.35 (50-97) kg and body height 176.4 +/- 5.67 (160-196) cm. The value of the BMI amounted to 24.1 +/- 2.17 (17.9-29.4) kg/m(2). All the subjects of the research had training experience of 10.5 +/- 3.71 (4-20) years and their degree of proficiency ranged from 4(th) kyu to 3(rd) dan. The physical fitness trials proposed by Story (1989) included: hip turning speed, speed punches, flexibility, rapid kicks, agility, and evasion actions. It was supplemented by a test of local strength endurance, composing a battery of the SPFT, which was implemented by first of the authors between 1991 and 2006. Results: SPFT is characterized by high reliability and it can be used to diagnose the physical fitness preparation and monitor the individual results of training. It discriminates accurately competitors with different sports level and it is characterized by very high accuracy, it is correlated with the test results of motor general physical fitness abilities and coordination abilities as well as it is connected with the somatic build of the athlete. The performance classification table was developed on the basis of our research. Discussion: Results obtained in SPFT were shortly discussed. Conclusions: The collected results of our research allowed us to come to, the conclusion: The table can be applied not only to assess karate fighters, but also adepts in taekwondo, kick-boxing, ju-jitsu, hapkido or other mixed martial arts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pinto, ALS, Oliveira, NC, Gualano, B, Christmann, RB, Painelli, VS, Artioli, GG, Prado, DML, and Lima, FR. Efficacy and safety of concurrent training in systemic sclerosis. J Strength Cond Res 25(5): 1423-1428, 2011-The optimal training model for patients with systemic sclerosis (SSc) is unknown. In this study, we aimed to investigate the effects of a 12-week combined resistance and aerobic training program (concurrent training) in SSc patients. Eleven patients with no evidence of pulmonary involvement were recruited for the exercise program. Lower and upper limb dynamic strengths (assessed by 1 repetition maximum [1RM] of a leg press and bench press, respectively), isometric strength (assessed by back pull and handgrip tests), balance and mobility (assessed by the timed up-and-go test), muscle function (assessed by the timed-stands test), Rodnan score, digital ulcers, Rayland`s phenomenon, and blood markers of muscle inflammation (creatine kinase and aldolase) were assessed at baseline and after the 12-week program. Exercise training significantly enhanced the 1RM leg press (41%) and 1RM bench press (13%) values and back pull (24%) and handgrip strength (11%). Muscle function was also improved (15%), but balance and mobility were not significantly changed. The time-to-exhaustion was increased (46.5%, p = 0.0004), the heart rate at rest condition was significantly reduced, and the workload and time of exercise at ventilatory thresholds and peak of exercise were increased. However, maximal and submaximal (V)over dotO(2) were unaltered (p > 0.05). The Rodnan score was unchanged, and muscle enzymes remained within normal levels. No change was observed in digital ulcers and Raynaud`s phenomenon. This is the first study to demonstrate that a 12-week concurrent training program is safe and substantially improves muscle strength, function, and aerobic capacity in SSc patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Throughout the year of 2004, 54 samples (I L each) were collected from commercial sources in the Vale do Paraiba region (eastern portion of Sao Paulo State, Brazil). The concentrations of (Ca, Cr, Cu, Fe, Mg, Mn, Ni, Se, Zn, Cd and Pb) in these samples were analyzed by two atomic-absorption spectroscopy (AAS) methods. Ca, Cu, Fe, Mg and Zn were determined by flame atomic-absorption spectroscopy (FAAS) and (Cd, Cr, Mn, Ni, Pb and Se) were determined by electrothermal atomic-absorption spectroscopy (ETAAS). Tests to determine and quantify essential, nonessential and toxic elements present in bovine milk are rare in Brazil, especially so for Vale do Paraiba region. Tests were performed on standard NIST-certified milk-powder to validate the reliability of subsequently collected analytical data. Ca presented a lower recovery value (85.3%). The finding for Ca macro-nutrient was found to be below recommended international standards (1300 mg/L) for all samples possibly due to milk heterogeneity and losses in the pasteurization process. Significant results for Pb were found in all milk samples with average values at 0.230 mg/L from a minimum of 0.062 mg/L and maximum of 0.476 mg/L (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The Burns Specific Health Scale-Revised (BSHS-R) is of easy application, can be self-administered, and it is considered a good scale to evaluate various important life aspects of burn victims. Objectives: To translate and culturally adapt the BSHS-R into the Brazilian-Portuguese language and to evaluate the internal consistency and convergent validity of the translated BSHS-R. Methods: The cultural adaptation of the BSHS-R included translation and back-translation, discussions with professionals and patients to ensure conceptual equivalence, semantic evaluation, and pre-test of the instrument. The Final Brazilian-Portuguese Version (FBPV) of the BSHS-R was tested on a group of 115 burn patients for internal consistency and validity of construct (using the Rosenberg Self-Esteem Scale (RSES) and the Beck Depression Inventory (BDI)). Results: All values of Cronbach`s alpha were greater than. 8, demonstrating that the internal consistency of the FBPV was very high. Self-esteem was highly correlated with affect and body image (r = .59, p < .001), and with interpersonal relationships (T = .51, p < .001). Correlations between the domains of the FBPV and the BDI were all negative but larger in magnitude than the correlations with RSES. Depression was highly correlated with affect and body image (r = -77, p < .001), and with interpersonal relationships (r = -67, p < .001). Conclusions: The results showed that the adapted version of the BSHS-R into Brazilian-Portuguese fulfills the validity and reliability criteria required from an instrument of health status assessment for burn patients. (C) 2008 Elsevier Ltd and ISBI. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a three-stage offline approach to detect, identify, and correct series and shunt branch parameter errors. In Stage 1 the branches suspected of having parameter errors are identified through an Identification Index (II). The II of a branch is the ratio between the number of measurements adjacent to that branch, whose normalized residuals are higher than a specified threshold value, and the total number of measurements adjacent to that branch. Using several measurement snapshots, in Stage 2 the suspicious parameters are estimated, in a simultaneous multiple-state-and-parameter estimation, via an augmented state and parameter estimator which increases the V - theta state vector for the inclusion of suspicious parameters. Stage 3 enables the validation of the estimation obtained in Stage 2, and is performed via a conventional weighted least squares estimator. Several simulation results (with IEEE bus systems) have demonstrated the reliability of the proposed approach to deal with single and multiple parameter errors in adjacent and non-adjacent branches, as well as in parallel transmission lines with series compensation. Finally the proposed approach is confirmed on tests performed on the Hydro-Quebec TransEnergie network.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents the study and development of a combined fault location scheme for three-terminal transmission lines using wavelet transforms (WTs). The methodology is based on the low- and high-frequency components of the transient signals originated from fault situations registered in the terminals of a system. By processing these signals and using the WT, it is possible to determine the time of travelling waves of voltages and/or currents from the fault point to the terminals, as well as estimate the fundamental frequency components. A new approach presents a reliable and accurate fault location scheme combining some different solutions. The main idea is to have a decision routine in order to select which method should be used in each situation presented to the algorithm. The combined algorithm was tested for different fault conditions by simulations using the ATP (Alternative Transients Program) software. The results obtained are promising and demonstrate a highly satisfactory degree of accuracy and reliability of the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hybrid active-passive damping treatments combine the reliability, low cost and robustness of viscoelastic damping treatments and the high-performance, modal selective and adaptive piezoelectric active control. Numerous hybrid damping treatments have been reported in the literature. They differ mainly by the relative positions of viscoelastic treatments, sensors and piezoelectric actuators. In this work we present an experimental analysis of three active-passive damping design configurations applied to a cantilever beam. In particular, two design configurations based on the extension mode of piezoelectric actuators combined with viscoelastic constrained layer damping treatments and one design configuration with shear piezoelectric actuators embedded in a sandwich beam with viscoelastic core are analyzed. For comparison purposes, a purely active design configuration with an extension piezoelectric actuator bonded to an elastic beam is also analyzed. The active-passive damping performance of the four design configurations is compared. Results show that active-passive design configurations provide more reliable and wider-range damping performance than the purely active configuration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The selection criteria for Euler-Bernoulli or Timoshenko beam theories are generally given by means of some deterministic rule involving beam dimensions. The Euler-Bernoulli beam theory is used to model the behavior of flexure-dominated (or ""long"") beams. The Timoshenko theory applies for shear-dominated (or ""short"") beams. In the mid-length range, both theories should be equivalent, and some agreement between them would be expected. Indeed, it is shown in the paper that, for some mid-length beams, the deterministic displacement responses for the two theories agrees very well. However, the article points out that the behavior of the two beam models is radically different in terms of uncertainty propagation. In the paper, some beam parameters are modeled as parameterized stochastic processes. The two formulations are implemented and solved via a Monte Carlo-Galerkin scheme. It is shown that, for uncertain elasticity modulus, propagation of uncertainty to the displacement response is much larger for Timoshenko beams than for Euler-Bernoulli beams. On the other hand, propagation of the uncertainty for random beam height is much larger for Euler beam displacements. Hence, any reliability or risk analysis becomes completely dependent on the beam theory employed. The authors believe this is not widely acknowledged by the structural safety or stochastic mechanics communities. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper addresses the time-variant reliability analysis of structures with random resistance or random system parameters. It deals with the problem of a random load process crossing a random barrier level. The implications of approximating the arrival rate of the first overload by an ensemble-crossing rate are studied. The error involved in this so-called ""ensemble-crossing rate"" approximation is described in terms of load process and barrier distribution parameters, and in terms of the number of load cycles. Existing results are reviewed, and significant improvements involving load process bandwidth, mean-crossing frequency and time are presented. The paper shows that the ensemble-crossing rate approximation can be accurate enough for problems where load process variance is large in comparison to barrier variance, but especially when the number of load cycles is small. This includes important practical applications like random vibration due to impact loadings and earthquake loading. Two application examples are presented, one involving earthquake loading and one involving a frame structure subject to wind and snow loadings. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a mixed validation approach based on coloured Petri nets and 3D graphic simulation for the design of supervisory systems in manufacturing cells with multiple robots. The coloured Petri net is used to model the cell behaviour at a high level of abstraction. It models the activities of each cell component and its coordination by a supervisory system. The graphical simulation is used to analyse and validate the cell behaviour in a 3D environment, allowing the detection of collisions and the calculation of process times. The motivation for this work comes from the aeronautic industry. The automation of a fuselage assembly process requires the integration of robots with other cell components such as metrological or vision systems. In this cell, the robot trajectories are defined by the supervisory system and results from the coordination of the cell components. The paper presents the application of the approach for an aircraft assembly cell under integration in Brazil. This case study shows the feasibility of the approach and supports the discussion of its main advantages and limits. (C) 2011 Elsevier Ltd. All rights reserved.