999 resultados para fleet safety


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dr Kevin Cooper of the Institute for Global Food Security at Queen’s University Belfast, Northern Ireland, spoke to Kate Mosford of The
Column about the importance of accuracy, reliability, and stability in food safety analysis and the role of ultrahigh-pressure liquid chromatography tandem mass spectrometry (UHPLC–MS–MS) in his research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective

Global migration of healthcare workers places responsibility on employers to comply with legal employment rights whilst ensuring patient safety remains the central goal. We describe the pilot of a communication assessment designed for doctors who trained and communicated with patients and colleagues in a different language from that of the host country. It is unique in assessing clinical communication without assessing knowledge.

Methods

A 14-station OSCE was developed using a domain-based marking scheme, covering professional communication and English language skills (speaking, listening, reading and writing) in routine, acute and emotionally challenging contexts, with patients, carers and healthcare teams. Candidates (n = 43), non-UK trained volunteers applying to the UK Foundation Programme, were provided with relevant station information prior to the exam.

Results

The criteria for passing the test included achieving the pass score and passing 10 or more of the 14 stations. Of the 43 candidates, nine failed on the station criteria. Two failed the pass score and also the station criteria. The Cronbach's alpha coefficient was 0.866.

Conclusion

This pilot tested ‘proof of concept’ of a new domain-based communication assessment for non-UK trained doctors.

Practice implications

The test would enable employers and regulators to verify communication competence and safety in clinical contexts, independent of clinical knowledge, for doctors who trained in a language different from that of the host country.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Primary results from the phase 3 ALSYMPCA trial showed that radium-223 dichloride (radium-223), a targeted α-emitter, improved overall survival compared with placebo and was well tolerated in patients with castration-resistant prostate cancer and symptomatic bone metastases. We did a prespecified subgroup analysis from ALSYMPCA to assess the effect of previous docetaxel use on the efficacy and safety of radium-223. 

Methods: In the phase 3, randomised, double-blind ALSYMPCA trial, patients with symptomatic castration-resistant prostate cancer, at least two symptomatic bone metastases, no known visceral metastases, and who were receiving best standard of care were randomly assigned (2:1) via an interactive voice response system to receive six injections of radium-223 (50 kBq/kg intravenously) or matching placebo, with one injection given every 4 weeks. Patients had either received previous docetaxel treatment or were unsuitable for or declined docetaxel; previous docetaxel use (yes or no) was a trial stratification factor. We investigated the effect of previous docetaxel use on radium-223 treatment for the primary endpoint of overall survival, the main secondary efficacy endpoints, and safety. Efficacy analyses were done for the intention-to-treat population; safety analyses were done for the safety population. The trial has been completed and is registered with ClinicalTrials.gov, number NCT00699751. 

Findings: Randomisation took place between June 12, 2008, and Feb 1, 2011. 526 (57%) of 921 randomly assigned patients had received previous docetaxel treatment (352 in the radium-223 group and 174 in the placebo group) and 395 (43%) had not (262 in the radium-223 group and 133 in the placebo group). Radium-223 prolonged median overall survival compared with placebo, irrespective of previous docetaxel use (previous docetaxel use, hazard ratio [HR] 0·70, 95% CI 0·56-0·88; p=0·002; no previous docetaxel use, HR 0·69, 0·52-0·92; p=0·01). The benefit of radium-223 compared with placebo was seen in both docetaxel subgroups for most main secondary efficacy endpoints; risk for time to time to first symptomatic skeletal event was reduced with radium-223 versus placebo in patients with previous docetaxel use, but the difference was not significant in those with no previous docetaxel use. 322 (62%) of 518 patients previously treated with docetaxel had grade 3-4 adverse events, compared with 205 (54%) of 383 patients without docetaxel. Patients who had previously been treated with docetaxel had a higher incidence of grade 3-4 thrombocytopenia with radium-223 than with placebo (31 [9%] of 347 patients vs five [3%] of 171 patients), whereas the incidence was similar between treatment groups among patients with no previous docetaxel use (seven [3%] of 253 patients vs one [1%] of 130 patients). The incidences of grade 3-4 anaemia and neutropenia were similar between the radium-223 and placebo groups within both docetaxel subgroups. 

Interpretation: Radium-223 is effective and well tolerated in patients with castration-resistant prostate cancer and symptomatic bone metastases, irrespective of previous docetaxel use. 

Funding: Algeta ASA and Bayer HealthCare Pharmaceuticals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the efficacy and safety of periprostatic lignocaine injection in trans-rectal ultrasound (TRUS) -guided biopsy of the prostate gland.

Methods: Ninety- six men (mean age 65 years, range 47-74) undergoing TRUS biopsy were randomised into the local anaesthetic (LA) or placebo group. Six to twelve biopsy cores were taken, the majority being 10 cores. Patients were asked to fill in the expected pain score on a visual analogue scale (VAS) prior to the procedure. They also completed the actual pain experienced on VAS after the biopsy. The incidence of complications was documented.

Results: The age, mean prostate specific antigen (PSA) were comparable in both groups. The expected pain score was also comparable (5.2 +/- 1.6 in LA, 5.0 +/- 1.4 in Placebo). In the LA group, the mean actual pain score was 3.0 +/- 1.8 and in the placebo group it was 6.5 +/- 2.2 (P = 0.0001). When patients were asked whether they would undergo the procedure again in the same way, 100% of the LA group and only 64% of the placebo group responded 'yes'(P=0.002 using Fisher's test). The complication rates were not significantly different between the two groups.

Conclusion: Peri-prostatic injection of local anaesthetic is safe and reduces discomfort significantly, and should be routinely offered to patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To prospectively evaluate and quantify the efficacy of cadaveric fascia lata (CFL) as an allograft material in pubovaginal sling placement to treat stress urinary incontinence (SUI).

Patients and methods Thirty-one women with SUI (25 type II and six type III; mean age 63 years, range 40-75) had a CFL pubovaginal sling placed transvaginally. The operative time, blood loss, surgical complications and mean hospital stay were all documented. Before and at 4 months and 1 year after surgery each patient completed a 3-day voiding diary and validated voiding questionnaires (functional inquiry into voiding habits, Urogenital Distress Inventory and Incontinence Impact Questionnaire, including visual analogue scales).

Results The mean (range) operative time was 71 (50-120) min, blood loss 78.7 (20-250) mL and hospital stay 1.2 (1-2) days; there were no surgical complications. Over the mean follow-up of 13.5 months, complete resolution of SUI was reported by 29 (93%) patients. Overactive bladder symptoms were present in 23 (74%) patients before surgery, 21 (68%) at 4 months and two (6%) at 1 year; 80% of patients with low (<15 cmH (2) O) voiding pressures before surgery required self-catheterization afterward, as did 36% at 4 months, but only one (3%) at 1 year. Twenty-four (77%) patients needed to adopt specific postures to facilitate voiding. After surgery there was a significant reduction in daytime frequency, leakage episodes and pad use (P <0.05). The severity of leak and storage symptoms was also significantly less (P <0.002), whilst the severity of obstructive symptoms remained unchanged. Mean subjective levels of improvement were 69% at 4 months and 85% at 1 year, with corresponding objective satisfaction levels of 61% and 69%, respectively. At 1 year, approximate to 80% of the patients said they would undergo the procedure again and/or recommend it to a friend.

Conclusion Placing a pubovaginal sling of CFL allograft is a highly effective, safe surgical approach for resolving SUI, with a short operative time and rapid recovery. Storage symptoms are significantly improved, and subjective improvement and satisfaction rates are high.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare the long-term outcome of artificial urinary sphincter (AUS) implantation in patients after prostatectomy, with and with no history of previous irradiation.

Patients and methods The study included 98 men (mean age 68 years) with urinary incontinence after prostatectomy for prostate cancer (85 radical, 13 transurethral resection) who had an AUS implanted. Twenty-two of the patients had received adjuvant external beam irradiation before AUS implantation. Over a mean (range) follow-up of 46 (5-118) months, the complication and surgical revision rates were recorded and compared between irradiated and unirradiated patients. The two groups were also compared for the resolution of incontinence and satisfaction, assessed using a questionnaire.

Results Overall, surgical revision was equally common in irradiated (36%) and unirradiated (24%) patients. After activating the AUS, urethral atrophy, infection and erosion requiring surgical revision were more common in irradiated patients (41% vs 11%; P <0.05); 70% of patients reported a significant improvement in continence, regardless of previous irradiation. Patient satisfaction remained high, with >80% of patients stating that they would undergo surgery again and/or recommend it to others, despite previous Irradiation and/or the need for surgical revision.

Conclusions Despite higher complication and surgical revision rates in patients who have an AUS implanted and have a history of previous Irradiation, the long-term continence and patient satisfaction appear not to be adversely affected.