889 resultados para evaluation of the quality in education
Resumo:
While navigation systems for cars are in widespread use, only recently, indoor navigation systems based on smartphone apps became technically feasible. Hence tools in order to plan and evaluate particular designs of information provision are needed. Since tests in real infrastructures are costly and environmental conditions cannot be held constant, one must resort to virtual infrastructures. This paper presents the development of an environment for the support of the design of indoor navigation systems whose center piece consists in a hands-free navigation method using the Microsoft Kinect in the four-sided Definitely Affordable Virtual Environment (DAVE). Navigation controls using the user's gestures and postures as the input to the controls are designed and implemented. The installation of expensive and bulky hardware like treadmills is avoided while still giving the user a good impression of the distance she has traveled in virtual space. An advantage in comparison to approaches using a head mounted display is that the DAVE allows the users to interact with their smartphone. Thus the effects of different indoor navigation systems can be evaluated already in the planning phase using the resulting system
Resumo:
BACKGROUND The coping resources questionnaire for back pain (FBR) uses 12 items to measure the perceived helpfulness of different coping resources (CRs, social emotional support, practical help, knowledge, movement and relaxation, leisure and pleasure, spirituality and cognitive strategies). The aim of the study was to evaluate the instrument in a clinical patient sample assessed in a primary care setting. SAMPLE AND METHODS The study was a secondary evaluation of empirical data from a large cohort study in general practices. The 58 participating primary care practices recruited patients who reported chronic back pain in the consultation. Besides the FBR and a pain sketch, the patients completed scales measuring depression, anxiety, resilience, sociodemographic factors and pain characteristics. To allow computing of retested parameters the FBR was sent to some of the original participants again after 6 months (90% response rate). We calculated consistency and retest reliability coefficients as well as correlations between the FBR subscales and depression, anxiety and resilience scores to account for validity. By means of a cluster analysis groups with different resource profiles were formed. Results. RESULTS For the study 609 complete FBR baseline data sets could be used for statistical analysis. The internal consistency scores ranged fromα=0.58 to α=0.78 and retest reliability scores were between rTT=0.41 and rTT=0.63. Correlation with depression, fear and resilience ranged from r=-0.38 to r=0.42. The cluster analysis resulted in four groups with relatively homogenous intragroup profiles (high CRs, low spirituality, medium CRs, low CRs). The four groups differed significantly in fear and depression (the more inefficient the resources the higher the difference) as well as in resilience (the more inefficient the lower the difference). The group with low CRs also reported permanent pain with no relief. The groups did not otherwise differ. CONCLUSIONS The FBR is an economic instrument that is suitable for practical use e.g. in primary care practices to identify strengths and deficits in the CRs of chronic pain patients that can then be specified in face to face consultation. However, due to the rather low reliability, the use of subscales for profile differentiation and follow-up measurement in individual diagnoses is limited.
Resumo:
OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.
Resumo:
In April 2008 a Franches-Montagnes colt was born with an unusual coat colour phenotype which had never been observed in that population before. The foal showed extended white markings on body and legs, a white head and blue eyes. As both parents have an unremarkable bay coat colour phenotype, a de novo mutation was expected in the offspring and a candidate gene approach revealed a spontaneous mutation in the microphthalmia associated transcription factor gene (MITF). A detailed clinical examination in 2010 indicated an impaired hearing capacity. As in the American Paint Horse large white facial markings in combination with blue eyes are associated with deafness, the hearing capacity of the stallion was closer examined performing brainstem auditory-evoked responses (BAER). The BAER confirmed bilateral deafness in the Franches-Montagnes colt. It is assumed that the deafness is caused by a melanocyte deficiency caused by the MITF gene mutation. Unfortunately, due to castration of the horse, the causal association between the mutation in the MITF gene and clinical findings cannot be confirmed by experimental matings.
Resumo:
OBJECTIVE To determine the diagnostic value of a serologic microagglutination test (MAT) and a PCR assay on urine and blood for the diagnosis of leptospirosis in dogs with acute kidney injury (AKI). DESIGN Cross-sectional study. Animals-76 dogs with AKI in a referral hospital (2008 to 2009). PROCEDURES Dogs' leptospirosis status was defined with a paired serologic MAT against a panel of 11 Leptospira serovars as leptospirosis-associated (n = 30) or nonleptospirosis-associated AKI (12). In 34 dogs, convalescent serologic testing was not possible, and leptospirosis status was classified as undetermined. The diagnostic value of the MAT single acute or convalescent blood sample was determined in dogs in which leptospirosis status could be classified. The diagnostic value of a commercially available genus-specific PCR assay was evaluated by use of 36 blood samples and 20 urine samples. RESULTS Serologic acute testing of an acute blood sample had a specificity of 100% (95% CI, 76% to 100%), a sensitivity of 50% (33% to 67%), and an accuracy of 64% (49% to 77%). Serologic testing of a convalescent blood sample had a specificity of 92% (65% to 99%), a sensitivity of 100% (87% to 100%), and an accuracy of 98% (88% to 100%). Results of the Leptospira PCR assay were negative for all samples from dogs for which leptospirosis status could be classified. CONCLUSIONS AND CLINICAL RELEVANCE Serologic MAT results were highly accurate for diagnosis of leptospirosis in dogs, despite a low sensitivity for early diagnosis. In this referral setting of dogs pretreated with antimicrobials, testing of blood and urine samples with a commercially available genus-specific PCR assay did not improve early diagnosis.
Resumo:
Foot-and-mouth disease (FMD) is highly contagious and one of the most economically devastating diseases of cloven-hoofed animals. Scientific-based preparedness about how to best control the disease in a previously FMD-free country is therefore essential for veterinary services. The present study used a spatial, stochastic epidemic simulation model to compare the effectiveness of emergency vaccination with conventional (non-vaccination) control measures in Switzerland, a low-livestock density country. Model results revealed that emergency vaccination with a radius of 3 km or 10 km around infected premises (IP) did not significantly reduce either the cumulative herd incidence or epidemic duration if started in a small epidemic situation where the number of IPs is still low. However, in a situation where the epidemic has become extensive, both the cumulative herd incidence and epidemic duration are reduced significantly if vaccination were implemented with a radius of 10 km around IPs. The effect of different levels of conventional strategy measures was also explored for the non-vaccination strategy. It was found that a lower compliance level of farmers for movement restrictions and delayed culling of IPs significantly increased both the cumulative IP incidence and epidemic duration. Contingency management should therefore focus mainly on improving conventional strategies, by increasing disease awareness and communication with stakeholders and preparedness of culling teams in countries with a livestock structure similar to Switzerland; however, emergency vaccination should be considered if there are reasons to believe that the epidemic may become extensive, such as when disease detection has been delayed and many IPs are discovered at the beginning of the epidemic.
Resumo:
BACKGROUND Mortality of patients with acute liver failure (ALF) is still unacceptably high. Available liver support systems are still of limited success at improving survival. A new type of albumin dialysis, the Hepa Wash® system, was newly introduced. We evaluated the new liver support system as well as the Molecular Adsorbent Recycling System (MARS) in an ischemic porcine model of ALF. METHODS In the first study animals were randomly allocated to control (n=5) and Hepa Wash (n=6) groups. In a further pilot study, two animals were treated with the MARS-system. All animals received the same medical and surgical procedures. An intraparenchymal intracranial pressure was inserted. Hemodynamic monitoring and goal-directed fluid therapy using the PiCCO system was done. Animals underwent functional end-to-side portacaval shunt and ligation of hepatic arteries. Treatment with albumin dialysis was started after fall of cerebral perfusion pressure to 45 mmHg and continued for 8 h. RESULTS All animals in the Hepa Wash group survived the 13-hour observation period, except for one that died after stopping treatment. Four of the control animals died within this period (p=0.03). Hepa Wash significantly reduced impairment of cerebral perfusion pressure (23±2 vs. 10±3 mmHg, p=0.006) and mean arterial pressure (37±1 vs. 24±2 mmHg, p=0.006) but had no effect on intracranial pressure (14±1 vs. 15±1 mmHg, p=0.72). Hepa Wash also enhanced cardiac index (4.94±0.32 vs. 3.36±0.25 l/min/m2, p=0.006) and renal function (urine production, 1850 ± 570 vs. 420 ± 180 ml, p=0.045) and eliminated water soluble (creatinine, 1.3±0.2 vs. 3.2±0.3 mg/dl, p=0.01; ammonia 562±124 vs. 1382±92 μg/dl, p=0.006) and protein-bound toxins (nitrate/nitrite 5.54±1.57 vs. 49.82±13.27 μmol/l, p=0.01). No adverse events that could be attributed to the Hepa Wash treatment were observed. CONCLUSIONS Hepa Wash was a safe procedure and improved multiorgan system failure in pigs with ALF. The survival benefit could be the result of ameliorating different organ functions in association with the detoxification capacity of water soluble and protein-bound toxins.
Resumo:
The "EMR Tutorial" is designed to be a bilingual online physician education environment about electronic medical records. After iterative assessment and redesign, the tutorial was tested in two groups: U.S. physicians and Mexican medical students. Split-plot ANOVA revealed significantly different pre-test scores in the two groups, significant cognitive gains for the two groups overall, and no significant difference in the gains made by the two groups. Users rated the module positively on a satisfaction questionnaire.
Resumo:
BACKGROUND: Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring 5-FU plasma levels in cancer patients in our routine clinical practice. METHODS: Performance of the Saladax My5-FU™ immunoassay was evaluated on the Roche Cobas® Integra 800 analyzer. Subsequently, 5-FU concentrations of 247 clinical plasma samples obtained with this assay were compared to the results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and other commonly used clinical analyzers (Olympus AU400, Roche Cobas c6000, and Thermo Fisher CDx90). RESULTS: The My-FU assay was successfully validated on the Cobas Integra 800 analyzer in terms of linearity, precision, accuracy, recovery, interference, sample carryover, and dilution integrity. Method comparison between the Cobas Integra 800 and LC-MS/MS revealed a proportional bias of 7% towards higher values measured with the My5-FU assay. However, when the Cobas Integra 800 was compared to three other clinical analyzers in addition to LC-MS/MS including 50 samples representing the typical clinical range of 5-FU plasma concentrations, only a small proportional bias (≤1.6%) and a constant bias below the limit of detection was observed. CONCLUSIONS: The My5-FU assay demonstrated robust and highly comparable performance on different analyzers. Therefore, the assay is suitable for monitoring 5-FU plasma levels in routine clinical practice and may contribute to improved efficacy and safety of commonly used 5-FU-based chemotherapies.
Resumo:
A process evaluation of the Houston Childhood Lead Poisoning Prevention Program, 1992-1995, was conducted. The Program's goal is to reduce lead poisoning prevalence. The study proposed to determine to what extent the Program was implemented as planned by measuring how well Program services were actually: (1) received by the intended target population; (2) delivered to children with elevated blood lead levels; (3) delivered in compliance with the Centers for Disease Control and Prevention and Program guidelines and timetables; and (4) able to reduce lead poisoning prevalence among those rescreened. Utilizing a program monitoring design, the Program's pre-collected computer records were reviewed. The study sample consisted of 820 children whose blood lead levels were above 15 micrograms per deciLiter, representing approximately 2.9% of the 28,406 screened over this period. Three blood lead levels from each participant were examined: the initial elevated result; the confirmatory result; and the next rescreen result, after the elevated confirmatory level. Results showed that the Program screened approximately 18% (28,406 of 161,569) of Houston's children under age 6 years for lead poisoning. Based on Chi-square tests of significance, results also showed that lead-poisoned participants were more likely to be younger than 3 years, male and Hispanic, compared to those not lead poisoned. The age, gender and ethnic differences observed were statistically significant (p =.01, p =.00, p =.00). Four of the six Program services: medical evaluations, rescreening, environmental inspections and confirmation, had satisfactory delivery completion rates of 71%-98%. Delivery timetable compliance rates for three of the six services examined: outreach contacts, home visits and environmental inspections were below 32%. However, dangerously elevated blood lead levels fell and lead poisoning prevalence dropped from 3.3% at initial screening to 1.2% among those rescreened, after intervention. From a public health perspective, reductions in lead poisoning prevalence are very meaningful. Based on these findings, the following are recommendations for future research: (1) integrate Program database files by utilizing a computer database management program; (2) target services at Hispanic male children under age 3 years living in the highest risk neighborhoods; (3) increase resources to: improve tracking and documentation of service delivery and provide more non-medical case management and environmental services; and (4) share the evaluation methodology/findings with the Centers for Disease Control and Prevention administrators; the implications may be relevant to other program managers conducting such assessments. ^
Resumo:
Many studies in biostatistics deal with binary data. Some of these studies involve correlated observations, which can complicate the analysis of the resulting data. Studies of this kind typically arise when a high degree of commonality exists between test subjects. If there exists a natural hierarchy in the data, multilevel analysis is an appropriate tool for the analysis. Two examples are the measurements on identical twins, or the study of symmetrical organs or appendages such as in the case of ophthalmic studies. Although this type of matching appears ideal for the purposes of comparison, analysis of the resulting data while ignoring the effect of intra-cluster correlation has been shown to produce biased results.^ This paper will explore the use of multilevel modeling of simulated binary data with predetermined levels of correlation. Data will be generated using the Beta-Binomial method with varying degrees of correlation between the lower level observations. The data will be analyzed using the multilevel software package MlwiN (Woodhouse, et al, 1995). Comparisons between the specified intra-cluster correlation of these data and the estimated correlations, using multilevel analysis, will be used to examine the accuracy of this technique in analyzing this type of data. ^
Resumo:
The Personal Response System Program at Huffington Center on Aging, Baylor College of Medicine, provides emergency call systems for elderly people living independently in Houston, Texas. The goal of the project was to complete a formative evaluation of the Personal Response System Program. The specific aims of the evaluation were three-fold. One aim was to evaluate participant health status and level of disability. The second aim was to develop a health care cost estimation strategy. Finally, a preliminary cost-effectiveness analysis was completed to evaluate the program's impact on health care costs and health status among the elderly target population. ^ The evaluation was a longitudinal, randomized experimental design. After the screening of 120 volunteers for eligibility, clients were asked to complete a written questionnaire and a monthly health service contact diary. Volunteers were contacted by telephone interviewers to collect health status information from 100 eligible clients (83%) on three occasions during the six months of follow-up. ^ Initially, volunteers were randomized to two experimental groups. The two groups were found to be comparable at the beginning of the study. No significant differences were detected related to health status, level of disability, or history of physician visits at baseline. However, the group with the Personal Response System (PRS) device had more adverse health events, higher IADL scores, more frequent use of walkers, lower average health status scores, and fewer community volunteers hours than the usual care comparison group. ^ The health care costs were estimated based on an algorithm adapted from the American Medical Association guidelines. Average total health care costs for the group with the PRS device ($912) were greater than the usual care group ($464). However, median health care values for the PRS group ($263) were similar to the usual care comparison group ($234). The preliminary findings indicated that the use of the PRS device was not associated with health care cost savings. ^ In the preliminary cost-effectiveness analysis, use of the personal response system was found to be associated with increased mental health status among elderly clients. The cost-effectiveness evaluation indicated that the associated cost for six months was $710 per unit increase in mental component score when the $150 PRS subscription was included. However, clients with the PRS device were found to have a greater decline in physical health status during the six-month follow-up. The beneficial effect on mental health status was found to be in contrast to negative findings associated with changes in physical health status. The implications for future research relate to the need to identify risk factors among geriatric populations to better target groups that would most likely benefit from PRS Program enrollment. ^
Resumo:
The biochemical determinants of cytotoxicity of the purine nucleoside analog, 9-(beta)-D-xylofuranosyladenine (xyl-A) were studied in wild-type Chinese hamster ovary cells and in nucleoside kinase deficient mutants. It was found that {('3)H}xyl-A was readily phosphorylated to the triphosphate level in both the wild-type and deoxycytidine kinase deficient mutant, but not by the adenosine kinase deficient cells. Values for the apparent Km and Vmax of this uptake process were 43.9 (mu)M and 118.7 nmol/min/10('9) cells, respectively. Cloning procedures indicated that the viability of CHO cells was decreased 90 per cent by a 5-hr incubation with 10 (mu)M xyl-A. However, the toxicity of xyl-A was increased 100-fold by the addition of a nontoxic concentration (10 (mu)M) of the adenosine deaminase inhibitor erythro-9-(2-hydroxy-3-nonyl)adenine (EHNA) to the medium. High-pressure liquid chromatographic analysis indicated that after 5 hr, the concentration of 9-(beta)-D-xylofuranosyladenine 5'-triphosphate (xyl-ATP) in cells incubated with xyl-A plus EHNA was 2.0 mM, four times greater than in those cells incubated with xyl-A alone. Incubation with xyl-A plus EHNA had no significant effect on the cellular concentrations of 5-phosphoribosyl-1-pyrophosphate after 1 hr whereas, treatment with 3'-dexoyadenosine (cordycepin) decreased the concentration of this metabolite. Determinations of the cellular nucleoside triphosphates indicated that under conditions that resulted in an intracellular accumulation of 500 (mu)M xyl-ATP, the endogenous concentrations of neither the ribonucleoside triphosphates nor deoxyribonucleoside triphosphates were significantly different from those of control cells. The ID(,50) for {('3)H}thymidine incorporation into DNA, 105 (mu)M xyl-ATP, was four-fold less than the ID(,50) for {('3)H}uridine incorporation into RNA suggesting that the process of DNA synthesis is more sensitive to the presence of xyl-ATP. When removed from exogenous xyl-A, CHO cells failed to recover their ability to synthesize RNA and DNA, although the intracellular xyl-ATP concentration decreased to less than 35 (mu)M. The selective inhibition of RNA synthesis by 6-azauridine did not prevent the expression of toxicity by xyl-ATP. However, the selective inhibition of DNA synthesis by ara-C significantly spared toxicity in cells that had accumulated an otherwise lethal concentration of xyl-ATP. It is shown that in cells which had accumulated 1.27 mM {('3)H}xyl-ATP, {('3)H}xyl-A was found to terminate cellular RNA chains at a frequency of 1.42 (mu)mol of {('3)H}xyl-A 3' termini per mol of mononucleotide. These results indicate that a general mechanism for the toxicity of xyl-A to CHO cells includes the cellular accumulation of xyl-ATP, which serves as a substrate for RNA synthesizing enzymes and subsequently is incorporated into nascent RNA transcripts as a chain terminator. A specific mechanism involving the premature termination of RNA primers required for the initiation of DNA synthesis is proposed to account for the inhibitory action of xyl-ATP on DNA synthesis. ^
Resumo:
PURPOSE To determine the image quality of an iterative reconstruction (IR) technique in low-dose MDCT (LDCT) of the chest of immunocompromised patients in an intraindividual comparison to filtered back projection (FBP) and to evaluate the dose reduction capability. MATERIALS AND METHODS 30 chest LDCT scans were performed in immunocompromised patients (Brilliance iCT; 20-40 mAs; mean CTDIvol: 1.7 mGy). The raw data were reconstructed using FBP and the IR technique (iDose4™, Philips, Best, The Netherlands) set to seven iteration levels. 30 routine-dose MDCT (RDCT) reconstructed with FBP served as controls (mean exposure: 116 mAs; mean CDTIvol: 7.6 mGy). Three blinded radiologists scored subjective image quality and lesion conspicuity. Quantitative parameters including CT attenuation and objective image noise (OIN) were determined. RESULTS In LDCT high iDose4™ levels lead to a significant decrease in OIN (FBP vs. iDose7: subscapular muscle 139.4 vs. 40.6 HU). The high iDose4™ levels provided significant improvements in image quality and artifact and noise reduction compared to LDCT FBP images. The conspicuity of subtle lesions was limited in LDCT FBP images. It significantly improved with high iDose4™ levels (> iDose4). LDCT with iDose4™ level 6 was determined to be of equivalent image quality as RDCT with FBP. CONCLUSION iDose4™ substantially improves image quality and lesion conspicuity and reduces noise in low-dose chest CT. Compared to RDCT, high iDose4™ levels provide equivalent image quality in LDCT, hence suggesting a potential dose reduction of almost 80%.