979 resultados para camera motion parameters
Resumo:
The objective of this work was to establish tissue culture parameters for gene transfer in sweet orange cultivars. Epicotyl explants with different ages were cultured with 6-benzylaminopurine (BAP), kanamycin and hygromycin. Shoots were cultured with alpha-naphthaleneacetic acid (NAA) alone or in combination with indole-3-butyric acid (IBA). The requirement of BAP for shoot development was genotype-specific. Epicotyl explants from 35-day-old seedlings produced significantly more shoots per explant in 'Pêra'. Kanamycin inhibited shoot regeneration for the most cultivars. The percentage of shoots that produced roots in 'Pêra' was significantly higher in medium with NAA and IBA than with NAA alone.
Resumo:
PURPOSE: A new magnetic resonance imaging approach for detection of myocardial late enhancement during free-breathing was developed. METHODS AND RESULTS: For suppression of respiratory motion artifacts, a prospective navigator technology including real-time motion correction and a local navigator restore was implemented. Subject specific inversion times were defined from images with incrementally increased inversion times acquired during a single dynamic scout navigator-gated and real-time motion corrected free-breathing scan. Subsequently, MR-imaging of myocardial late enhancement was performed with navigator-gated and real-time motion corrected adjacent short axis and long axis (two, three and four chamber) views. This alternative approach was investigated in 7 patients with history of myocardial infarction 12 min after i. v. administration of 0.2 mmol/kg body weight gadolinium-DTPA. CONCLUSION: With the presented navigator-gated and real-time motion corrected sequence for MR-imaging of myocardial late enhancement data can be completely acquired during free-breathing. Time constraints of a breath-hold technique are abolished and optimized patient specific inversion time is ensured.
Resumo:
PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.
Resumo:
The objective of this work was to evaluate the effects of chlorpyrifos on earthworms and on soil functional parameters. An integrated laboratory-field study was performed in a wheat field in Argentina, sprayed with chlorpyrifos at two recommended application rates (240 or 960 g ha-1 style='vertical-align:baseline'> a.i.). Laboratory tests included neutral red retention time, comet assay (single cell gel electrophoresis), and avoidance behavior, each using the earthworm Eisenia andrei exposed in soil collected 1 or 14 days after pesticide application, and the bait-lamina test. Field tests assessed organic matter breakdown using the litterbag and bait-lamina assays. Earthworm populations in the field were assessed using formalin application and hand-sorting. The neutral red retention time and comet assays were sensitive biomarkers to the effects of chlorpyrifos on the earthworm E. andrei; however, the earthworm avoidance test was not sufficiently robust to assess these effects. Feeding activity of soil biota, assessed by the bait lamina test, was significantly inhibited by chlorpyrifos after 97 days, but recovered by the 118th day of the test. Litterbag test showed no significant differences in comparison to controls. Earthworm abundance in the field was too low to adequately test the sensitivity of this assessment endpoint.
Resumo:
Let $ E_{\lambda}(z)=\lambda {\rm exp}(z), \lambda\in \mathbb{C}$, be the complex exponential family. For all functions in the family there is a unique asymptotic value at 0 (and no critical values). For a fixed $ \lambda$, the set of points in $ \mathbb{C}$ with orbit tending to infinity is called the escaping set. We prove that the escaping set of $ E_{\lambda}$ with $ \lambda$ Misiurewicz (that is, a parameter for which the orbit of the singular value is strictly preperiodic) is a connected set.
Resumo:
What is Iowa in Motion? The Iowa Department of Transportation is continuing the journey to develop Iowa’s future transportation system. This ongoing planning process, known as Iowa in Motion, was developed in response to the Intermodal Surface Transportation Efficiency Act (ISTEA) and Iowa’s changing transportation needs. The completion of Parts I, II and III of Iowa in Motion has led to development of this State Transportation Plan. Part IV includes activities, both current and future, to support the plan. This State Transportation Plan represents the thoughts and concerns of thousands of Iowans. Individuals, metropolitan planning organizations (MPOs), regional planning affiliations (RPAs), associations and organizations have become involved and have made recommendations concerning which direction should be followed regarding transportation investments. This plan represents their extensive input into the Iowa in Motion process and consensus building as we moved towards adoption of this State Transportation Plan. The adopted plan serves as a guide for development of transportation policies, goals, objectives, initiatives and investment decisions through the year 2020.
Resumo:
The objective of this work was to evaluate photoprotective mechanisms related to low positive temperatures in Coffea canephora (Conilon clones 02 and 153) and C. arabica ('Catucaí' IPR 102) genotypes, involved in cold temperature tolerance. To accomplish this, one-year-old plants were successively submitted to: temperature decrease of 0.5ºC day-1, from 25/20ºC to 13/8ºC; a three-day chilling cycle at 13/4ºC; and a recovery period of 14 days (25/20ºC). During the experiment, leaf gas exchange, chlorophyll a fluorescence and leaf photosynthetic pigment content were evaluated. Total activity of ribulose-1,5-bisphosphate carboxylase/oxygenase (Rubisco) and ribulose-5-phosphate kinase (Ru5PK) were quantified to measure the activity of photosynthesis key enzymes. All genotypes showed low temperature sensitivity, but displayed diverse cold impact and recovery capabilities regarding the photosynthetic-related parameters studied. Catucaí IPR 102 cultivar showed better ability to cope with cold stress than the Conilon clones, especially Conilon 02, and had full recovery of leaf gas exchange, fluorescence parameters, enzymatic activity, and higher contents of the photoprotective pigments zeaxanthin and lutein.
Resumo:
The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery
Resumo:
Purpose: To investigate the differences between the Fundus Camera (Topcon TRC-50X) and Confocal Scanning Laser Ophthalmoscope (Heidelberg retina angiogram (HRA)) on the fundus autofluorescence (FAF) imaging (resolution and FAF characteristics). Methods: Eighty nine eyes of 46 patients with various retinal diseases underwent FAF imaging with HRA (488nm exciter / 500nm barrier filter) before fluorescein angiography (FFA) and Topcon Fundus Camera (580nm exciter / 695nm barrier filter) before and after FFA. The quality of the FAF images was estimated, compared for their resolution and analysed for the influence of fixation stability and cataracts. Hypo- and hyper-FAF behaviour was analysed for the healthy disc, healthy fovea, and a variety of pathological features. Results: HRA images were found to be of superior quality in 18 eyes, while Topcon images were estimated superior in 21 eyes. No difference was found in 50 eyes. Both poor fixation (p=0.009) and more advanced cataract (p=0.013) were found to strongly increase the likelihood of better image quality by Topcon. Images acquired by Topcon before and after FFA were identical (100%). The healthy disc was usually dark on HRA (71%), but showed mild autofluorescence on Topcon (88%). The healthy fovea showed in 100% Hypo-FAF on HRA, while Topcon showed in 52% Iso-FAF, in 43% mild Hypo-FAF, and in 5% Hypo-FAF as on HRA. No difference of FAF was found for geographic atrophy, pigment changes, and drusen, although Topcon images were often more detailed. Hyper-FAF due to exudation showed better on HRA. Pigment epithelium detachment showed identical FAF behaviour on the border, but reduced FAF with Topcon in the center. Cystic edema was visible only on HRA in a petaloid pattern. Hard exsudates caused Hypo-FAF only on HRA, hardly visible on Topcon. Blocage phenomenon by blood however was identical. Conclusions: The filter set of Topcon and the single image acquisition appear to be an advantage for patients with cataract or poor fixation. Preceding FFA does not alter the Topcon FAF image. Regarding the FAF behaviour, there are differences between the two systems which need to be taken into account when interpreting the images.
Resumo:
Several methods and approaches for measuring parameters to determine fecal sources of pollution in water have been developed in recent years. No single microbial or chemical parameter has proved sufficient to determine the source of fecal pollution. Combinations of parameters involving at least one discriminating indicator and one universal fecal indicator offer the most promising solutions for qualitative and quantitative analyses. The universal (nondiscriminating) fecal indicator provides quantitative information regarding the fecal load. The discriminating indicator contributes to the identification of a specific source. The relative values of the parameters derived from both kinds of indicators could provide information regarding the contribution to the total fecal load from each origin. It is also essential that both parameters characteristically persist in the environment for similar periods. Numerical analysis, such as inductive learning methods, could be used to select the most suitable and the lowest number of parameters to develop predictive models. These combinations of parameters provide information on factors affecting the models, such as dilution, specific types of animal source, persistence of microbial tracers, and complex mixtures from different sources. The combined use of the enumeration of somatic coliphages and the enumeration of Bacteroides-phages using different host specific strains (one from humans and another from pigs), both selected using the suggested approach, provides a feasible model for quantitative and qualitative analyses of fecal source identification.
Resumo:
The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.
Resumo:
The objective of this work was to estimate the genetic parameters and variability among accessions (half-sib families) of physic nut (Jatropha curcas) during the early stages of development. For this study, 110 accessions in the first year of development of the physic nut germplasm bank, maintained at Embrapa Cerrados, DF, Brazil, were evaluated in situ. The experiment was established in a randomized complete block design, with two replicates and five plants per plot arranged in rows at 4x2 m spacing. Grain yield, total number of branches per plant, plant height, stem diameter, canopy projection on the row, canopy projection between rows, canopy volume, number of days until first flowering and height of the first inflorescence were evaluated. Estimates of vegetative genetic parameters showed the existence of genetic variability in the physic nut germplasm bank. Physic nut accessions of the germplasm bank were grouped into five similarity groups based on character divergence. Although preliminary, the obtained results are promising for showing potential for Jatropha improvement with selective efficiency.
Resumo:
The objective of this study was to estimate genetic parameters for survival and weight of Nile tilapia (Oreochromis niloticus), farmed in cages and ponds in Brazil, and to predict genetic gain under different scenarios. Survival was recorded as a binary response (dead or alive), during harvest time in the 2008 grow-out period. Genetic parameters were estimated using a Bayesian mixed linear-threshold animal model via Gibbs sampling. The breeding population consisted of 2,912 individual fish, which were analyzed together with the pedigree of 5,394 fish. The heritabilities estimates, with 95% posterior credible intervals, for tagging weight, harvest weight and survival were 0.17 (0.09-0.27), 0.21 (0.12-0.32) and 0.32 (0.22-0.44), respectively. Credible intervals show a 95% probability that the true genetic correlations were in a favourable direction. The selection for weight has a positive impact on survival. Estimated genetic gain was high when selecting for harvest weight (5.07%), and indirect gain for tagging weight (2.17%) and survival (2.03%) were also considerable.
Resumo:
Abstract
Resumo:
This project was undertaken to study the relationships between the performance of locally available asphalts and their physicochemical properties under Iowa conditions with the ultimate objective of development of a locally and performance-based asphalt specification for durable pavements. Physical and physicochemical tests were performed on three sets of asphalt samples including: (a) twelve samples from local asphalt suppliers and their TFOT residues, (b) six core samples of known service records, and (c) a total of 79 asphalts from 10 pavement projects including original, lab aged and recovered asphalts from field mixes, as well as from lab aged mixes. Tests included standard rheological tests, HP-GPC and TMA. Some specific viscoelastic tests (at 5 deg C) were run on b samples and on some a samples. DSC and X-ray diffraction studies were performed on a and b samples. Furthermore, NMR techniques were applied to some a, b and c samples. Efforts were made to identify physicochemical properties which are correlated to physical properties known to affect field performance. The significant physicochemical parameters were used as a basis for an improved performance-based trial specification for Iowa to ensure more durable pavements.