946 resultados para Ultra high-vacuum system
Demonstration of Solar Heating and Cooling System using Sorption Integrated Solar Thermal Collectors
Resumo:
Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a solar thermal collector. The module comprises a fully encapsulated sorption tube containing hygroscopic salt sorbent and water as a refrigerant, sealed under vacuum with no moving parts. A 5.6m2 aperture area outdoor laboratory-scale system of sorption module integrated solar collectors was installed in Stockholm, Sweden and evaluated under constant re-cooling and chilled fluid return temperatures in order to assess collector performance. Measured average solar cooling COP was 0.19 with average cooling powers between 120 and 200 Wm-2 collector aperture area. It was observed that average collector cooling power is constant at daily insolation levels above 3.6 kWhm-2 with the cooling energy produced being proportional to solar insolation. For full evaluation of an integrated sorption collector solar heating and cooling system, under the umbrella of a European Union project for technological innovation, a 180 m2 large-scale demonstration system has been installed in Karlstad, Sweden. Results from the installation commissioned in summer 2014 with non-optimised control strategies showed average electrical COP of 10.6 and average cooling powers between 140 and 250 Wm-2 collector aperture area. Optimisation of control strategies, heat transfer fluid flows through the collectors and electrical COP will be carried out in autumn 2014.
Resumo:
A ultra-sonografia obstétrica é um método diagnóstico tradicionalmente utilizado na rotina do atendimento pré-natal, tendo sido estudados de forma ampla suas vantagens e limitações. O advento do diagnóstico intra-uterino de cardiopatias congênitas e de arritmias através da ecocardiografia fetal modificou completamente o prognóstico perinatal dessas afecções, por permitir planejar o adequado manejo cardiológico no período neonatal imediato e, em algumas situações, o tratamento e sua resolução in utero. Sendo muito elevada a prevalência de cardiopatias congênitas durante a vida fetal, sua detecção torna-se fundamental. Considerando a inviabilidade operacional de realizar rotineiramente ecocardiografia fetal em todas as gestações, levando-se em conta as condições locais do sistema de saúde, o encaminhamento para exame por especialista passa a ser otimizado com a possibilidade da suspeita de alterações estruturais ou funcionais do coração e do sistema circulatório durante o exame ultra-sonográfico obstétrico de rotina. Não são conhecidos, em nosso meio, dados que avaliem de forma sistemática a acurácia da ultra-sonografia obstétrica no que se refere à suspeita pré-natal de cardiopatias. A partir deste questionamento, este trabalho foi delineado com o objetivo de avaliar o papel da ultra-sonografia obstétrica de rotina na suspeita pré-natal de cardiopatias congênitas ou arritmias graves e os fatores envolvidos na sua efetividade. A amostra foi constituída de 77 neonatos ou lactentes internados no Instituto de Cardiologia do Rio Grande do Sul / Fundação Universitária de Cardiologia (IC/FUC) no período de maio a outubro de 2000, com diagnóstico pós-natal confirmado de cardiopatia estrutural ou arritmia grave, que tenham sido submetidos, durante a vida fetal, a pelo menos uma ultra-sonografia obstétrica após a 18a semana de gestação. Para a coleta de dados, foi utilizado um questionário padronizado, respondido pelos pais ou responsáveis, após consentimento informado. As variáveis categóricas foram comparadas pelo teste do qui-quadrado ou pelo teste de Fisher, com um alfa crítico de 0,05. Um modelo de regressão logística foi utilizado para determinar variáveis independentes eventualmente envolvidas na suspeita pré-natal de cardiopatia. Em 19 pacientes (24,7%), a ultra-sonografia obstétrica foi capaz de levantar suspeita de anormalidades estruturais ou de arritmias. Ao serem consideradas apenas as cardiopatias congênitas, esta prevalência foi de 19,2% (14/73). Em 73,7% destes, as cardiopatias suspeitadas eram acessíveis ao corte de 4-câmaras isolado. Observou-se que 26,3% das crianças com suspeita pré-natal de cardiopatia apresentaram arritmias durante o estudo ecográfico, enquanto apenas 3,4% dos pacientes sem suspeita pré-natal apresentaram alterações do ritmo (P=0,009). Constituiram-se em fatores comparativos significantes entre o grupo com suspeita pré-natal e o sem suspeita a paridade (P=0,029), o parto cesáreo (P=0,006), a internação em unidade de tratamento intensivo (P=0,046) e a escolaridade paterna (P=0,014). Não se mostraram significativos o número de gestações, a história de abortos prévios, o estado civil, o sexo dos pacientes, o tipo de serviço e a localidade em que foram realizados o pré-natal e a ultra-sonografia obstétrica, a indicação da ecografia, o número de ultra-sonografias realizadas, a renda familiar e a escolaridade materna. À análise multivariada, apenas a presença de alteração do ritmo cardíaco durante a ultra-sonografia obstétrica mostrou-se como variável independente associada à suspeita pré-natal de anormalidade cardíaca. Este trabalho demonstra que a ultra-sonografia obstétrica de rotina ainda tem sido subutilizada no rastreamento pré-natal de cardiopatias congênitas, levantando a suspeita de anormalidades estruturais em apenas um quinto dos casos. Considerando a importância prognóstica do diagnóstico intra-uterino de cardiopatias congênitas e arritmias graves, todos os esforços devem ser mobilizados no sentido de aumentar a eficácia da ecografia obstétrica de rotina para a suspeita de anormalidades cardíacas fetais. O treinamento dirigido dos ultra-sonografistas e a conscientização do meio obstétrico e da própria população são instrumentos para esta ação.
Resumo:
High amylose cross-linked to different degrees with sodium trimetaphosphate by varying base strength (2% or 4%) and contact time (0.5-4 h) was evaluated as non-compacted systems for sodium diclophenac controlled release. The physical properties and the performance of these products for sodium diclophenac controlled release from non-compacted systems were related to the structures generated at each cross-linking degree. For samples at 2% until 2 h the swelling ability, G' and eta* values increased with the cross-linking degree, because the longer polymer chains became progressively more entangled and linked. This increases water uptake and holding, favoring the swelling and resulting in systems with higher viscosities. Additionally, the increase of cross-linking degree should contribute for a more elastic structure. The shorter chains with more inter-linkages formed at higher cross-linking degrees (2%4h and 4%) make water caption and holding difficult, decreasing the swelling, viscosity and elasticity. For 2% samples, the longer drug release time exhibited for 2%4h sample indicates that the increase of swelling and viscosity contribute for a more sustained drug release, but the mesh size of the polymeric network seems to be determinant for the attachment of drug molecules. For the 4% samples, smaller meshes size should determine less sustained release of drug. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
High amylose was cross-linked with sodium trimetaphosphate (STMP) using 2% and 4% solutions of NaOH at room temperature with reaction contact times of 0.5, 1, 2 and 4 h. The different polymers obtained were analyzed by FT IR, C-13 and P-31 solid state NMR, SEM and C, H and P elemental analysis. The results were used to propose a two-stage mechanism for phosphate incorporation, the first being kinetically controlled. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
In this work we describe a two-dimensional computer simulation of magnetic field enhanced plasma immersion implantation system. Negative bias voltage of 10.0 kV is applied to a cylindrical target located on the axis of a grounded vacuum chamber filled with uniform nitrogen plasma. A pair of external coils creates a static magnetic field with main vector component along the axial direction. Thus, a system of crossed ExB field is generated inside the vessel forcing plasma electrons to rotate in azimuthal direction. In addition, the axial variation of the magnetic field intensity produces magnetic mirror effect that enables axial particle confinement. It is found that high-density plasma regions are formed around the target due to intense background gas ionization by the trapped electrons. Effect of the magnetic field on the sheath dynamics and the implantation current density of the PIII system is investigated. By changing the magnetic field axial profile (varying coils separation) an enhancement of about 30% of the retained dose can be achieved. The results of the simulation show that the magnetic mirror configuration brings additional benefits to the PIII process, permitting more precise control of the implanted dose.
Resumo:
Precipitation of FeTiP is reported to occur in Ti-added IF steels containing high P during thermomechanical processing. An ultra-low carbon (ULC) Nb-added steel ingot containing a higher P content (< 0.8 wt-%) was produced via aluminothermic reduction of Fe2O3 followed by double electron beam melting (EBM). FeNbP coarse precipitates were observed in the as-cast microstructure. After soaking at 1050
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
X-ray photoelectron spectroscopy (XPS), x-ray diffraction (XRD), and x-ray absorption spectroscopy (XAS) techniques have been applied to characterize the surface composition and structure of a series of CuO-TiO2-CeO2 catalysts. For a small loading of cerium, ceria was mainly dispersed on the titania surface and a minor amount of CeO2 crystallite appeared. At higher loading of cerium, the CeO2 phase increased and the atomic Ce/Ti ratio values were smaller than the nominal composition, as a consequence of cerium agglomeration. This result suggests that only a fraction of cerium can be spread on the titania surface. For titanium-based mixed oxide, we observed that cerium is found as Ce3+ uniquely on the surface. The atomic Cu/(Ce+Ti) ratio values showed no influence from cerium concentration on the dispersion of copper, although the copper on the surface was shown to be dependent on the cerium species. For samples with a high amount of cerium, XPS analysis indicated the raise of second titanium species due cerium with spin-orbit components at higher binding energies than those presented by Ti4+ in a tetragonal structure. The structural results obtained by XAS are consistent with those obtained by XRD and XPS. (C) 2001 American Vacuum Society.
Resumo:
We consider here a Coulomb gauge quark model which includes an explicit construct for a nontrivial vacuum structure in QCD at finite density. Non-perturbative renormalization of ultraviolet diverges is performed by adding counterterms. The equation of state for u and d quark matter at zero temperature is calculated in the Hartree-Fock approximation.
Resumo:
Crowbar switches are largely used in plasma devices, such as field-reversed configuration (FRC) machines and tokamaks, to avoid energy return from the discharge coil to the capacitor bank. A method of identification of all resistances, inductances and currents involved in capacitor bank discharges using a crowbar is proposed based on the derivation of the general analytical form of the coil current. This analysis can also be used for optimization of the discharge, reducing the ripple amplitude inherent in the crowbar-switched current. Fitting results of the TC-1 UNICAMP FRC device are also presented in this work.
Resumo:
Branched polyethylene/high-density polyethylene blends (BPE/HDPE) with a wide range of molecular weights, melt flow indexes (MFI), and intrinsic viscosity were prepared using the homogeneous binary catalyst system composed by Ni(alpha-diimine)Cl-2 (1) (alpha-diimine = 1,4-bis(2,6-diisopropylphenyl)-acenaphthenediimine) and {Tp(Ms*)} TiCl3 (2) (Tp(Ms*)=hydridobis(3-mesitylpyrazol-1-yl)(5-mesityl-pyrazol-1-yl)) activated with MAO and/or TIBA in hexane at two different polymerization temperatures (30 and 55 degreesC) and by varying the nickel loading molar fraction (x(Ni)). At all Temperatures, a non-linear correlation between the x(Ni) and the productivity was observed, suggesting the occurrence of a synergistic effect between the nickel and the titanium catalyst precursors, which is more pronounced at 55 degreesC. The molecular weight of the BPE/HDPE blends considerably decreases with increasing Al/M molar ratio. The melt flow indexes (MFI) and intrinsic viscosities (eta) are strongly affected by x(Ni), but the melting temperatures are nearly constant, 132 +/- 3 degreesC. Dynamic mechanical thermal analysis (DMTA) shows the formation of different polymeric materials where the stiffness vanes according, to the x(Ni) and temperature used in the polymerization reaction. The surface morphology of the BPE/HDPE blends studied by scanning electron microscopy (SEM) revealed a low miscibility between the PE phases resulting in the formation of a sandwich structure after etching with o-xylene.
Resumo:
We report experiments of electron spin resonance (ESR) of Cu2+ in polycrystalline samples of CaCu3Ti4O12 post-annealed in different atmospheres. After being synthesized by solid state reaction, pellets of CaCu3Ti4O12 were annealed for 24 h at 1000 degrees C under air, Ar or O-2. Our temperature dependent ESR data revealed for all samples nearly temperature independent g value (2.15(1)) and linewidth for T > T-N approximate to 25 K. However, the values of ESR linewidth are strongly affected by the oxygen content in the sample. For instance, argon post-annealed samples show a much larger linewidth than the O-2 or air post-annealed samples. We attribute this broadening to an increase of the dipolar homogeneous broadening of the Cu2+ ESR lines due to the presence of oxygen vacancies which induce an S=1/2 spin inside the TiO6 octahedra. Correlation between a systematic dependence of the ESR linewidth on the oxygen content and the high dielectric constant of these materials is addressed. Also, ESR, magnetic susceptibility, and specific heat data for a single crystal of CaCu3Ti4O12 and for polycrystals of CdCu3Ti4O12 are reported.
Resumo:
High strain shear zones of Brasiliano age, developed in Paleoproterozoic basement gneiss of the Caicó region, Borborema Province, NE Brazil, were associated with medium- to low-grade metamorphism and deformational processes that transformed porphyritic augen gneiss into muscovite quartzite, modifying their original mineralogy and chemical properties. During the last hydrothermal event mobility of major, minor and trace elements was great, whereas the pattern of Rare Earth Elements was not changed. We carried out a Sm-Nd isotopic study in these rocks in order to understand the behavior of Nd isotopes during mylonite generation. TDM model ages at around 2.6 Ga and εNd (t) values for both protolith and transformed rock suggest that the Nd isotopic system remained closed, recording the original source rock signature, despite undergoing two superposed metamorphic events. These new Sm-Nd results provide important information on the geologic evolution of basement rocks in the central Rio Grande do Norte Terrane of the Borborema Province, NE Brazil.
Resumo:
The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.