902 resultados para Threshold voltage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper elaborates the notion of balanced'' financial development that is contingent on a country's general level of development. We develop an empirical framework to address this point, referring to threshold regressions and a bootstrap test for structural shift in a growth equation. We find that countries gain less from financial activity, if the latter fails to keep up with or exceeds what would follow from a balanced expansion path. These analyses contribute to the finance and growth literature in providing empirical support for the balanced'' financial development hypothesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the outcomes associated with two differing right unilateral (RUL) electroconvulsive therapy (ECT) dosing protocols: 2-3X seizure threshold (2-3X ST) and fixed high dose (FHD) at 353 mC. A retrospective chart review was performed to compare patient outcomes during the implementation of two different dosing protocols: 2-3X ST from October 2000 to May 2001 and FHD from June 2001 to February 2002. A total of 56 patients received ECT under the 2-3X ST protocol, and 46 received ECT under the FHD protocol. In total, 13.6% of patients receiving ECT according to the 2-3X ST protocol received more than 12 ECT, whereas none of the FHD group received more than 12 ECT. The mean number of ECT per treatment course reduced significantly from 7.6 to 5.7 following the switch from the 2-3X ST protocol to the FHD protocol. There were no significant differences between the two groups in the incidence of adverse cognitive effects. ECT practitioners adhered to the 2-3X ST protocol for only 51.8% of ECT courses, with protocol adherence improving to 87% following introduction of the FHD protocol. Although this naturalistic retrospective chart survey had significant methodological limitations, it found that practitioners are more likely to correctly adhere to a fixed dose protocol, therefore, increasing its 'real world' effectiveness in comparison to titrated suprathreshold dosing techniques. The FHD protocol was associated with shorter courses of ECT than the 2-3X ST protocol, with no significant difference between the two protocols in clinically discernable adverse cognitive effects.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional detection scheme for self-mixing sensors uses an integrated photodiode within the laser package to monitor the self mixing signal. This arrangement can be simplified by directly obtaining the self-mixing signals across the laser diode itself and omitting the photodiode. This work reports on a Vertical-Cavity Surface-Emitting Laser (VCSEL) based selfmixing sensor using the laser junction voltage to obtain the selfmixing signal. We show that the same information can be obtained with only minor changes to the extraction circuitry leading to potential cost saving with reductions in component costs and complexity and significant increase in bandwidth favoring high speed modulation. Experiments using both photo current and voltage detection were carried out and the results obtained show good agreement with the theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Error rates of a Boolean perceptron with threshold and either spherical or Ising constraint on the weight vector are calculated for storing patterns from biased input and output distributions derived within a one-step replica symmetry breaking (RSB) treatment. For unbiased output distribution and non-zero stability of the patterns, we find a critical load, α p, above which two solutions to the saddlepoint equations appear; one with higher free energy and zero threshold and a dominant solution with non-zero threshold. We examine this second-order phase transition and the dependence of α p on the required pattern stability, κ, for both one-step RSB and replica symmetry (RS) in the spherical case and for one-step RSB in the Ising case.