996 resultados para FUEL ELEMENTS
Resumo:
A new flow field was designed to search flow fields fitting polymer electrolyte membrane fuel cells (PEMFCs) better due its extensible. There are many independent inlets and outlets in the new flow field. The new flow field we named NINO can extend to be more general when pressures at the inlet and outlet vary and some usual flow fields will be obtained. A new mathematical model whose view angle is obverse is used to describe the flow field.
Resumo:
In this paper, it is reported for the first time that a carbon-supported Pd-P (Pd-P/C) catalyst for the anodic catalyst in the direct formic acid fuel cell (DFAFC) can be prepared. The Pd-P/C catalyst shows that its electrocatalytic activity and especially its stability for the oxidation of formic acid are much higher than that of a Pd/C catalyst. Therefore, the Pd-P/C catalyst may have practical applications in DFAFCs.
Resumo:
Polypyrrole (Ppy) was successfully introduced into methyl substituted sulfonated poly(ether ether ketone) (SPEEK) membranes by polymerization in SPEEK solutions to improve their methanol resistance. Uniform polypyrrole (Ppy) distributed composite membranes were formed by this method by the interaction between SPEEK and Ppy. The properties of the composite membranes were characterized in detail. The composite membranes show very good proton conductive capability (25 degrees C: 0.05-0.06s cm(-1)) and good methanol resistance (25 degrees C: 5.3 x 10(-7) 1.1 x 10(-6) cm(2) s(-1)). The methanol diffusion coefficients of composite membranes are much lower than that of pure SPEEK membranes (1.5 x 10(-6) cm(2) s(-1)). The composite membranes show very good potential usage in direct methanol fuel cells (DMFCs).
Resumo:
An additional anode catalyst layer with PtRu/C was hot pressed between two Nafion (R) 112 membranes and a conventional direct methanol fuel cell (DMFC) cathode/membrane/anode assembly with the above membranes as separator was fabricated. The additional catalyst layer formed an assistant cell with the cathode to prevent methanol crossover. A simple one-dimensional mathematical model was presented to describe the performance of this new type of membrane electrode assembly system. As seen from both experimental result and model analysis, the additional catalyst layer can not only effectively prevent the methanol crossover, but also generate electrical power with the crossover methanol. The percentage of output power of the assistant cell to the total power analyzed by the model is about 40% under usual condition, which is much higher than that from experimental result, indicating the potential of the development in the DMFC designing. It was also discovered that the electrical power generated from the assistant cell with crossover methanol could take higher percentage in total electrical power when the main DMFC current density became lower.
Resumo:
In this work, a method was established for the determination of impurities in high purity tellurium by inductively coupled plasma mass spectrometry (ICP-MS) after Fe(OH)(3) coprecipitation. After comparison of coprecipitation ability and separation efficiency between Fe(OH), and Al(OH)(3), Fe(OH)(3) was chosen as the precipitate. A separation factor of 160 for 200 mg tellurium was obtained under conditions of pH 9 and 2 mg of Fe3(+). The 13 elements, such as Bi, Sn, Pb, In, Tl, Cd, Cu, Co, Ni, Zn, Ti, Be and Zr, could be almost completely coprecipitated under these conditions. In addition, Te memory effect imposed on the ICP-MS instrument was assessed, as well as Te matrix effect that caused the low recovery of Ga, As, Sb and V in real sample was discussed. Finally, the method was evaluated through recovery test and was applied to practical sample analysis, with detection limits of most of the elements being below 0.15 mug g(-1) and R.S.D. below or at approximately 10%, which indicated that this method could fully satisfy the requirements for analysis of 99.999% similar to 99.9999% high purity Te.
Resumo:
A series of solid electrolytes, (Ce(0.8)Ln(0.2))(1 - x)MxO2 - delta(Ln = La, Nd, Sm, Gd, M:Alkali-earth), were prepared by amorphous citrate gel method. XRD patterns indicate that a pure fluorite phase is formed at 800 degreesC. The electrical conductivity and the AC impedance spectra were measured. XPS spectra show that the oxygen vacancies increase owing to the MO doping, which results in the increase of the oxygen ionic transport number and conductivity. The performance of ceria-based solid electrolyte is improved. The effects of rare-earth and alkali-earth ions on the electricity were discussed. The open-circuit voltages and maximum power density of planar solid oxide fuel cell using (Ce0.8Sm0.2)(1 - 0.05)Ca0.05O2 - delta as electrolyte are 0.86 V and 33 mW . cm(-2), respectively.
Resumo:
This paper presents the results of the adsorption of heavy rare earth ions (Gd(III), Tb(III), Dy(III), Ho(III), Er(III), Tm(III), Yb(III), Lu(III) and Y(III)) from hydrochloric acid solutions at 30 degreesC by the extraction resin containing 1-hexyl-4-ethyloctyl isopropylphosphonic acid (HEOPPA), which has higher steric hindrance, higher selectivities and lower extraction and stripping acidity than di(2-ethylhexyl)phosphoric acid (DERPA) or 2-ethylhexyl phosphonic acid mono-2-ethylhexyl ester (HEH/EHP). The dependence of acid concentration, flow rate and amounts of rare earth ions sorbed on the separation of Er-Tm, Tm-Yb and Er-Tm-Yb mixtures has been studied. The baseline chromatographic separation of Er-Tm-Yb mixture has been observed. Satisfactory results with purity and yield of Tm2O3>99.71% and >71.25%, Er2O3>99-81% and >94.17%, and Yb2O3>99.74% and >89.83%, respectively, have been obtained. The parameters such,as resolution, separation factors and efficiencies have been determined as a function of acidity, loading of rare earth elements and flow rates. The stoichiometry of the extraction of rare earth ions has been suggested as well.
Resumo:
The Pt/C catalysts were prepared with pine active carbon and Vulcan XC-72 active carbon as the supports. The performances of the Pt/C catalysts in polymer electrolyte membrane fuel cell were compared. The result indicates that the performance of Pt/Vulcan XC-72 is better than that of Pt/pine. The physical and chemical properties of the two active carbons were measured using several analysis techniques. It was found that the pore size, specific conductivity and the surface function group significantly influence the performance of the electrocatalyst.
Resumo:
The kinetics of RE (La, Gd, Er, Yb and Y) extraction with sec-octylphenoxy acetic acid was investigated using a constant interfacial area cell with laminar flow at 303 K. The natures of the extracted complexes have some effect on the extraction rate which is controlled by the reaction rate of M(III) and extractant molecules at two-phase interface for Er(III), Yb(III) and Y(III), by a mixed chemical reaction-diffusion for Gd(III) and a diffusion for La( III). The extractant molecules tend to adsorb at the interface. So an interfacial extraction reaction model was derived.
Resumo:
A method was developed for the determination of trace and ultratrace amounts of REE. Cd. In. Tl. Th. Nb, Ta. Zr and Hf in soils and sediments. With NaOH-Na2O2 as the flux. Ti(OH)(4)-Fe(OH)(3) co-precipitation as the preconcentration technique and inductively coupled plasma mass spectrometry (ICP-MS) for measurement, the whole procedure was concise and suitable for batch analysis of multi-element solutions. An investigation was carried out of the Ti(OH)(4)-Fe(OH)(3) co-precipitation system, and the results obtained showed that the natural situation of Ti tightly coexisting with Nb. Ta, Zr and Hf in geological samples plays a very important role in the complete co-precipitation of the four elements. The accuracy of this procedure was established using six Chinese soil and sediment certified reference materials (GSS and GSD). and the relative errors between the found and certified values were mostly below 10%.
Resumo:
Valence of elements in HgBa2Can-1CunO2n+2+delta (n=1, 2, 3, 4) (both argon and oxygen annealed samples) were calculated. The result indicated for both argon and oxygen annealed samples, Hg had the lowest valence for the highest T-c sample. For fixed n, the valence of Cu in oxygen annealed samples was larger than that in argon annealed samples, indicating that oxygen annealed samples produce more carriers than argon annealed samples.
Resumo:
Inductively coupled plasma mass spectrometry (ICP-MS),a highly sensitive inorgnic analytic technique,fits to determine ultra-nace rare-earth elements in human plasma. Under the optimized conditions detection limits for 15 rare-earth elements are in the range of 0.7 (for Eu)-5.4 (for Gd) ng.L-1. Indium as an internal standard element is used to compensate for matrix suppression effect and sensitivity drift. Three kinds of preparation methods, diluted with 1% HNO3, digested with HNO3-H2O2 and with HNO3-HClO4, are checked and compared,and the former is the simplest way to be measured. The samples diluted with 1% HNO3, stored in 4 degrees C, are very steady for 16 days. With the method, 11 healthy plasma samples in Changchun area of China are analysed.
Resumo:
A method for the determination of impurity elements in high purity cadmium by inductively coupled plasma mass spectrometry was developed. The spectral interference arising from Cd was discussed and the magnitude of interference by the polyatomic ion of Cd was compared. The effect of the high concentration Cd on the analyte signal was studied. The results showed that Cd possessed both significant suppression effects on the light mass elements signal and enhancement effects on the heavy mass elements signal,and the effects can be corrected by the use of internal standard elements. In this paper, Y and Bi was employed for the light mass elements and the heavy mass elements,respectively. As, Be, Co, Cu, Ga, Ge, Mn, Mo, Pb, Ni, Sr, Au, Tl, Th, V and U in high purity cadmium were determined. Detection limits are 0.005-0.052 mu g L-1,and the recoveries of standard addition are 82%-108%.
Resumo:
A method for the determiantion of rare earth elements in biological sampels by inductively coupled plasma mass spectrometry was developed. Oxide ion yield of the rare earth elements (RFE) decreased with the increasing of RF power and the sampling depth, or with the decreasing of carrier gas flow rate. The spectral interference arising from (PrO)-Pr-141-O-16 on Gd-157 must be corrected. if the concentration of Ba was high enough, it was necessary to correct the spectral interference arising from (BO)-B-135-O-16 on Eu-151, and it was not necessary to correct spectral interference arising from (NdO)-Nd-143-O-16 on Tb-159 etc. in the biological samples under the selected operation parameters. In the biological sample, the major matrix elements, such as K, Na and Ca, result in the suppression of REEs signals and the suppression degree of the Ca is grezter than that of the K and Na. The mussel sample was digested by thd dry ashing, wet digestion with HNO3 + H2O2 and HNO3 + HClO4, respectively. The analytical results of REEs were consistent with each other. Detection limits for REEs are 0.001 similar to 0.013 mu g/L. Recoveries of standard addition are 91.7% similar to 125%. REEs in biological samples were determined directly without separation and preconcentration procedure.