Determination of ultra-trace rare-earth elements in human plasma by inductively coupled plasma mass spectrometry


Autoria(s): Chen HT; Cao SQ; Zeng XJ; Meng L; Zao DQ; Ni JZ
Data(s)

2000

Resumo

Inductively coupled plasma mass spectrometry (ICP-MS),a highly sensitive inorgnic analytic technique,fits to determine ultra-nace rare-earth elements in human plasma. Under the optimized conditions detection limits for 15 rare-earth elements are in the range of 0.7 (for Eu)-5.4 (for Gd) ng.L-1. Indium as an internal standard element is used to compensate for matrix suppression effect and sensitivity drift. Three kinds of preparation methods, diluted with 1% HNO3, digested with HNO3-H2O2 and with HNO3-HClO4, are checked and compared,and the former is the simplest way to be measured. The samples diluted with 1% HNO3, stored in 4 degrees C, are very steady for 16 days. With the method, 11 healthy plasma samples in Changchun area of China are analysed.

Identificador

http://202.98.16.49/handle/322003/19621

http://www.irgrid.ac.cn/handle/1471x/154545

Idioma(s)

中文

Fonte

Chen HT;Cao SQ;Zeng XJ;Meng L;Zao DQ;Ni JZ.Determination of ultra-trace rare-earth elements in human plasma by inductively coupled plasma mass spectrometry,SPECTROSCOPY AND SPECTRAL ANALYSIS,2000,20(3):339-342

Tipo

期刊论文