961 resultados para FOOT BIOMECHANICS
Resumo:
A 51-year-old man, with a medical history of medullary thyroid carcinoma excised under thyroxine treatment presented with a painful enlarging lesion on his right heel since one year. A 3-cm diameter, greyish, infiltrated nodule with spicules was seen on physical examination (Fig. 1a). A 5-mm surgical excision was made and a total skin graft was used for reconstruction. Histopathology of the total resected tumour revealed pseudoepitheliomatous hyperplasic epidermis and a proliferation located between rete ridges, dermis and superficial hypodermis (Fig. 1b). The proliferation was composed of nets and cordons of cells with granular and abundant PAS-positive cytoplasm. Immunostains showed cytoplasmic positivity for s100 and inhibin (Fig. 1c). Three years later the patient is asymptomatic.
Resumo:
It is known that hypertension is associated with endothelial dysfunction and that Angiotensin II (Ang II) is a key player in the pathogenesis of hypertension. We aimed to elucidate whether endothelial dysfunction is a specific feature of Ang II-mediated hypertension or a common finding of hypertension, independently of underlying etiology. We studied endothelial-dependent vasorelaxation in precapillary resistance arterioles and in various large-caliber conductance arteries in wild-type mice with Ang II-dependent hypertension (2-kidney 1-clip (2K1C) model) or Ang II-independent (volume overload) hypertension (1-kidney 1-clip model (1K1C)). Normotensive sham mice were used as controls. Aortic mechanical properties were also evaluated. Intravital microscopy of precapillary arterioles revealed a significantly impaired endothelium-dependent vasorelaxation in 2K1C mice compared with sham mice, as quantified by the ratio of acetylcholine (ACh)-induced over S-nitroso-N-acetyl-D,L-penicillamine (SNAP)-induced vasorelaxation (2K1C: 0.49±0.12 vs. sham: 0.87±0.11, P=0.018). In contrast, the ACh/SNAP ratio in volume-overload hypertension 1K1C mice was not significantly different from sham mice, indicating no specific endothelial dysfunction (1K1C: 0.77±0.27 vs. sham: 0.87±0.11, P=0.138). Mechanical aortic wall properties and endothelium-dependent vasorelaxation, assessed ex vivo in rings of large-caliber conductance (abdominal and thoracic aorta, carotid and femoral arteries), were not different between 2K1C, 1K1C and sham mice. Endothelial dysfunction is an early feature of Ang II- but not volume-overload-mediated hypertension. This occurs exclusively at the level of precapillary arterioles and not in conduit arteries. Our findings, if confirmed in clinical studies, will provide a better understanding of the pathophysiological mechanisms of hypertension.
Resumo:
OBJECTIVE: To investigate the influence of obesity on the regulation of myocardial glucose metabolism following protein kinase C (PKC) activation in obese (fa/fa) and lean (Fa/?) Zucker rats. DESIGN: Isolated hearts obtained from 17-week-old lean and obese Zucker rats were perfused with 200 nM phorbol 12-myristate 13-acetate (PMA) for different time periods prior to the evaluation of PKC and GLUT-4 translocation. For metabolic studies isolated hearts from 48 h starved Zucker rats were perfused with an erythrocytes-enriched buffer containing increased concentrations (10-100 nM) of PMA. MEASUREMENTS: Immunodetectable PKC isozymes and GLUT-4 were determined by Western blots. Glucose oxidation and glycolysis were evaluated by measuring the myocardial release of 14CO2 and 3H2O from [U-14C]glucose and [5-3H]glucose, respectively. RESULTS: PMA (200 nM) induced maximal translocation of ventricular PKCalpha from the cytosol to the membranes within 10 min. This translocation was 2-fold lower in the heart from obese rats when compared to lean rats. PMA also induced a significant translocation of ventricular GLUT-4 from the microsomal to the sarcolemmal fraction within 60 min in lean but not in obese rats. Rates of basal cardiac glucose oxidation and glycolysis in obese rats were approximately 2-fold lower than those of lean rats. Perfusion with increasing concentrations of PMA (10-100 nM) led to a significant decrease of cardiac glucose oxidation in lean but not in obese rats. CONCLUSION: Our results show that in the heart of the genetically obese Zucker rat, the impairment in PKCalpha activation is in line with a diminished activation of GLUT-4 as well as with the lack of PMA effect on glucose oxidation.
Resumo:
Measurement of three-dimensional (3D) knee joint angle outside a laboratory is of benefit in clinical examination and therapeutic treatment comparison. Although several motion capture devices exist, there is a need for an ambulatory system that could be used in routine practice. Up-to-date, inertial measurement units (IMUs) have proven to be suitable for unconstrained measurement of knee joint differential orientation. Nevertheless, this differential orientation should be converted into three reliable and clinically interpretable angles. Thus, the aim of this study was to propose a new calibration procedure adapted for the joint coordinate system (JCS), which required only IMUs data. The repeatability of the calibration procedure, as well as the errors in the measurement of 3D knee angle during gait in comparison to a reference system were assessed on eight healthy subjects. The new procedure relying on active and passive movements reported a high repeatability of the mean values (offset<1 degrees) and angular patterns (SD<0.3 degrees and CMC>0.9). In comparison to the reference system, this functional procedure showed high precision (SD<2 degrees and CC>0.75) and moderate accuracy (between 4.0 degrees and 8.1 degrees) for the three knee angle. The combination of the inertial-based system with the functional calibration procedure proposed here resulted in a promising tool for the measurement of 3D knee joint angle. Moreover, this method could be adapted to measure other complex joint, such as ankle or elbow.
Resumo:
Path integration is known to provide information to keep track of spatial location. Surprisingly, few investigations concerning sex differences in computation of the traveling distance have been done. This work was aimed at analyzing the reproduction of both passive and active linear displacements in women and men. To this end, the displacement of blindfolded subjects was done in a wheelchair, then on foot, three times in each condition for a fixed distance. Copies of passive and active traveling distance, distance estimations and pointing responses towards the starting point were analyzed. In passive condition and comparatively to men, women error was larger. Whereas traveling distance was generally underestimated in women, it was overestimated in men. In active condition, no sex differences were observed. When blindfolded subjects have to estimate the traveling distance, the female error was larger than the male one. But, when subjects were asked to indicate the visual cue corresponding to the traveling distance, the male error was larger than the female one. Finally, pointing to the starting point (0°) after a whole-body rotation showed a larger deviation from 0° in men than in women. These results suggest that sex of the subjects influence brain computation of path integration information.
Resumo:
Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data. After one year of use, the volumetric wear was 8.4 mm(3) for the anatomical prosthesis, but 44.6 mm(3) for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.
Resumo:
BACKGROUND: We sought to investigate the relationship between infarct and dyssynchrony post- myocardial infarct (MI), in a porcine model. Mechanical dyssynchrony post-MI is associated with left ventricular (LV) remodeling and increased mortality. METHODS: Cine, gadolinium-contrast, and tagged cardiovascular magnetic resonance (CMR) were performed pre-MI, 9 ± 2 days (early post-MI), and 33 ± 10 days (late post-MI) post-MI in 6 pigs to characterize cardiac morphology, location and extent of MI, and regional mechanics. LV mechanics were assessed by circumferential strain (eC). Electro-anatomic mapping (EAM) was performed within 24 hrs of CMR and prior to sacrifice. RESULTS: Mean infarct size was 21 ± 4% of LV volume with evidence of post-MI remodeling. Global eC significantly decreased post MI (-27 ± 1.6% vs. -18 ± 2.5% (early) and -17 ± 2.7% (late), p < 0.0001) with no significant change in peri-MI and MI segments between early and late time-points. Time to peak strain (TTP) was significantly longer in MI, compared to normal and peri-MI segments, both early (440 ± 40 ms vs. 329 ± 40 ms and 332 ± 36 ms, respectively; p = 0.0002) and late post-MI (442 ± 63 ms vs. 321 ± 40 ms and 355 ± 61 ms, respectively; p = 0.012). The standard deviation of TTP in 16 segments (SD16) significantly increased post-MI: 28 ± 7 ms to 50 ± 10 ms (early, p = 0.012) to 54 ± 19 ms (late, p = 0.004), with no change between early and late post-MI time-points (p = 0.56). TTP was not related to reduction of segmental contractility. EAM revealed late electrical activation and greatly diminished conduction velocity in the infarct (5.7 ± 2.4 cm/s), when compared to peri-infarct (18.7 ± 10.3 cm/s) and remote myocardium (39 ± 20.5 cm/s). CONCLUSIONS: Mechanical dyssynchrony occurs early after MI and is the result of delayed electrical and mechanical activation in the infarct.
Resumo:
Total shoulder arthroplasty (TSA) is an accepted and most successfully used treatment for different shoulder pathologies. Different risk factors for the failure of the prosthesis are known. A pathological scapular orientation, observed in elderly people or in patients suffering from neuromuscular diseases, could be a cause of failure, which has not been investigated yet. To test this hypothesis, a numerical musculoskeletal model of the glenohumeral joint was used to compare two TSA cases: a reference normal case and a case with a pathological anterior tilt of the scapula. An active abduction of 150° was simulated. Joint force, contact pattern, polyethylene and cement stress were evaluated for both cases. The pathological tilt slightly increased the joint force and the contact pressure, but also shifted the contact pattern. This eccentric contact increased the stress level within the polyethylene of the glenoid component and within the surrounding cement layer. This adverse effect occurred mainly during the first 60° of abduction. Therefore, a pathological orientation of the scapula may increase the risk of a failure of the cement layer around the glenoid component. These preliminary numerical results should be confirmed by a clinical study.
Resumo:
In the present review, microvascular remodelling refers to alterations in the structure of resistance vessels contributing to elevated systemic vascular resistance in hypertension. We start with some historical aspects, underscoring the importance of Folkow's contribution made half a century ago. We then move to some basic concepts on the biomechanics of blood vessels, and explicit the definitions proposed by Mulvany for specific forms of remodelling, especially inward eutrophic and inward hypertrophic. The available evidence for the existence of remodelled resistance vessels in hypertension comes next, with relatively more weight given to human, in comparison with animal data. Mechanisms are discussed. The impact of antihypertensive drug treatment on remodelling is described, again with emphasis on human data. Some details are given on the three studies to date which point to remodelling of subcutaneous resistance arteries as an independent predictor of cardiovascular risk in hypertensive patients. We terminate by considering the potential role of remodelling in the pathogenesis of end-organ damage and in the perpetuation of hypertension.
Resumo:
BACKGROUND: Chronic lateral ankle instability accounts for 20% of the ankle injuries. This study evaluates functional outcome of the modified Broström-Gould technique using suture anchors, with 4 different clinical scores. METHODS: A consecutive series of 41 patients were included with a minimum follow-up of one year. The function was assessed using 4 clinical scores including: the AOFAS for hind foot; the FAAM; the CAIT and the CAIS. RESULTS: Out of 41 patients; 27 patients were very satisfied, 11 satisfied and 3 were not satisfied. Ankle mobility returned to normal in 93% of patients. At follow-up the AOFAS was 89/100 (37-100), the FAAM 85/100% (35-100%), the CAIT 20/30 (5-30), and the CAIS 74/100% (27-100%). CONCLUSION: Outcome of modified Broström-Gould procedure is good with high satisfaction rate in terms of ankle mobility. The disparity in outcome of scores, signals towards the need of a standard evaluation system.
Resumo:
ABSTRACT: Ultramarathons comprise any sporting event involving running longer than the traditional marathon length of 42.195 km (26.2 miles). Studies on ultramarathon participants can investigate the acute consequences of ultra-endurance exercise on inflammation and cardiovascular or renal consequences, as well as endocrine/energetic aspects, and examine the tissue recovery process over several days of extreme physical load. In a study published in BMC Medicine, Schütz et al. followed 44 ultramarathon runners over 4,487 km from South Italy to North Cape, Norway (the Trans Europe Foot Race 2009) and recorded daily sets of data from magnetic resonance imaging, psychometric, body composition and biological measurements. The findings will allow us to better understand the timecourse of degeneration/regeneration of some lower leg tissues such as knee joint cartilage, to differentiate running-induced from age-induced pathologies (for example, retropatelar arthritis) and finally to assess the interindividual susceptibility to injuries. Moreover, it will also provide new information about the complex interplay between cerebral adaptations/alterations and hormonal influences resulting from endurance exercise and provide data on the dose-response relationship between exercise and brain structure/function. Overall, this study represents a unique attempt to investigate the limits of the adaptive response of human bodies.Please see related article: http://www.biomedcentral.com/1741-7015/10/78.
Resumo:
El present projecte s'ha dut a terme a l'American Museum of Natural History (AMNH, New York) entre el 31 de Desembre de 2010 i el 30 de Desembre de 2012. L'objectiu del projecte era elucidar la història evolutiva de la mà humana: traçar els canvis evolutius en la seva forma i proporcions que van propiciar la seva estructura moderna que permet als humans manipular amb precisió. El treball realitzat ha inclòs recol•lecció de dades i anàlisis, redacció de resultats i formació en mètodes analítics específics. Durant aquest temps, l'autor a completat la seva de base de dades existent en mesures lineals de la mà a hominoides. També s'han agafat dades del peu; d'aquesta forma ara mateix es compta amb una base de dades amb més de 500 individus, amb més de 200 mesures per cada un. També s'han agafat dades en tres imensions utilitzant un làser escàner. S'han après tècniques de morfometria geomètrica 3D directament dels pioners al camp a l'AMNH. Com a resultat d'aquesta feina s'han produït 10 resums (publicats a congressos internacionals) i 9 manuscrits (molts d'ells ja publicats a revistes internacionals) amb resultats de gran rellevància: La mà humana posseeix unes proporcions relativament primitives, que són més similars a les proporciones que tenien els hominoides fòssils del Miocè que no pas a la dels grans antropomorfs actuals. Els darrers tenen unes mans allargades amb un polzes molt curts que reflexen l'ús de la mà com a eina de suspensió sota les branques. En canvi, els hominoides del Miocè tenien unes mans relativament curtes amb un polze llarg que feien servir per estabilitzar el seu pes quan caminaven per sobre de les branques. Una vegada els primers homínids van aparèixer al final del Miocè (fa uns 6 Ma) i van començar a fer servir el bipedisme com a mitjà més comú de locomoció, les seves mans van ser "alliberades" de les seves funcions locomotores. La selecció natural—ara només treballant en la manipulació—va convertir les proporcions ja existents de la mà d'aquests primats en l'òrgan manipulatori que representa la mà humana avui dia.
Resumo:
The interfacial micromotion is closely associated to the long-term success of cementless hip prostheses. Various techniques have been proposed to measure them, but only a few number of points over the stem surface can be measured simultaneously. In this paper, we propose a new technique based on micro-Computer Tomography (μCT) to measure locally the relative interfacial micromotions between the metallic stem and the surrounding femoral bone. Tantalum beads were stuck at the stem surface and spread at the endosteal surface. Relative micromotions between the stem and the endosteal bone surfaces were measured at different loading amplitudes. The estimated error was 10μm and the maximal micromotion was 60μm, in the loading direction, at 1400N. This pilot study provided a local measurement of the micromotions in the 3 direction and at 8 locations on the stem surface simultaneously. This technique could be easily extended to higher loads and a much larger number of points, covering the entire stem surface and providing a quasi-continuous distribution of the 3D interfacial micromotions around the stem. The new measurement method would be very useful to compare the induced micromotions of different stem designs and to optimize the primary stability of cementless total hip arthroplasty.
Resumo:
BACKGROUND: The Foot and Ankle Ability Measure (FAAM) is a self reported questionnaire for patients with foot and ankle disorders available in English, German, and Persian. This study plans to translate the FAAM from English to French (FAAM-F) and assess the validity and reliability of this new version.METHODS: The FAAM-F Activities of Daily Living (ADL) and sports subscales were completed by 105 French-speaking patients (average age 50.5 years) presenting various chronic foot and ankle disorders. Convergent and divergent validity was assessed by Pearson's correlation coefficients between the FAAM-F subscales and the SF-36 scales: Physical Functioning (PF), Physical Component Summary (PCS), Mental Health (MH) and Mental Component Summary (MCS). Internal consistency was calculated by Cronbach's Alpha (CA). To assess test re-test reliability, 22 patients filled out the questionnaire a second time to estimate minimal detectable changes (MDC) and intraclass correlation coefficients (ICC).RESULTS: Correlations for FAAM-F ADL subscale were 0.85 with PF, 0.81 with PCS, 0.26 with MH, 0.37 with MCS. Correlations for FAAM-F Sports subscale were 0.72 with PF, 0.72 with PCS, 0.21 with MH, 0.29 with MCS. CA estimates were 0.97 for both subscales. Respectively for the ADL and Sports subscales, ICC were 0.97 and 0.94, errors for a single measure were 8 and 10 points at 95% confidence and the MDC values at 95% confidence were 7 and 18 points.CONCLUSION: The FAAM-F is valid and reliable for the self-assessment of physical function in French-speaking patients with a wide range of chronic foot and ankle disorders.