906 resultados para Electrical bias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To measure cutaneous electrical nociceptive thresholds in relation to known thermal and mechanical stimulation for nociceptive threshold detection in cats.Study design Prospective, blinded, randomized cross-over study with 1-week washout interval.Animals Eight adult cats [bodyweight 5.1 +/- 1.8 kg (mean + SD)].Methods Mechanical nociceptive thresholds were tested using a step-wise manual inflation of a modified blood pressure bladder attached to the cat's thoracic limb. Thermal nociceptive thresholds were measured by increasing the temperature of a probe placed on the thorax. The electrical nociceptive threshold was tested using an escalating current from a constant current generator passed between electrodes placed on the thoracic region. A positive response (threshold) was recorded when cats displayed any or all of the following behaviors: leg shake, head turn, avoidance, or vocalization. Four baseline readings were performed before intramuscular injection of meperidine (5 mg kg(-1)) or an equal volume of saline. Threshold recordings with each modality were made at 15, 30, 45, 60, 90, and 120 minutes post-injection. Data were analyzed using ANOVA and paired t-tests (significance at p < 0.05).Results There were no significant changes in thermal, mechanical, or electrical thresholds after saline. Thermal thresholds increased at 15-60 minutes (p < 0.01) and mechanical threshold increased at 30 and 45 minutes after meperidine (p < 0.05). Maximum thermal threshold was +4.1 +/- 0.3 degrees C above baseline at 15 minutes while maximum mechanical threshold was 296 +/- 265 mmHg above baseline at 30 minutes after meperidine. Electrical thresholds following meperidine were not significantly different than baseline (p > 0.05). Thermal and electrical thresholds after meperidine were significantly higher than saline at 30 and 45 minutes (p < 0.05), and at 120 minutes (p < 0.05), respectively. Mechanical thresholds were significantly higher than saline treatment at 30 minutes (p <= 0.05).Conclusion and clinical relevance Electrical stimulation did not detect meperidine analgesia whereas both thermal and mechanical thresholds changed after meperidine administration in cats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the work was to study the effect of milking fraction on electrical conductivity of milk (EC) to improve its use in dairy goat mastitis detection using automatic EC measurements during milking. The experiment was carried out on a group of 84 Murciano-Granadina goats (28 primiparous and 56 multiparous). Goats were in the fourth month of lactation. A linear mixed model was used to analyse the relationship between EC or somatic cell count (SCC) of gland milk and parity, mammary gland health status, analysed fraction (first 100 mL=F-1; machine milk=F-2; and stripping milk=F-3) and their first order interactions. Additionally, the mastitis detection characteristics (sensitivity, specificity, positive predictive value and negative predictive value) of SCC and EC were studied at different thresholds.All factors considered were significant for EC and SCC. EC decreased significantly as milking progressed (from F-1 to F-3) in both healthy and infected glands. EC was not significantly different between healthy and infected glands in F-1 and F-2 fractions, but EC of healthy glands (5.01 mS/cm) was significantly lower than in infected glands (5.03 mS/cm) at F-3.Mastitis detection characteristics of EC did not differ amongst studied fractions. The small significant difference of EC between healthy and infected glands obtained in F-3 fraction did not yield better sensitivity results compared to F-1 and F-2. The best EC mastitis detection characteristics were obtained at 5.20 mS/cm threshold (sensitivity of 70% and specificity of 50%). The best SCC mastitis detection characteristics were obtained at 300,000 cells/mL threshold and F-3 fraction (sensitivity of 85% and specificity of 65%).It was concluded that mastitis detection characteristics of EC were similar in the three milking fractions analysed, being slightly better for SCC in F-3 fraction. As shown in previous studies, there are no factors other than the mammary gland health status that affect milk EC and should be considered in the algorithms for mastitis detection to improve the results. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated possible publication bias and its related factors in implant-related research over time. Materials and Methods: Articles published in Clinical Implant Dentistry and Related Research, Clinical Oral Implants Research, Implant Dentistry, Journal of Oral Implantology, and The International Journal of Oral & Maxillofacial Implants between 2005 and 2009 were reviewed. Nonoriginal articles were excluded. For each article included, study outcome, extramural funding source, type of study, and geographic origin were recorded. Descriptive and analytic statistics (alpha = .05), including the chi-square test and logistic regression analysis, were performed where appropriate. Results: From a total of 2,085 articles, 1,503 met the inclusion criteria. of the articles analyzed, 1,226 (81.6%), 160 (10.6%), and 117 (7.8%) articles reported positive, negative, and neutral outcomes, respectively. In vitro studies, studies from Asia, and funded animal studies were more likely to report positive outcomes compared to others (P = .02, P < .0001, and P = .009, respectively). Industry-funded studies represented the lowest frequency of positive outcomes versus studies funded by other sources. Conclusions: There were a high number of implant-related studies reporting positive outcomes in the five selected journals. Some selected factors were associated with positive outcome bias. In general, funding was not associated with a positive outcome, except for animal studies. Industry-supported research did not show any association with the publication of positive outcomes. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:1024-1032

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (mu V). The results, which were assessed using analysis of variance (ANOVA) to a 5% significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to demonstrate how the chemical homogeneity of B cations affects the microstructure and electrical responses of (1-x) PMN-xPT ceramics. Two methodologies were employed to synthesize three different compositions, with x assuming the values 0.10, 0.28, and 0.35. If compared to conventional method, the Ti-modified columbite route, which is characterized by higher B cation homogeneity, leads to PMN-PT powders and ceramics with lower content of PNT pyrochlore phase and, for 0.65PMN-0.35PT composition, minor amount of tetragonal phase is found. Conclusively, PMN-PT ceramics obtained by modified route favors B cations homogeneity, enhancing the dielectric, ferroelectric and piezoelectric properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural effects of lithium additive on 0.9PMN-0.1PT powders prepared by Ti-modified columbite route were studied. The substitution of Li+ ions for Mg2+ ions in the B-site sub-lattice of 0.9PMN-0.1PT perovskite structure was explained in terms of lead and oxygen vacancies generation originated as consequence of the ionic compensation of negatively charged Li'(Mg) sites. The rise in mass transport as consequence of the increasing of Pb2+ and O2- vacancies produces more agglomerated particles during the powder synthesis and changes the mechanical characteristics between grain and grain boundary of sintered ceramic. The relation between K-m and T-m values, the difference between ionic radii of B cation and the molar volume were used to explain the changes in the relaxor behavior and diffusiveness of phase transition as function of lithium doping, which are corroborated by the results obtained through the ferroelectric characterization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the influence an abdominal support attached to a traditional stool, of those used by dentists, has on the body's distribution of the electrical activity of the superior trapezius and the longissimus thoracic muscles of dental students during the execution of a clinical procedure. The results showed no significant difference in the body's distribution in the seat and backrest, but did reveal there was a weight discharge of 3.1 +/- 1.9% of dentist's body weight in the abdominal support. The 9 o'clock position proved to be the best position to perform clinical procedures. It was also observed that the position was closer to the body's axis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour of dc longitudinal and transverse conductivity in self-assembled plastdoped films of polyaniline has been studied over the range of 9 K to 320 K, under different applied mechanical pressures. We observe a progressive evolution of the conductivity picture as the applied pressure is increased, especially in the transverse direction, where the conductivity tends to lower as the pressure is increased. (C) 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thermal dependence of the zero-bias conductance for the single electron transistor is the target of two independent renormalization-group approaches, both based on the spin-degenerate Anderson impurity model. The first approach, an analytical derivation, maps the Kondo-regime conductance onto the universal conductance function for the particle-hole symmetric model. Linear, the mapping is parametrized by the Kondo temperature and the charge in the Kondo cloud. The second approach, a numerical renormalization-group computation of the conductance as a function the temperature and applied gate voltages offers a comprehensive view of zero-bias charge transport through the device. The first approach is exact in the Kondo regime; the second, essentially exact throughout the parametric space of the model. For illustrative purposes, conductance curves resulting from the two approaches are compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tin dioxide varistors doped with Coo, ZnO, Ta2O5 and Cr2O3 were prepared by the mixed oxide method. Temperature dependent impedance spectroscopy revealed two different activation energies, one at low frequencies and the other at high frequencies. These activation energies were associated with the adsorption and reaction of O-2 species at the grain boundary interface. We show that Cr2O3 improves the varistor properties, generating sites for the adsorption of O' and O at the grain boundary region. The O' and O defects are truly responsible for the barrier formation at the grain boundary interface. (c) 2005 Elsevier Ltd and Techna Group S.r.l. All rights reserved.