984 resultados para Continuous monitoring with Polarographic Oxygen Sensor
Resumo:
The Iowa Department of Transportation research project HR-1013 is the evaluation of a prototype continuous monitoring nuclear density unit. The Unit, the Consolidation Monitoring Device (CMD), mounts on the rear of a slip-form paver and measures the density of the concrete while still in the plastic state. The evaluation performed determined the usefulness, accuracy, precision and reproducibility of the unit. The CMD was calibrated and tested in the laboratory for one week before field evaluation. The field evaluation consisted of monitoring at least 5 miles of paving and then correlating the CMD data with two conventional density methods. The two supplemental methods were density measurement with a Troxler nuclear gauge and densities obtained from core samples.
Resumo:
OBJECTIVES: We have sought to develop an automated methodology for the continuous updating of optimal cerebral perfusion pressure (CPPopt) for patients after severe traumatic head injury, using continuous monitoring of cerebrovascular pressure reactivity. We then validated the CPPopt algorithm by determining the association between outcome and the deviation of actual CPP from CPPopt. DESIGN: Retrospective analysis of prospectively collected data. SETTING: Neurosciences critical care unit of a university hospital. PATIENTS: A total of 327 traumatic head-injury patients admitted between 2003 and 2009 with continuous monitoring of arterial blood pressure and intracranial pressure. MEASUREMENTS AND MAIN RESULTS: Arterial blood pressure, intracranial pressure, and CPP were continuously recorded, and pressure reactivity index was calculated online. Outcome was assessed at 6 months. An automated curve fitting method was applied to determine CPP at the minimum value for pressure reactivity index (CPPopt). A time trend of CPPopt was created using a moving 4-hr window, updated every minute. Identification of CPPopt was, on average, feasible during 55% of the whole recording period. Patient outcome correlated with the continuously updated difference between median CPP and CPPopt (chi-square=45, p<.001; outcome dichotomized into fatal and nonfatal). Mortality was associated with relative "hypoperfusion" (CPP<CPPopt), severe disability with "hyperperfusion" (CPP>CPPopt), and favorable outcome was associated with smaller deviations of CPP from the individualized CPPopt. While deviations from global target CPP values of 60 mm Hg and 70 mm Hg were also related to outcome, these relationships were less robust. CONCLUSIONS: Real-time CPPopt could be identified during the recording time of majority of the patients. Patients with a median CPP close to CPPopt were more likely to have a favorable outcome than those in whom median CPP was widely different from CPPopt. Deviations from individualized CPPopt were more predictive of outcome than deviations from a common target CPP. CPP management to optimize cerebrovascular pressure reactivity should be the subject of future clinical trial in severe traumatic head-injury patients.
Resumo:
PURPOSE OF REVIEW: An important goal of neurocritical care is the management of secondary brain injury (SBI), that is pathological events occurring after primary insult that add further burden to outcome. Brain oedema, cerebral ischemia, energy dysfunction, seizures and systemic insults are the main components of SBI. We here review recent data showing the clinical utility of brain multimodality monitoring (BMM) for the management of SBI. RECENT FINDINGS: Despite being recommended by international guidelines, standard intracranial pressure (ICP) monitoring may be insufficient to detect all episodes of SBI. ICP monitoring, combined with brain oxygen (PbtO(2)), cerebral microdialysis and regional cerebral blood flow, might help to target therapy (e.g. management of cerebral perfusion pressure, blood transfusion, glucose control) to patient-specific pathophysiology. Physiological parameters derived from BMM, including PbtO(2) and microdialysis lactate/pyruvate ratio, correlate with outcome and have recently been incorporated into neurocritical care guidelines. Advanced intracranial devices can be complemented by quantitative electroencephalography to monitor changes of brain function and nonconvulsive seizures. SUMMARY: BMM offers an on-line comprehensive scrutiny of the injured brain and is increasingly used for the management of SBI. Integration of monitored data using new informatics tools may help optimize therapy of brain-injured patients and quality of care.
Resumo:
Objectives: To assess the difference in direct medical costs between on-demand (OD) treatment with esomeprazole (E) 20 mg and continuous (C) treatment with E 20 mg q.d. from a clinical practice view in patients with gastroesophageal reflux disease (GERD) symptoms. Methods: This open, randomized study (ONE: on-demand Nexium evaluation) compared two long-term management options with E 20 mg in endoscopically uninvestigated patients seeking primary care for GERD symptoms who demonstrated complete relief of symptoms after an initial treatment of 4 weeks with E 40 mg. Data on consumed quantities of all cost items were collected in the study, while data on prices during the time of study were collected separately. The analysis was done from a societal perspective. Results: Forty-nine percent (484 of 991) of patients randomized to the OD regimen and 46% (420 of 913) of the patients in the C group had at least one contact with the investigator that would have occurred nonprotocol-driven. The difference of the adjusted mean direct medical costs between the treatment groups was CHF 88.72 (95% confidence interval: CHF 41.34-153.95) in favor of the OD treatment strategy (Wilcoxon rank-sum test: P < 0.0001). Adjusted direct nonmedical costs and productivity loss were similar in both groups. Conclusions: The adjusted direct medical costs of a 6-month OD treatment with esomeprazole 20 mg in uninvestigated patients with symptoms of GERD were significantly lower compared with a continuous treatment with E 20 mg once a day. The OD therapy represents a cost-saving alternative to the continuous treatment strategy with E.
Resumo:
Background: It is unknown whether cerebral perfusion in geriatric and younger patients under general anaesthesia differs. Methods: We compared 2 groups of patients undergoing elective major non-cardiac surgery under standardized general anaesthesia (thiopental, sevoflurane, fentanyl, atracurium). Group 1: 18-40 yrs (n = 20), Group 2: >65 yrs (n = 37). Cerebral perfusion was investigated with transcranial Doppler and near-infrared spectroscopy (NIRS). Arterial blood pressure was monitored continuously with a Finapres device. Mx, an index allowing continuous monitoring of cerebrovascular autoregulation based on the changes in mean arterial blood pressure (MAP) and cerebral blood flow velocity was calculated. Data are shown as mean } SD. Results: MAP (86 } 9.6 vs 79 } 10.9 mm Hg, p = 0.02), end-tidal concentration of sevoflurane (1.9 } 0.3 vs 1.6 } 0.3%, p <0.01), and the cerebral tissue oxygenation index measured by NIRS (72 } 4 vs 68 } 5%, p = 0.01), were significantly lower in Group 2. The end-tidal concentration of O2 was significantly higher in Group 2 (46 } 4 vs 48 } 4% p = 0.04). There were no significant differences between Group 1 and 2 for cerebral blood flow velocity (41 } 10 vs 43 } 18 cm/s), end tidal CO2 (4.7 } 0.3 vs 4.6 } 0.3 kPa) and cerebrovascular autoregulation (Mx 0.42 } 0.2 vs 0.48 } 0.2). In Group 1 35% and in Group 2 43% of the patients had an index of autoregulation suggesting disturbed cerebrovascular autoregulation (p = n.s.). Conclusions: In elderly patients under general anaesthesia with sevoflurane the cerebral tissue oxygenation index was significantly lower than in younger patients despite higher end-tidal oxygen concentrations. Our data suggest subtle differences in cerebral perfusion between geriatric and younger
Resumo:
OBJECTIVE: To compare the heart-rate monitoring with the doubly labelled water (2H2(18)O) method to estimate total daily energy expenditure in obese and non-obese children. DESIGN: Cross sectional study of obese and normal weight children. SUBJECTS: 13 prepubertal children: six obese (4M, 2F, 9.1 +/- 1.5 years, 47.3 +/- 9.7 kg) and seven non-obese (3M, 4F, 9.3 +/- 0.6 years, 31.8 +/- 3.2 kg). MEASUREMENTS: Total daily energy expenditure was assessed by means of the doubly labelled water method (TEEDLW) and of heart-rate monitoring (TEEHR). RESULTS: TEEHR was significantly (P < 0.05) higher than TEEDLW in obese children (9.47 +/- 0.84 MJ/d vs 8.99 +/- 0.63 MJ/d) whereas it was not different in non-obese children (8.43 +/- 2.02 MJ/d vs 8.42 +/- 2.30 MJ/d, P = NS). The difference of TEE assessed by HR monitoring in the obese group averaged 6.2 +/- 4.7%. At the individual level, the degree of agreement (difference between TEEHR and TEEDLW +/- 2s.d.) was low both in obese (-0.36, 1.32 MJ/d) and in non-obese children (-1.30, 1.34 MJ/d). At the group level, the agreement between the two methods was good in nonobese children (95% c.i. for the bias:-0.59, 0.63 MJ/d) but not in obese children (0.04, 0.92 MJ/d). Duration of sleep and energy expenditure during resting and physical activity were not significantly different in the two groups. Patterns of heart-rate (or derived energy expenditure) during the day-time were similar in obese and non-obese children. CONCLUSION: The HR monitoring technique provides an estimation of TEE close to that assessed by the DLW method in non-obese prepubertal children. In comparison with DLW, the HR monitoring method yields a greater TEE value in obese children.
Resumo:
The objective of this work was to evaluate the total and thermotolerant coliform densities in the oyster culture water of Cananeia, SP, Brazil, correlating these densities with environmental variables and tidal variations. Superficial water samples were collected in two tide conditions (spring and neap) from three areas of Cananéia municipality (Mandira, Itapitangui and Cooperostra). The three studied areas showed good conditions for the culture regarding coliform densities. The two tidal conditions differed significantly as to total coliform concentration; however, the same procedure was not performed for thermotolerant coliforms. No correlation was observed between water temperature, pH, and concentrations of total and thermotolerant coliforms. Coliform density was positively correlated with rainfall and negatively correlated with salinity. Spring and neap tides differed significantly as to coliform number. Simple diagnosis of environmental conditions of the crop fields is insufficient to assess water quality of shellfish cultivation. A continuous monitoring program of planted areas is necessary both for the assessment of water quality potential for marine culture and for ensuring safe consumption of seafood, besides constituting an important tool to understand the relationships between contamination and the involved environmental variables.
Resumo:
We present a viscometric affinity biosensor that can potentially allow continuous multi-analyte monitoring in biological fluids like blood or plasma. The sensing principle is based on the detection of viscosity changes of a polymeric solution which has a selective affinity for the analyte of interest. The chemico-mechanical sensor incorporates an actuating piezoelectric diaphragm, a sensing piezoelectric diaphragm and a flow-resisting microchannel for viscosity detection. A free-standing Anodic Alumina Oxide (AAO) porous nano-membrane is used as selective interface. A glucose-sensitive sensor was fabricated and extensively assessed in buffer solution. The sensor reversibility, stability and sensitivity were excellent during at least 65 hours. Results showed also a good degree of stability for a long term measurement (25 days). The sensor behaviour was furthermore tested in fetal bovine serum (FBS). The obtained results for glucose sensing are very promising, indicating that the developed sensor is a candidate for continuous monitoring in biological fluids. Sensitive solutions for ionized calcium and pH are currently under development and should allow multi-analyte sensing in the near future.
Resumo:
Careful patient monitoring using a variety of techniques including clinical and laboratory evaluation, bedside physiological monitoring with continuous or non-continuous techniques and imaging is fundamental to the care of patients who require neurocritical care. How best to perform and use bedside monitoring is still being elucidated. To create a basic platform for care and a foundation for further research the Neurocritical Care Society in collaboration with the European Society of Intensive Care Medicine, the Society for Critical Care Medicine and the Latin America Brain Injury Consortium organized an international, multidisciplinary consensus conference to develop recommendations about physiologic bedside monitoring. This supplement contains a Consensus Summary Statement with recommendations and individual topic reviews as a background to the recommendations. In this article, we highlight the recommendations and provide additional conclusions as an aid to the reader and to facilitate bedside care.
Resumo:
In this study, the evaluation of the accuracy and performance of a light detection and ranging (LIDAR) sensor for vegetation using distance and reflection measurements aiming to detect and discriminate maize plants and weeds from soil surface was done. The study continues a previous work carried out in a maize field in Spain with a LIDAR sensor using exclusively one index, the height profile. The current system uses a combination of the two mentioned indexes. The experiment was carried out in a maize field at growth stage 12–14, at 16 different locations selected to represent the widest possible density of three weeds: Echinochloa crus-galli (L.) P.Beauv., Lamium purpureum L., Galium aparine L.and Veronica persica Poir.. A terrestrial LIDAR sensor was mounted on a tripod pointing to the inter-row area, with its horizontal axis and the field of view pointing vertically downwards to the ground, scanning a vertical plane with the potential presence of vegetation. Immediately after the LIDAR data acquisition (distances and reflection measurements), actual heights of plants were estimated using an appropriate methodology. For that purpose, digital images were taken of each sampled area. Data showed a high correlation between LIDAR measured height and actual plant heights (R2 = 0.75). Binary logistic regression between weed presence/absence and the sensor readings (LIDAR height and reflection values) was used to validate the accuracy of the sensor. This permitted the discrimination of vegetation from the ground with an accuracy of up to 95%. In addition, a Canonical Discrimination Analysis (CDA) was able to discriminate mostly between soil and vegetation and, to a far lesser extent, between crop and weeds. The studied methodology arises as a good system for weed detection, which in combination with other principles, such as vision-based technologies, could improve the efficiency and accuracy of herbicide spraying.
Resumo:
Data management consists of collecting, storing, and processing the data into the format which provides value-adding information for decision-making process. The development of data management has enabled of designing increasingly effective database management systems to support business needs. Therefore as well as advanced systems are designed for reporting purposes, also operational systems allow reporting and data analyzing. The used research method in the theory part is qualitative research and the research type in the empirical part is case study. Objective of this paper is to examine database management system requirements from reporting managements and data managements perspectives. In the theory part these requirements are identified and the appropriateness of the relational data model is evaluated. In addition key performance indicators applied to the operational monitoring of production are studied. The study has revealed that the appropriate operational key performance indicators of production takes into account time, quality, flexibility and cost aspects. Especially manufacturing efficiency has been highlighted. In this paper, reporting management is defined as a continuous monitoring of given performance measures. According to the literature review, the data management tool should cover performance, usability, reliability, scalability, and data privacy aspects in order to fulfill reporting managements demands. A framework is created for the system development phase based on requirements, and is used in the empirical part of the thesis where such a system is designed and created for reporting management purposes for a company which operates in the manufacturing industry. Relational data modeling and database architectures are utilized when the system is built for relational database platform.
Resumo:
Encapsulated specialty oils commercialized in São Paulo state, Brazil, were evaluated for their identity (fatty acids profile) and compliance with nutrition labeling (fatty acids and Vitamin E (alpha tocopherol) contents). Twenty one samples [flaxseed oil (6), evening primrose (5), safflower (8), borage (1), and black currant (1)] purchased from local markets or collected by the health surveillance agency were analyzed. The fatty acids and vitamin E contents were analyzed by gas chromatography with flame ionization detector and liquid chromatography with UV detector, respectively. Nine samples were adulterated (5 samples of safflower oil, 3 of flaxseed oil, and one of evening primrose). Among them, 3 flaxseed and 2 safflower oil samples were probably adulterated by the addition of soybean oil. Conjugated linoleic acid (CLA) was found in two safflower oils samples although the sale of oils with conjugated linoleic acid (CLA) is not permitted by the National Health Surveillance Agency in Brazil (ANVISA). Only two samples presented all values in compliance with nutrition labeling (one safflower oil sample and one borage oil sample). The results show that a continuous monitoring of encapsulated specialty oils commercialized in Brazil is necessary including a greater number of samples and sanitary surveillance.
Resumo:
L’érosion éolienne est un problème environnemental parmi les plus sévères dans les régions arides, semi-arides et les régions sèches sub-humides de la planète. L’érosion des sols accélérée par le vent provoque des dommages à la fois localement et régionalement. Sur le plan local, elle cause la baisse des nutriments par la mobilisation des particules les plus fines et de la matière organique. Cette mobilisation est une des causes de perte de fertilité des sols avec comme conséquence, une chute de la productivité agricole et une réduction de la profondeur de la partie arable. Sur le plan régional, les tempêtes de poussières soulevées par le vent ont un impact non négligeable sur la santé des populations, et la déposition des particules affecte les équipements hydrauliques tels que les canaux à ciel ouvert ainsi que les infrastructures notamment de transport. Dans les régions où les sols sont fréquemment soumis à l’érosion éolienne, les besoins pour des études qui visent à caractériser spatialement les sols selon leur degré de vulnérabilité sont grands. On n’a qu’à penser aux autorités administratives qui doivent décider des mesures à prendre pour préserver et conserver les potentialités agropédologiques des sols, souvent avec des ressources financières modestes mises à leur disposition. Or, dans certaines de ces régions, comme notre territoire d’étude, la région de Thiès au Sénégal, ces études font défaut. En effet, les quelques études effectuées dans cette région ou dans des contextes géographiques similaires ont un caractère plutôt local et les approches suivies (modèles de pertes des sols) nécessitent un nombre substantiel de données pour saisir la variabilité spatiale de la dynamique des facteurs qui interviennent dans le processus de l’érosion éolienne. La disponibilité de ces données est particulièrement problématique dans les pays en voie de développement, à cause de la pauvreté en infrastructures et des problèmes de ressources pour le monitoring continu des variables environnementales. L’approche mise de l’avant dans cette recherche vise à combler cette lacune en recourant principalement à l’imagerie satellitale, et plus particulièrement celle provenant des satellites Landsat-5 et Landsat-7. Les images Landsat couvrent la presque totalité de la zone optique du spectre exploitable par télédétection (visible, proche infrarouge, infrarouge moyen et thermique) à des résolutions relativement fines (quelques dizaines de mètres). Elles permettant ainsi d’étudier la distribution spatiale des niveaux de vulnérabilité des sols avec un niveau de détails beaucoup plus fin que celui obtenu avec des images souvent utilisées dans des études environnementales telles que AVHRR de la série de satellites NOAA (résolution kilométrique). De plus, l’archive complet des images Landsat-5 et Landsat-7 couvrant une période de plus de 20 ans est aujourd’hui facilement accessible. Parmi les paramètres utilisés dans les modèles d’érosion éolienne, nous avons identifiés ceux qui sont estimables par l’imagerie satellitale soit directement (exemple, fraction du couvert végétal) soit indirectement (exemple, caractérisation des sols par leur niveau d’érodabilité). En exploitant aussi le peu de données disponibles dans la région (données climatiques, carte morphopédologique) nous avons élaboré une base de données décrivant l’état des lieux dans la période de 1988 à 2002 et ce, selon les deux saisons caractéristiques de la région : la saison des pluies et la saison sèche. Ces données par date d’acquisition des images Landsat utilisées ont été considérées comme des intrants (critères) dans un modèle empirique que nous avons élaboré en modulant l’impact de chacun des critères (poids et scores). À l’aide de ce modèle, nous avons créé des cartes montrant les degrés de vulnérabilité dans la région à l’étude, et ce par date d’acquisition des images Landsat. Suite à une série de tests pour valider la cohérence interne du modèle, nous avons analysé nos cartes afin de conclure sur la dynamique du processus pendant la période d’étude. Nos principales conclusions sont les suivantes : 1) le modèle élaboré montre une bonne cohérence interne et est sensible aux variations spatiotemporelles des facteurs pris en considération 2); tel qu’attendu, parmi les facteurs utilisés pour expliquer la vulnérabilité des sols, la végétation vivante et l’érodabilité sont les plus importants ; 3) ces deux facteurs présentent une variation importante intra et inter-saisonnière de sorte qu’il est difficile de dégager des tendances à long terme bien que certaines parties du territoire (Nord et Est) aient des indices de vulnérabilité forts, peu importe la saison ; 4) l’analyse diachronique des cartes des indices de vulnérabilité confirme le caractère saisonnier des niveaux de vulnérabilité dans la mesure où les superficies occupées par les faibles niveaux de vulnérabilité augmentent en saison des pluies, donc lorsque l’humidité surfacique et la végétation active notamment sont importantes, et décroissent en saison sèche ; 5) la susceptibilité, c’est-à-dire l’impact du vent sur la vulnérabilité est d’autant plus forte que la vitesse du vent est élevée et que la vulnérabilité est forte. Sur les zones où la vulnérabilité est faible, les vitesses de vent élevées ont moins d’impact. Dans notre étude, nous avons aussi inclus une analyse comparative entre les facteurs extraits des images Landsat et celles des images hyperspectrales du satellite expérimental HYPERION. Bien que la résolution spatiale de ces images soit similaire à celle de Landsat, les résultats obtenus à partir des images HYPERION révèlent un niveau de détail supérieur grâce à la résolution spectrale de ce capteur permettant de mieux choisir les bandes spectrales qui réagissent le plus avec le facteur étudié. Cette étude comparative démontre que dans un futur rapproché, l’amélioration de l’accessibilité à ce type d’images permettra de raffiner davantage le calcul de l’indice de vulnérabilité par notre modèle. En attendant cette possibilité, on peut de contenter de l’imagerie Landsat qui offre un support d’informations permettant tout de même d’évaluer le niveau de fragilisation des sols par l’action du vent et par la dynamique des caractéristiques des facteurs telles que la couverture végétale aussi bien vivante que sénescente.
Resumo:
A simple, effective and inexpensive fiber optic sensor for investigating the setting characteristics of various grades of cement is described. A finite length of unsheathed multimode optical fiber laid inside the cement mix, is subjected to stress during the setting process. The microbends created on the fiber due to this stress directly influence the intensity of light propagating through the fiber. Continuous monitoring of such variations in the light output transmitted through the fiber gives a clear measure of the setting characteristics of the cement mix, thus providing a simple and elegant technique of great practical importance in the field of civil engineering. The smart fiber optic sensor described above can be incorporated into a building during the construction process itself so that continuous monitoring of the deterioration process for the entire life time of the building can be carried out.
Resumo:
The evolution of wireless sensor network technology has enabled us to develop advanced systems for real time monitoring. In the present scenario wireless sensor networks are increasingly being used for precision agriculture. The advantages of using wireless sensor networks in agriculture are distributed data collection and monitoring, monitor and control of climate, irrigation and nutrient supply. Hence decreasing the cost of production and increasing the efficiency of production.This paper describes the application of wireless sensor network for crop monitoring in the paddy fields of kuttand, a region of Kerala, the southern state of India.