909 resultados para visual sensitivity
Resumo:
PURPOSE: To examine the basis of previous findings of an association between indices of driving safety and visual motion sensitivity and to examine whether this association could be explained by low-level changes in visual function. METHODS: 36 visually normal participants (aged 19 – 80 years), completed a battery of standard vision tests including visual acuity, contrast sensitivity and automated visual fields. and two tests of motion perception including sensitivity for movement of a drifting Gabor stimulus, and sensitivity for displacement in a random-dot kinematogram (Dmin). Participants also completed a hazard perception test (HPT) which measured participants’ response times to hazards embedded in video recordings of real world driving which has been shown to be linked to crash risk. RESULTS: Dmin for the random-dot stimulus ranged from -0.88 to -0.12 log minutes of arc, and the minimum drift rate for the Gabor stimulus ranged from 0.01 to 0.35 cycles per second. Both measures of motion sensitivity significantly predicted response times on the HPT. In addition, while the relationship involving the HPT and motion sensitivity for the random-dot kinematogram was partially explained by the other visual function measures, the relationship with sensitivity for detection of the drifting Gabor stimulus remained significant even after controlling for these variables. CONCLUSION: These findings suggest that motion perception plays an important role in the visual perception of driving-relevant hazards independent of other areas of visual function and should be further explored as a predictive test of driving safety. Future research should explore the causes of reduced motion perception in order to develop better interventions to improve road safety.
Resumo:
Purpose To determine the prevalence of falls in the 12 months prior to cataract surgery and examine the associations between visual and other risk factors and falls among older bilateral cataract patients in Vietnam. Methods Data collected from 413 patients in the week before scheduled cataract surgery included a questionnaire and three objective visual tests. Results The outcome of interest was self-reported falls in the previous 12 months. A total of 13% (n = 53) of bilateral cataract patients reported 60 falls within the previous 12 months. After adjusting for age, sex, race, employment status, comorbidities, medication usage, refractive management, living status and the three objective visual tests in the worse eye, women (odds ratio, OR, 4.64, 95% confidence interval, CI, 1.85–11.66), and those who lived alone (OR 4.51, 95% CI 1.44–14.14) were at increased risk of a fall. Those who reported a comorbidity were at decreased risk of a fall (OR 0.43, 95% CI 0.19–0.95). Contrast sensitivity (OR 0.31, 95% CI 0.10–0.95) was the only significant visual test associated with a fall. These results were similar for the better eye, except the presence of a comorbidity was not significant (OR 0.45, 95% CI 0.20–1.02). Again, contrast sensitivity was the only significant visual factor associated with a fall (OR 0.15, 95% CI 0.04–0.53). Conclusion Bilateral cataract patients in Vietnam are potentially at high risk of falls and in need of falls prevention interventions. It may also be important for ophthalmologists and health professionals to consider contrast sensitivity measures when prioritizing cataract patients for surgery and assessing their risk of falls.
Resumo:
We studied the effect of rod–cone interactions on mesopic visual reaction time (RT). Rod and cone photoreceptor excitations were independently controlled using a four-primary photostimulator. It was observed that (1) lateral rod–cone interactions increase the cone-mediated RTs; (2) the rod–cone interactions are strongest when rod sensitivity is maximal in a dark surround, but weaker with increased rod activity in a light surround; and (3) the presence of a dark surround nonselectively increased the mean and variability of chromatic (+L-M, S-cone) and luminance (L+M+S) RTs independent of the level of rod activity. The results demonstrate that lateral rod–cone interactions must be considered when deriving mesopic luminous efficiency using RT.
Resumo:
Purpose We designed a visual field test focused on the field utilized while driving to examine associations between field impairment and motor vehicle collision involvement in 2,000 drivers ≥70 years old. Methods The "driving visual field test" involved measuring light sensitivity for 20 targets in each eye, extending 15° superiorly, 30° inferiorly, 60° temporally and 30° nasally. The target locations were selected on the basis that they fell within the field region utilized when viewing through the windshield of a vehicle or viewing the dashboard while driving. Monocular fields were combined into a binocular field based on the more sensitive point from each eye. Severe impairment in the overall field or a region was defined as average sensitivity in the lowest quartile of sensitivity. At-fault collision involvement for five years prior to enrollment was obtained from state records. Poisson regression was used to calculate crude and adjusted rate ratios examining the association between field impairment and at-fault collision involvement. Results Drivers with severe binocular field impairment in the overall driving visual field had a 40% increased rate of at-fault collision involvement (RR 1.40, 95%CI 1.07-1.83). Impairment in the lower and left fields was associated with elevated collision rates (RR 1.40 95%CI 1.07-1.82 and RR 1.49, 95%CI 1.15-1.92, respectively), whereas impairment in the upper and right field regions was not. Conclusions Results suggest that older drivers with severe impairment in the lower or left region of the driving visual field are more likely to have a history of at-fault collision involvement.
Resumo:
Purpose To quantify the effects of driver age on night-time pedestrian conspicuity, and to determine whether individual differences in visual performance can predict drivers' ability to recognise pedestrians at night. Methods Participants were 32 visually normal drivers (20 younger: M = 24.4 years ± 6.4 years; 12 older: M = 72.0 years ± 5.0 years). Visual performance was measured in a laboratory-based testing session including visual acuity, contrast sensitivity, motion sensitivity and the useful field of view. Night-time pedestrian recognition distances were recorded while participants drove an instrumented vehicle along a closed road course at night; to increase the workload of drivers, auditory and visual distracter tasks were presented for some of the laps. Pedestrians walked in place, sideways to the oncoming vehicles, and wore either a standard high visibility reflective vest or reflective tape positioned on the movable joints (biological motion). Results Driver age and pedestrian clothing significantly (p < 0.05) affected the distance at which the drivers first responded to the pedestrians. Older drivers recognised pedestrians at approximately half the distance of the younger drivers and pedestrians were recognised more often and at longer distances when they wore a biological motion reflective clothing configuration than when they wore a reflective vest. Motion sensitivity was an independent predictor of pedestrian recognition distance, even when controlling for driver age. Conclusions The night-time pedestrian recognition capacity of older drivers was significantly worse than that of younger drivers. The distance at which drivers first recognised pedestrians at night was best predicted by a test of motion sensitivity.
Resumo:
Our aim was to make a quantitative comparison of the response of the different visual cortical areas to selective stimulation of the two different cone-opponent pathways [long- and medium-wavelength (L/M)- and short-wavelength (S)-cone-opponent] and the achromatic pathway under equivalent conditions. The appropriate stimulus-contrast metric for the comparison of colour and achromatic sensitivity is unknown, however, and so a secondary aim was to investigate whether equivalent fMRI responses of each cortical area are predicted by stimulus contrast matched in multiples of detection threshold that approximately equates for visibility, or direct (cone) contrast matches in which psychophysical sensitivity is uncorrected. We found that the fMRI response across the two colour and achromatic pathways is not well predicted by threshold-scaled stimuli (perceptual visibility) but is better predicted by cone contrast, particularly for area V1. Our results show that the early visual areas (V1, V2, V3, VP and hV4) all have robust responses to colour. No area showed an overall colour preference, however, until anterior to V4 where we found a ventral occipital region that has a significant preference for chromatic stimuli, indicating a functional distinction from earlier areas. We found that all of these areas have a surprisingly strong response to S-cone stimuli, at least as great as the L/M response, suggesting a relative enhancement of the S-cone cortical signal. We also identified two areas (V3A and hMT+) with a significant preference for achromatic over chromatic stimuli, indicating a functional grouping into a dorsal pathway with a strong magnocellular input.
Resumo:
Informed by Kristeva's formulation of affect and Winnicott's Holding Environment, this practice-led visual art project is an exploration into how sensitivity to the physical sensation of trembling can sustain a creative practice. Building upon this is a further enquiry into what the significance of the affective experience of trembling is for an ethics of affect in contemporary art. I have done this through object and video-based installations informed by my own experience of trembling. This has been further informed by the work of artists like Louise Bourgeois, Dennis Del Favero and Willie Doherty. The creative outcomes contribute to the discourse around ethical responses to affect by extending and developing on the works of these artists.
Resumo:
Background There is no legal requirement for Iranian military truck drivers to undergo regular visual checkups as compared to commercial truck drivers. Objectives This study aimed to evaluate the impact of drivers’ visual checkups by comparing the visual function of Iranian military and commercial truck drivers. Patients and Methods In this comparative cross-sectional study, two hundred military and 200 commercial truck drivers were recruited and their Visual Acuity (VA), Visual Field (VF), color vision and Contrast Sensitivity (CS) were assessed and compared using the Snellen chart, confrontation screening method, D15 test and Pelli-Robson letter chart, respectively. A questionnaire regarding driving exposure and history of motor-vehicle crashes (MVCs) was also filled by drivers. Results were analyzed using an independent samples t-test, one-way ANOVA (assessing difference in number of MVCs across different age groups), chi-square test and Pearson correlation at statistical significance level of P < 0.05. Results Mean age was 41.6 ± 9.2 for the military truck drivers and 43.4 ± 10.9 for commercial truck drivers (P > 0.05). No significant difference between military and commercial drivers was found in terms of driving experience, number of MVCs, binocular VA, frequency of color vision defects and CS scores. In contrast, the last ocular examination was significantly earlier in military drivers than commercial drivers (P < 0.001). In addition, 4% of military drivers did not meet the national standards to drive as opposed to 2% of commercial drivers. There was a significant but weak correlation between binocular VA and age (r = 0.175, P < 0.001). However, CS showed a significantly moderate correlation with age (r = -0.488, P < 0.001). Conclusions The absence of legal requirement for regular eye examination in military drivers caused the incompetent drivers to be missed in contrast to commercial drivers. The need for scientific revision of VA standard for Iranian drivers is also discussed. The CS measurement in visual checkups of older drivers deserves to be investigated more thoroughly.
Resumo:
Purpose: Presence of neurophysiological abnormalities in dyslexia has been a conflicting issue. This study was performed to evaluate the role of sensory visual deficits in the pathogenesis of dyslexia. Methods: Pattern visual evoked potentials (PVEP) were recorded in 72 children including 36 children with dyslexia and 36 children without dyslexia (controls) who were matched for age, sex and intelligence. Two check sizes of 15 and 60 min of arc were used with temporal frequencies of 1.5 Hz for transient and 6 Hz for steady‑state methods. Results: Mean latency and amplitude values for 15 min arc and 60 min arc check sizes using steady state and transient methods showed no significant difference between the two study groups (P values: 0.139/0.481/0.356/0.062).Furthermore, no significant difference was observed between two methods of PVEPs in dyslexic and normal children using 60min arc with high contrast(Pvalues: 0.116, 0.402, 0.343 and 0.106). Conclusion: The sensitivity of PVEP has high validity to detect visual deficits in children with dyslexic problem. However, no significant difference was found between dyslexia and normal children using high contrast stimuli.
Resumo:
Most bees are diurnal, with behaviour that is largely visually mediated, but several groups have made evolutionary shifts to nocturnality, despite having apposition compound eyes unsuited to vision in dim light. We compared the anatomy and optics of the apposition eyes and the ocelli of the nocturnal carpenter bee, Xylocopa tranquebarica, with two sympatric species, the strictly diurnal X. leucothorax and the occasionally crepuscular X. tenuiscapa. The ocelli of the nocturnal X. tranquebarica are unusually large (diameter ca. 1 mm) and poorly focussed. Moreover, their apposition eyes show specific visual adaptations for vision in dim light, including large size, large facets and very wide rhabdoms, which together make these eyes 9 times more sensitive than those of X. tenuiscapa and 27 times more sensitive than those of X. leucothorax. These differences in optical sensitivity are surprisingly small considering that X. tranquebarica can fly on moonless nights when background luminance is as low as 10(-5) cd m(-2), implying that this bee must employ additional visual strategies to forage and find its way back to the nest. These strategies may include photoreceptors with longer integration times and higher contrast gains as well as higher neural summation mechanisms for increasing visual reliability in dim light.
Resumo:
Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50° eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60° for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10° radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50°). The field results with the annular stop showed at most only a slight loss in sensitivity (≤3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.
Resumo:
In this paper, we consider applying derived knowledge base regarding the sensitivity and specificity of damage(s) to be detected by an SHM system being designed and qualified. These efforts are necessary toward developing capabilities in SHM system to classify reliably various probable damages through sequence of monitoring, i.e., damage precursor identification, detection of damage and monitoring its progression. We consider the particular problem of visual and ultrasonic NDE based SHM system design requirements, where the damage detection sensitivity and specificity data definitions for a class of structural components are established. Methodologies for SHM system specification creation are discussed in details. Examples are shown to illustrate how the physics of damage detection scheme limits particular damage detection sensitivity and specificity and further how these information can be used in algorithms to combine various different NDE schemes in an SHM system to enhance efficiency and effectiveness. Statistical and data driven models to determine the sensitivity and probability of damage detection (POD) has been demonstrated for plate with varying one-sided line crack using optical and ultrasonic based inspection techniques.
Resumo:
Demersal fishes hauled up from depth experience rapid decompression. In physoclists, this can cause overexpansion of the swim bladder and resultant injuries to multiple organs (barotrauma), including severe exophthalmia (“pop-eye”). Before release, fishes can also be subjected to asphyxia and exposure to direct sunlight. Little is known, however, about possible sensory deficits resulting from the events accompanying capture. To address this issue, electroretinography was used to measure the changes in retinal light sensitivity, flicker fusion frequency, and spectral sensitivity in black rockfish (Sebastes melanops) subjected to rapid decompression (from 4 atmospheres absolute [ATA] to 1 ATA) and Pacific halibut (Hippoglossus stenolepis) exposed to 15 minutes of simulated sunlight. Rapid decompression had no measurable influence on retinal function in black rockfish. In contrast, exposure to bright light significantly reduced retinal light sensitivity of Pacific halibut, predominately by affecting the photopigment which absorbs the green wavelengths of light (≈520–580 nm) most strongly. This detriment is likely to have severe consequences for postrelease foraging success in green-wavelength-dominated coastal waters. The visual system of Pacific halibut has characteristics typical of species adapted to low light environments, and these characteristics may underlie their vulnerability to injury from exposure to bright light.
Resumo:
O objetivo deste estudo in vivo foi avaliar comparativamente três técnicas de clareamento de dentes polpados quanto ao grau de cor final alcançado, sensibilidade dental e satisfação pessoal de operadores e pacientes. Indivíduos jovens de mesma faixa etária e padrão de higiene bucal foram selecionados e divididos aleatoriamente entre os grupos (G1; n=7) caseiro, com regime de uso de 8 h/dia/4 semanas; (G2; n=7) consultório, com regime de clareamento de 4 sessões semanais de 2 aplicações de 15 min cada e; (G3; n=6) associado, com caseiro e consultório combinados. Para as técnicas caseira e de consultório foram utilizados peróxido de carbamida a 16% (WhitegoldHome/Dentsply) e peróxido de hidrogênio a 35% (Whitegold Office/Dentsply), respectivamente. Os registros de cor foram obtidos por um único operador antes e após o emprego da cada técnica utilizando escala de cores Vita Bleachedguide 3D-Master e máquina fotográfica digital profissional (EOS Rebel XT Canon), com ajustes de iluminação, flash e distância focal padronizados. O nível de clareamento foi avaliado por unidades de mudança de cor (luminosidade) na escala de cores, além do número de tons alcançados nas imagens digitais e mudança de cor no sistema CIE L*a*b* por meio do software ScanWhite. Os dados foram tratados estatisticamente pelos testes não paramétricos de Kruskal Wallis e dos sinais (p≤0,05). Os registros de sensibilidade dental trans e pós operatória e da satisfação pessoal dos operadores e pacientes foram preenchidos individualmente em questionário unidimensional ao final de cada sessão. Foram atribuídos escores para a avaliação final da sensibilidade dental, conforme: 0=ausente; 1=leve; 2=moderada e; 3=severa. Os dados foram tratados estatisticamente pelo teste Kruskal Wallis. As médias das variações de unidades de mudança de cor da escala Vita e do software foram, respectivamente: G1) 4,57 (IC1,34), 27,14 (IC12,03); G2) 2,86 (IC0,99), 21,29 (IC14,27); G3) 4 (IC1,82), 25,33 (IC10,70). Na comparação entre os métodos de avaliação de cor, os p-valores do teste dos sinais foram 0,453, 0,453 e 0,687 para os grupos 1, 2 e 3, respectivamente. As médias da variação total de cor (∆E) foram, respectivamente: G1) 8,79(IC4,18), G2) 7,10(IC3,53) e G3) 9,74 (IC4,07). Não foi determinada diferença estatisticamente significante entre os grupos. Os postos médios do nível de sensibilidade foram: G1 = 9,64; G2 = 11,58; e G3 = 10,43, e o p-valor = 0,807. Não houve diferença estatisticamente significante entre grupos. Conclui-se que as técnicas caseiro, consultório e associada foram igualmente eficazes quanto ao nível de cor final, de acordo com os métodos objetivos e subjetivos utilizados. O nível de sensibilidade dental foi o mesmo independentemente da técnica utilizada. Todos os indivíduos registraram satisfação ao final do clareamento.
Resumo:
A significant proportion of the processing delays within the visual system are luminance dependent. Thus placing an attenuating filter over one eye causes a temporal delay between the eyes and thus an illusion of motion in depth for objects moving in the fronto-parallel plane, known as the Pulfrich effect. We have used this effect to study adaptation to such an interocular delay in two normal subjects wearing 75% attenuating neutral density filters over one eye. In two separate experimental periods both subjects showed about 60% adaptation over 9 days. Reciprocal effects were seen on removal of the filters. To isolate the site of adaptation we also measured the subjects' flicker fusion frequencies (FFFs) and contrast sensitivity functions (CSFs). Both subjects showed significant adaptation in their FFFs. An attempt to model the Pulfrich and FFF adaptation curves with a change in a single parameter in Kelly's [(1971) Journal of the Optical Society of America, 71, 537-546] retinal model was only partially successful. Although we have demonstrated adaptation in normal subjects to induced time delays in the visual system we postulate that this may at least partly represent retinal adaptation to the change in mean luminance.