956 resultados para underground installations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rate of high energy cosmic ray muons as measured underground is shown to be strongly correlated with upper-air temperatures during short-term atmospheric (10-day) events. The effects are seen by correlating data from the MINOS underground detector and temperatures from the European Centre for Medium Range Weather Forecasts during the winter periods from 2003-2007. This effect provides an independent technique for the measurement of meteorological conditions and presents a unique opportunity to measure both short and long-term changes in this important part of the atmosphere. Citation: Osprey, S., et al. (2009), Sudden stratospheric warmings seen in MINOS deep underground muon data, Geophys. Res. Lett., 36, L05809, doi: 10.1029/2008GL036359.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We review the information currently available on the reproduction of the Amphisbaenia and provide original data on the reproductive biology of four Neotropical species: Amphisbaena alba; A. mertensi; Cercolophia roberti, and Leposternon infraorbitale. In total, we compiled data for 22 species: 17 Amphisbaenidae, 1 Rhineuridae, 3 Bipedidae, and 1 Trogonophidae. The majority of the species were oviparous with the exceptions of Loveridgea ionidesii, Monopeltis anchietae, M. capensis, and Trogonophis wiegmanni. Viviparity was interpreted as a derived trait that evolved independently for at least 3 times within the Amphisbaenia. In most species, reproduction is synchronized with the hot and rainy season and seems to vary with latitude. Although Amphisbaenia eggs have been found in ant nests, it remains disputable whether this is an obligatory or even a preferable location for egg-laying. Incubation time in A. mertensii lasts 59 days and this is the first report encompassing egg-laying to hatching for any Amphisbaenia species. Nonetheless, a two months incubation period seems to be the common rule for oviparous Amphisbaenia. The general pattern of reproductive output in Amphisbaenia is characterized by a low number of eggs/embryos per clutch whose individual size is comparatively large in relation to adult body size. Eggs are markedly elongated on the long axis and arranged in-line within the abdominal cavity possibly to prevent/diminish biomechanic drawbacks of egg bearing. Hatchlings of A. mertensi possess an egg-tooth implanted at the upper jaw, exhibit positive geotropism, and display defensive behaviors known to be present in adults. Our review shows that our current knowledge of Amphisbaenia reproduction is fragmentary, often based on the examination of small samples, and heavily dependent on the publication of anedoctal observations. Future publications on this subject are encouraged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inverse problem concerning the industrial process of steel bars hardening and tempering is considered. The associated optimization problem is formulated in terms of membership functions and, for the sake of comparison, also in terms of quadratic residuals; both geometric and electromagnetic design variables have been considered. The numerical solution is achieved by coupling a finite difference procedure for the calculation of the electromagnetic and thermal fields to a deterministic strategy of minimization based on modified Flctcher and Reeves method. © 1998 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we propose an accurate method for fault location in underground distribution systems by means of an Optimum-Path Forest (OPF) classifier. We applied the Time Domains Reflectometry method for signal acquisition, which was further analyzed by OPF and several other well known pattern recognition techniques. The results indicated that OPF and Support Vector Machines outperformed Artificial Neural Networks classifier. However, OPF has been much more efficient than all classifiers for training, and the second one faster for classification. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need for high reliability and environmental concerns are making the underground networks the most appropriate choice of energy distribution. However, like any other system, underground distribution systems are not free of failures. In this context, this work presents an approach to study underground systems using computational tools by integrating the software PSCAD/EMTDC with artificial neural networks to assist fault location in power distribution systems. Targeted benefits include greater accuracy and reduced repair time. The results presented here shows the feasibility of the proposed approach. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leaking of hydrocarbon in fuel underground storage tanks constitute object of concern for urban environmental management, because therefore they provoke damages to the physical, biological and socioeconomic environment. Though laws that regulate this essential activity exist, aiming at to prevent contamination with hydrocarbon, we observe that this still happens. This fact evidences that the selection of places for installation of gas stations has not considered the characteristics of the natural environment, implying in more critical consequences associated to the leaking. The objective of this work is to elaborate a chart applied to the gas stations in Rio Claro/SP. The determination of the Index of Environmental Sensitivity for elaboration of such chart was carried through breaking the selection of factors of Environmental Sensitivity of physical, biological and socioeconomic environment. The balance of these factors was given by means of Ad hoc consultation. The crossing of the information was carried through using the method of overlapping of overlays. The result is a chart that shows us areas with classes of high, middle and low Environmental Sensitivity. One gives credit that this type of material can be used as criterion in the selection of adjusted areas for installations of new gas stations and management of the already installed gas stations. The diagnosis of the current situation of the gas stations in the area and recommendations had also been elaborated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a cross-layer solution for packet size optimization in wireless sensor networks (WSN) is introduced such that the effects of multi-hop routing, the broadcast nature of the physical wireless channel, and the effects of error control techniques are captured. A key result of this paper is that contrary to the conventional wireless networks, in wireless sensor networks, longer packets reduce the collision probability. Consequently, an optimization solution is formalized by using three different objective functions, i.e., packet throughput, energy consumption, and resource utilization. Furthermore, the effects of end-to-end latency and reliability constraints are investigated that may be required by a particular application. As a result, a generic, cross-layer optimization framework is developed to determine the optimal packet size in WSN. This framework is further extended to determine the optimal packet size in underwater and underground sensor networks. From this framework, the optimal packet sizes under various network parameters are determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the United States the peak electrical use occurs during the summer. In addition, the building sector consumes a major portion of the annual electrical energy consumption. One of the main energy consuming components in the building sector is the Heating, Ventilation, and Air-Conditioning (HVAC) systems. This research studies the feasibility of implementing a solar driven underground cooling system that could contribute to reducing building cooling loads. The developed system consists of an Earth-to-Air Heat Exchanger (EAHE) coupled with a solar chimney that provides a natural cool draft to the test facility building at the Solar Energy Research Test Facility in Omaha, Nebraska. Two sets of tests have been conducted: a natural passively driven airflow test and a forced fan assisted airflow test. The resulting data of the tests has been analyzed to study the thermal performance of the implemented system. Results show that: The underground soil proved to be a good heat sink at a depth of 9.5ft, where its temperature fluctuates yearly in the range of (46.5°F-58.2°F). Furthermore, the coupled system during the natural airflow modes can provide good thermal comfort conditions that comply with ASHRAE standard 55-2004. It provided 0.63 tons of cooling, which almost covered the building design cooling load (0.8 tons, extreme condition). On the other hand, although the coupled system during the forced airflow mode could not comply with ASHRAE standard 55-2004, it provided 1.27 tons of cooling which is even more than the building load requirements. Moreover, the underground soil experienced thermal saturation during the forced airflow mode due to the oversized fan, which extracted much more airflow than the EAHE ability for heat dissipation and the underground soil for heat absorption. In conclusion, the coupled system proved to be a feasible cooling system, which could be further improved with a few design recommendations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The construction of the Agua Negra tunnels that will link Argentina and Chile under the Andes, the world's longest mountain range, opens the possibility of building the first deep underground laboratory in the Southern Hemisphere. This laboratory has the acronym ANDES (Agua Negra Deep Experiment Site) and its overburden could be as large as similar to 1.7 km of rock, or 4500 mwe, providing an excellent low background environment to study physics of rare events like the ones induced by neutrinos and/or dark matter. In this paper we investigate the physics potential of a few kiloton size liquid scintillator detector, which could be constructed in the ANDES laboratory as one of its possible scientific programs. In particular, we evaluate the impact of such a detector for the studies of geoneutrinos and Galactic supernova neutrinos, assuming a fiducial volume of 3 kilotons as a reference size. We emphasize the complementary roles of such a detector to the ones of the Northern Hemisphere neutrino facilities, given the advantages of its geographical location.