910 resultados para smoke detectors
Resumo:
The ill effects of second-hand smoke are now well documented. To protect the population from exposure to tobacco smoke, comprehensive smoking bans are necessary as expressed in the WHO Framework Convention on Tobacco Control and its guidelines. Switzerland has only a partial smoking ban full of exceptions which has been in effect since 2010, which reproduces the so-called Spanish model. In September 2012, the Swiss citizens refused a proposal for a more comprehensive ban. This case study examines the reasons behind this rejection and draws some lessons that can be learnt from it.
Resumo:
The gated operation is proposed as an effective method to reduce the noise in pixel detectors based on Geiger mode avalanche photodiodes. A prototype with the sensor and the front-end electronics monolithically integrated has been fabricated with a conventional HV-CMOS process. Experimental results demonstrate the increase of the dynamic range of the sensor by applying this technique.
Resumo:
Within a drift-diffusion model we investigate the role of the self-consistent electric field in determining the impedance field of a macroscopic Ohmic (linear) resistor made by a compensated semi-insulating semiconductor at arbitrary values of the applied voltage. The presence of long-range Coulomb correlations is found to be responsible for a reshaping of the spatial profile of the impedance field. This reshaping gives a null contribution to the macroscopic impedance but modifies essentially the transition from thermal to shot noise of a macroscopic linear resistor. Theoretical calculations explain a set of noise experiments carried out in semi-insulating CdZnTe detectors.
Resumo:
We study the sensitivity limits of a broadband gravitational-wave detector based on dual resonators such as nested spheres. We determine both the thermal and back-action noises when the resonators displacements are read out with an optomechanical sensor. We analyze the contributions of all mechanical modes, using a new method to deal with the force-displacement transfer functions in the intermediate frequency domain between the two gravitational-wave sensitive modes associated with each resonator. This method gives an accurate estimate of the mechanical response, together with an evaluation of the estimate error. We show that very high sensitivities can be reached on a wide frequency band for realistic parameters in the case of a dual-sphere detector.
Resumo:
BACKGROUND: In May 2010, Switzerland introduced a heterogeneous smoking ban in the hospitality sector. While the law leaves room for exceptions in some cantons, it is comprehensive in others. This longitudinal study uses different measurement methods to examine airborne nicotine levels in hospitality venues and the level of personal exposure of non-smoking hospitality workers before and after implementation of the law. METHODS: Personal exposure to second hand smoke (SHS) was measured by three different methods. We compared a passive sampler called MoNIC (Monitor of NICotine) badge, to salivary cotinine and nicotine concentration as well as questionnaire data. Badges allowed the number of passively smoked cigarettes to be estimated. They were placed at the venues as well as distributed to the participants for personal measurements. To assess personal exposure at work, a time-weighted average of the workplace badge measurements was calculated. RESULTS: Prior to the ban, smoke-exposed hospitality venues yielded a mean badge value of 4.48 (95%-CI: 3.7 to 5.25; n = 214) cigarette equivalents/day. At follow-up, measurements in venues that had implemented a smoking ban significantly declined to an average of 0.31 (0.17 to 0.45; n = 37) (p = 0.001). Personal badge measurements also significantly decreased from an average of 2.18 (1.31-3.05 n = 53) to 0.25 (0.13-0.36; n = 41) (p = 0.001). Spearman rank correlations between badge exposure measures and salivary measures were small to moderate (0.3 at maximum). CONCLUSIONS: Nicotine levels significantly decreased in all types of hospitality venues after implementation of the smoking ban. In-depth analyses demonstrated that a time-weighted average of the workplace badge measurements represented typical personal SHS exposure at work more reliably than personal exposure measures such as salivary cotinine and nicotine.
Resumo:
A passive sampling device called Monitor of NICotine or "MoNIC", was constructed and evaluated by IST laboratory for determining nicotine in Second Hand Tobacco Smoke (SHTS) or Environmental Tobacco Smoke (ETS). Vapour nicotine was passively collected on a potassium bisulfate treated glass fibre filter as collection medium. Analysis of collected nicotine on the treated filter by gas chromatography equipped with Thermoionic-Specific Detector (GC-TSD) after liquid-liquid extraction of 1mL of 5N NaOH : 1 mL of n-heptane saturated with NH3 using quinoline as internal standard. Based on nicotine amount of 0.2 mg/cigarette as the reference, the inhaled Cigarette Equivalents (CE) by non-smokers can be calculated. Using the detected CE on the badge for non-smokers, and comparing with amount of nicotine and cotinine level in saliva of both smokers and exposed non-smokers, we can confirm the use of the CE concept for estimating exposure to ETS. The regional CIPRET (Center of information and prevention of the addiction to smoking) of different cantons (Valais (VS), Vaud (VD), Neuchâtel (NE) and Fribourg (FR)) are going to organize a big campaign on the subject of the passive addiction to smoking. This campaign took place in 2007-2008 and has for objective to inform clearly the Swiss population of the dangerousness of the passive smoke. More than 3'900 MoNIC badges were gracefully distributed to Swiss population to perform a self-monitoring of population exposure level to ETS, expressed in term of CE. Non-stimulated saliva was also collected to determine ETS biomarkers nicotine/cotinine levels of participating volunteers. Results of different levels of CE in occupational and non-occupational situations in relation with ETS were presented in this study. This study, unique in Switzerland, has established a base map on the population's exposure to SHTS. It underscored the fact that all the Swiss people involved in this campaign (N=1241) is exposed to passive smoke, from <0.2 cig/d (10.8%), 1-2 to more than 10 cig/d (89.2%). In the area of high exposure (15-38 cig/d), are the most workers in public restaurant, cafe, bar, disco. By monitoring ETS tracer nicotine and its biomarkers, salivary nicotine and cotinine, it is demonstrated that the MoNIC badge can serve as indicator of CE passive smoking. The MoNIC badge, accompanied with content of salivary nicotine/cotinine can serve as a tool of evaluation of the ETS passive smoking and contributes to supply useful data for future epidemiological studies. It is also demonstrated that the salivary nicotine (without stimulation) is a better biomarker of ETS exposure than cotinine.
Resumo:
Objective: To investigate the association between common carotid artery intima-media thickness (cIMT) and exposure to secondhand smoke (SHS) in children. Methods: Data were available at baseline in the Quebec Adiposity and Lifestyle investigation in Youth (QUALITY) study, an ongoing longitudinal investigation of Caucasian children aged 8e10 years at cohort inception, who had at least one obese parent. Data on exposure to parents, siblings and friends smoking were collected in interviewer-administered child, and self-report parent questionnaires. Blood cotinine was measured with a high sensitivity ELISA. cIMTwas measured by ultrasound. The association between blood cotinine and cIMT was investigated in multivariable linear regression analyses controlling for age, body mass index, and child smoking status. Results: Mean (SD) cIMT (0.5803 (0.04602)) did not differ across age or sex. Overall 26%, 6% and 3% of children were exposed to parents, siblings and friends smoking, respectively. Cotinine ranged from 0.13 ng/ml to 7.38 ng/ml (median (IQR)¼0.18 ng/ml)). Multivariately, a 1 ng/ml increase in cotinine was associated with a 0.090 mm increase in cIMT (p¼0.034). Conclusion: In children as young as age 8e10 years, exposure to SHS relates to cIMT, a marker of pre-clinical atherosclerosis. Given the wide range of health effects of SHS, increased public health efforts are needed to reduced exposure among children in homes an private vehicles.
Resumo:
BACKGROUND/OBJECTIVES: A smoking law was passed by the Spanish Parliament in December 2005 and was enforced by 1 January 2006. The law bans smoking in all indoor workplaces but only in some hospitality venues, because owners are allowed to establish a smoking zone (venues>100 m2) or to allow smoking without restrictions (venues<100 m2). The objective of the study is to assess the impact of the Spanish smoking law on exposure to secondhand smoke (SHS) in enclosed workplaces, including hospitality venues. MATERIALS AND METHODS: The study design is a before-and-after evaluation. We studied workplaces and hospitality venues from eight different regions of Spain. We took repeated samples of vapor-phase nicotine concentration in 398 premises, including private offices (162), public administration offices (90), university premises (43), bars and restaurants (79), and discotheques and pubs (24). RESULTS: In the follow-up period, SHS levels were markedly reduced in indoor offices. The median decrease in nicotine concentration ranged from 60.0% in public premises to 97.4% in private areas. Nicotine concentrations were also markedly reduced in bars and restaurants that became smoke-free (96.7%) and in the no-smoking zones of venues with separate spaces for smokers (88.9%). We found no significant changes in smoking zones or in premises allowing smoking, including discotheques and pubs. CONCLUSIONS: Overall, this study shows the positive impact of the law on reducing SHS in indoor workplaces. However, SHS was substantially reduced only in bars and restaurants that became smoke-free. Most hospitality workers continue to be exposed to very high levels of SHS. Therefore, a 100% smoke-free policy for all hospitality venues is required.
Resumo:
The silicon photomultiplier (SiPM) is a novel detector technology that has undergone a fast development in the last few years, owing to its single-photon resolution and ultra-fast response time. However, the typical high dark count rates of the sensor may prevent the detection of low intensity radiation fluxes. In this article, the time-gated operation with short active periods in the nanosecond range is proposed as a solution to reduce the number of cells fired due to noise and thus increase the dynamic range. The technique is aimed at application fields that function under a trigger command, such as gated fluorescence lifetime imaging microscopy.
Resumo:
The natural dissipation rates of sidestream smoke (SS) particles dispersed in a chamber were studied from the standpoint of a static atmosphere and were expressed as half-lives of residence in the air. The half-lives for particles less than 0.3 micron, 0.3-0.5 micron and 0.5-1 micron were found to be 25.5, 12.8 and 4.9 h, respectively. Total particulate matter (TPM) decreases by half after 6.2 h. Other data on diluted SS in the indoor air were also reported.
Resumo:
Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.
Resumo:
BACKGROUND: There are limited data on the composition and smoke emissions of 'herbal' shisha products and the air quality of establishments where they are smoked. METHODS: Three studies of 'herbal' shisha were conducted: (1) samples of 'herbal' shisha products were chemically analysed; (2) 'herbal' and tobacco shisha were burned in a waterpipe smoking machine and main and sidestream smoke analysed by standard methods and (3) the air quality of six waterpipe cafes was assessed by measurement of CO, particulate and nicotine vapour content. RESULTS: We found considerable variation in heavy metal content between the three products sampled, one being particularly high in lead, chromium, nickel and arsenic. A similar pattern emerged for polycyclic aromatic hydrocarbons. Smoke emission analyses indicated that toxic byproducts produced by the combustion of 'herbal' shisha were equivalent or greater than those produced by tobacco shisha. The results of our air quality assessment demonstrated that mean PM2.5 levels and CO content were significantly higher in waterpipe establishments compared to a casino where cigarette smoking was permitted. Nicotine vapour was detected in one of the waterpipe cafes. CONCLUSIONS: 'Herbal' shisha products tested contained toxic trace metals and PAHs levels equivalent to, or in excess of, that found in cigarettes. Their mainstream and sidestream smoke emissions contained carcinogens equivalent to, or in excess of, those of tobacco products. The content of the air in the waterpipe cafes tested was potentially hazardous. These data, in aggregate, suggest that smoking 'herbal' shisha may well be dangerous to health.
Resumo:
This thesis describes the development of advanced silicon radiation detectors and their characterization by simulations, used in the work for searching elementary particles in the European Organization for Nuclear Research, CERN. Silicon particle detectors will face extremely harsh radiation in the proposed upgrade of the Large Hadron Collider, the future high-energy physics experiment Super-LHC. The increase in the maximal fluence and the beam luminosity up to 1016 neq / cm2 and 1035 cm-2s-1 will require detectors with a dramatic improvement in radiation hardness, when such a fluence will be far beyond the operational limits of the present silicon detectors. The main goals of detector development concentrate on minimizing the radiation degradation. This study contributes mainly to the device engineering technology for developing more radiation hard particle detectors with better characteristics. Also the defect engineering technology is discussed. In the nearest region of the beam in Super-LHC, the only detector choice is 3D detectors, or alternatively replacing other types of detectors every two years. The interest in the 3D silicon detectors is continuously growing because of their many advantages as compared to conventional planar detectors: the devices can be fully depleted at low bias voltages, the speed of the charge collection is high, and the collection distances are about one order of magnitude less than those of planar technology strip and pixel detectors with electrodes limited to the detector surface. Also the 3D detectors exhibit high radiation tolerance, and thus the ability of the silicon detectors to operate after irradiation is increased. Two parameters, full depletion voltage and electric field distribution, is discussed in more detail in this study. The full depletion of the detector is important because the only depleted area in the detector is active for the particle tracking. Similarly, the high electric field in the detector makes the detector volume sensitive, while low-field areas are non-sensitive to particles. This study shows the simulation results of full depletion voltage and the electric field distribution for the various types of 3D detectors. First, the 3D detector with the n-type substrate and partial-penetrating p-type electrodes are researched. A detector of this type has a low electric field on the pixel side and it suffers from type inversion. Next, the substrate is changed to p-type and the detectors having electrodes with one doping type and the dual doping type are examined. The electric field profile in a dual-column 3D Si detector is more uniform than that in the single-type column 3D detector. The dual-column detectors are the best in radiation hardness because of their low depletion voltages and short drift distances.