936 resultados para single family houses


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In a northern European climate a typical solar combisystem for a single family house normally saves between 10 and 30 % of the auxiliary energy needed for space heating and domestic water heating. It is considered uneconomical to dimension systems for higher energy savings. Overheating problems may also occur. One way of avoiding these problems is to use a collector that is designed so that it has a low optical efficiency in summer, when the solar elevation is high and the load is small, and a high optical efficiency in early spring and late fall when the solar elevation is low and the load is large.The study investigates the possibilities to design the system and, in particular, the collector optics, in order to match the system performance with the yearly variations of the heating load and the solar irradiation. It seems possible to design practically viable load adapted collectors, and to use them for whole roofs ( 40 m2) without causing more overheating stress on the system than with a standard 10 m2 system. The load adapted collectors collect roughly as much energy per unit area as flat plate collectors, but they may be produced at a lower cost due to lower material costs. There is an additional potential for a cost reduction since it is possible to design the load adapted collector for low stagnation temperatures making it possible to use less expensive materials. One and the same collector design is suitable for a wide range of system sizes and roof inclinations. The report contains descriptions of optimized collector designs, properties of realistic collectors, and results of calculations of system output, stagnation performance and cost performance. Appropriate computer tools for optical analysis, optimization of collectors in systems and a very fast simulation model have been developed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Test method for integrated solar- biomass systems - Long term prediction trough short term measurementsSP Technical Research Institute of Sweden and SERC, Dalarna University have in cooperation developed a test method for integrated solar and biomass systems. The test method is performed under six days including two summer days, two winter days and two spring/autumn days true to real weather conditions and loads for a single family house. The aim of the test method is to get information about a Combisystem’s annual performance and operation throughout a short term test. Seven different solar Combisystems have been tested within the project together with a pellet boiler without solar collectors. In addition to that a comparative testing has been performed at the two laboratories at SP and at SERC on the same Combisystem. The test method developed within the project has been proved to withstand the aim of the project, which is to be able to compare the performance between the systems. The test method is also suitable for identification of possible operation problems so they can be taken care of and consequently improves the system.The project and the system testing reveal that it is in general favorable to combine biomass pellets with solar heating. Pellet boilers has normally a low performance during the summer period but combined with a solar collector the boiler can be switch off during this period. There are however big differences in performance between the tested. The efficiency of the pellet boiler is highly dependent of the operating conditions and elements like heat losses from the system, system configuration and control strategy have great influence of the performance of the system and the emissions. On the other hand, the performance and the size of the solar collectors have a minor effect on the overall system performance. There is obviously a big potential for improvement of the system´s performance and the developed test method is an essential way to implement this perfection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Allt hårdare lagkrav gör att det är svårt att energieffektivisera befintliga byggnader utan att förändra deras utseende. Syftet med examensarbetet är att utreda hur stor energieffektivisering, för tre befintliga småhus uppförda under 1900-talet, som är möjlig att uppnå genom förbättring av byggnadernas klimatskal, det vill säga tak, väggar, golv, fönster och dörrar, utan att förvanska byggnadernas utseende och samtidigt bevara deras kulturhistoriska värden. Arbetet bestod av en förstudie där tre byggnader identifierades, ett undersökningsskede där information om byggnaderna togs fram och ett slutsatsskede där energibesparande åtgärdsförslag togs fram och utvärderades. Byggnader som var goda representanter för sin tid och stil söktes. Byggnader från 1910-talet, 1930-talet och 1970-talet, lokaliserades. Sedan gjordes det fallstudier med intervjuer och inventeringar. För att utreda byggnadens klimatskal utfördes u-värdesberäkningar och energiberäkningar av befintliga byggander och byggnader baserade på föreslagna åtgärdsförslag. Ingen av byggnaderna nådde efter föreslagna åtgärder ner till passivhuskravet 59 kWh/år/m2 Atemp eller BBR-kravet 110 kWh/år/m2 Atemp för en byggnads specifika energianvändning. Den största möjliga energieffektivisering för de tre byggnaderna uppförda under 1900-talet, som är möjlig att uppnå utan att förvanska byggnadernas utseende och samtidigt bevara deras kulturhistoriska värden är 13,0 kWh/år/m2 Atemp, 49,7 kWh/år/m2 Atemp respektive 64,8 kWh/år/m2 Atemp. Slutsatser från arbetet är att byggnader från 1910-tal kan åtgärdas genom att isolera fönstren, sätta dit en extra dörr på insidan av ytterdörren samt tilläggsisolera snedtaket. Byggnader från 1930-tal kan åtgärdas genom att isolera fönstren med en isolerruta på insidan av fönstret och dörrarna med en extra dörr på insidan av ytterdörren. Byggnader från 1970-tal kan åtgärda fönstren genom att byta ut dem till energifönster, ingen åtgärd för golvet men fasaden isoleras utvändigt med vakuumisolering. Byggnaden från 1970-talet klarade sig bäst i jämförelsen eftersom den var i autentiskt skick från början vilket gjorde att förbättringen blev större än för till exempel byggnaden från 1910-talet som redan var ombyggd innan åtgärder föreslogs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study the monitoring results of prototype installation of a recently developed solar combisystem have been evaluated. The system, that uses a water jacketed pellet stove as auxiliary heater, was installed in a single family house in Borlänge/Sweden. In order to allow an evaluation under realistic conditions the system has been monitored for a time period of one year. From the measurements of the system it could be seen that it is important that the pellet stove has a sufficient buffer store volume to minimize cycling. The measurements showed also that the stove gives a lower share of the produced heat to the water loop than measured under stationary conditions. The solar system works as expected and covers the heat demand during the summer and a part of the heat demand during spring and autumn. Potential for optimization exists for the parasitic electricity demand. The system consumes 680 kWh per year for pumps, valves and controllers which is more than 4% of the total primary heating energy demand.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This research has as its object study focus bioclimatic in architecture and its conection with projects decisions, on what regards to environmental comfort for single-family dwelling. From the analysis of five architectural projects inserted in Natal/RN, warm-moist weather, this research gather informations regarding architectural features guided by shape and space arrengement, which embody important elements for the project design development. Computer simulations assisted as foundation to verify the efficiency grade for these projects strategies from shading analysis. Related strategies for the demands of natural ventilation circulation and thermal mass for refrigeration were analysed as well. Results show that there is an hierarchizing of priorities for the decisions made when it comes to shape and space disposition variables, as well as the way these variables will consider the bioclimatic demands. The analysis, even, show that there is no single way to respond to specific bioclimatic demands, as it points out the value of examination of the projectual solutions throughtout the conception process, in order to achieve an efficient project performance for the envimonment comfort

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the mid-1980s, the magazine Projeto published the Actual Brazilian Architecture catalogue presenting texts by Hugo Segawa and Ruth Verde Zein with a corpus of works and engaged architects of the 1960s and 1970s. To comprehend the Brazilian architectural production post-1964, in those years of the 1980s, became a significant mission to reactivate the Brazilian architectural debate weakened by the military dictatorship. In his doctoral thesis Spadoni (2003) deals with the different ways which characterizes the Brazilian architectural production of the 1970s. Marked by inventiveness, this production was in tune with the modern thinking and in the transition period between the 1970s and the 1980s it synchronized with the international debate about post-modern architecture. Considering Spadoni s doctoral thesis, this work deals with the modern experience observed in the one-family-houses built in the seventies in João Pessoa. Some modern experiences were not clear outside, to observe it, it was necessary to search for the type of experience into the spatial disposition and of the know-how constructive, because into the appearance some houses not make explicit the use of the modern language. Other observed experiences allude to the repertoire of the Brazilian period in the years 1940s-1960s, to the experience of the modern architecture in São Paulo of the 1960s, to the experiences in which the climate of the Northeastern region strongly influenced the architectural conception. We can also find in a reduced number of houses a particular experience: it refers to experiences that expose the constructive doing, which leave the material apparent and apply to the residential type the experience of the industrial pre-fabricated buildings

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Esta pesquisa apresenta o estudo comparativo de reatores anaeróbio de fluxo ascendente e manta de lodo (UASB) e tanque séptico (TS), a fim de investigar a utilização destes reatores em escala unifamiliar no tratamento de esgotos domiciliares. A pesquisa foi realizada em comunidade quilombola próxima a cidade de Belém- PA. Para isto, foram utilizados oito reatores UASB (em forma de “Y”.) e um tanque séptico prismático de câmara única. Os reatores UASB possuíam volume de 0,42 m3, enquanto que o tanque séptico volume de 4,20 m3. Cada reator foi instalado em um domicilio, sendo alimentados exclusivamente por esgoto negro (água, fezes e urina) oriundo dos vasos sanitários dos banheiros. Foi analisada a viabilidade técnica da utilização do primeiro em substituição ao segundo, tendo em vista que o TS é amplamente utilizado em locais do Brasil desprovidos de redes coletoras de esgoto. As operações foram realizadas simultaneamente durante aproximadamente 90 semanas, sendo monitorados parâmetros que possibilitaram a análise da estabilidade operacional e do desempenho de cada reator. Ao final da pesquisa foi observado que os reatores UASB apresentaram desempenho tão satisfatório ou melhor que o do TS no tratamento da matéria orgânica e de sólidos em suspensão. Com isso, ficou evidenciada a viabilidade da aplicação do reator UASB utilizado no tratamento unifamiliar de esgotos de pequenas comunidades rurais.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work refers a comparison between a government’s index budget and another one which take into account the traditional method, in other words, taking real values practice in market as base. For its achievement will be used the design of a low standard single-family residence, quantifying all the materials needed for its construction with Prices Compositions Table for Budget, provided from the PINI publishing. After that, was made two budgets: one based on the SINAPI index costs, provided from Caixa Econômica Federal and calculated for the Brazilian Institute of Geography and Estatistics; and another based on the costs used in the SESC work in Birigui city, as well as values collected from building material stores in the same city. Finally, with both finalized budgets, will be drawn a direct comparison in order to verifying if the index can be use as parameter for budget calculations for low standard residences

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The new Brazilian ABNT NBR 15575 Standard (the ―Standard‖) recommends two methods for analyzing housing thermal performance: a simplified and a computational simulation method. The aim of this paper is to evaluate both methods and the coherence between each. For this, the thermal performance of a low-cost single-family house was evaluated through the application of the procedures prescribed by the Standard. To accomplish this study, the EnergyPlus software was selected. Comparative analyses of the house with varying envelope U-values and solar absorptance of external walls were performed in order to evaluate the influence of these parameters on the results. The results have shown limitations in the current Standard computational simulation method, due to different aspects: weather files, lack of consideration of passive strategies, and inconsistency with the simplified method. Therefore, this research indicates that there are some aspects to be improved in this Standard, so it could better represent the real thermal performance of social housing in Brazil.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Four related cows showed hairless streaks on various parts of the body with no correlation to the pigmentation pattern. The stripes occurred in a consistent pattern resembling the lines of Blaschko. The non-syndromic hairlessness phenotype observed occurred across three generations of a single family and was compatible with an X-linked mode of inheritance. Linkage analysis and subsequent whole genome sequencing of one affected female identified two perfectly associated non-synonymous sequence variants in the critical interval on bovine chromosome X. Both variants occurred in complete linkage disequilibrium and were absent in more than 3900 controls. An ERCC6L missense mutation was predicted to cause an amino acid substitution of a non-conserved residue. Analysis in mice showed no specific Ercc6l expression pattern related to hair follicle development and therefore ERCC6L was not considered as causative gene. A point mutation at the 5'-splice junction of exon 5 of the TSR2, 20S rRNA accumulation, homolog (S. cerevisiae), gene led to the production of two mutant transcripts, both of which contain a frameshift and generate a premature stop codon predicted to truncate approximately 25% of the protein. Interestingly, in addition to the presence of both physiological TSR2 transcripts, the two mutant transcripts were predominantly detected in the hairless skin of the affected cows. Immunohistochemistry, using an antibody against the N-terminal part of the bovine protein demonstrated the specific expression of the TSR2 protein in the skin and the hair of the affected and the control cows as well as in bovine fetal skin and hair. The RNA hybridization in situ showed that Tsr2 was expressed in pre- and post-natal phases of hair follicle development in mice. Mammalian TSR2 proteins are highly conserved and are known to be broadly expressed, but their precise in vivo functions are poorly understood. Thus, by dissecting a naturally occurring mutation in a domestic animal species, we identified TSR2 as a regulator of hair follicle development.