926 resultados para simultaneously extracted metals
Resumo:
The metallic voice is usually confused with ring or nasality by singers and nontrained listeners. who are not used to perceptual vocal analysis. They believe a metallic voice results from a rise in fundamental frequency. A diagnostic error in this aspect may lead to lowering pitch, an incorrect procedure that Could Cause vocal overload and fatigue. The purpose of this article is to Study the quality of metallic voice considering the correlation between information of the physiological and acoustic plans, based on a perceptive consensual assumption. Fiberscopic video pharyngolaryngoscopy was performed on 21 professional singers while speaking vowel [e]-in normal and metallic modes to observe muscular movements and structural changes of the velopharynx, pharynx, and larynx. Vocal samples captured simultaneously to the fiberscopic examination were acoustically analyzed. Frequency and amplitude of the first four formants (F(1), F(2), F(3), and F(4)) were extracted by means of linear predictor coefficients (LPC) Spectrum and were statistically analyzed. Vocal tract adjustments such as velar lowering, pharyngeal wall narrowing, laryngeal rise, aryepiglottic, and lateral laryngeal constrictions were frequently found: there were no significant changes in frequency and amplitude of F(1) in the metallic voiced there were significant increases in amplitudes of F(2), F(3), and F(4) and in frequency for F, metallic Voice perceived as louder was correlated to an increase ill amplitude of F(3) and F(4). Physiological adjustments of velopharynx, pharynx, and larynx are combined in characterizing the metallic voice and can be acoustically related to changes in formant pattern.
Resumo:
Cerebral toxoplasmosis is the most common cerebral mass lesion in AIDS patients in Brazil, and results in high mortality and morbidity, despite free access to HAART (highly active antiretroviral treatment). Molecular diagnosis based on conventional PCR (cnPCR) or real-time quantitative PCR (qrtPCR) has been indispensable for definitive diagnosis. We report here the evaluation of qrtPCR with blood and cerebrospinal fluid (CSF) samples from AIDS patients in Brazil. This prospective study was conducted for 2 years, analysing DNA samples extracted from 149 AIDS patients (98 blood and 51 CSF samples) with confirmed clinical and radiological diagnosis The laboratory diagnosis included cnPCR (with the B22/B23 primer set) and indirect immunofluorescence (IF). For qrtPCR, two primer sets were simultaneously designed based on described genes and using a 6-carboxyfluorescein dye-labelled TaqMan MGB (minor groove binder) probe One was Bug, which amplified a sequence from the B1 gene The other was the RETg, which amplified a PCR product of the 529 bp sequence. The overall cnPCR and qrtPCR results were positive results were observed in 33.6% (50) patients The sensitivities were 98% for cnPCR (B22/B23), and 86 and 98% for qrtPCR (B1Tg and RETg, respectively). Negative reactions were observed in 66 4% patients. The specificities were 97% for cnPCR and qrtPCR (B1Tg). and 88.8% for RETg These data show that RETg PCR is highly sensitive as it amplifies a repeat region with many copies; however, its specificity is lower than the other markers However, B1Tg PCR had good specificity, but lower sensitivity Among the patients, 20 had blood and CSF collected simultaneously Thus, their results permitted us to analyse and compare molecular, serological and clinical diagnosis for a better understanding of the different scenarios of laboratorial and clinical diagnosis. For nine patients with confirmed cerebral toxoplasmosis diagnosis, four scenarios were observed: (i) and (ii) negative molecular diagnosis for CSF and positive for blood with variable IF titres for the sera and CSF (negative or positive), (iii) positive molecular diagnosis with CSF and negative with blood, and (iv) positive molecular diagnosis in both samples. In the latter two situations, normally the IF titres in sera and CSF are variable. Other opportunistic infections were shown in 11 patients Despite the IF titres in sera and CSF being variable, all of them had negative molecular diagnosis for both samples qrtPCR allows for a rapid identification of Toxoplasma gondii DNA in patient samples; in a minority of cases discrepancies occur with the cnPCR.
Resumo:
Neutrophil migration is responsible for tissue damage observed in inflammatory diseases and is also implicated in inflammatory nociception. The use of lectins has been demonstrated to be effective in different activities including anti-inflammatory, antimicrobial, and in cancer therapy. In this study, we addressed the potential use of a lectin from Canavalia grandiflora seeds (ConGF) to control neutrophil migration and inflammatory hypernociception. Pretreatment of the animals intravenously (15 min before) with ConGF inhibited neutrophil migration to the peritoneal cavity in a dose-dependent fashion confirmed by an inhibition of rolling and adhesion of leukocytes by intravital microscopy. Another set of experiments showed that pretreatment of the animals with ConGF inhibited the mechanical hypernociception in mice induced by the i.pl. injection of carrageenan or formalin. This anti-nociceptive effect correlated with an effective blockade of neutrophil influx, as assessed by the hind paw tissue myeloperoxidase levels. Furthermore, ConGF had important inhibitory effects on the mouse carrageenan-induced paw edema. In addition, animals treated with ConGF showed inhibition of cytokines release. In conclusion, we demonstrated that the lectin ConGF inhibits neutrophil migration and mechanical inflammatory hypernociception.
Resumo:
The common bean is affected by several pathogens that can cause severe yield losses. Here we report the introgression of resistance genes to anthracnose, angular leaf spot and rust in the `carioca-type` bean cultivar `Ruda`. Initially, four backcross (BC) lines were obtained using `TO`, `AB 136`, `Ouro Negro` and `AND 277` as donor parents. Molecular fingerprinting was used to select the lines genetically closer to the recurrent parent. The relative genetic distances between `Ruda` and the BC lines varied between 0.0% and 1.99%. The BC lines were intercrossed and molecular markers linked to the resistance genes were used to identify the plants containing the genes of interest. These plants were selfed to obtain the F(2), F(3) and F(4) plants which were selected based on the presence of the molecular markers mentioned and resistance was confirmed in the F(4) generation by inoculation. Four F(4:7) pyramid lines with all the resistance genes showed resistance spectra equivalent to those of their respective donor parents. Yield tests showed that these lines are as productive as the best `carioca-type` cultivars.
Resumo:
A nongravimetric acetyl bromide lignin (ABL) method was evaluated to quantify lignin concentration in a variety of plant materials. The traditional approach to lignin quantification required extraction of lignin with acidic dioxane and its isolation from each plant sample to construct a standard curve via spectrophotometric analysis. Lignin concentration was then measured in pre-extracted plant cell walls. However, this presented a methodological complexity because extraction and isolation procedures are lengthy and tedious, particularly if there are many samples involved. This work was targeted to simplify lignin quantification. Our hypothesis was that any lignin, regardless of its botanical origin, could be used to construct a standard curve for the purpose of determining lignin concentration in a variety of plants. To test our hypothesis, lignins were isolated from a range of diverse plants and, along with three commercial lignins, standard curves were built and compared among them. Slopes and intercepts derived from these standard curves were close enough to allow utilization of a mean extinction coefficient in the regression equation to estimate : lignin concentration in any plant, independent of its botanical origin. Lignin quantification by use of a common regression equation obviates the steps of lignin extraction, isolation, and standard curve construction, which substantially expedites the ABL method. Acetyl bromide lignin method is a fast, convenient analytical procedure that may routinely be used to quantify lignin.
Resumo:
The authors undertook this study to assess levels of cadmium exposure in the general population. Samples of lung, liver, and kidney were obtained from 61 cadavers (43 males, 18 females; 2-89 yr of age, mean age = 38.5 yr) who died from accidental causes and who were subject to postmortem examinations at the John Tonge Centre for Forensic Sciences, Queensland Health Scientific Services, Brisbane, Australia, in 1997 and 1998. Samples of bladder urine were also obtained from 22 cadavers. Tissue and urine samples were analyzed for cadmium, zinc, and copper with inductively coupled plasm (ICP) mass spectrometry. The overall mean values for cadmium in the lung, liver, and kidney cortex samples were 0.13, 0.95, and 15.45 mug/gm wet tissue weight. The average renal cadmium level in subjects with high lung-cadmium levels (n = 13) was 6 mug/gm wet tissue weight higher than that of similarly aged subjects who had medium lung-cadmium levels (n = 30). In females, the average level of cadmium in the liver was 74% greater than in males, and the average liver cadmium in females with high lung-cadmium levels was 100% higher than in males in the same age range who had the same high lung-cadmium levels. Renal cadmium accumulation tended to be greater in females than in males who were in the same age range and who had similar lung-cadmium levels, a result that suggested that there was a higher absorption rate of cadmium in females. The mean value for a urinary cadmium excretion of 2.30 mug/gm creatinine was found in a subset of samples that had a mean age of 39 yr and a renal cortex cadmium concentration of 18.6 mug/gm wet tissue weight. Urinary cadmium excretion rates were correlated more strongly with lung and kidney cadmium content than with age or liver cadmium levels. The results suggest that urinary cadmium excretion may be increased in smokers and could provide some estimate of body cadmium burdens in future Australian epidemiological studies.
Resumo:
The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.
Resumo:
This work presents for the first time a systematic study on the optimization of the electrochemical cleaning time of a mercury film when it is used as a working electrode material in the analysis of toxic metals, such as Pb2+, used as model metal, in real samples by SWASV. The optimization study for the film’s cleaning time aimed at attaining a Pb2+ minimum value in the film after the re-oxidation step of the pre-concentrated metal, given the impossibility of complete removal of traces of the electroactive species from the film. This value was kept constant in each concentration range studied ensuring thus that all assays were performed in initial identical conditions. An assay performed on a synthetic sample was taken as reference. In it, given the absence of matrix effects, and after the electrochemical cleaning step, a direct proportionality was observed between the residual amounts of Pb2+ in the film (which for the cleaning time used was never completely removed) and Pb2+ concentration in the solution. This fact determined a high correlation between Pb2+ peak current and Pb2+ concentration which was not observed when real samples (tree leaves) were analyzed. This behavior may result from the presence of the interfering surfactants always present in real samples of complex matrix. Cleaning time optimization was performed for the following Pb2+ concentration ranges in the real samples of complex matrix: 0.006-0.020, 0.020-0.080, 0.060-0.200 and 0.100-0.600 ppb. As expected, in order to obtain identical levels of film’s cleaning efficiency, the need for longer cleaning times has been observed for higher concentrations. The optimized cleaning times for the concentration ranges under study were 120, 150, 180 e 300 s, respectively.
Resumo:
Reuse of tire crumb in sport facilities is currently a very cost-effective waste management measure. Considering that incorporation of the waste materials in artificial turf would be facilitated if the rubber materials were already colored green, coatings were specifically developed for this purpose. This paper presents an experimental toxicological and environmental assessment aimed at comparing the obtained emissions to the environment in terms of polycyclic aromatic hydrocarbons (PAHs), heavy metals, and ecotoxicity for coated and noncoated rubber granulates. This study is a comprehensive evaluation of the major potential critical factors related with the release of all of these classes of pollutants because previous studies were not systematically performed. It was concluded that between the two types of coatings tested, one is particularly effective in reducing emissions to the environment, simultaneously meeting the requirements of adherence and color stability.
Resumo:
Dissertação de Mestrado em Ambiente, Saúde e Segurança.
Oxidative Leaching of metals from electronic waste with solutions based on quaternary ammonium salts
Resumo:
The treatment of electric and electronic waste (WEEE) is a problem which receives ever more attention. An inadequate treatment results in harmful products ending up in the environment. This project intends to investigate the possibilities of an alternative route for recycling of metals from printed circuit boards (PCBs) obtained from rejected computers. The process is based on aqueous solutions composed of an etchant, either 0.2 M CuCl2.2H2O or 0.2 M FeCl3.6H2O, and a quaternary ammonium salt (quat) such as choline chloride or chlormequat. These solutions are reminiscent of deep eutectic solvents (DES) based on quats. DES are quite similar to ionic liquids (ILs) and are used as well as alternative solvents with a great diversity of physical properties, making them attractive for replacement of hazardous, volatile solvents (e.g. VOCs). A remarkable difference between genuine DES and ILs with the solutions used in this project is the addition of rather large quantities of water. It is shown the presence of water has a lot of advantages on the leaching of metals, while the properties typical for DES still remain. The oxidizing capacities of Cu(II) stem from the existence of a stable Cu(I) component in quat based DES and thus the leaching stems from the activity of the Cu(II)/Cu(I) redox couple. The advantage of Fe(III) in combination with DES is the fact that the Fe(III)/Fe(II) redox couple becomes reversible, which is not true in pure water. This opens perspectives for regeneration of the etching solution. In this project the leaching of copper was studied as a function of gradual increasing water content from 0 - 100w% with the same concentration of copper chloride or iron(III) chloride at room temperature and 80ºC. The solutions were also tested on real PCBs. At room temperature a maximum leaching effect for copper was obtained with 30w% choline chloride with 0.2 M CuCl2.2H2O. The leaching effect is still stronger at 80°C, b ut of course these solutions are more energy consuming. For aluminium, tin, zinc and lead, the leaching was faster at 80ºC. Iron and nickel dissolved easily at room temperature. The solutions were not able to dissolve gold, silver, rhodium and platinum.