964 resultados para selected reaction monitoring


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A gas chromatographic/mass spectrometric method is described for the detection of clenbuterol residues in liver, muscle, urine and retina. Tissue samples are first digested using protease and any clenbuterol present is extracted using a simple liquid/liquid extraction procedure. The dried extracts are then derivatized using methylboronic acid and the derivatives are subjected to gas chromatography/mass spectrometry on a magnetic sector instrument. The detection limit of the assay is 0.05 ng g-1 clenbuterol in liver, muscle or urine using a 10 g sample size, and 4 ng g-1 in retina using a 0.5 g sample size. The assay is made very specific by using selected ion monitoring of three ions at a resolution of 3500 and by ion ratio measurements. The precision and reproducibility of the assay are enhanced by the use of a deuterated internal standard, with a typical coefficient of variation of 3%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We have developed a new technique for quantifying methionine sulfoxide (MetSO) in protein to assess levels of oxidative stress in physiological systems. In this procedure, samples are hydrolyzed with methanesulfonic acid (MSA) in order to avoid the conversion of MetSO to methionine (Met) that occurs during hydrolysis of protein in HCl. The hydrolysate is fractionated on a cation exchange column to remove the nonvolatile MSA from amino acids, and the amino acids are then derivatized as their trimethylsilyl esters for analysis by selected ion monitoring-gas chromatography/mass spectrometry. The limit of detection of the assay is 200 pmol of MetSO per analysis, and the interassay coefficient of variation is 5.8%. Compared to current methods, the SIM-GC/MS assay avoids the potential for conversion of Met to MetSO during sample preparation, requires less sample preparation time, has lower variability, and uses mass spectrometry for sensitive and specific analyte detection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The synthesis and characterization of 2-dodecylcyclobutanone is described. Solvent extraction techniques for the isolation of this compound from irradiated minced chicken meat and its detection by selected ion monitoring are outlined. The compound was not detected in either raw or cooked nonirradiated minced chicken meat by the methods used, but its presence was confirmed in the irradiated samples. 2-Dodecyclobutanone was detectable for 20 days postirradiation. The dose (4.7 kGy) of irradiation applied was below the recommended upper limit for food (10 kGy), and this compound may have potential as a marker for irradiated chicken meat and for other foods containing lipid.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Traditional Chinese Medicines (TCMs) derived from animal horns are one of the most important types of Chinese medicine. In the present study, a fast and sensitive analytical method was established for qualitative and quantitative determination of 14 nucleosides and nucleobases in animal horns using hydrophilic interaction ultra-high performance liquid chromatography coupled with triple-quadruple tandem mass spectrometry (HILIC-UPLC-QQQ-MS/MS) in selective reaction monitoring (SRM) mode. The method was optimized and validated, and showed good linearity, precision, repeatability, and accuracy. The method was successfully used to determine contents of the 14 nucleosides and nucleobases in 25 animal horn samples. Hierarchical clustering analysis (HCA) and principal component analysis (PCA) were performed and the 25 samples were thereby divided into two groups, which agreed with taxonomy. The method may enable quick and effective search of substitutes for precious horns.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vitis vinifera L., the most widely cultivated fruit crop in the world, was the starting point for the development of this PhD thesis. This subject was exploited following on two actual trends: i) the development of rapid, simple, and high sensitive methodologies with minimal sample handling; and ii) the valuation of natural products as a source of compounds with potential health benefits. The target group of compounds under study were the volatile terpenoids (mono and sesquiterpenoids) and C13 norisoprenoids, since they may present biological impact, either from the sensorial point of view, as regards to the wine aroma, or by the beneficial properties for the human health. Two novel methodologies for quantification of C13 norisoprenoids in wines were developed. The first methodology, a rapid method, was based on the headspace solid-phase microextraction combined with gas chromatography-quadrupole mass spectrometry operating at selected ion monitoring mode (HS-SPME/GC-qMS-SIM), using GC conditions that allowed obtaining a C13 norisoprenoid volatile signature. It does not require any pre-treatment of the sample, and the C13 norisoprenoid composition of the wine was evaluated based on the chromatographic profile and specific m/z fragments, without complete chromatographic separation of its components. The second methodology, used as reference method, was based on the HS-SPME/GC-qMS-SIM, allowing the GC conditions for an adequate chromatographic resolution of wine components. For quantification purposes, external calibration curves were constructed with β-ionone, with regression coefficient (r2) of 0.9968 (RSD 12.51 %) and 0.9940 (RSD of 1.08 %) for the rapid method and for the reference method, respectively. Low detection limits (1.57 and 1.10 μg L-1) were observed. These methodologies were applied to seventeen white and red table wines. Two vitispirane isomers (158-1529 L-1) and 1,1,6-trimethyl-1,2-dihydronaphthalene (TDN) (6.42-39.45 μg L-1) were quantified. The data obtained for vitispirane isomers and TDN using the two methods were highly correlated (r2 of 0.9756 and 0.9630, respectively). A rapid methodology for the establishment of the varietal volatile profile of Vitis vinifera L. cv. 'Fernão-Pires' (FP) white wines by headspace solid-phase microextraction combined with comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (HS-SPME/GCxGC-TOFMS) was developed. Monovarietal wines from different harvests, Appellations, and producers were analysed. The study was focused on the volatiles that seem to be significant to the varietal character, such as mono and sesquiterpenic compounds, and C13 norisoprenoids. Two-dimensional chromatographic spaces containing the varietal compounds using the m/z fragments 93, 121, 161, 175 and 204 were established as follows: 1tR = 255-575 s, 2tR = 0,424-1,840 s, for monoterpenoids, 1tR = 555-685 s, 2tR = 0,528-0,856 s, for C13 norisoprenoids, and 1tR = 695-950 s, 2tR = 0,520-0,960 s, for sesquiterpenic compounds. For the three chemical groups under study, from a total of 170 compounds, 45 were determined in all wines, allowing defining the "varietal volatile profile" of FP wine. Among these compounds, 15 were detected for the first time in FP wines. This study proposes a HS-SPME/GCxGC-TOFMS based methodology combined with classification-reference sample to be used for rapid assessment of varietal volatile profile of wines. This approach is very useful to eliminate the majority of the non-terpenic and non-C13 norisoprenic compounds, allowing the definition of a two-dimensional chromatographic space containing these compounds, simplifying the data compared to the original data, and reducing the time of analysis. The presence of sesquiterpenic compounds in Vitis vinifera L. related products, to which are assigned several biological properties, prompted us to investigate the antioxidant, antiproliferative and hepatoprotective activities of some sesquiterpenic compounds. Firstly, the antiradical capacity of trans,trans-farnesol, cis-nerolidol, α-humulene and guaiazulene was evaluated using chemical (DPPH• and hydroxyl radicals) and biological (Caco-2 cells) models. Guaiazulene (IC50= 0.73 mM) was the sesquiterpene with higher scavenger capacity against DPPH•, while trans,trans-farnesol (IC50= 1.81 mM) and cis-nerolidol (IC50= 1.48 mM) were more active towards hydroxyl radicals. All compounds, with the exception of α-humulene, at non-cytotoxic levels (≤ 1 mM), were able to protect Caco-2 cells from oxidative stress induced by tert-butyl hydroperoxide. The activity of the compounds under study was also evaluated as antiproliferative agents. Guaiazulene and cis-nerolidol were able to more effectively arrest the cell cycle in the S-phase than trans,trans-farnesol and α-humulene, being the last almost inactive. The relative hepatoprotection effect of fifteen sesquiterpenic compounds, presenting different chemical structures and commonly found in plants and plant-derived foods and beverages, was assessed. Endogenous lipid peroxidation and induced lipid peroxidation with tert-butyl hydroperoxide were evaluated in liver homogenates from Wistar rats. With the exception of α-humulene, all the sesquiterpenic compounds under study (1 mM) were effective in reducing the malonaldehyde levels in both endogenous and induced lipid peroxidation up to 35% and 70%, respectively. The developed 3D-QSAR models, relating the hepatoprotection activity with molecular properties, showed good fit (R2LOO > 0.819) with good prediction power (Q2 > 0.950 and SDEP < 2%) for both models. A network of effects associated with structural and chemical features of sesquiterpenic compounds such as shape, branching, symmetry, and presence of electronegative fragments, can modulate the hepatoprotective activity observed for these compounds. In conclusion, this study allowed the development of rapid and in-depth methods for the assessment of varietal volatile compounds that might have a positive impact on sensorial and health attributes related to Vitis vinifera L. These approaches can be extended to the analysis of other related food matrices, including grapes and musts, among others. In addition, the results of in vitro assays open a perspective for the promising use of the sesquiterpenic compounds, with similar chemical structures such as those studied in the present work, as antioxidants, hepatoprotective and antiproliferative agents, which meets the current challenges related to diseases of modern civilization.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado, Qualidade em Análises, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2015

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tese de doutoramento, Biologia (Biologia Molecular), Universidade de Lisboa, Faculdade de Ciências, 2015

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A vigilância de efeitos indesejáveis após a vacinação é complexa. Existem vários actores de confundimento que podem dar origem a associações espúrias, meramente temporais mas que podem provocar uma percepção do risco alterada e uma consequente desconfiança generalizada acerca do uso das vacinas. Com efeito as vacinas são medicamentos complexos com características únicas cuja vigilância necessita de abordagens metodológicas desenvolvidas para esse propósito. Do exposto se entende que, desde o desenvolvimento da farmacovigilância se tem procurado desenvolver novas metodologias que sejam concomitantes aos Sistemas de Notificação Espontânea que já existem. Neste trabalho propusemo-nos a desenvolver e testar um modelo de vigilância de reacções adversas a vacinas, baseado na auto-declaração pelo utente de eventos ocorridos após a vacinação e testar a capacidade de gerar sinais aplicando cálculos de desproporção a datamining. Para esse efeito foi constituída uma coorte não controlada de utentes vacinados em Centros de Saúde que foram seguidos durante quinze dias. A recolha de eventos adversos a vacinas foi efectuada pelos próprios utentes através de um diário de registo. Os dados recolhidos foram objecto de análise descritiva e análise de data-mining utilizando os cálculos Proportional Reporting Ratio e o Information Component. A metodologia utilizada permitiu gerar um corpo de evidência suficiente para a geração de sinais. Tendo sido gerados quatro sinais. No âmbito do data-mining a utilização do Information Component como método de geração de sinais parece aumentar a eficiência científica ao permitir reduzir o número de ocorrências até detecção de sinal. A informação reportada pelos utentes parece válida como indicador de sinais de reacções adversas não graves, o que permitiu o registo de eventos sem incluir o viés da avaliação da relação causal pelo notificador. Os principais eventos reportados foram eventos adversos locais (62,7%) e febre (31,4%).------------------------------------------ABSTRACT: The monitoring of undesirable effects following vaccination is complex. There are several confounding factors that can lead to merely temporal but spurious associations that can cause a change in the risk perception and a consequent generalized distrust about the safe use of vaccines. Indeed, vaccines are complex drugs with unique characteristics so that its monitoring requires specifically designed methodological approaches. From the above-cited it is understandable that since the development of Pharmacovigilance there has been a drive for the development of new methodologies that are concomitant with Spontaneous Reporting Systems already in place. We proposed to develop and test a new model for vaccine adverse reaction monitoring, based on self-report by users of events following vaccination and to test its capability to generate disproportionality signals applying quantitative methods of signal generation to data-mining. For that effect we set up an uncontrolled cohort of users vaccinated in Healthcare Centers,with a follow-up period of fifteen days. Adverse vaccine events we registered by the users themselves in a paper diary The data was analyzed using descriptive statistics and two quantitative methods of signal generation: Proportional Reporting Ratio and Information Component. themselves in a paper diary The data was analyzed using descriptive statistics and two quantitative methods of signal generation: Proportional Reporting Ratio and Information Component. The methodology we used allowed for the generation of a sufficient body of evidence for signal generation. Four signals were generated. Regarding the data-mining, the use of Information Component as a method for generating disproportionality signals seems to increase scientific efficiency by reducing the number of events needed to signal detection. The information reported by users seems valid as an indicator of non serious adverse vaccine reactions, allowing for the registry of events without the bias of the evaluation of the casual relation by the reporter. The main adverse events reported were injection site reactions (62,7%) and fever (31,4%).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Le long bio-polymère d'ADN est condensé à l’intérieur du noyau des cellules eukaryotes à l'aide de petites protéines appelées histones. En plus de leurs fonctions condensatrices,ces histones sont également la cible de nombreuses modifications post-traductionnelles(MPT), particulièrement au niveau de leur section N-terminale. Ces modifications réversibles font partie d’un code d’histones épi-génétique transmissible qui orchestre et module dynamiquement certains événements impliquant la chromatine, tels l’activation et la désactivation de gènes ainsi que la duplication et la réparation d’ADN. Ces modifications sont impliquées subséquemment dans la signalisation et la progression de cancers, tels que la leucémie. En conséquence, l'élucidation des modifications d’histones est importante pour comprendre leurs fonctions biologiques. Une méthodologie analytique a été mise au point en laboratoire pour isoler, détecter, et quantifier les MPT d’histones en utilisant une approche rapide à deux volets à l’aide d’outils bioinformatiques spécialisés. La méthodologie développée en laboratoire a été validée en utilisant des histones de souche sauvage ainsi que deux types d’histones mutants déficients en enzymes acétyltransferase. Des trois sources d’histones utilisées, la seule MPT qui a démontré un changement significatif est l’acétylation de l’histone H3 à lysine 56 (H3K56ac). L’expression et la stoechiométrie de cette MPT, issue de cellules de souche sauvage et de cellules mutantes, ont été déterminées avec précision et comparées. Les fonctions de balayage polyvalentes d'un instrument à trappe ionique quadrupôle linéaire hybride ont été utilisées pour améliorer la détection de protéines intactes. Le mode de balayage « enhanced multiply charged » (EMC) a été modifié pour contenir et détecter les ions de protéines intactes situées dans la trappe ionique linéaire. Ce mode de balayage nommé « targeted EMC » (tEMC) a permis de quadrupler le niveau de sensibilité (signal/interférence), et quintupler la résolution du mode de balayage conventionnel. De plus, la capacité de séparation des charges du tEMC a réduit de façon significative les effets de « space charge » dans la trappe ionique linéaire. La résolution supérieure du mode tEMC a permis de différencier plusieurs isoformes modifiées, particulièrement pour l’histone H3. L’analyse des peptides d’histones trypsiques à l’aide du mode de balayage « MRM » a permis le séquençage et la quantification de MPT avec un haut degré de précision. La seule MPT qui était sous-exprimée entre l’histone de souche sauvage et le mutant DOT1L fut la méthylation de l’histone H3 lysine 79(H3K79me1). Les effets de deux inhibiteurs d’enzymes HDAC (HDACi) sur l’expression de MPT d’histone ont été évalués en utilisant la méthodologie analytique mentionnée. Les histones extraites de cellules normales et cancéreuses ont été exposées à du Vorinostat(SAHA) ou du Entinostat (MS-275) pour une période de 24 à 72 heures. Deux histones furent principalement affectées, soit H3 et H4. Étonnamment, les mêmes effets n'ont pas été détectés lorsque les cellules normales ont été traitées avec le HDACi pour une période de 48 à 72 heures. Une méthode absolue de quantification avec une courbe d’étalonnage a été développée pour le peptide H3K56ac. Contrairement à certaines publications, nos résultats démontrent que cette MPT est présente dans les cellules mammifères avec une stoechiométrie très basse (< 0,1%) et n'est pas surexprimée de façon significative après le traitement au HDACi.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: To assess the bioequivalence of three ibuprofen formulations (Test formulation: ibuprofen (400 mg capsule) manufactured by Cardinal Health Brasil 402 Ltda. (Sorocaba, Brazil) and licensed to Boehringer Ingelheim do Brasil Quim. e Farm. Ltda. (Sao Paulo, Brazil); Reference formulation (1): ibuprofen (Advil (R); 2 x 200 mg coated tablet) from Wyeth-Whitehall Ltda. (Itapevi, Brazil); Reference formulation (2): ibuprofen (Alivium (R); 8 ml x 50 mg/ml solution) from Schering Plough S.A. (Rio de Janeiro, Brazil)) in 24 healthy volunteers of both sexes. Methods: The study was conducted using an open, randomized, three-period crossover design with at least 5-day washout interval. Plasma samples were obtained over a 24-h period. Plasma ibuprofen concentrations were analyzed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) with negative ion electrospray ionization using multiple reaction monitoring (MRM). The following pharmacokinetic parameters were obtained from the ibuprofen plasma concentration vs. time curves: AUC(last), AUC(trunctmax) AUC(inf) and C-max. Results: The limit of quantification for ibuprofen was 0.1 mu g x ml(-1). The geometric mean with corresponding 90% confidence interval (CI) for Test/Reference (1) percent ratios were 114.24% (90% CI = 105.67, 123.50%) for C-max, 98.97% (90% CI = 94.69, 103.44%) for AUC(last) and 99.40% (90% CI = 95.21, 103.78%) for AUCinf. The geometric mean and respective 90% confidence interval (CI) for Test/Reference (2) percent ratios were 108.38% (90% Cl = 100.195, 117.25%) for C-max, 100.79% (90% CI = 96.39, 105.40%) for AUC(last) and 101.26% (90% CI = 96.94, 105.77%) for AUC(inf); t(max) for the 400 mg Test capsule was shorter than that for the 2 x 200 mg Reference (1) tablets (p < 0.002). Conclusion: Since the 90% CI for AUC(last), AUC(inf) and C-max ratios were within the 80 - 125% interval proposed by the US FDA, it was concluded that ibuprofen formulation manufactured by Cardinal Health Brasil 402 Ltda. and licensed to Boehringer Ingelheim do Brasil Quim. e Farm. Ltda. is bioequivalent to the Advil (R) and Alivium (R) formulations with regard to both the rate and the extent of absorption.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ultraviolet radiation is one of the most deleterious forms of radiation to terrestrial organisms and is involved in formation of mutagenic pyrimidine dimers and oxidized nucleotides. The biflavonoid fraction (BFF), extracted from needles of Araucaria angustifolia was capable of protecting calf thymus DNA from damage induced by UV radiation. This occurred through prevention of cyclobutane thymine dimer and 8-oxo-7,8-dihydro-2`-deoxyguanosine formation, this being quantified by high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) in a multiple reaction monitoring mode (MRM) and by HPLC-coulometric detection, respectively. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Exocyclic DNA adducts produced by exogenous and endogenous compounds are emerging as potential tools to study a variety of human diseases and air pollution exposure. A highly sensitive method involving online reverse-phase high performance liquid chromatography with electrospray tandem mass spectrometry detection in the multiple reaction monitoring mode and employing stable isotope-labeled internal standards was developed for the simultaneous quantification of 1,N(2)-etheno-2`-deoxyguanosine (1,N(2)-epsilon dGuo) and 1,N(2)-propano-2`-deoxyguanosine (1,N(2)-propanodGuo) in DNA. This methodology permits direct online quantification of 2`-deoxyguanosine and ca. 500 amol of adducts in 100 mu g of hydrolyzed DNA M the same analysis. Using the newly developed technique, accurate determinations of 1,N(2)-etheno-2`-deoxyguanosine and 1,N2-propano-2`-deoxyguanosine levels in DNA extracts of human cultured cells (4.01 +/- 0.32 1,N(2)-epsilon dGuo/10(8) dGuo and 3.43 +/- 0.33 1,N(2)-propanodGuo/10(8) dGuo) and rat tissue (liver, 2.47 +/- 0.61 1,N(2)-epsilon dGuo/10(8) dGuo and 4.61 +/- 0.69 1,N(2)-propanodGuo/108 dGuo; brain, 2.96 +/- 1.43,N(2)-epsilon dGuo/10(8) dGuo and 5.66 +/- 3.70 1,N(2)-propanoclGuo/10(8) dGuo; and lung, 0,87 +/- 0.34 1,N(2)-edGuo/ 10(8) dGuo and 2.25 +/- 1.72 1,N(2)-propanodGuo/10(8) dGuo) were performed. The method described herein can be used to study the biological significance of exocyclic DNA adducts through the quantification of different adducts in humans and experimental an with pathological conditions and after air pollution exposure.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Primary and secondary amines, including amino acids, biogenic amines, hormones, neurotransmitters, and plant siderophores, are readily derivatized with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate using easily performed experimental methodology. Complex mixtures of these amine derivatives can be fractionated and quantified using liquid chromatography–electrospray ionization-mass spectrometry (LC–ESI-MS). Upon collision induced dissociation (CID) in a quadrupole collision cell, all derivatized compounds lose the aminoquinoline tag. With the use of untargeted fragmentation scan functions, such as precursor ion scanning, the loss of the aminoquinoline tag (Amq) can be monitored to identify derivatized species; and the use of targeted fragmentation scans, such as multiple reaction monitoring, can be exploited to quantitate amine-containing molecules. Further, with the use of accurate mass, charge state, and retention time, identification of unknown amines is facilitated. The stability of derivatized amines was found to be variable with oxidatively labile derivatives rapidly degrading. With the inclusion of antioxidant and reducing agents, tris(2-carboxyethyl)-phosphine (TCEP) and ascorbic acid, into both extraction solvents and reaction buffers, degradation was significantly decreased, allowing reproducible identification and quantification of amine compounds in large sample sets.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente trabalho conjuga estudo de fármacos e pesticidas em nível de traços como poluentes no meio aquoso, envolvendo o uso de cromatografia líquida com detector espectrofotométrico na região do ultravioleta (HPLC-UV) para fármacos e cromatografia líquida com detector espectrométrico de massas (LC-ESI-MS-MS) para pesticidas. Quatro fármacos (antibióticos), a saber: ampicilina, amoxilina, tetraciclina e cefalexina, foram avaliados em presença de diversas fases móveis, que foram selecionadas de acordo com a melhor performance cromatográfica, sendo que ampicilina e amoxilina apresentaram melhor performance cromatográfica na mesma fase móvel. Para extração em fase sólida dos fármacos amoxilina e ampicilina foram avaliados três fases comerciais: LC- 18 (SUPELCLEAN), Supelclean TM ENVI TM-Chrom P, Abselut NEXUS. Para os fármacos cefalexina e tetraciclina, além das fases comercias foram avaliadas três novas fases a base de sílicas funcionalizadas com zirconocenos: (MeCp)2ZrCl2, (nBuCp)2ZrCl2 e (iBuCp)2ZrCl2. Amoxilina e ampicilina não apresentaram boas recuperações nas fases e eluentes estudados. Para tetraciclina e cefalexina, a fase comercial Chrom P apresentou boas recuperações quando utilizados os solventes metanol e a mistura 1% de solução aquosa de ácido acético e metanol (60:40), respectivamente. Com relação aos pesticidas, diversas classes (triazinas, feniluréias, organofosforados, anilina, ácidos, molinato e propanil) foram estudadas, somando um total de 20 pesticidas. Três colunas foram avaliadas em diferentes gradientes. Foi selecionada a coluna Purospher START RP e o gradiente acetonitrila-água. Triazinas, feniluréias, organosfosforados, anilinas e o pesticida propanil foram determinadas em modo de ionização spray eletrônico positivo, os pesticidas ácidos e propanil foram determinados em modo de ionização spray eletrônico negativo. Para cada pesticida foi encontrada duas transições (íon produtor-íon produzido) e confirmadas por MRM (Multiple Reaction Monitoring). O método apresentou linearidade com coeficientes de correlação maiores que 0,99. Uma metodologia para extração em fase sólida on line foi também desenvolvida. Essa metodologia apresentou-se altamente sensível (limites de detecção entre 0,040 e 2,794 ng L-1), simples rápida (45 minutos por análise) e precisa (desvio padrão relativo entre 1,99 e 12,15 %).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An analytical procedure using supercritical fluid extraction (SFE) and capillary gas chromatography with electron-capture detection was developed to determine simultaneously residues of different pesticides (organochlorine, organophosphorus, organonitrogen and pyrethroid) in honey samples. Fortification experiments were conducted to test conventional extraction (liquid-liquid) and optimize the extraction procedure in SFE by varying the CO2-modifier, temperature, extraction time and pressure. Best efficiency was achieved at 400 bar using acetonitrile as modifier at 90 degreesC. For the clean-up step, Florisil cartridges were used for both methods LLE and SFE. Recoveries for majority of pesticides from fortified samples of honey at fortification level of 0.01-0.10 mg/kg ranged 75-94% from both methods. Limits of detection found were less than 0.01 mg/kg for ECD and confirmation of pesticide identity was performed by gas chromatography-mass spectrometry in selected-ion monitoring mode. The multiresidue methods in real honey samples were applied and the results of developed methods were compared. (C) 2004 Elsevier B.V. All rights reserved.