932 resultados para relative spectrum distribution (RSD)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Máster en Oceanografía
Resumo:
In spite of the higher toxicity of oxygen-containing polycyclic aromatic hydrocarbons (OPAHs) than of their parent-PAHs, there are only a few studies of the concentrations, composition pattern, sources and fate of OPAHs in soil, the presumably major environmental sink of OPAHs. This is related to the fact that there are only few available methods to measure OPAHs together with PAHs in soil. rnThe objectives of my thesis were to (i) develop a GC/MS-based method to measure OPAHs and their parent-PAHs in soils of different properties and pollution levels, (ii) apply the method to soils from Uzbekistan and Slovakia and (iii) investigate into the fate of OPAHs, particularly their vertical transport in soilrnI optimized and fully evaluated an analytical method based on pressurized liquid extraction, silica gel column chromatographic fractionation of extracted compounds into alkyl-/parent-PAH and OPAH fractions, silylation of hydroxyl-/carboxyl-OPAHs with N,O-bis(trimethylsilyl)trifluoracetamide and GC/MS quantification of the target compounds. The method was targeted at 34 alkyl-/parent-PAHs, 7 carbonyl-OPAHs and 19 hydroxyl-/carboxyl-OPAHs. I applied the method to 11 soils from each of the Angren industrial region (which hosts a coal mine, power plant, rubber factory and gold refinery) in Uzbekistan and in the city of Bratislava, the densely populated capital of Slovakia.rnRecoveries of five carbonyl-OPAHs in spike experiments ranged between 78-97% (relative standard deviation, RSD, 5-12%), while 1,2-acenaphthenequinone and 1,4-naphtho-quinone had recoveries between 34-44%% (RSD, 19-28%). Five spiked hydroxyl-/carboxyl-OPAHs showed recoveries between 36-70% (RSD, 13-46%), while others showed recoveries <10% or were completely lost. With the optimized method, I determined, on average, 103% of the alkyl-/parent-PAH concentrations in a certified reference material.rnThe ∑OPAHs concentrations in surface soil ranged 62-2692 ng g-1 and those of ∑alkyl-/parent-PAHs was 842-244870 ng g-1. The carbonyl-OPAHs had higher concentrations than the hydroxyl-/carboxyl-OPAHs. The most abundant carbonyl-OPAHs were consistently 9-fluorenone (9-FLO), 9,10-anthraquinone (9,10-ANQ), 1-indanone (1-INDA) and benzo[a]anthracene-7,12-dione (7,12-B(A)A) and the most abundant hydroxyl-/carboxyl-OPAH was 2-hydroxybenzaldehyde. The concentrations of carbonyl-OPAHs were frequently higher than those of their parent-PAHs (e.g., 9-FLO/fluorene >100 near a rubber factory in Angren). The concentrations of OPAHs like those of their alkyl-/parent-PAHs were higher at locations closer to point sources and the OPAH and PAH concentrations were correlated suggesting that both compound classes originated from the same sources. Only for 1-INDA and 2-biphenylcarboxaldehyde sources other than combustion seemed to dominate. Like those of the alkyl-/parent-PAHs, OPAH concentrations were higher in topsoils than subsoils. Evidence of higher mobility of OPAHs than their parent-PAHs was provided by greater subsoil:topsoil concentration ratios of carbonyl-OPAHs (0.41-0.82) than their parent-PAHs (0.41-0.63) in Uzbekistan. This was further backed by the consistently higher contribution of more soluble 9-FLO and 1-INDA to the ∑carbonyl-OPAHs in subsoil than topsoil at the expense of 9,10-ANQ, 7,12-B(A)A and higher OPAH/parent-PAH concentration ratios in subsoil than topsoil in Bratislava.rnWith this thesis, I contribute a suitable method to determine a large number of OPAHs and PAHs in soil. My results demonstrate that carbonyl-OPAHs are more abundant than hydroxyl-/carboxyl-OPAHs and OPAH concentrations are frequently higher than parent-PAH concentrations. Furthermore, there are indications that OPAHs are more mobile in soil than PAHs. This calls for appropriate legal regulation of OPAH concentrations in soil.
Resumo:
This paper presents a new approach for reconstructing a patient-specific shape model and internal relative intensity distribution of the proximal femur from a limited number (e.g., 2) of calibrated C-arm images or X-ray radiographs. Our approach uses independent shape and appearance models that are learned from a set of training data to encode the a priori information about the proximal femur. An intensity-based non-rigid 2D-3D registration algorithm is then proposed to deformably fit the learned models to the input images. The fitting is conducted iteratively by minimizing the dissimilarity between the input images and the associated digitally reconstructed radiographs of the learned models together with regularization terms encoding the strain energy of the forward deformation and the smoothness of the inverse deformation. Comprehensive experiments conducted on images of cadaveric femurs and on clinical datasets demonstrate the efficacy of the present approach.
Resumo:
Introdução: Diante das mudanças nos hábitos de consumo alimentar da população brasileira, suplementos vitamínicos e alimentos enriquecidos são veículos comumente empregados para atender as necessidades de ingestão de micronutrientes. A diversidade de suplementos vitamínicos comercializados atualmente leva à necessidade de desenvolvimento de métodos analíticos de fácil execução e alta produtividade. Informações confiáveis sobre os teores de vitaminas poderão ser obtidas somente com métodos analíticos validados. Objetivos: Validar metodologias analíticas e avaliar o teor de vitaminas antioxidantes em suplementos adquiridos no comércio do município de São Paulo - Brasil, o efeito do armazenamento nestes compostos e confrontar os valores analisados com os valores declarados na rotulagem. Métodos: As metodologias analíticas para determinação de vitaminas antioxidantes por cromatografia líquida de alta eficiência com detector de arranjo de diodos (CLAE-DAD) e de vitamina C por titulação potenciométrica foram validadas para as matrizes sólidas, oleosas e líquidas de suplementos vitamínicos. A estabilidade das vitaminas foi avaliada a cada 6 meses durante 12 meses de armazenamento e a avaliação da rotulagem foi realizada de acordo com as legislações vigentes no Brasil. Resultados: Para os métodos cromatográficos, os limites de detecção (LDs) e de quantificação (LQs) variaram entre 0,3 e 4,3 µg/mL, e entre 0,5 e 14,0 µg/mL respectivamente. As recuperações dos padrões adicionados nas matrizes variaram entre 92 por cento e 109 por cento e entre 86 por cento e 108 por cento no material de referência. A repetitividade foi calculada pelo desvio padrão relativo (RSD), apresentando valores entre 0,2 por cento e 9,6 por cento . Para a determinação de vitamina C pelo método potenciométrico, o LD e o LQ foram respectivamente 1 mg e 3 mg; a recuperação no material de referência foi de 99,8 por cento e a precisão variou entre 0,4 e 3,9 por cento . Das 57 amostras avaliadas, 59 por cento e 35 por cento apresentaram teores de vitaminas A e E respectivamente, abaixo dos valores declarados no rótulo; por outro lado, 20 por cento das amostras apresentaram teores de vitamina E acima dos valores declarados. Em relação aos teores de vitamina C, 60 por cento das amostras estavam de acordo com os valores declarados. O estudo da estabilidade demonstrou degradação significativa das vitaminas A, E e C em aproximadamente 90 por cento das amostras com 12 meses de armazenamento. Na avaliação da rotulagem dos suplementos vitamínicos, 47 das amostras apresentaram uma ou mais irregularidades. Conclusão: Os métodos propostos se mostraram adequados para análise de diferentes matrizes de suplementos vitamínicos. Os resultados das análises de vitaminas nestes produtos mostraram a necessidade urgente de monitoramento em conjunto com ações de fiscalização, pois verificou-se que a maioria das amostras não atenderam a legislação, principalmente quanto aos teores declarados na informação nutricional da rotulagem. A sobredosagem de vitaminas pode ser necessária para manter os teores declarados durante o armazenamento, porém, a quantidade adicional de vitamina a ser incluída no suplemento deve estar dentro de limites seguros e depende de cada amostra, pois além da matriz, diversos fatores relacionados aos compostos e à embalagem também podem influenciar na estabilidade das vitaminas.
Resumo:
Langerhans cells (LCs) can be targeted with DNA-coated gold micro-projectiles ("Gene Gun") to induce potent cellular and humoral immune responses. It is likely that the relative volumetric distribution of LCs and keratinocytes within the epidermis impacts on the efficacy of Gene Gun immunization protocols. This study quantified the three-dimensional (3D) distribution of LCs and keratinocytes in the mouse skin model with a near-infrared multiphoton laser-scanning microscope (NIR-MPLSM). Stratum corneum (SC) and viable epidermal thickness measured with MPLSM was found in close agreement with conventional histology. LCs were located in the vertical plane at a mean depth of 14.9 mum, less than 3 mum above the dermo-epidermal boundary and with a normal histogram distribution. This likely corresponds to the fact that LCs reside in the suprabasal layer (stratum germinativum). The nuclear volume of keratinocytes was found to be approximately 1.4 times larger than that of resident LCs (88.6 mum3). Importantly, the ratio of LCs to keratinocytes in mouse ear skin (1:15) is more than three times higher than that reported for human breast skin (1:53). Accordingly, cross-presentation may be more significant in clinical Gene Gun applications than in pre-clinical mouse studies. These interspecies differences should be considered in pre-clinical trials using mouse models.
Resumo:
This issue of Philosophical Transactions of the Royal Society, Part A represents a summary of the recent discussion meeting 'Communication networks beyond the capacity crunch'. The purpose of the meeting was to establish the nature of the capacity crunch, estimate the time scales associated with it and to begin to find solutions to enable continued growth in a post-crunch era. The meeting confirmed that, in addition to a capacity shortage within a single optical fibre, many other 'crunches' are foreseen in the field of communications, both societal and technical. Technical crunches identified included the nonlinear Shannon limit, wireless spectrum, distribution of 5G signals (front haul and back haul), while societal influences included net neutrality, creative content generation and distribution and latency, and finally energy and cost. The meeting concluded with the observation that these many crunches are genuine and may influence our future use of technology, but encouragingly noted that research and business practice are already moving to alleviate many of the negative consequences.
Resumo:
The elemental analysis of soil is useful in forensic and environmental sciences. Methods were developed and optimized for two laser-based multi-element analysis techniques: laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and laser-induced breakdown spectroscopy (LIBS). This work represents the first use of a 266 nm laser for forensic soil analysis by LIBS. Sample preparation methods were developed and optimized for a variety of sample types, including pellets for large bulk soil specimens (470 mg) and sediment-laden filters (47 mg), and tape-mounting for small transfer evidence specimens (10 mg). Analytical performance for sediment filter pellets and tape-mounted soils was similar to that achieved with bulk pellets. An inter-laboratory comparison exercise was designed to evaluate the performance of the LA-ICP-MS and LIBS methods, as well as for micro X-ray fluorescence (μXRF), across multiple laboratories. Limits of detection (LODs) were 0.01-23 ppm for LA-ICP-MS, 0.25-574 ppm for LIBS, 16-4400 ppm for μXRF, and well below the levels normally seen in soils. Good intra-laboratory precision (≤ 6 % relative standard deviation (RSD) for LA-ICP-MS; ≤ 8 % for μXRF; ≤ 17 % for LIBS) and inter-laboratory precision (≤ 19 % for LA-ICP-MS; ≤ 25 % for μXRF) were achieved for most elements, which is encouraging for a first inter-laboratory exercise. While LIBS generally has higher LODs and RSDs than LA-ICP-MS, both were capable of generating good quality multi-element data sufficient for discrimination purposes. Multivariate methods using principal components analysis (PCA) and linear discriminant analysis (LDA) were developed for discriminations of soils from different sources. Specimens from different sites that were indistinguishable by color alone were discriminated by elemental analysis. Correct classification rates of 94.5 % or better were achieved in a simulated forensic discrimination of three similar sites for both LIBS and LA-ICP-MS. Results for tape-mounted specimens were nearly identical to those achieved with pellets. Methods were tested on soils from USA, Canada and Tanzania. Within-site heterogeneity was site-specific. Elemental differences were greatest for specimens separated by large distances, even within the same lithology. Elemental profiles can be used to discriminate soils from different locations and narrow down locations even when mineralogy is similar.
Resumo:
The purpose of this research was to develop a theory of high-energy exclusive electrodisintegration of three-nucleon systems on the example of 3He(e, e'NN)N reaction with knocked-out nucleon in the final state. The scattering amplitudes and differential cross section of the reaction were calculated in details within the Generalized Eikonal Approximation(GEA). The manifestly covariant nature of Feynman diagrams derived in GEA allowed us to preserve both the relativistic dynamics and kinematics of the scattering while identifying the low momentum nuclear part of the amplitude with a nonrelativistic nuclear wave function. Numerical calculations of the residual system's total and relative momentum distribution were performed which show reasonable agreement with available experimental data. The theoretical framework of GEA, which was applied previously only for the case of two-body (deuteron) high energy break up reactions, has been practically implemented and shown to provide a valid description for more complex A = 3 systems.
Resumo:
Produced water is a major problem associated with the crude oil extraction activity. The monitoring of the levels of metals in the waste is constant and requires the use of sensitive analytical techniques. However, the determination of trace elements can often require a pre-concentration step. The objective of this study was to develop a simple and rapid analytical method for the extraction and pre-concentration based on extraction phenomenon cloud point for the determination of Cd, Pb and Tl in produced water samples by spectrometry of high resolution Absorption source continues and atomization graphite furnace. The Box Behnken design was used to obtain the optimal condition of extraction of analytes. The factors were evaluated: concentration of complexing agent (o,o-dietilditilfosfato ammonium, DDTP), the concentration of hydrochloric acid and concentration of surfactant (Triton X -114). The optimal condition obtained through extraction was: 0,6% m v-1 DDTP, HCl 0,3 mol L-1 and 0,2% m v-1 of Triton X - 114 for Pb; 0,7% m v-1 DDTP, HCl 0,8 mol L-1 and 0,2% m v-1 Triton X-114 for Cd. For Tl was evidenced that best extraction condition occurs with no DDTP, the extraction conditions were HCl 1,0 mol L-1 e 1,0% m v-1 de Triton X - 114. The limits of detection for the proposed method were 0,005 µg L-1 , 0,03 µg L-1 and 0,09 µg L-1 to Cd, Pb and Tl, Respectively. Enrichment factors Were greater than 10 times. The method was applied to the water produced in the Potiguar basin, and addition and recovery tests were performed, and values were between 81% and 120%. The precision was expressed with relative standard deviation (RSD) is less than 5%
Resumo:
Cette thèse a pour sujet le développement d’un détecteur à fibre scintillante plastique pour la dosimétrie des faisceaux de photons de basses énergies. L’objectif principal du projet consiste à concevoir et caractériser cet instrument en vue de mesurer la dose de radiation reçue au cours des examens d’imagerie diagnostique et interventionnelle. La première section est consacrée à la conception de six différents systèmes et à l’évaluation de leur performance lorsqu’ils sont exposés à des rayonnements de hautes et basses énergies. Tous les systèmes évalués présentaient un écart type relatif (RSD) de moins de 5 % lorsqu’ils étaient exposés à des débits de dose de plus de 3 mGy/s. Cette approche systématique a permis de déterminer que le tube photomultiplicateur répondait le mieux aux conditions d’exposition propres à la radiologie. Ce dernier présentait une RSD de moins de 1 % lorsque le débit de dose était inférieur à 0.10 mGy/s. L’étude des résultats permis également de suggérer quelques recommandations dans le choix d’un système en fonction de l’application recherchée. La seconde partie concerne l’application de ce détecteur à la radiologie interventionnelle en procédant à des mesures de dose à la surface d’un fantôme anthropomorphique. Ainsi, plusieurs situations cliniques ont été reproduites afin d’observer la précision et la fiabilité du détecteur. Ce dernier conserva une RSD inférieure à 2 % lorsque le débit de dose était supérieur à 3 mGy/min et d’environ 10 % au débit le plus faible (0.25 mGy/min). Les mesures sur fantôme montrèrent une différence de moins de 4 % entre les mesures du détecteur et celles d’une chambre d’ionisation lors du déplacement de la table ou du bras de l’appareil de fluoroscopie. Par ailleurs, cette différence est demeurée sous les 2 % lors des mesures de débit de dose en profondeur. Le dernier sujet de cette thèse porta sur les fondements physiques de la scintillation dans les scintillateurs plastiques. Les différents facteurs influençant l’émission lumineuse ont été analysés afin d’identifier leur contribution respective. Ainsi, la réponse du détecteur augmente de près d’un facteur 4 entre un faisceau de 20 kVp et 250 kVp. De ce signal, la contribution de la fluorescence produite dans la fibre claire était inférieure à 0.5 % lorsque les fibres étaient exposées sur 10 cm par des faisceaux de 20 à 250 kVp. Le phénomène d’extinction de la fluorescence par ionisation a également été étudié. Ainsi, l’atténuation du signal variait en fonction de l’énergie du faisceau et atteignit environ 20 % pour un faisceau de 20 kVp. En conclusion, cette étude suggère que les détecteurs à fibres scintillantes peuvent mesurer avec précision la dose de radiation reçue en imagerie diagnostique et interventionnelle, mais une calibration rigoureuse s’avère essentielle.
Resumo:
Neste trabalho foi desenvolvido e validado um método analítico para a determinação de Fe total em amostras de água com diferentes salinidades empregando a microextração líquido-líquido dispersiva (DLLME), seguido de determinação espectrofotométrica na região do ultravioleta-visível. Nas extrações por DLLME, o Fe foi complexado com pirrolidina ditiocarbamato de amônio (APDC) e extraído após a injeção de uma mistura composta de 1,2-diclorobenzeno (solvente extrator) e etanol (solvente dispersor). Os fatores que influenciam a eficiência de extração (tipo e volume de solvente extrator e dispersor, concentração de APDC e tempo de extração) e subsequente determinação espectrofotométrica foram otimizados. Após otimização das condições, a curva de calibração foi linear entre 0,02 e 2,0 mg L-1 (r 2 = 0,9998) e os limites de detecção e quantificação do método foram de 6,1 e 18,3 µg L-1 , respectivamente. O fator de pré-concentração foi de 3,3. A exatidão foi avaliada em termos de recuperação, com variação entre 90 e 102% e desvio padrão relativo (RSD) inferiores a 12%. A exatidão do método também foi avaliada utilizando um material de referência certificado (SRM 1643e, Elementos Traço em Água), o qual apresentou concordância de 104% e RSD de 5%. O método foi aplicado para amostras de água com diferentes salinidades, como água mineral, estuarina e de alto mar. Além disso, o método proposto apresentou concordância da ordem de 95%, quando comparado com o método 1,10-fenantrolina para a determinação de Fe total.
Resumo:
Purpose: To evaluate the comparative efficiency of graphite furnace atomic absorption spectrometry (GFAAS) and hydride generation atomic absorption spectrometry (HGAAS) for trace analysis of arsenic (As) in natural herbal products (NHPs). Method: Arsenic analysis in natural herbal products and standard reference material was conducted using atomic absorption spectrometry (AAS), namely, hydride generation AAS (HGAAS) and graphite furnace (GFAAS). The samples were digested with HNO3–H2O2 in a ratio of 4:1 using microwaveassisted acid digestion. The methods were validated with the aid of the standard reference material 1515 Apple Leaves (SRM) from NIST Results: Mean recovery of three different samples of NHPs, using HGAAS and GFAAS, ranged from 89.3 - 91.4 %, and 91.7 - 93.0 %, respectively. The difference between the two methods was insignificant. A (P= 0.5), B (P=0.4) and C (P=0.88) Relative standard deviation (RSD) RSD, i.e., precision was 2.5 - 6.5 % and 2.3 - 6.7 % using HGAAS and GFAAS techniques, respectively. Recovery of arsenic in SRM was 98 and 102 % by GFAAS and HGAAS, respectively. Conclusion: GFAAS demonstrates acceptable levels of precision and accuracy. Both techniques possess comparable accuracy and repeatability. Thus, the two methods are recommended as an alternative approach for trace analysis of arsenic in natural herbal products.
Resumo:
The elemental analysis of soil is useful in forensic and environmental sciences. Methods were developed and optimized for two laser-based multi-element analysis techniques: laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and laser-induced breakdown spectroscopy (LIBS). This work represents the first use of a 266 nm laser for forensic soil analysis by LIBS. Sample preparation methods were developed and optimized for a variety of sample types, including pellets for large bulk soil specimens (470 mg) and sediment-laden filters (47 mg), and tape-mounting for small transfer evidence specimens (10 mg). Analytical performance for sediment filter pellets and tape-mounted soils was similar to that achieved with bulk pellets. An inter-laboratory comparison exercise was designed to evaluate the performance of the LA-ICP-MS and LIBS methods, as well as for micro X-ray fluorescence (μXRF), across multiple laboratories. Limits of detection (LODs) were 0.01-23 ppm for LA-ICP-MS, 0.25-574 ppm for LIBS, 16-4400 ppm for µXRF, and well below the levels normally seen in soils. Good intra-laboratory precision (≤ 6 % relative standard deviation (RSD) for LA-ICP-MS; ≤ 8 % for µXRF; ≤ 17 % for LIBS) and inter-laboratory precision (≤ 19 % for LA-ICP-MS; ≤ 25 % for µXRF) were achieved for most elements, which is encouraging for a first inter-laboratory exercise. While LIBS generally has higher LODs and RSDs than LA-ICP-MS, both were capable of generating good quality multi-element data sufficient for discrimination purposes. Multivariate methods using principal components analysis (PCA) and linear discriminant analysis (LDA) were developed for discriminations of soils from different sources. Specimens from different sites that were indistinguishable by color alone were discriminated by elemental analysis. Correct classification rates of 94.5 % or better were achieved in a simulated forensic discrimination of three similar sites for both LIBS and LA-ICP-MS. Results for tape-mounted specimens were nearly identical to those achieved with pellets. Methods were tested on soils from USA, Canada and Tanzania. Within-site heterogeneity was site-specific. Elemental differences were greatest for specimens separated by large distances, even within the same lithology. Elemental profiles can be used to discriminate soils from different locations and narrow down locations even when mineralogy is similar.