982 resultados para pulse stacking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Base-base interactions were computed for single- and double- stranded polynucleotides, for all possible base sequences. In each case, both right and left stacking arrangements are energetically possible. The preference of one over the other depends upon the base-sequence and the orientation of the bases with respect to helix-axis. Inverted stacking arrangement is also energetically possible for both single- and double-stranded polynucleotides. Finally, interaction energies of a regular duplex and the alternative structures3 were compared. It was found that the type II model3 is energetically more favourable than the rest.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stacking interactions in free bases were computed on the basis of molecular association. The results of the calculations were compared with the stacking patterns observed in a few single crystals of nucleic acid components as examples. The following are the conclusions: (i) there can be two types of stacking pattern classified as normal and inverted types for any two interacting bases and both can be energetically favourable (ii) in both the types the stacking interaction is a combined effect of the overlap of the interacting bases and relative positions and orientations of the atomic centres of the two bases (iii) crystal symmetry and H-bonding interaction may influence stacking patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The response of a third order non-linear system subjected to a pulse excitation is analysed. A transformation of the displacement variable is effected. The transformation function chosen is the solution of the linear problem subjected to the same pulse. With this transformation the equation of motion is brought into a form in which the method of variation of parameters is applicable for the solution of the problem. The method is applied to a single axis gyrostabilized platform subjected to an exponentially decaying pulse. The analytical results are compared with digital and analog computer solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High frequency, miniature, pulse tube cryocoolers are extensively used in space applications because of their simplicity. Parametric studies of inertance type pulse tube cooler are performed with different length-to-diameter ratios of the pulse tube with the help of the FLUENT (R) package. The local thermal non-equilibrium of the gas and the matrix is taken into account for the modeling of porous zones, in addition to the wall thickness of the components. Dynamic characteristics and the actual mechanism of energy transfer in pulse are examined with the help of the pulse tube wall time constant. The heat interaction between pulse tube wall and the oscillating gas, leading to surface heat pumping, is quantified. The axial heat conduction is found to reduce the performance of the pulse tube refrigerator. The thermal non-equilibrium predicts a higher cold heat exchanger temperature compared to thermal equilibrium. The pressure drop through the porous medium has a strong non-linear effect due to the dominating influence of Forchheimer term over that of the linear Darcy term at high operating frequencies. The phase angle relationships among the pressure, temperature and the mass flow rate in the porous zones are also important in determining the performance of pulse tuberefrigerator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has long been argued that better timing precision allowed by satellites like Rossi X-ray Timing Explorer (RXTE) will allow us to measure the orbital eccentricity and the angle of periastron of some of the bright persistent high-mass X-ray binaries (HMXBs) and hence a possible measurement of apsidal motion in these system. Measuring the rate of apsidal motion allows one to estimate the apsidal motion constant of the mass losing companion star and hence allows for the direct testing of the stellar structure models for these giant stars present in the HMXBs. In the present paper, we use the archival RXTE data of two bright persistent sources, namely Cen X-3 and SMC X-1, to measure the very small orbital eccentricity and the angle of periastron. We find that the small variations in the pulse profiles of these sources, rather than the intrinsic time resolution provided by RXTE, limit the accuracy with which we can measure arrival time of the pulses from these sources. This influences the accuracy with which one can measure the orbital parameters, especially the very small eccentricity and the angle of periastron in these sources. The observations of SMC X-1 in the year 2000 were taken during the high-flux state of the source and we could determine the orbital eccentricity and omega using this data set.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A numerical modelling technique for predicting the detailed performance of a double-inlet type two-stage pulse tube refrigerator has been developed. The pressure variations in the compressor, pulse tube, and reservoir were derived, assuming the stroke volume variation of the compressor to be sinusoidal. The relationships of mass flowrates, volume flowrates, and temperature as a function of time and position were developed. The predicted refrigeration powers are calculated by considering the effect of void volumes and the phase shift between pressure and mass flowrate. These results are compared with the experimental results of a specific pulse tube refrigerator configuration and an existing theoretical model. The analysis shows that the theoretical predictions are in good agreement with each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new method for establishing correlation between deuterium and its attached carbon in a deuterated liquid crystal. The method is based on transfer of polarization using the DAPT pulse sequence proposed originally for two spin half nuclei, now extended to a spin-1 and a spin-1/2 nuclei. DAPT utilizes the evolution of magnetization of the spin pair under two blocks of phase shifted BLEW-12 pulses on one of the spins separated by a 90 degree pulse on the other spin. The method is easy to implement and does not need to satisfy matching conditions unlike the Hartmann-Hahn cross-polarization. Experimental results presented demonstrate the efficacy of the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P-Nickel hydroxide comprises a long range periodic arrangement of atoms with a stacking sequence of AC AC AC-having an ideal composition Ni(OH)(2). Variation in the preparative conditions can lead to the changes in the stacking sequence (AC AC BA CB AC AC or AC AC AB AC AC) This type of variation in stacking sequence can result in the formation of stacking fault in nickel hydroxide. The stability of the stacking fault depends on the free energy content of the sample. Stacking faults in nickel hydroxide is essential for better electrochemical activity. Also there are reports correlating particle size to the better electrochemical activity. Here we present the effect of crystallite size on the stacking faulted nickel hydroxide samples. The electrochemical performance of stacking faulted nickel hydroxide with small crystallite size exchanges 0.8e/Ni, while the samples with larger crystallite size exchange 0.4e/Ni. Hence a right combination of crystallite size and stacking fault content has to be controlled for good electrochemical activity of nickel hydroxide. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A two stage Pulse Tube Cryocooler (PTC) is designed and fabricated which reaches a no-load temperature of 2.5K in the second stage and similar to 60 K in the first stage respectively. The system provides a cooling power of similar to 250 mW at 5K in the second stage. Stainless steel meshes (size 200) and lead (Pb) granules are used as the first stage regenerator materials and combination of Pb with Er3Ni / HoCu2 are used as the second stage regenerator materials. The system operates at 1.6 Hz using a 6 kW water cooled helium compressor. Studies conducted by varying the dimensions of Pulse Tubes and regenerators show that the dimensions of the Pulse Tubes are more critical to the performance of the Cryocooler than those of the regenerators. Experimental studies show that the optimum volume ratios of Er3Ni to Pb and HoCu2 to Pb in the second stage regenerator should be 3:2 and 2:3 respectively for the best performance. Further, systems with HoCu2 performed better than those with Er3Ni. The theoretical analysis of the system has been carried out using a simple isothermal model. The experimentally measured cooling powers are in good agreement with the theoretical predictions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is now realised (1,2,3) that a knowledge of stacking fault energy is fundamental for an understanding of the mechanical behaviour of metals. There are several processes in which the imperfect dislocations have to recombine locally to form an unextended dislocation . For intersection of two dislocations it is, for example, necessary to form 'constrictions'. Cross slip of extended dislocations also involves constriction. The onset of stage llI work hardening in a crystal with close-packed structure is attributed to cross slip and hence is controlled by the stacking fault energy (SPE). Methods of estimation of SFE are based on either the direct observation of stacking faults in an electron microscope or their effects on the deformation processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pulse-echo apparatus, designed and constructed by the author, has been used to reinvestigate the elastic properties of the eighteen optical glasses. The elastic constants are correct to 0·5%. The results are compared with the earlier investigation which utilised the optical method. The possible causes for large discrepancies observed are critically and briefly discussed. A qualitative interpretation of the results has been successfully attempted. The acoustic velocity increases with the decrease in lead and barium oxides and with increase in calcium oxide and boron trioxide components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An atmospheric radio noise burst represents the radiation received from one complete lightning flash at the frequency to which a receiver is tuned and within the receiver bandwidth. At tropical latitudes, the principal source of interference in the frequency range from 0.1 to 10 MHz is the burst form of atmospheric radio noise. The structure of a burst shows several approximately rectangular pulses of random amplitude, duration and frequency of recurrence. The influence of the noise on data communication can only be examined when the value of the number of pulses crossing a certain amplitude threshold per unit time of the noise burst is known. A pulse rate counter designed for this purpose has been used at Bangalore (12°58′N, 77°35′E) to investigate the pulse characteristics of noise bursts at 3 MHz with a receiver bandwidth of 3.3 kHz/6d B. The results show that the number of pulses lying in the amplitude range between peak and quasi-peak values of the noise bursts and the burst duration corresponding to these pulses follow log normal distributions. The pulse rates deduced therefrom show certain correlation between the number of pulses and the duration of the noise burst. The results are discussed with a view to furnish necessary information for data communication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Counting-rate meters normally used for finding pulse frequencies are sluggish in their response to any rapid change in the pulse repetition frequency (P.R.F.). An instrument is described which measures each pulse interval and provides immediately afterwards an output voltage proportional to the reciprocal of interval duration. A response to a change in the P.R.F. as rapidly as is physically possible is obtained. The instrument has wide application in low level radiation detection and in several other fields especially for rapidly varying counting-rates.