962 resultados para prosthesis and implants


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study examined the association between oral candidiasis in elderly users and nonusers of prosthesis and its predisposing factors. To this end, we performed a cross-sectional study where saliva samples from 48 patients were collected they used prosthesis and 43 patients (control group) who did not use. Among the 91 patients, Candida spp were isolated in 40 (83.3%) who used prosthesis and in 23 (53.5%) in the control group. A statistically significant association was determined between the two groups, the isolation of yeasts and dental prosthesis (p < 0.05, OR = 4.3). The most common etiological agent was Candida albicans (37 isolates), with 23 (62.2%) in the denture group and 14 (37.8%) (control group). Among patients who presented clinical manifestations of oral candidiasis (n = 24), 83.3% (n = 20) belonged to the group that wore dentures, while only 16.7% (n = 4) belonged to the control group. Elderly patients with diabetes had 4.4 times higher estimated risk of developing oral candidiasis when compared with individuals without this condition. There was no statistically significant association between being user prostheses and have diabetes with the onset of candidiasis. No statistically significant association was determined between xerostomia, use of prosthesis and oral candidiasis. The use of prosthetics and poor oral hygiene in elderly patients predisposes to the development of oral candidiasis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION: Mitral regurgitation (MR) is the most common valvular disease and has recently become the target of a number of percutaneous approaches. The MitraClip is virtually the only device for which there is considerable experience, with more than 20,000 procedures performed worldwide. OBJECTIVE: To describe our initial experience of the percutaneous treatment of MR with the MitraClip device. METHODS: We describe the first six MitraClip cases performed in this institution (mean age 58.5 ± 13.1 years), with functional MR grade 4+ and New York Heart Association (NYHA) heart failure class III or IV (n=3), with a mean follow-up of 290 ± 145 days. RESULTS: Procedural success (MR ≤ 2+) was 100%. Total procedure time was 115.8 ± 23.7 min, with no in-hospital adverse events and discharge between the fourth and eighth day, and consistent improvement in the six-minute walk test (329.8 ± 98.42 vs. 385.33 ± 106.95 m) and in NYHA class (three patients improved by two NYHA classes). During follow-up there were two deaths, in two of the four patients who had been initially considered for heart transplantation. CONCLUSION: In patients with functional MR the MitraClip procedure is safe, with both a high implantation and immediate in-hospital success rate. A longer follow-up suggests that the clinical benefit decreases or disappears completely in patients with more advanced heart disease, namely those denied transplantation or on the heart transplant waiting list.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Large intrathoracic airway defects may be closed using a pedicled latissimus dorsi (LD) flap, with rewarding results. This study addresses the question of whether this holds true for extrathoracic non-circumferential tracheal defects. METHODS: A cervical segment of the trachea of 4 x 1 cm was resected in 9 white male pigs. The defect was stented with a silicone stent for 3 months and closed either by an LD flap alone (group a, n = 3), an LD flap with an attached rib segment covered by pleura (group b, n = 3), or an LD flap reinforced by a perforated polylactide (MacroPore) plate (group c, n = 3). The trachea was assessed by rigid endoscopy at 3 and 4 months and histologically at 4 months postoperatively. RESULTS: The degree of stenosis at the level of the reconstruction at 4 months was 25, 50 and 75% in group a, 15, 50 and 60% in group b, and 20, 95 and 95% in group c, respectively. The percentage of the defect covered by columnar epithelium was 100% in all animals of group a, 60, 100 and 100% in group b, and 10, 0 and 0% in group c. Resorption of the rib was seen in all animals of group b and obstructive inflammatory polyps were found in 2 animals of group c. CONCLUSION: Pedicled LD flaps provided less satisfactory results for closure of large non-circumferential extrathoracic airway defects than observed after intrathoracic reconstruction. A pedicled rib segment added to the LD flap did not improve the results obtained from LD flap repair alone, and an embedded MacroPore prosthesis may result in severe airway stenosis due to plate migration and intense inflammatory reaction protruding into the tracheal lumen.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: All patients with extensive resection of the anterolateral chest wall and the sternum followed by reconstruction with methylmethacrylate substitutes were assessed prospectively 6 months after the operation to delineate chest wall integrity with pulmonary function and cine-magnetic resonance imaging. METHODS: Twenty-six patients underwent chest wall reconstruction by use of methylmethacrylate between 1994 and 1998 due to primary tumors in 35%, metastases in 27%, T3 lung cancer in 19%, and debridement for radionecrosis and osteomyelitis in 19% of patients. Three to eight ribs were resected and additional sternum resection was performed in 39% of patients. RESULTS: There was no 30-day mortality. All patients were extubated after the operation without need for reintubation. Prosthesis dislocation occurred in 1 patient and infection in 2 patients during follow-up. Nineteen patients (73%) suffered no restrictions of daily activities. Clinical examination revealed normal shoulder girdle function in 77% of patients. There was no significant difference between preoperative and postoperative FEV1 (forced expiratory volume in 1 second) measurements in patients with lobectomy or wedge resections. Cinemagnetic resonance imaging revealed concordant chest wall movements during respiration in 92% of patients without paradoxical movements or implant dislocations being observed. CONCLUSIONS: Large defects of the anterolateral chest wall and sternum can be reconstructed efficiently with methylmethacrylate substitutes with minimal morbidity and excellent cosmetic and functional outcome.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Evidence shows that the endocannabinoid system modulates the addictive properties of nicotine. In the present study, we hypothesized that spontaneous withdrawal resulting from removal of chronically implanted transdermal nicotine patches is regulated by the endocannabinoid system. A 7-day nicotine dependence procedure (5.2 mg/rat/day) elicited occurrence of reliable nicotine abstinence symptoms in Wistar rats. Somatic and affective withdrawal signs were observed at 16 and 34 hours following removal of nicotine patches, respectively. Further behavioral manifestations including decrease in locomotor activity and increased weight gain also occurred during withdrawal. Expression of spontaneous nicotine withdrawal was accompanied by fluctuation in levels of the endocannabinoid anandamide (AEA) in several brain structures including the amygdala, the hippocampus, the hypothalamus and the prefrontal cortex. Conversely, levels of 2-arachidonoyl-sn-glycerol were not significantly altered. Pharmacological inhibition of fatty acid amide hydrolase (FAAH), the enzyme responsible for the intracellular degradation of AEA, by URB597 (0.1 and 0.3 mg/kg, i.p.), reduced withdrawal-induced anxiety as assessed by the elevated plus maze test and the shock-probe defensive burying paradigm, but did not prevent the occurrence of somatic signs. Together, the results indicate that pharmacological strategies aimed at enhancing endocannabinoid signaling may offer therapeutic advantages to treat the negative affective state produced by nicotine withdrawal, which is critical for the maintenance of tobacco use.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND A catheter-based approach after fibrinolysis is recommended if fibrinolysis is likely to be successful in patients with acute ST-elevation myocardial infarction. We designed a 2x2 randomized, open-label, multicenter trial to evaluate the efficacy and safety of the paclitaxel-eluting stent and tirofiban administered after fibrinolysis but before catheterization to optimize the results of this reperfusion strategy. METHODS AND RESULTS We randomly assigned 436 patients with acute ST-elevation myocardial infarction to (1) bare-metal stent without tirofiban, (2) bare-metal stent with tirofiban, (3) paclitaxel-eluting stent without tirofiban, and (4) paclitaxel-eluting stent with tirofiban. All patients were initially treated with tenecteplase and enoxaparin. Tirofiban was started 120 minutes after tenecteplase in those patients randomly assigned to tirofiban. Cardiac catheterization was performed within the first 3 to 12 hours after inclusion, and stenting (randomized paclitaxel or bare stent) was applied to the culprit artery. The primary objectives were the rate of in-segment binary restenosis of paclitaxel-eluting stent compared with that of bare-metal stent and the effect of tirofiban on epicardial and myocardial flow before and after mechanical revascularization. At 12 months, in-segment binary restenosis was similar between paclitaxel-eluting stent and bare-metal stent (10.1% versus 11.3%; relative risk, 1.06; 95% confidence interval, 0.74 to 1.52; P=0.89). However, late lumen loss (0.04+/-0.055 mm versus 0.27+/-0.057 mm, P=0.003) was reduced in the paclitaxel-eluting stent group. No evidence was found of any association between the use of tirofiban and any improvement in the epicardial and myocardial perfusion. Major bleeding was observed in 6.1% of patients receiving tirofiban and in 2.7% of patients not receiving it (relative risk, 2.22; 95% confidence interval, 0.86 to 5.73; P=0.14). CONCLUSIONS This trial does not provide evidence to support the use of tirofiban after fibrinolysis to improve epicardial and myocardial perfusion. Compared with bare-metal stent, paclitaxel-eluting stent significantly reduced late loss but appeared not to reduce in-segment binary restenosis. CLINICAL TRIAL REGISTRATION URL: http://clinicaltrials.gov. Unique identifier: NCT00306228.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

INTRODUCTION: The femoral periprosthetic fracture of the knee is one of the most feared complications because of its repercussions. Incidence are more and more likely due to the increase of total implanted arthroplasty of the knee, due to the increasing lifespan among the general population. The objective of this study is to analyze some of the perioperative aspects of the treatment of these fractures, comparing the use of osteosynthesis with plates and the retrograde nailing in those patients with femoral periprosthetic knee fractures with a stable implant. MATERIAL AND METODS: The study retrospectively examines 18 cases treated consecutively in our hospital (3 men and 15 women, average age of 72.7 years) between the years of 2000 and 2009. All fractures were located in the distal femur and on a stable implant. Eight were treated through retrograde nailing (Group I) and ten with plates (Group II). The cases are analyzed through the tests of the University of Mann-Withney and the exact Fischer test, with significant values of p≤0.05, the variables of median hospital stay, necessity of transfusion indicated with values of hemoglobin less than 8 mg/ml, preoperative radiological alignment and postoperative alignment of the total knee prosthesis (TKR), measured following the anatomical tibiofemoral axis, time of consolidation and incidence of localized complications in both groups. RESULTS: We did not find any statistically significant differences between the two groups in any of the variables analyzed. Localized complications are more frequent in Group I (62.5 percent of patients) than in Group II (10 percent of patients). The need for transfusion is greater in Group II (40 percent) than in Group I (12.5 percent). CONCLUSIONS: The type of implant used in treatment of femoral periprosthetic knee fracture does not significantly influence perioperative factors. The treatment for this type of fractures should be individually chosen in relation to the type of fracture, characteristics of the patient and stability and prosthesis model of the primary knee.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: Assess the degree of satisfaction in a series of patients between 50 and 60 years of age who underwent surgery in our unicompartmental prosthesis unit (UPU) for monocompartmental gonarthrosis. Likewise, the definition based on current literature is assessed, as well as our experience in the indications, inconveniences and results of the internal knee unicompartmental arthroplasty discussed with supra-tuberosity tibial osteotomy, which was the common surgical option in these cases.MATERIAL AND METHOD: This study included 19 patients between 50 and 60 years of age (average age 56.7 years) (Interval of 51-60 years) intervened between 7/2007 and 11/2011 by the same surgeon (GDFB). Functional assessment used the Oxford Knee Score (OKS) questionnaire. A bibliographic search was performed in the MEDLINE, COCHRANE and EMBASE databases from 1988 to 2012. RESULTS: With an average follow-up of 29.4 months, 16 of 19 patients stated that they were satisfied with the results obtained and would repeat the intervention. One patient sufered a prosthetic infection and was reviewed for total knee replacement with good results. CONCLUSIONS: the medial, unicompartmental arthroplasty of the knee is a valid surgical option and reproducible in the medium term treatment of monocompartmental gonarthrosis in patients between 50 and 60 years of age.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Lower limb amputees exhibit postural control deficits during standing which can affect their walking ability. OBJECTIVES The primary purpose of the present study was to analyze the thorax, pelvis, and hip kinematics and the hip internal moment in the frontal plane during gait in subjects with Unilateral Transtibial Amputation (UTA). METHOD The participants included 25 people with UTA and 25 non-amputees as control subjects. Gait analysis was performed using the Vicon(r) Motion System. We analyzed the motion of the thorax, pelvis, and hip (kinematics) as well as the hip internal moment in the frontal plane. RESULTS The second peak of the hip abductor moment was significantly lower on the prosthetic side than on the sound side (p=.01) and the control side (right: p=.01; left: p=.01). During middle stance, the opposite side of the pelvis was higher on the prosthetic side compared to the control side (right: p=.01: left: p=.01). CONCLUSIONS The joint internal moment at the hip in the frontal plane was lower on the prosthetic side than on the sound side or the control side. Thorax and pelvis kinematics were altered during the stance phase on the prosthetic side, presumably because there are mechanisms which affect postural control during walking.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives: In patients with lateral osteoarthritis of the knee, use of external unicompartmental knee arthroplasty it is a well known surgical alternative, used by the minor trauma involved, short hospital stay and rapid recovery. The purpose of this study is to show the clinical outcomes to short-medium term of patients undergoing this procedure. Methods: we describe the technique used and the peculiarities of the prosthesis (A Mobile-bearing lateral unicompartmental knee replacement, Oxford Domed ®). This is an observational retrospective longitudinal study, of 15 arthroplasties performed in 13 women and 2 men, between 2010 and 2013, with a mean age of 60’7 years, with a diagnosis of lateral osteoarthritis of the knee, without involvement of the medial or patellofemoral compartment and cruciate ligaments functionally intact, with a mean follow up of 25 months. All patients complete the Oxford Knee Score and Visual Analog Scale (VAS) during the study. Results: The results are favorable, with an improvement of 6.60 points on the EVA, 3.73 for 1 in the postoperatory funcionality, the OKS very satisfactory with an average of 38 points over 50 and without any postoperative function surgical revision. Anserine tendinitis was observed in 20% of cases. Conclusions: The benefits of this surgery against their alternatives are assessed, and their potential drawbacks. External unicompartmental knee arthroplasty is an effective alternative in cases of knee osteoarthritis of the lateral compartment with no other associated injuries.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: The vascular access steal syndrome is a complication occurring in 1-6% after native arterio-venous (AV) fistulas, often due to huge diameter of the vein. This results in very high flow, which could also be responsible for cardiac overload. The aim of this study is to evaluate the efficiency of a new approach in the treatment of this pathology using open-pore external scaffolding prosthesis.Methods: This a retrospective review of all patients presenting symptomatic high flow after native AV fistula between January 2007 and December 2009 in 3 vascular centers. Pre-operative duplex exam confirmed the diagnosis of high flow. The operation consisted in preparation of the whole fistula, measurement of the flow and section on the venous side. The vein was wrapped with this 6 to 8 mm open-pore external scaffolding prosthesis (ProVena, BBraun, Germany) according to its diameter and to the flow and then sutured. Measurement of the flow was repeated. Patients were followed by duplex exam at 1 week and at 1, 3, 6 and 12 months. Procedural success was defined as complete implantation of the prosthesis and reduction of the flow. Primary outcomes were reduction of the flow and recovery of the symptoms and secondary endpoint was patency of the fistula.Results: During the study period, 14 patients, with a mean age of 65・8 years old, have been operated with this technique.There were 2 native forearmfistulas and 12 on the armwith a mean pre-operative flow of 2600 ml/min (1800-3800). The mode of presentation was pain in 6 patients, neurological disorders in 10 and necrosis in 4. Moreover, 3 patients had cardiac insufficiency due to high flow in the fistula. The procedure was technically successful in 100% of cases. Re-intervention was necessary in 2 patients due to hematoma. Recovery of the initial symptoms occurred in 13 patients (93%). The mean flow reduction was 1200 ml/min (600-2000). In 1 patient, a persistent steal syndrome despite flow reduction to 1400 ml/min resulted in fistula closure 2 months later. At a mean follow-up of 22 months (4-35), all remaining patients (13/14) presented a patent fistula without recurrence.Conclusion: This new approach seems to be safe and effective in the treatment of symptomatic high flow native AV fistulas by significantly reducing the flow and avoiding closure of the vascular access. Longer follow-up with more patients are necessary to evaluate the risk of recurrence.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Polyethylene wear is a recurrent problem in joint arthroplasty. Small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. The goal of this study was thus to estimate the volume of polyethylene wear of a reversed prosthesis, and compare it to an anatomic prosthesis, during one year of activities of daily living. Material and Methods: A numerical musculoskeletal model of the glenohumeral joint was used for this comparative study. The reversed (RP) and anatomic (AP) Aequalis prostheses were positioned in the numerical model. Eight levels of abduction were considered. Their daily frequency was estimated from in-vivo recorded data on healthy volunteers during activities of daily living. One year of use was simulated to predict the linear and volumetric wear. The volumetric wear was the difference of volume between the original and worn component. Results: With the AP, the contact pattern on the glenoid surface moved rapidly from the inferior to the superior side during the first 30 degrees of abduction, and then went back to the inferior side. With the RP, the contact pattern on the humeral cup surface remained at the inferior side. Contact pressure was 20 times lower with the RP than with the AP. One year of use produced a maximum linear wear of 0.2 mm with the AP, and 0.13 mm with the RP. However, the volumetric wear was 8.4 mm3 with the AP, but reached 44.6 mm3 with the RP. Conclusion: Polyethylene particles are a matter of concern with AP. Infiltration of these particles within the bone-implant interface can induce a implant loosening. This problem should not be underestimated with RP. It might be associated to a higher level of humeral stem loosening reported with RP. The long term survival of RP might be improved by using a highly cross-linked polyethylene, which has a better abrasion resistance but lower plastic resistance.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.