936 resultados para precision limit
Resumo:
A validação metodológica permite evidenciar se os resultados obtidos por um método são confiáveis, tornando-se um elemento essencial na qualidade. Neste estudo, cujo objectivo é validar a metodologia enzimática para determinação de oxalato na urina, incluíram-se 30 amostras de urina de 24horas, pré-tratadas e estudadas em dois auto-analisadores. Os valores dos limites de detecção e quantificação foram 0,98 e 0,79 mg/L, respectivamente. Para a exactidão obteve-se p=0,713. Na precisão intermédia entre corridas não existem diferenças estatisticamente significativas, em oposição às repetições. Para a linearidade obteve-se r=1 e a sensibilidade foi 0,6%. Conclui-se que o método se mostrou exacto e linear.
Resumo:
Bacterial food poisoning is an ever-present threat that can be prevented with proper care and handling of food products. A disposable electrochemical immunosensor for the simultaneous measurements of common food pathogenic bacteria namely Escherichia coli O157:H7 (E. coli), campylobacter and salmonella were developed. The immunosensor was fabricated by immobilizing the mixture of anti-E. coli, anticampylobacter and anti-salmonella antibodies with a ratio of 1:1:1 on the surface of the multiwall carbon nanotube-polyallylamine modified screen printed electrode (MWCNT-PAH/SPE). Bacteria suspension became attached to the immobilized antibodies when the immunosensor was incubated in liquid samples. The sandwich immunoassay was performed with three antibodies conjugated with specific nanocrystal ( -E. coli-CdS, -campylobacter-PbS and -salmonella-CuS) which has releasable metal ions for electrochemical measurements. The square wave anodic stripping voltammetry (SWASV) was employed to measure released metal ions from bound antibody nanocrystal conjugates. The calibration curves for three selected bacteria were found in the range of 1 × 103 – 5 × 105 cells mL−1 with the limit of detection (LOD) 400 cells mL−1 for salmonella, 400 cells mL−1 for campylobacter and 800 cells mL−1 for E. coli. The precision and sensitivity of this method show the feasibility of multiplexed determination of bacteria in milk samples.
Resumo:
A QuEChERS method has been developed for the determination of 14 organochlorine pesticides in 14 soils from different Portuguese regions with wide range composition. The extracts were analysed by GC-ECD (where GC-ECD is gas chromatography-electron-capture detector) and confirmed by GC-MS/MS (where MS/MS is tandem mass spectrometry). The organic matter content is a key factor in the process efficiency. An optimization was carried out according to soils organic carbon level, divided in two groups: HS (organic carbon>2.3%) and LS (organic carbon<2.3%). Themethod was validated through linearity, recovery, precision and accuracy studies. The quantification was carried out using a matrixmatched calibration to minimize the existence of the matrix effect. Acceptable recoveries were obtained (70–120%) with a relative standard deviation of ≤16% for the three levels of contamination. The ranges of the limits of detection and of the limits of quantification in soils HS were from 3.42 to 23.77 μg kg−1 and from 11.41 to 79.23 μg kg−1, respectively. For LS soils, the limits of detection ranged from 6.11 to 14.78 μg kg−1 and the limits of quantification from 20.37 to 49.27 μg kg−1. In the 14 collected soil samples only one showed a residue of dieldrin (45.36 μg kg−1) above the limit of quantification. This methodology combines the advantages of QuEChERS, GC-ECD detection and GC-MS/MS confirmation producing a very rapid, sensitive and reliable procedure which can be applied in routine analytical laboratories.
Resumo:
A produção de vinho é uma actividade de elevada importância ao nível económico, ambiental e social. Como tal, a protecção da vinha e/ou da uva através da utilização de pesticidas assume um papel fundamental nesta actividade, permitindo um aumento no rendimento da produção. No entanto, a transferência destes compostos da uva para o vinho é inevitável, ocorrendo, na maioria dos casos, em quantidades reduzidas. Apesar de, geralmente, a quantidade de pesticidas que pode ser transferida para o vinho não apresentar problemas relevantes para a saúde pública, o desenvolvimento de metodologias que permitam garantir um controlo rigoroso da qualidade do vinho é de elevada importância. O controlo deste produto, assim como de qualquer produto alimentar, não deve ser de certa forma virtual, levando a uma desconfiança crescente do consumidor. Ao longo deste trabalho foram desenvolvidos dois métodos para a determinação de pesticidas em diferentes tipos de vinhos, por SPME-GC-MS/MS. O primeiro método desenvolvido visa a determinação de 8 pesticidas organofosforados e o segundo método permite a determinação de 7 pesticidas, 4 organoclorados e 3 dicarboximidas. Foram estudadas quatro matrizes diferentes: vinho branco do Douro, vinho tinto do Douro, vinho branco do Porto e vinho tinto do Porto. As metodologias adoptadas permitiram a obtenção de bons resultados, apesar das condições adoptadas não serem as mais vantajosas para alguns dos compostos estudados. Dada a complexidade das matrizes, a detecção por espectrometria de massa mostrou ser fundamental para a identificação inequívoca de cada um dos pesticidas. Verificaram-se, de um modo geral, bons resultados ao nível da linearidade, para as gamas de concentrações escolhidas, para os dois métodos. Obtiveram-se também bons resultados para os limites de detecção e quantificação, cujos valores se situam abaixo dos limites máximos de resíduos para as uvas, impostos pela regulamentação europeia, para a maioria dos compostos. No caso dos organofosforados, os limites de detecção variam entre 0,05 μg/L e 13,00 μg/L para os pesticidas clorpirifos-metilo e metidatião, respectivamente. Os limites de quantificação variam entre 0,18 μg/L e 43,32 μg/L, também para os pesticidas clorpirifos-metilo e metidatião. No que se refere ao método para os pesticidas organoclorados e dicarboximidas, foram calculados vários limites de detecção para cada composto, em cada matriz estudada, a partir das rectas de calibração diárias, resultando num conjunto de valores com variações significativas entre cada um, para o mesmo pesticida e na mesma matriz. No entanto, apenas os limites de quantificação foram validados, recorrendo-se aos estudos de repetibilidade e precisão intermédia. Obtiveram-se os seguintes limites de quantificação: captana 52,10 μg/L; clortalonil 20,95 μg/L; dicofol 4,37 μg/L; folpete 93,60 μg/L; iprodiona 274,70 μg/L; procimidona 76,04 μg/L e vinclozolina 10,03 μg/L. Os pesticidas metidatião e captana apresentam-se como os compostos mais problemáticos, uma vez que os limites de quantificação obtidos não permitem a garantia do cumprimento dos limites máximos de resíduos regulamentados. Demonstra-se também que, apesar do efeito de matriz ser significativo na determinação de todos os compostos analisados, o mesmo pode ser atenuado, procedendo-se às calibrações nas respectivas matrizes. Observaram-se variações significativas ao nível da resposta do equipamento ao longo do tempo, quer pela alteração das condições operatórias, quer pela decomposição de alguns compostos ao longo do tempo. Este efeito, evidenciado nos estudos das precisões intermédias e repetibilidades, levou à adopção de um método de validação diferente para a determinação de pesticidas organoclorados e dicarboximidas, recorrendo-se então a calibrações diárias e sequências de trabalho mais pequenas.
Resumo:
A simple, rapid, and precise amperometric method for quantification of N-methylcarbamate pesticides in water samples and phytopharmaceuticals is presented. Carbofuran and fenobucarb are the target analytes. The method is developed in flow conditions providing the anodic oxidation of phenolic-based compounds formed after alkaline hydrolysis. Optimization of instrumental and chemical variables is presented. Under the optimal conditions, the amperometric signal is linear for carbofuran and fenobucarb concentrations over the range of 1.0*10-7 to 1.0*10-5 molL-1, with a detection limit of about 2 ngmL-1. The amperometric method is successfully applied to the analysis of spiked environmental waters and commercial formulations. The proposed method allows 90 samples to be analysed per hour, using 500 mL of sample, and producing wastewaters of low toxicity. The proposed method permits determinations at the mgL 1 level and offers advantages of simplicity, accuracy, precision, and applicability to coloured and turbid samples, and automation feasibility.
Resumo:
The electrochemical behavior of citalopram was studied by square-wave and square-wave adsorptive-stripping voltammetry (SWAdSV). Citalopram can be reduced and accumulated at a mercury drop electrode, with a maximum peak current intensity being obtained at a potential of approximately -1.25V vs. AgCl/Ag, in an aqueous electrolyte solution of pH 12. A SWAdSV method has been developed for the determination of citalopram in pharmaceutical preparations. The method shows a linear range between 1.0x10-7 and 2.0x10-6 mol L-1 with a limit of detection of 5x10-8 mol L-1 for an accumulation time of 30 s. The precision of the method was evaluated by assessing the repeatability and intermediate precision, achieving good relative standard deviations in all cases (≤2.3%). The proposed method was applied to the determination of citalopram in five pharmaceutical products and the results obtained are in good agreement with the labeled values.
Resumo:
A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs.
Resumo:
Amulti-residue methodology based on a solid phase extraction followed by gas chromatography–tandem mass spectrometry was developed for trace analysis of 32 compounds in water matrices, including estrogens and several pesticides from different chemical families, some of them with endocrine disrupting properties. Matrix standard calibration solutions were prepared by adding known amounts of the analytes to a residue-free sample to compensate matrix-induced chromatographic response enhancement observed for certain pesticides. Validation was done mainly according to the International Conference on Harmonisation recommendations, as well as some European and American validation guidelines with specifications for pesticides analysis and/or GC–MS methodology. As the assumption of homoscedasticity was not met for analytical data, weighted least squares linear regression procedure was applied as a simple and effective way to counteract the greater influence of the greater concentrations on the fitted regression line, improving accuracy at the lower end of the calibration curve. The method was considered validated for 31 compounds after consistent evaluation of the key analytical parameters: specificity, linearity, limit of detection and quantification, range, precision, accuracy, extraction efficiency, stability and robustness.
Resumo:
The Quinone outside Inhibitors (QoI) are one of the most important and recent fungicide groups used in viticulture and also allowed by Integrated Pest Management. Azoxystrobin, kresoxim-methyl and trifloxystrobin are the main active ingredients for treating downy and powdery mildews that can be present in grapes and wines. In this paper, a method is reported for the analysis of these three QoI-fungicides in grapes and wine. After liquid–liquid extraction and a clean-up on commercial silica cartridges, analysis was by isocratic HPLC with diode array detection (DAD) with a run time of 13 min. Confirmation was by solid-phase micro-extraction (SPME), followed by GC/MS determination. The main validation parameters for the three compounds in grapes and wine were a limit of detection up to 0.073mg kg-1, a precision not exceeding 10.0% and an average recovery of 93% ±38.
Resumo:
This paper presents a single precision floating point arithmetic unit with support for multiplication, addition, fused multiply-add, reciprocal, square-root and inverse squareroot with high-performance and low resource usage. The design uses a piecewise 2nd order polynomial approximation to implement reciprocal, square-root and inverse square-root. The unit can be configured with any number of operations and is capable to calculate any function with a throughput of one operation per cycle. The floatingpoint multiplier of the unit is also used to implement the polynomial approximation and the fused multiply-add operation. We have compared our implementation with other state-of-the-art proposals, including the Xilinx Core-Gen operators, and conclude that the approach has a high relative performance/area efficiency. © 2014 Technical University of Munich (TUM).
Resumo:
The oxidative behaviour of fluoxetine was studied at a glassy carbon electrode in various buffer systems and at different pH using cyclic, differential pulse and square wave voltammetry. A new square wave voltammetric method suitable for the quality control of fluoxetine in commercial formulations has been developed using a borate pH 9 buffer solution as supporting electrolyte. Under optimized conditions, a linear response was obtained in the range 10 to 16 μM with a detection limit of 1.0 μM. Validation parameters such as sensitivity, precision and accuracy were evaluated. The proposed method was successfully applied to the determination of fluoxetine in pharmaceutical formulations. The results were statistically compared with those obtained by the reference high-performance liquid chromatographic method. No significant differences were found between the methods.
Resumo:
O bacalhau (Gadus morhua) faz parte da dieta alimentar dos portugueses há vários séculos, sendo atualmente, um dos maiores consumidores deste peixe a nível mundial. Após o processo de salga, esta espécie possui características únicas como a consistência, cheiro, paladar e cor amarela. É precisamente devido à coloração do peixe que alguns produtores da Islândia, Noruega e Dinamarca requisitaram às autoridades da União Europeia (UE) a aprovação da utilização de polifosfatos no processo de salga húmida do bacalhau. Os polifosfatos são aditivos alimentares bastante usados no processamento do pescado pois previnem a oxidação dos lípidos e proteínas do músculo do bacalhau, evitando assim a indesejada mudança de cor do peixe. Apesar dos esforços da Associação dos Industriais do Bacalhau (AIB) e do governo português para a rejeição da proposta nórdica, tal não se verificou. Deste modo, no início do próximo ano já será possível a venda na UE de bacalhau com fosfatos. A quantificação do teor de fosfatos no bacalhau é geralmente efetuada por Espetrofotometria de absorção molecular no ultravioleta-visível (UV-Visível). Esta quantificação é baseada no método de determinação do fósforo total, através da hidrólise dos fosfatos a ortofosfatos com posterior medição da cor amarela, gerada pela reação destes com uma solução de molibdato-vanadato. O objetivo desta dissertação foi a validação de um método de análise para a quantificação dos polifosfatos no bacalhau. O método validado foi o descrito na norma NP 4495 para produtos de pesca e aquicultura. O desenvolvimento deste trabalho foi realizado em laboratório acreditado para águas e produtos alimentares (Equilibrium - Laboratório de Controlo de Qualidade e de Processos Lda, L0312). Foi ainda determinada a influência do teor de cloreto de sódio na quantificação dos polifosfatos e o teor de humidade, uma vez que este pode afetar o produto durante a sua comercialização. No processo de validação do método foram estudados diversos parâmetros, tais como a seletividade, linearidade, sensibilidade, limite de quantificação e precisão. Pela análise dos resultados obtidos conclui-se que o método para determinação de fosfatos no bacalhau se encontra validado, uma vez que satisfaz todas as especificações determinadas para cada parâmetro de validação avaliado.
Resumo:
A Norfloxacina (NFX) é um antibiótico antibacteriano indicado para combater bactérias Gram-negativas e amplamente utilizado para o tratamento de infeções no trato respiratório e urinário. Com a necessidade de realizar estudos clínicos e farmacológicos esenvolveram-se métodos de análise rápida e sensitiva para a determinação da Norfloxacina. Neste trabalho foi desenvolvido um novo sensor eletroquímico sensível e seletivo para a deteção da NFX. O sensor foi construído a partir de modificações efetuadas num elétrodo de carbono vítreo. Inicialmente o elétrodo foi modificado com a deposição de uma suspensão de nanotubos de carbono de paredes múltiplas (MWCNT) de modo a aumentar a sensibilidade de resposta analítica. De seguida um filme polímerico molecularmente impresso (MIP) foi preparado por eletrodeposição, a partir de uma solução contendo pirrol (monómero funcional) e NFX (template). Um elétrodo de controlo não impresso foi também preparado (NIP). Estudouse e caraterizou-se a resposta eletroquímica do sensor para a oxidação da NFX por voltametria de onda quadrada. Foram optimizados diversos parâmetros experimentais, tais como, condições ótimas de polimerização, condições de incubação e condições de extração. O sensor apresenta um comportamento linear entre a intensidade da corrente do pico e o logaritmo da concentração de NFX na gama entre 0,1 e 8μM. Os resultados obtidos apresentam boa precisão, com repetibilidade inferior a 6% e reprodutibilidade inferior a 9%. Foi calculado a partir da curva de calibração um limite de deteção de 0,2 μM O método desenvolvido é seletivo, rápido e de fácil manuseamento. O sensor molecularmente impresso foi aplicado com sucesso na deteção da NFX em amostras de urina real e água.
Resumo:
This article investigates the limit cycle (LC) prediction of systems with backlash by means of the describing function (DF) when using discrete fractional-order (FO) algorithms. The DF is an approximate method that gives good estimates of LCs. The implementation of FO controllers requires the use of rational approximations, but such realizations produce distinct dynamic types of behavior. This study analyzes the accuracy in the prediction of LCs, namely their amplitude and frequency, when using several different algorithms. To illustrate this problem we use FO-PID algorithms in the control of systems with backlash.
Resumo:
The use of robotic vehicles for environmental modeling is discussed. This paper presents diverse results in autonomous marine missions with the ROAZ autonomous surface vehicle. The vehicle can perform autonomous missions while gathering marine data with high inertial and positioning precision. The underwater world is an, economical and environmental, asset that need new tools to study and preserve it. ROAZ is used in marine environment missions since it can sense and monitor the surface and underwater scenarios. Is equipped with a diverse set of sensors, cameras and underwater sonars that generate 3D environmental models. It is used for study the marine life and possible underwater wrecks that can pollute or be a danger to marine navigation. The 3D model and integration of multibeam and sidescan sonars represent a challenge in nowadays. Adding that it is important that robots can explore an area and make decisions based on their surroundings and goals. Regard that, autonomous robotic systems can relieve human beings of repetitive and dangerous tasks.