994 resultados para oxygen saturation


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine the effects of temazepam on the quality of sleep and on oxygen saturation during sleep in subjects at high altitude.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the response of healthy infants to airway hypoxia (15% oxygen in nitrogen).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Retinal vessel oxygenation saturation measurements have been the focus of much attention in recent years as a potential diagnostic parameter in a number of ocular and systemic pathologies. This interest has been heightened by the ability to measure oxygen saturation in vivo using a photographic technique. METHODS: Retinal vessel oxygenation in venules and arterioles of 279 retinal vessels of 12 healthy Caucasian participants (mean age: 30 SD (+/- 6) years) were measured consecutively three times to evaluate short-term variation in oxygen saturation and regional variability of retinal vessel oxygen saturation using dual-wavelength technology (Oxymetry Modul, Imedos, Germany). All subjects underwent standard optometric assessment including non-contact intra-ocular pressure assessment as well as having their systemic blood pressure measured. RESULTS: Vessels were grouped as either near-macula or peripheral, depending on their location. Peripheral arterioles and venules exhibited significantly lower oxygen saturation compared to their near-macula counterparts (arterioles: 94.7% (SD 3.9) vs. 99.7% (SD 3.2); venules: 65.1% (SD 7.2) vs. 90.3% (SD 6.7)). Both arterioles and venules, main branches, and those feeding and draining the retina near the macula and periphery showed low short-term variability of oxygen saturation (arterioles: COV 1.2-1.8%; venules: COV 2.9-4.9%). CONCLUSIONS: Retinal arterioles and venules exhibit low short-term variation of oxygen saturation in healthy subjects. Regional differences in oxygen saturation could be a potential useful marker for risk stratification and diagnostic purposes of area-specific retinal pathology such as age-related macula degeneration and diabetic maculopathy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, a new entropy measure known as kernel entropy (KerEnt), which quantifies the irregularity in a series, was applied to nocturnal oxygen saturation (SaO 2) recordings. A total of 96 subjects suspected of suffering from sleep apnea-hypopnea syndrome (SAHS) took part in the study: 32 SAHS-negative and 64 SAHS-positive subjects. Their SaO 2 signals were separately processed by means of KerEnt. Our results show that a higher degree of irregularity is associated to SAHS-positive subjects. Statistical analysis revealed significant differences between the KerEnt values of SAHS-negative and SAHS-positive groups. The diagnostic utility of this parameter was studied by means of receiver operating characteristic (ROC) analysis. A classification accuracy of 81.25% (81.25% sensitivity and 81.25% specificity) was achieved. Repeated apneas during sleep increase irregularity in SaO 2 data. This effect can be measured by KerEnt in order to detect SAHS. This non-linear measure can provide useful information for the development of alternative diagnostic techniques in order to reduce the demand for conventional polysomnography (PSG). © 2011 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To establish the optimal flash settings for retinal vessel oxygen saturation parameters using dual-wavelength imaging in a multiethnic group. METHODS. Twelve healthy young subjects (mean age 32 years [SD 7]; three Mediterranean, two South Asian, and seven Caucasian individuals) underwent retinal vessel oxygen saturation measurements using dual-wavelength oximetry, noncontact tonometry, and manual sphygmomanometry. In order to evaluate the impact of flash intensity, we obtained three images (fundus camera angle 30°, ONH centered) per flash setting. Flash settings of the fundus camera were increased in steps of 2 (initial setting of 6 and the final of 22), which reflect logarithmic increasing intensities from 13.5 to 214 Watt seconds (Ws). RESULTS. Flash settings below 27 Ws were too low to obtain saturation measurements, whereas flash settings of more than 214 Ws resulted in overexposed images. Retinal arteriolar and venular oxygen saturation was comparable at flash settings of 27 to 76 Ws (arterioles' range: 85%-92%; venules' range: 45%-53%). Higher flash settings lead to increased saturation measurements in both retinal arterioles (up to 110%) and venules (up to 92%), with a more pronounced increase in venules. CONCLUSIONS. Flash intensity has a significant impact on retinal vessel oxygen saturation measurements using dual-wavelength retinal oximetry. High flash intensities lead to supranormal oxygen saturation measurements with a magnified effect in retinal venules compared with arteries. In addition to even retinal illumination, the correct flash setting is of paramount importance for clinical acquisition of images in retinal oximetry. We recommend flash settings between 27 to 76 Ws. © 2013 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVES: Hemodynamic support is aimed at providing adequate O-2 delivery to the tissues; most interventions target O-2 delivery increase. Mixed venous O-2 saturation is a frequently used parameter to evaluate the adequacy of O-2 delivery. METHODS: We describe a mathematical model to compare the effects of increasing O-2 delivery on venous oxygen saturation through increases in the inspired O-2 fraction versus increases in cardiac output. The model was created based on the lungs, which were divided into shunted and non-shunted areas, and on seven peripheral compartments, each with normal values of perfusion, optimal oxygen consumption, and critical O-2 extraction rate. O-2 delivery was increased by changing the inspired fraction of oxygen from 0.21 to 1.0 in steps of 0.1 under conditions of low (2.0 L.min(-1)) or normal (6.5 L.min(-1)) cardiac output. The same O-2 delivery values were also obtained by maintaining a fixed O-2 inspired fraction value of 0.21 while changing cardiac output. RESULTS: Venous oxygen saturation was higher when produced through increases in inspired O-2 fraction versus increases in cardiac output, even at the same O-2 delivery and consumption values. Specifically, at high inspired O-2 fractions, the measured O-2 saturation values failed to detect conditions of low oxygen supply. CONCLUSIONS: The mode of O-2 delivery optimization, specifically increases in the fraction of inspired oxygen versus increases in cardiac output, can compromise the capability of the "venous O-2 saturation" parameter to measure the adequacy of oxygen supply. Consequently, venous saturation at high inspired O-2 fractions should be interpreted with caution.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nasopharyngeal oxygen (NPO) therapy may overcome some of the difficulties associated with nasal prongs and facemask oxygen delivery devices. In response to a lack of published studies of NPO therapy in adults, we conducted a prospective randomised crossover trial to compare the effectiveness of NPO, nasal prongs (NP) and facemasks (FM) when used in an adult population (n=37) from the intensive care unit and general hospital wards. We measured oxygen saturation (Sp[O.sub.2]) using pulse oximetry, oxygen flow (litres per minute), respiration rate (per minute) and comfort using a horizontal visual analogue scale. All three devices were effective in maintaining a Sp[O.sub.2] of [greater than or equal to]95% (NP 97.0[+ or -]1.9, NPO 97.7[+ or -]1.7, FM 98.8[+ or -]1.3%). NPO therapy consumed less oxygen than NP and FM therapy (NP 2.6[+ or -]1.0, NPO 2.2[+ or -]0.9, FM 6.1[+ or -]0.4 l/min, P <0.001). There was no significant difference in patients' respiratory rates (NP 19.9[+ or -]3.2, NPO 19.9[+ or -]3.0, FM 19.8[+ or -]3.1 per minute, P=0.491). In terms of comfort, patients rated NP higher than NPO and FM using a horizontal visual analogue scale (100 mm=most comfortable) (NP 65.5[+ or -]14.3, NPO 62.8[+ or -]19.4, FM 49.4[+ or -]21.4 mm, P <0.001). We conclude that for adult patients, nasal prongs and nasopharyngeal oxygen therapy consume less oxygen and provide greater comfort than facemasks while still maintaining Sp[O.sub.2] [greater than or equal to]95%.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: To describe how intensive care nurses manage the administration of supplemental oxygen to patients during the first 24 hours after cardiac surgery.
METHODS: A retrospective audit was conducted of the medical records of 245 adult patients who underwent cardiac surgery between 1 January 2005 and 31 May 2008 in an Australian metropolitan hospital. Physiological data (oxygen saturation measured by pulse oximetry and respiratory rate) and intensive care unit management data (oxygen delivery device, oxygen flow rate and duration of mechanical ventilation) were collected at hourly intervals over the first 24 hours of ICU care.
RESULTS: Of the 245 patients whose records were audited, 185 were male; mean age was 70 years (SD, 10), and mean APACHE II score was 17.5 (SD, 5.14). Almost half the patients (122, 49.8%) were extubated within 8 hours of ICU admission. The most common oxygen delivery device used immediately after extubation was the simple face mask (214 patients, 87%). Following extubation, patients received supplemental oxygen via, on average, two different delivery devices (range, 1-3), and had the delivery device changed an average of 1.38 times (range, 0-6) during the 24 hours studied. Twenty-two patients (9%) received non-invasive ventilation or high-flow oxygen therapy, and 16 (7%) experienced one or more episode of hypoxaemia during mechanical ventilation. A total of 148 patients (60%) experienced one or more episodes of low oxygenation or abnormal respiratory rate during the first 24 hours of ICU care despite receiving supplemental oxygen.
CONCLUSION: These findings suggest that the ICU environment does not protect cardiac surgical patients from suboptimal oxygen delivery, and highlights the need for strategies to prompt the early initiation of interventions aimed at optimising blood oxygen levels in cardiac surgical patients in the ICU.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Inconsistencies in oxygen therapy recommendations in acute exacerbation of chronic obstructive pulmonary disease (COPD) may result in variability in emergency department (ED) oxygen management of patients with COPD. The aim of this study was to describe oxygen management in the first 4 h of ED care for patients with exacerbation of COPD.
Methods: A retrospective medical record audit was conducted at four public and one private ED in Melbourne, Australia. Participants were 273 adult ED patients with COPD presenting with a primary complaint of shortness of breath from July 2006 to July 2007. Outcome measures were physiological data, including oxygen saturation (SpO2), oxygen delivery devices and flow rates on ED arrival, 1 and 4 h.
Results: Oxygen was used in 82.0% of patients. Patients who required oxygen had higher incidence of ambulance transport (P < 0.001), triage category 2 (P = 0.006), home oxygen use (P < 0.001), and increased work of breathing on ED arrival (P < 0.001), and higher median respiratory rate (P < 0.001) and heart rate (P = 0.001). SpO2 > 90% occurred in the majority of patients (87.5%; 96.4%; 95.6%); however, a considerable number of patients with SpO2 < 90% were not given oxygen (61.8%; 30%; 45.5%).
Conclusions: A number of patients with documented hypoxaemia were not given oxygen and there may be variables other than oxygen saturation that may influence oxygen use. Future research should focus on increasing the evidence-based supporting
oxygen use and better understanding of clinicians’ oxygen decision-making in patients with COPD.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Maintaining an adequate tissue oxygen delivery (DO(2)) and consumption (VO(2)) is crucial in the treatment of septic patients. A fall in V0(2) is associated with a higher mortality. The early recognition of shock or tissue hypo perfusion impacts on patient prognosis. In occasions, hypovolemia or important regional oxygen debts are not recognized, since macro homodynamic variables have been compensated. In this situation, the use of metabolic hypo perfusion markers such as lactate, central venous oxygen saturation and gastric goniometry, can be helpful. However, interpretation of these markers should be cautious and always considering the overall clinical status of the patient. In the initial stages of sepsis, the dependency of V0(2) on DO(2) predominates as histopathological mechanism of multiple organic failure. In late stages, other factors predominate as determinants of multiple organic failure and mortality, such as hyper or hypo immune response, microcirculatory alterations and cytopathic hypoxia.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate the effects on intestinal oxygen supply, and mucosal tissue oxygen tension during haemorrhage and after fluid resuscitation with either blood (B; n=7), gelatine (G; n=8), or lactated Ringer's solution (R; n=8) in an autoperfused, innervated jejunal segment in anaesthetized pigs. METHODS: To induce haemorrhagic shock, 50% of calculated blood volume was withdrawn. Systemic haemodynamics, mesenteric venous and systemic acid-base and blood gas variables, and lactate measurements were recorded. A flowmeter was used for measuring mesenteric arterial blood flow. Mucosal tissue oxygen tension (PO(2)muc), jejunal microvascular haemoglobin oxygen saturation (HbO(2)) and microvascular blood flow were measured. Measurements were performed at baseline, after haemorrhage and at four 20 min intervals after fluid resuscitation. After haemorrhage, animals were retransfused with blood, gelatine or lactated Ringer's solution until baseline pulmonary capillary wedge pressure was reached. RESULTS: After resuscitation, no significant differences in macrohaemodynamic parameters were observed between groups. Systemic and intestinal lactate concentration was significantly increased in animals receiving lactated Ringer's solution [5.6 (1.1) vs 3.3 (1.1) mmol litre(-1); 5.6 (1.1) vs 3.3 (1.2) mmol litre(-1)]. Oxygen supply to the intestine was impaired in animals receiving lactated Ringer's solution when compared with animals receiving blood. Blood and gelatine resuscitation resulted in higher HbO(2) than with lactated Ringer's resuscitation after haemorrhagic shock [B, 43.8 (10.4)%; G, 34.6 (9.4)%; R, 28.0 (9.3)%]. PO(2)muc was better preserved with gelatine resuscitation when compared with lactated Ringer's or blood resuscitation [20.0 (8.8) vs 13.8 (7.1) mm Hg, 15.2 (7.2) mm Hg, respectively]. CONCLUSION: Blood or gelatine infusion improves mucosal tissue oxygenation of the porcine jejunum after severe haemorrhage when compared with lactated Ringer's solution.