938 resultados para non-additivity of Faradaic current
Resumo:
The major problems associated with the use of corticosteroids for the treatment of ocular diseases are their poor intraocular penetration to the posterior segment when administered locally and their secondary side effects when given systemically. To circumvent these problems more efficient methods and techniques of local delivery are being developed. The purposes of this study were: (1) to investigate the pharmacokinetics of intraocular penetration of hemisuccinate methyl prednisolone (HMP) after its delivery using the transscleral Coulomb controlled iontophoresis (CCI) system applied to the eye or after intravenous (i.v.) injection in the rabbit, (2) to test the safety of the CCI system for the treated eyes and (3) to compare the pharmacokinetic profiles of HMP intraocular distribution after CCI delivery to i.v. injection. For each parameter evaluated, six rabbit eyes were used. For the CCI system, two concentrations of HMP (62.5 and 150mg ml(-1)), various intensities of current and duration of treatment were analyzed. In rabbits serving as controls the HMP was infused in the CCI device but without applied electric current. For the i.v. delivery, HMP at 10mg kg(-1)as a 62.5mg ml(-1)solution was used. The rabbits were observed clinically for evidence of ocular toxicity. At various time points after the administration of drug, rabbits were killed and intraocular fluids and tissues were sampled for methylprednisolone (MP) concentrations by high pressure liquid chromatography (HPLC). Histology examinations were performed on six eyes of each group. Among groups that received CCI, the concentrations of MP increased in all ocular tissues and fluids in relation to the intensities of current used (0.4, 1.0 and 2.0mA/0.5cm(2)) and its duration (4 and 10min). Sustained and highest levels of MP were achieved in the choroid and the retina of rabbit eyes treated with the highest current and 10min duration of CCI. No clinical toxicity or histological lesions were observed following CCI. Negligible amounts of MP were found in ocular tissues in the CCI control group without application of current. Compared to i.v. administration, CCI achieved higher and more sustained tissue concentrations with negligible systemic absorption. These data demonstrate that high levels of MP can be safely achieved in intraocular tissues and fluids of the rabbit eye, using CCI. With this system, intraocular tissues levels of MP are higher than those achieved after i.v. injection. Furthermore, if needed, the drug levels achieved with CCI can be modulated as a function of current intensity and duration of treatment. CCI could therefore be used as an alternative method for the delivery of high levels of MP to the intraocular tissues of both the anterior and posterior segments.
Resumo:
This paper studies non-autonomous Lyness type recurrences of the form x_{n+2}=(a_n+x_n)/x_{n+1}, where a_n is a k-periodic sequence of positive numbers with prime period k. We show that for the cases k in {1,2,3,6} the behavior of the sequence x_n is simple(integrable) while for the remaining cases satisfying k not a multiple of 5 this behavior can be much more complicated(chaotic). The cases k multiple of 5 are studied separately.
Resumo:
This paper studies non-autonomous Lyness type recurrences of the form xn+2 = (an+xn+1)=xn, where fang is a k-periodic sequence of positive numbers with primitive period k. We show that for the cases k 2 f1; 2; 3; 6g the behavior of the sequence fxng is simple (integrable) while for the remaining cases satisfying this behavior can be much more complicated (chaotic). We also show that the cases where k is a multiple of 5 present some di erent features.
Resumo:
In the thesis the principle of work of eddy current position sensors and the main cautions that must be taken into account while sensor design process are explained. A way of automated eddy current position sensor electrical characteristics measurement is suggested. A prototype of the eddy current position sensor and its electrical characteristics are investigated. The results obtained by means of the automated measuring system are explained.
Resumo:
Drought is the main constraint on wheat yield in Mediterranean conditions. The photosynthesis, chlorophyll fluorescence and plant growth parameters of durum wheat (Triticum turgidum, L. var. durum) were compared at three [CO2] (i.e., depleted 260 ppm, current 400ppm and elevated 700 ppm) in plants subjected to twowater regimes (i.e.,well-wateredWW, and mildwater stress by drought orwater deficit WS), during pre-anthesis, post-anthesis and the end of grain filling. We showed that [CO2] effects on plants are modulated by water availability. Plants at depleted [CO2] showed photosynthetic acclimation (i.e., up-regulation) and reduced plant biomass and Harvest Index, but depleted [CO2] combined with WS has a more negative impact on plants with decreases in C assimilation and biomass. Plants at elevated [CO2] had decreased plant growth and photosynthesis in response to a down-regulation mechanism resulting from a decrease in Rubisco and N content, but plants exposed to a combination of elevated [CO2] and WS were the most negatively affected (e.g., on plant biomass).
Resumo:
In the work eddy current sensors are described and evaluated. Theoretical part includes physical basics of the eddy currents, overview of available commercial products and technologies. Industrial sensors operation was assessed based on several working modes. Apart from this, the model was created in Matlab Simulink with Xilinx Blockset and then translated into a Xilinx ISE Design Suite compatible project. The performance of the resulting implementation was compared to the existing implementation in the Xilinx Spartan 3 FPGA board with the custom made sensor. Additionally, an introduction to FPGAs and VHDL is presented.
Resumo:
The herbicide metolachlor was evaluated for genotoxic potential. Metolachlor did not induce micronuclei in mice, however at 40 mg/kg it significantly decreased the percentage of polychromatic erythrocytes, which is a cytotoxic effect. Metolachlor did not induce chromosomal aberrations in human lymphocytes in vitro, but 2.0 mug/ml culture medium resulted in cytotoxicity, decreasing the mitotic index significantly. The indirect exposure test was carried out by adding plasma from metolachlor-pretreated rats to the human lymphocyte cultures. There was no indication of clastogenicity by metolachlor metabolites. On the other hand, plasma of cyclophosphamide-pretreated rats had a significant clastogenic effect
Resumo:
Abstract This descriptive study sought to identify the similarities and differences between the various educational institutions offering therapeutic recreation curriculum across Canada. The study utilized mixed methods, including open and closed-ended questions on a survey and document analysis. The research participants were from 14 educational institutions located across the nation. Results from this study identify similarities and differences in the curriculum used to prepare students pursuing a career in the TR field. Core competencies and standards of practice for the field of therapeutic recreation were defined and discussed. Accreditation and the accrediting bodies in the field of TR are reviewed because of their significant impact on curriculum. Implications regarding certification and regulation pertaining to the education for therapeutic recreation practitioners were discussed along with suggestions for future research.
Resumo:
The application vistas of superconductors have widened very much since the discovery of high TC superconductors (HTS) as many of the applications can be realised at 77 K rather than going down to 4.2 K, the liquid He temperature. One such application is the HTS current lead which is used to connect a superconducting system with a room temperature power source. Minimising heat leak to the cryogenic environment is the main advantage of introducing current leads into superconducting systems. The properties of HTSS likes zero resistance (avoiding joule heating) and very low thermal conductivity (minimized conductive heat transfer) make them ideal candidates to be used as current leads. There are two forms of HTS current leads. (i) bulk form (tube or rod) prepared either from YBCO or BSCCO and (ii) tape form prepared from Bi-2223 multifilamentary tapes. The tape form of current leads has many advantages with respect to the mechanical and thermal stability related criteria. Crucial information on various aspects of HTS current lead development are not available in the literature as those are kept proprietary by various companies around the world. The present work has been undertaken to tailor the properties of multifilamentary tapes for the current lead application and to optimise the processing parameters of the same for enhanced critical current density and field tolerance. Also it is the aim of the present investigation is to prepare prototype current leads engineered for operation in conduction cooled mode and test them for operational stability