Analysis of co-current hydraircooling of food products in bulk


Autoria(s): Rao, Narasimha KV; Narasimham, GSVL; Murthy, Krishna MV
Data(s)

01/09/1992

Resumo

A mathematical model is developed to describe the hydraircooling process when the water and air are flowing in the same direction. The governing equations for the simultaneous heat and mass transfer are solved using finite-difference numerical methods. The half cooling time of the food products is correlated as a function of the dimensionless process parameters. It is observed that a process time of approximately double the half cooling time will result in the food products attaining almost a steady state. The process times of the bulk hydraircooling process and the bulk air precooling process are compared.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/34714/1/Analysis_of_co-current.pdf

Rao, Narasimha KV and Narasimham, GSVL and Murthy, Krishna MV (1992) Analysis of co-current hydraircooling of food products in bulk. In: International Journal of Heat and Fluid Flow, 13 (3). pp. 300-310.

Publicador

Elsevier science

Relação

http://dx.doi.org/10.1016/0142-727X(92)90044-A

http://eprints.iisc.ernet.in/34714/

Palavras-Chave #Mechanical Engineering
Tipo

Journal Article

PeerReviewed