Aim-To develop an expert system model for the diagnosis of fine needle aspiration cytology (FNAC) of the breast.

Methods-Knowledge and uncertainty were represented in the form of a Bayesian belief network which permitted the combination of diagnostic evidence in a cumulative manner and provided a final probability for the possible diagnostic outcomes. The network comprised 10 cytological features (evidence nodes), each independently linked to the diagnosis (decision node) by a conditional probability matrix. The system was designed to be interactive in that the cytopathologist entered evidence into the network in the form of likelihood ratios for the outcomes at each evidence node.

Results-The efficiency of the network was tested on a series of 40 breast FNAC specimens. The highest diagnostic probability provided by the network agreed with the cytopathologists' diagnosis in 100% of cases for the assessment of discrete, benign, and malignant aspirates. A typical probably benign cases were given probabilities in favour of a benign diagnosis. Suspicious cases tended to have similar probabilities for both diagnostic outcomes and so, correctly, could not be assigned as benign or malignant. A closer examination of cumulative belief graphs for the diagnostic sequence of each case provided insight into the diagnostic process, and quantitative data which improved the identification of suspicious cases.

Conclusion-The further development of such a system will have three important roles in breast cytodiagnosis: (1) to aid the cytologist in making a more consistent and objective diagnosis; (2) to provide a teaching tool on breast cytological diagnosis for the non-expert; and (3) it is the first stage in the development of a system capable of automated diagnosis through the use of expert system machine vision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the adverse effect of intravitreal injection of normal saline (NS) and phosphate buffered saline (PBS) in mouse eyes.

Methods: NS or PBS was injected intravitreally into C57BL/6J mouse eyes. Retinal lesions were monitored by fundus imaging, spectral-domain optical coherence tomography (SD-OCT), and histological investigations. Retinal immune gene expression was determined by real-time polymerase chain reaction (PCR). The toxic effect of NS and PBS or retinal protein from NS- or PBS-injected eyes on retinal pigment epithelium (RPE) was tested in B6-RPE-07 mouse RPE cell cultures.

Results: Intravitreal injection of NS dose-dependently induced localized retinal lesion in mice. Histological investigations revealed multiple vacuoles in photoreceptor outer segments and RPE cells. The lesions recovered over time and by 3 weeks post injection the majority of lesions vanished in eyes receiving 1 μl NS. Inflammatory genes, including TNF-α, IL-1β, IL-6, iNOS, and VEGF were upregulated in NS injected eyes. Intravitreal injection of PBS did not cause any pathology. The treatment of B6-RPE07 cells with 30% PBS or 30% NS did not affect RPE viability. However, incubation of 1-μg/ml retinal protein from NS-injected eyes, but not PBS-injected eyes induced RPE cell death.

Conclusion: NS is toxic to the C57BL/6J mouse retina and should not be used as a vehicle for intraocular injection. PBS is not toxic to the retina and is a preferred vehicle.

Translational Relevance: NS is not a physiological solution for intraocular injection in the C57BL/6J mice and questions its suitability for intraocular injection in other species, including human.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To assess the efficacy and safety of periprostatic lignocaine injection in trans-rectal ultrasound (TRUS) -guided biopsy of the prostate gland.

Methods: Ninety- six men (mean age 65 years, range 47-74) undergoing TRUS biopsy were randomised into the local anaesthetic (LA) or placebo group. Six to twelve biopsy cores were taken, the majority being 10 cores. Patients were asked to fill in the expected pain score on a visual analogue scale (VAS) prior to the procedure. They also completed the actual pain experienced on VAS after the biopsy. The incidence of complications was documented.

Results: The age, mean prostate specific antigen (PSA) were comparable in both groups. The expected pain score was also comparable (5.2 +/- 1.6 in LA, 5.0 +/- 1.4 in Placebo). In the LA group, the mean actual pain score was 3.0 +/- 1.8 and in the placebo group it was 6.5 +/- 2.2 (P = 0.0001). When patients were asked whether they would undergo the procedure again in the same way, 100% of the LA group and only 64% of the placebo group responded 'yes'(P=0.002 using Fisher's test). The complication rates were not significantly different between the two groups.

Conclusion: Peri-prostatic injection of local anaesthetic is safe and reduces discomfort significantly, and should be routinely offered to patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel manufacturing process for fabricating microneedle arrays (MN) has been designed and evaluated. The prototype is able to successfully produce 14 × 14 MN arrays and is easily capable of scale-up, enabling the transition from laboratory to industry and subsequent commercialisation. The method requires the custom design of metal MN master templates to produce silicone MN moulds using an injection moulding process. The MN arrays produced using this novel method was compared with centrifugation, the traditional method of producing aqueous hydrogel-forming MN arrays. The results proved that there was negligible difference between either methods, with each producing MN arrays with comparable quality. Both types of MN arrays can be successfully inserted in a skin simulant. In both cases the insertion depth was approximately 60% of the needle length and the height reduction after insertion was in both cases approximately 3%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Monitoring of emerging modes of drug consumption in France has identified new patterns of injection among youths with diverse social backgrounds, which may explain the persistence of high rates of hepatitis C virus infection. The circumstances surrounding the first injection have been poorly documented in the group of heavy drug users and in the context of the French opioid substitution treatment (OST) policy that provides expanded access to high-dosage buprenorphine (BHD). Methods: An Internet survey (Priminject) was conducted from October 2010 to March 2011 with French drug users. Four time periods were compared based on critical dates throughout the implementation of the Harm Reduction Policy in France. Results: Compared with drug users who injected for the first time prior to 1995, the aspects of drug use for users who recently injected for the first time were as follows: (1) experimentation with miscellaneous drugs before the first injection; (2) an older age at the time of first injection; (3) heroin as the drug of choice for an individual’s first injection, notwithstanding the increased usage of stimulant drugs; (4) BHD did not appear to be a pathway to injection; and (5) an increased number of users who injected their first time alone, without the help or presence of another individual. Conclusion: The PrimInject study showed that there is a group of injection drug users that is larger than the group of injection drug users observed in previous studies; therefore, it is necessary to diversify programs to reach the entire spectrum of high-risk users.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Retinal pigment epithelium (RPE) tear is an extremely rare complication in patients with classic neovascular membranes without RPE detachment. We evaluate their incidence and functional outcome following treatment with intravitreal ranibizumab. METHODS: Observational study of 72 consecutive patients (74 eyes) treated at Jules Gonin University Eye Hospital, Lausanne, with intravitreal ranibizumab 0.5 mg for classic choroidal neovascularization (CNV) between March 2006 and February 2008. Best-corrected visual acuity (BCVA), fundus examination and optical coherence tomography were recorded monthly; fluorescein angiography was performed at baseline and repeated at least every 3 months. RESULTS: RPE tears occurred in four (5.4%) eyes temporal to the fovea, after a mean of four injections (range 3-6). Mean baseline BCVA was 0.25 decimal equivalent (logMAR 0.67) and improved despite the RPE tear to 0.6 decimal equivalent (logMAR 0.22). CONCLUSION: RPE tears following intravitreal ranibizumab injections for classic CNV can occur in about 5% of patients, even in the absence of baseline RPE detachment. Nevertheless, vision may improve provided the fovea is not involved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Skeletal Muscle Biopsy is a minor surgical procedure for the diagnosis of different neuromuscular pathological conditions and has recently gained popularity also in the research field of age-related muscular modifications and sarcopenia. Few studies focused on the application of mini-invasive muscular biopsy in both normal and pathological conditions. The aim of our study was to describe a mini invasive ultrasound-guided skeletal muscular biopsy technique in complete spinal cord injured (SCI) patients and healthy controls with a tri-axial end-cut needle. PATIENTS AND METHODS: Skeletal muscle biopsies were collected from 6 chronic SCI patients and 3 healthy controls vastus lateralis muscle with a tri-axial end cut needle (Biopince© - Angiotech). Muscle samples were stained for ATPase to determine fibers composition, moreover, gene expression of cyclooxygenase-1 (COX-1) and prostaglandin E2 receptor has been analyzed by Real Time RT-PCR. RESULTS: All the procedures were perfomed easily without failures and complications. Control tissue was macroscopically thicker than SCI one. Control specimen displayed an equal distribution of type I and type II fibers, while SCI sample displayed a prevalence of type II fibers SCI specimen displayed a significant reduction in COX-1 gene expression. This mini-invasive approach was easy, accurate and with low complication rate in performing skeletal muscle biopsy in both SCI patients and controls. CONCLUSIONS: This technique could be useful in conditions in which the overall quantity of specimen required is small like for molecular biology analysis. For histological diagnostic purposes and/or conditions in which the original tissue is already pathologically modified, this technique should be integrated with more invasive techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The measurement of calcitonin in washout fluids of thyroid nodule aspirate (FNA-calcitonin) has been reported as accurate to detect medullary thyroid carcinoma (MTC). The results from these studies have been promising and the most updated version of ATA guidelines quoted for the first time that "FNA findings that are inconclusive or suggestive of MTC should have calcitonin measured in the FNA washout fluid." Here we aimed to systematically review published data on this topic to provide more robust estimates. RESEARCH DESIGN AND METHODS: A comprehensive computer literature search of the medical databases was conducted by searching for the terms "calcitonin" AND "washout." The search was updated until April 2015. RESULTS: Twelve relevant studies, published between 2007 and 2014, were found. Overall, 413 thyroid nodules or neck lymph nodes underwent FNA-calcitonin, 95 were MTC lesions and 93 (97.9%) of these were correctly detected by this measurement regardless of their cytologic report. CONCLUSIONS: The present study shows that the above ATA recommendation is well supported. Almost all MTC lesions are correctly detected by FNA-calcitonin and this technique should be used to avoid false negative or inconclusive results from cytology. The routine determination of serum calcitonin in patients undergoing FNA should improve the selection of patients at risk for MTC, guiding the use of FNA-calcitonin in the same FNA sample and providing useful information to the cytopathologist for the morphological assessment and the application of tailored ancillary tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Part I - Fluorinated Compounds A method has been developed for the extraction, concentration, and determination of two unique fluorinated compounds from the sediments of Lake Ontario. These compounds originated from a common industrial landfill, and have been carried to Lake Ontario by the Niagara River. Sediment samples from the Mississauga basin of Lake Ontario have been evaluated for these compounds and a depositional trend was established. The sediments were extracted by accelerated solvent extraction (ASE) and then underwent clean-up, fractionation, solvent exchange, and were concentrated by reduction under nitrogen gas. The concentrated extracts were analyzed by gas chromatography - electron capture negative ionization - mass spectrometry. The depositional profile determined here is reflective of the operation of the landfill and shows that these compounds are still found at concentrations well above background levels. These increased levels have been attributed to physical disturbances of previously deposited contaminated sediments, and probable continued leaching from the dumpsite. Part II - Polycyclic Aromatic Hydrocarbons Gas chromatography/mass spectrometry is the most common method for the determination of polycyclic aromatic hydrocarbons (PAHs) from various matrices. Mass discrimination of high-boiling compounds in gas chromatographic methods is well known. The use of high-boiling injection solvents shows substantial increase in the response of late-eluting peaks. These solvents have an increased efficiently in the transfer of solutes from the injector to the analytical column. The effect of I-butanol, I-pentanol, cyclopentanol, I-hexanol, toluene and n-octane, as injection solvents, was studied. Higher-boiling solvents yield increased response for all PAHs. I -Hexanol is the best solvent, in terms of P AH response, but in this solvent P AHs were more susceptible to chromatographic problems such as peak splitting and tailing. Toluene was found to be the most forgiving solvent in terms of peak symmetry and response. It offered the smallest discrepancies in response, and symmetry over a wide range of initial column temperatures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Malgré des taux d’efficacité comparable du traitement antiviral de l’hépatite C (VHC) entre utilisateurs de drogues par injection (UDIs) et non-UDIs, il y a encore d’importantes barrières à l’accessibilité au traitement pour cette population vulnérable. La méfiance des UDIs à l’égard des autorités médicales, ainsi que leur mode de vie souvent désorganisé ont un impact sur l’initiation du traitement. L’objectif de cette étude est d’examiner les liens entre l’initiation du traitement du VHC et l’utilisation des services de santé chez les UDIs actifs. Methode: 758 UDIs actifs et séropositifs aux anticorps anti-VHC ont été interrogés durant la période de novembre 2004 à mars 2011, dans la région de Montréal. Des questionnaires administrés par des intervieweurs ont fourni des informations sur les caractéristiques socio-économiques, ainsi que sur les variables relatives à l’usage de drogues et à l’utilisation des services de santé. Des échantillons sanguins ont été prélevés et testés pour les anticorps anti-VHC. Une régression logistique multivariée a permis de générer des associations entre les facteurs relatifs aux services de santé et l’initiation du traitement contre le VHC. Resultats: Parmi les 758 sujets, 55 (7,3%) avaient initié un traitement du VHC avant leur inclusion dans l’étude. Selon les analyses multivariées, les variables significativement associées à l’initiation du traitement sont les suivantes: avoir vu un médecin de famille dans les derniers 6 mois (Ratio de Cote ajusté (RCa): 1,96; Intervalle de Confiance à 95% (IC): 1,04-3,69); plus de 2 ans sous traitement de la dépendance à vie, sans usage actuel de méthadone (RCa: 2,25; IC: 1,12-4,51); plus de 2 ans sous traitement de la dépendance à vie, avec usage actuel de méthadone (RCa: 3,78; IC: 1,85-7,71); et avoir déjà séjourné en prison (RCa: 0,44; IC: 0,22-0,87). Conclusion: L’exposition à des services d’aide à la dépendance et aux services médicaux est associée à l’initiation du traitement du VHC. Ces résultats suggèrent que ces services jouent leur rôle de point d’entrée au traitement. Alternativement, les UDIs ayant initié un traitement du VHC, auraient possiblement adopté une attitude proactive quant à l'amélioration de leur santé globale. D’autre part, l’incarcération ressort comme un obstacle à la gestion de l’infection au VHC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The physical and empirical relationships used by microphysics schemes to control the rate at which vapor is transferred to ice crystals growing in supercooled clouds are compared with laboratory data to evaluate the realism of various model formulations. Ice crystal growth rates predicted from capacitance theory are compared with measurements from three independent laboratory studies. When the growth is diffusion- limited, the predicted growth rates are consistent with the measured values to within about 20% in 14 of the experiments analyzed, over the temperature range −2.5° to −22°C. Only two experiments showed significant disagreement with theory (growth rate overestimated by about 30%–40% at −3.7° and −10.6°C). Growth predictions using various ventilation factor parameterizations were also calculated and compared with supercooled wind tunnel data. It was found that neither of the standard parameterizations used for ventilation adequately described both needle and dendrite growth; however, by choosing habit-specific ventilation factors from previous numerical work it was possible to match the experimental data in both regimes. The relationships between crystal mass, capacitance, and fall velocity were investigated based on the laboratory data. It was found that for a given crystal size the capacitance was significantly overestimated by two of the microphysics schemes considered here, yet for a given crystal mass the growth rate was underestimated by those same schemes because of unrealistic mass/size assumptions. The fall speed for a given capacitance (controlling the residence time of a crystal in the supercooled layer relative to its effectiveness as a vapor sink, and the relative importance of ventilation effects) was found to be overpredicted by all the schemes in which fallout is permitted, implying that the modeled crystals reside for too short a time within the cloud layer and that the parameterized ventilation effect is too strong.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose - The purpose of this paper is to develop a novel unstructured simulation approach for injection molding processes described by the Hele-Shaw model. Design/methodology/approach - The scheme involves dual dynamic meshes with active and inactive cells determined from an initial background pointset. The quasi-static pressure solution in each timestep for this evolving unstructured mesh system is approximated using a control volume finite element method formulation coupled to a corresponding modified volume of fluid method. The flow is considered to be isothermal and non-Newtonian. Findings - Supporting numerical tests and performance studies for polystyrene described by Carreau, Cross, Ellis and Power-law fluid models are conducted. Results for the present method are shown to be comparable to those from other methods for both Newtonian fluid and polystyrene fluid injected in different mold geometries. Research limitations/implications - With respect to the methodology, the background pointset infers a mesh that is dynamically reconstructed here, and there are a number of efficiency issues and improvements that would be relevant to industrial applications. For instance, one can use the pointset to construct special bases and invoke a so-called ""meshless"" scheme using the basis. This would require some interesting strategies to deal with the dynamic point enrichment of the moving front that could benefit from the present front treatment strategy. There are also issues related to mass conservation and fill-time errors that might be addressed by introducing suitable projections. The general question of ""rate of convergence"" of these schemes requires analysis. Numerical results here suggest first-order accuracy and are consistent with the approximations made, but theoretical results are not available yet for these methods. Originality/value - This novel unstructured simulation approach involves dual meshes with active and inactive cells determined from an initial background pointset: local active dual patches are constructed ""on-the-fly"" for each ""active point"" to form a dynamic virtual mesh of active elements that evolves with the moving interface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the development and optimization of a sequential injection method to automate the determination of paraquat by square-wave voltammetry employing a hanging mercury drop electrode. Automation by sequential injection enhanced the sampling throughput, improving the sensitivity and precision of the measurements as a consequence of the highly reproducible and efficient conditions of mass transport of the analyte toward the electrode surface. For instance, 212 analyses can be made per hour if the sample/standard solution is prepared off-line and the sequential injection system is used just to inject the solution towards the flow cell. In-line sample conditioning reduces the sampling frequency to 44 h(-1). Experiments were performed in 0.10 M NaCl, which was the carrier solution, using a frequency of 200 Hz, a pulse height of 25 mV, a potential step of 2 mV, and a flow rate of 100 mu L s(-1). For a concentration range between 0.010 and 0.25 mg L(-1), the current (i(p), mu A) read at the potential corresponding to the peak maximum fitted the following linear equation with the paraquat concentration (mg L(-1)): ip = (-20.5 +/- 0.3) Cparaquat -(0.02 +/- 0.03). The limits of detection and quantification were 2.0 and 7.0 mu g L(-1), respectively. The accuracy of the method was evaluated by recovery studies using spiked water samples that were also analyzed by molecular absorption spectrophotometry after reduction of paraquat with sodium dithionite in an alkaline medium. No evidence of statistically significant differences between the two methods was observed at the 95% confidence level.